Tender For Replacement Of Old Split Ac And Supply Installation Testing and Commissioning of New Split Ac With electrical installation Wiring At Dnb Seminar Hall Of Imambara District Hospital,Hooghly
Tender Value
Ref. Documents
Estimated cost
Bid Submission
31 Jul 2026
8 days left
EMD
10079
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hooghly → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Replacement Of Old Split Ac And Supply Installation Testing and Commissioning of New Split Ac With electrical installation Wiring At Dnb Seminar Hall Of Imambara District Hospital,Hooghly
BOQ
| Sl. No. | Item Description |
| 1 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required.[E-14, 1.a]2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC. [E-14, 1.a.iii] |
| 2 | S&F of 250V timer DB (equivalent to 12 way SPNDB in size) with double door sheet steel enclosure, neutral bar, din rail, with IP43 protection comprises with 1 nos 25A DPMCB(C-curve 10ka) and 1 no 24 hr digital time switch(L&T,GIC) and 1 no 18A(L&T MNX 18-2P, cat no.- CS94101) power contactor,complete with internal wiring (1.5 sq.mm - control wiring.4.0 sq.mm - power wiring) with suitable size of copper wire including 1 no toggle switch(For Auto/Manual/Off), with Door locking arrangement by common panel keys as used in panel and 2 nos LED( RED color AC ON , GREEN color - AC OFF must be written in engraving/steel/plastic plate by black color) indicator and earthing attachment as per direction of EIC (Make:- L&T/SIEMENS/ABB/Legrand or equivalent make as approved by E.I.C) |
| 3 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages tobuilding works.4 Module Board[E-17,F-1a] |
| 4 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cuwire and earth continuity wire etc. [E-17,F-4.c] |
| 5 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. [E-17,F-5.b] |
| 6 | Supply & Fixing 240 V, 25A Modular starter (Brand approved by EIC) on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-19,20] |
| 7 | Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) 2'x2' withpowder-coated pressure Die-cast Aluminium/CRCA sheet body withhigh-transmission opal PMMA/ polycarbonate/ prismatic diffuserhaving uniform light distribution and construction as per IS : 10322.The driver rated output wattage should be 10% to 15% higher thanlamp rating and efficiency Driver >80%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range 00 to 400 C,internal surge protection of 2.5 KV with Short & Open circuitprotection, THD < 10% , PF ≥0.9, IP20, CRI >80, life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours(Life projection shall be calculated as per TM-21 methodology) and70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K/ 5700°K / 6000°K / 6500°K, Maximum power consumption shouldnot more than the specified rating and Fixture shall be confirming torelevant BIS standards and trade mark certificate (T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screenprinting on housing Complete in all respect and LED Chips of SMDLow to mid-power, as per requirement (LM-80 tested) and necessaryinter-connections with 1.5 sq mm FR, PVC insulated copperconductor single core cable and earthing etc. as required withMinimum 5 year OEM comprehensive on-site warranty againstmanufacturing defects including driver and LED module. All testreport except L80 should be from 3rd party NABL accredited Lab asper BIS shall be submitted. Shape size and CCT shall be as approvedby Engineer-in-Charge as per requirement. Make - Philips/Cromton /WiproSystem lumen efficacy ≥135 lm/Watt 38 -40 watt |
| 8 | Supply & Fixing of LED (Make - Crompton LTT820 or approved by EIC) tube for existing fittings at different ward of Hospital . |
| 9 | Supply & Delivery of 230 V, 50 Hz, single phase, 85 watts, 18\\" (450mm),speed 1325 rpm (minimum), Bracket Fan and class of insulation: B, 4nos. metal (Aluminium alloy) blades, copper winding, steel/Al body withmetal back cover. Power Factor not less than 0.9 and minimum airdelivery 110 cu.m/min (minimum), including capacitor with safety pin,nut bolts, washers, temperature rise = 75 degree C (max.), insulationresistance more than 2 mega ohm, suitable for compliant to IS 374:2019and external connections with 1.5 sq.mm FR, PVC insulated copperconductor single core cable and earthing etc. as required.Make - Orient tornado wall-II or approved by EIC. |
| 10 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 6 way - Legrand Enclosure (607716)/SIEMENS- Enclosure (8GB32202RC06) [D-10,14] |
| 11 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. 2+12 Way [Siemens Enclosure(8GB32102RC14)/Schneider Enclosure (A9HSND12) or equivalent model of Legrand) as per direction of EIC [D-10,13] |
| 12 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand/ Schneider/Siemens/ Crabtree/ L&T) as per direction of EIC. ]63 A FP [D-5,6] |
| 13 | 40 A DP [D-5,6 ] |
| 14 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make-Legrand/ Schneider/Siemens/Crabtree/L&T) as per direction of EIC. ]6-32 SP [ D- 6, 7 ] |
| 15 | Supply, Installation, Testing, and Commissioning of air-cooled Hi-Wall split type air conditioners of following capacities comprising Indoor and Outdoor Units with factory-charged Rotary/Scroll compressors (R-32/R-410A) including surface/concealed copper refrigerant piping insulated with closed-cell elastomeric nitrile rubber insulation and wrapping tape (up to 3 m), FRLS type copper power cable (up to 3.5 m) with suitable plug top, 3 meters of drain pipe, and wireless remote control with suitable battery. The system shall operate on 230V, 50Hz (±tolerance as per applicable standard), single-phase AC supply, providing cooling, dehumidification, and air circulation functions conforming to IS-1391 (Part-II ) with all amendments, and shall be capable of efficient performance at outdoor ambient temperatures up to 50°C, with a minimum 5-year OEM warranty on both the compressor and PCB. The system shall be installed with S&F appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete in all respect as per the direction of EIC. Non Inverter type AC, Make - Daikin/Hitachi or equivalent make as approve by EIC |
| 16 | Cooling Capacity- 5.2 kW (Minimum) , Air Flow Rate:600 CFM (Minimum)Minimum 3-Star |
| 17 | Cooling Capacity- 6.1 kW (Minimum) , Air Flow Rate:800 CFM (Minimum)Minimum 3-Star |
| 18 | Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 19 | 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 20 | S&F of additional following items for length exceeding 3.5 mtr for complete installation and commissioning of aboove AC machines.i) 2.5 sqmm, 3/4 core copper cable (FRLS type) |
| 21 | Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC. |
| 22 | 1. THE AGENCY MUST PROCURE THE MATERIALS FROM THE MANUFACTURER/OEM OR FROM THEIR AUTHORIZES. SALES CHANNEL SO THAT THE STANDARD WARRANTY / SUPPORT OF THE MANUFACTURER / OEM BECOMES APPLICABLE TO THE PRODUCTS TO BE DELIVERED AND INSTALLED BY THEM.2. DOCUMENTS THAT AUTHENTICATES SUCH PROCUREMENT FROM THE MANUFACTURER/OEM OR FROM THEIR AUTHORIZES SALES CHANNEL SO THAT THE STANDARD WARRANTY / SOPPORT SHOULD BE SENT FROM THE e-MALE OF THE MANUFACTURER/OEM / AUTHORIZES SALES CHANNEL TO THE e-MALE OF ENGINEER-IN-CHARGE AND HARD COPY OF IT TO BE SUBMITTED DURING EXECUTION OF WORK/ SUBMISSION OF BILL.3. IF ANY REFURBISHED MATERIAL IS SIPPLIED ABD INSTALLED, PENAL ACTION WILL BE TAKEN AS PER EXISTING RULES. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysAug 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender