Tender for Repair Maintenance Of Stp, Swt, Mechanical Laundry, Electric Incinerators, Composting Machine And Allied Works Under Ge 873 Ews
BOQ
| Sl. No. | Item Description |
| 1 | M & L for Servicing and Troubleshooting of oil fired incinerator 25 - 50 KG/ per hrs capacity by provding auth/ qualified perons quaterly visits or emergency callout as an when required and rectification of u/s devices in each quarter Note: (i) Spare parts as required site shall be measured & paid separately in respective items here in after. |
| 2 | Supply only Nozzle as per existing sample |
| 3 | Supply only Fuel pump as per existing sample |
| 4 | Supply only Pressure gauge as per existing sample. |
| 5 | Supply only Photo cell as per existing sample |
| 6 | Supply only diesel filter as per existing sample |
| 7 | Supply only Flexible hose pipe as per existing sample |
| 8 | Supply only Inlet oil valve of 15mm dia as per existing sample |
| 9 | Supply only Sequence controller as per existing sample |
| 10 | M&L for replacement of gasket for manual feeding door and ash removal door of Incinerator complete all as specified and directed. |
| 11 | M & L for reparing of Induced draft/ forced draft fan, oiling and greasing and replacement of bearings complete all as specified and directed. |
| 12 | S&F in replacement of temperature controlling rod as per existing sample complete all as specified and directed. |
| 13 | S&F in replacement temperature controller as per existing sample complete all as specified and directed. |
| 14 | S&F in replacement relay as per existing sample complete all as specified and directed. |
| 15 | S&F in replacement contactor as per existing sample complete all as specified and directed. |
| 16 | S&F in replacement V-belt as per existing sample complete all as specified and directed. |
| 17 | Opening dismantling and disconnecting all water connection and electrical connection of washer extractor capacity 30 -50 Kg and reassemble the same for repair after removing nuts and bolts including oiling, greasing and alignment of inner basket, alignment of shaft, pulley alignment, contract set of contractor cleaning, servicing and cleaning of pneumatic kits, air filter cleaning, cleaning the drain system and turning work and reassembling the same and testing on completion.Note: spare parts shall be measure and paid separately under appropriate items. |
| 18 | Supply only touch screen for any Size/washer extractor machine as per existing sample |
| 19 | Supply only V belt as per existing sample. |
| 20 | Supply only angle steam valve |
| 21 | Supply only bearingas per existing sample |
| 22 | Supply only steam solenoid valve as per existing sample |
| 23 | Opening dismantling and disconnecting all water connection and electrical connection of drying tumbler capacity of 30-50 Kg and reassemble the same for repair after removing nuts and bolts including Oiling, cleaning, servicing and greasing, balancing and alignment of cylindrical basket, balancing of blower, shaft turning, cleaning and servicing of steam radiator for the smooth functioning of the machine all as directed. Note: Spare parts shall be measure and paid separately under appropriate items. |
| 24 | Supply only V-belt as per existing sample. |
| 25 | Supply only contractor 25 Amp with NC-Block. as per existing sample |
| 26 | Supply only limit switch for auto door closer & opener. as per existing sample |
| 27 | Supply only time switch reversing type as per existing sample |
| 28 | Supply only steam stop valve 15/20 mm bore. |
| 29 | Supply only over load relay as per existing sample |
| 30 | Supply only ball bearing for both side of Calendaring drum as per existing sample |
| 31 | S & F in replacement chlorine dosing FRP service tank 100 Ltr capacity consisting of dosing pump 15 LPH, agitator motor, level gauge , water inlet & outlet line, strainer, drain pipe etc as per existing sample complete all as specified and directed. |
| 32 | Supply only sodium hypo chloride solution of 12.5% strength in sealed container all as per sample |
| 33 | Supply only Alum Ferric of best quality in packing bags as per sample. |
| 34 | Testing of sewage water water analyse the following parameters through NABL approved laboratory:-a) BOD , COD, TSS, Ecoli |
| 35 | S & F in replacement Induction motor 2 HP capacity 50 Hz single phase AC power supply, Motor Insulation Class F , High quality graded cast iron Motor body, Cast iron FG 200 Pump Casing:, Stainless Steel Shaft SS410 as per existing sample complete all as specified and directed. |
| 36 | S&F in replacement PVC insulated, PVC sheathed, cable ISI marked with multi stranded copper conductor 1100 volt grade of size 2.5 Sqmm 3 core complete all as specified and directed. |
| 37 | S & F in replacement Centrifugal monoblock pump set 2 HP capacity 50 Hz single phase AC power supply, having discharge 21000 ltr/hrs at 12 mtr head , Motor Insulation Class F, High quality graded cast iron Motor body, Cast iron FG 200 Pump Casing:, Stainless Steel Shaft SS410 as per existing sample complete all as specified and directed. |
| 38 | S & F in replacement sewage lifting pump set 2 HP capacity 50 Hz single phase AC power supply with float switch, having discharge 640 ltr/min at 10 mtr head Motor Insulation Class F , High quality graded cast iron Motor body, Cast iron FG 200 Pump Casing:, Stainless Steel Shaft SS410 as per existing sample complete all as specified and directed. |
| 39 | S&F in replacement 1HP openwell submersible pump set copper wounded, S/S body, Single Phase, 230 Volts complete all as specified and directed. |
| 40 | S & F in replacement submersible pump controller with OLP, MCB & Contactor , relay, Capacitor Run & Start in sheet metal enclosure type with Ammeter and voltmeter single phase, 230V, 50 Hz suitable for 1 HP electric motor complete all as specified and directed. Make of L & T / BCH/Havells |
| 41 | S & F in replacement submersible pump controller with OLP, MCB & Contactor , relay, Capacitor Run & Start in sheet metal enclosure type with Ammeter and voltmeter single phase, 230V, 50 Hz suitable for 2 HP electric motor complete all as specified and directed. Make of L & T / BCH/Havells |
| 42 | S & F in replacement submersible pump controller of relay range 9-14 Amps in sheet metal enclosure type with Ammeter and voltmeter AC-3 phase, 415V, 50 Hz suitable for 5 HP electric motor complete all as specified and directed. Make of L & T model MU-G6 or equivalent model of make ABB/Havells |
| 43 | S & F in replacement of High density poly- ethylene pipes (HDPE) size 65 mm dia of pressure rating 8 kgf/cm2 for subersible pump column pipe of bore well including fixing necessary Stainless steel Nipple & SS coupling for top and bottom of HDPE pipe complete all as specified and directed. |
| 44 | S & F in replacement of High density poly- ethylene pipes (HDPE) size 50 mm dia of pressure rating 8 kgf/cm2 for subersible pump column pipe of bore well including fixing necessary Stainless steel Nipple & SS coupling for top and bottom of HDPE pipe complete all as specified and directed. |
| 45 | Excavation in trenches n.exc. 1.5 mtr wide and n.exc. 1.5 mtr. In depth for foundation, laying of water pipe line and getting out in Hard / dense soil.etc. complete all as specified and as directed. |
| 46 | Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the pipe etc.complete all as specified and directed |
| 47 | Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed etc. complete all as specified and directed. |
| 48 | Supply and fixing in replacement High pressure braided rubber/ thermoplastic hose pipe of ISI Marked 20 mm dia, 30 meter length complete all as specified and directed. |
| 49 | S & F in replacement bronze ball valve with handle, screwed both ends suitable for 40 mm dia iron pipe complete all as specified and directed. |
| 50 | S & F in replacement bronze ball valve with handle, screwed both ends suitable for 50 mm dia iron pipe complete all as specified and directed. |
| 51 | S & F in replacement bronze ball valve with handle, screwed both ends suitable for 25 mm dia iron pipe complete all as specified and directed. |
| 52 | Supply, fixing, connecting and testing sheet metal enclosures double door type for using MCBs suitable for single pole and neutral, 4 way TPN with having copper bus bars suitable for 200 amps rating including taking down old unserviceable one complete all as specified & as directed |
| 53 | S & F for MCCB 4 Pole, 415 V, fixed type, 100 Amps with breaking capacity 16 KA with including IP 65 sheet metal encloser complete all as specified and directed. |
| 54 | S & F in replacement MCB Triple pole & neutral (TPN), 40 to 63 Amps, 415 volts, 10KA, ‘C’ series, with proper size lugs and connections complete all as specified and directed. |
| 55 | S & F in replacement MCB Triple pole (TP), 25 to 63 Amps, 415 volts, 10KA, ‘C’ series, with proper size lugs and connections complete all as specified & as directed |
| 56 | S & F in replacement MCB single pole & neutral (SP&N), 16 to 32 Amps, 240 volts, 10KA, ‘C’ series, with proper size lugs and connections complete all as specified & as directed |
| 57 | S & F in replacement for outdoor type IP66, Energy saving LED street light fitting 35 Watt 230 V AC with PDC Aluminium body & Secondary optical lens for superior light distribution. Efficacy >110 Lm/W. with high pressure die cast aluminum hosing and heat resistant LED street light fitting with driver, complete all as specified and directed. |
| 58 | S & F in replacement Surface and wall mounted high efficacy 1x20 watt LED LED lighting fixture with extruded polycarbonate, environmental friendly, complete with all accessories internally pre wired and including connection up with twin core flexible copper conductior cable complete all as specified and directed. |
| 59 | Supply, laying in replacement cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with stranded aluminium conductor, 1100 Volts grade, of size 35 Sqmm 3.5 Core complete all as specified and as directed. |
| 60 | Supply, laying in replacement cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with stranded aluminium conductor, 1100 Volts grade, of size 25 Sqmm 3.5 Core complete all as specified and as directed. |
| 61 | Supply, laying in replacement cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with stranded aluminium conductor, 1100 Volts grade, of size 16 Sqmm 4 Core complete all as specified and as directed. |
| 62 | S & FF in replacement 3 layer PP-R (Poly propylene Random copolymer) pipes PN - 16 Pipe, 25 mm OD (SDR-7.4) confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, /walls/ceilings or laying in floors complete all as specified and directed. |
| 63 | All as per item No 42 above but for 32mm outer dia PP-R pipes. |
| 64 | All as per item No 42 above but for 40mm outer dia PP-R pipes. |
| 65 | All as per item No 42 above but for 50mm outer dia PP-R pipes. |
| 66 | M & L for making connection of PP-R distribution branch from 16 to 40 mm PP-R main by providing and fixing tee including cutting and making fusion joint etc. complete all as specified and directed. |
| 67 | M & L for making connection of PP-R distribution branch from 50 to 75 mm PP-R main by providing and fixing tee including cutting and making fusion joint etc. complete all as specified and directed. |
| 68 | M&L for Fiber glass wool/ nitrile rubber insulation 25 mm thick , density 40- 50 Kg/cum over pipes 50/63 mm outer dia incl 0.5 mm thick aluminium cladding including jointing and fixing material such as solvent adhesive SR-998 complete all as specified and directed. |
| 69 | M&L for Fiber glass wool/ nitrile rubber insulation 25 mm thick , density 40- 50 Kg/cum over pipes 40/32 mm outer dia incl 0.5 mm thick aluminium cladding including jointing and fixing material such as solvent adhesive SR-998 complete all as specified and directed. |
| 70 | M&L for Fiber glass wool/ nitrile rubber insulation 25 mm thick , density 40- 50 Kg/cum over pipes 25 mm outer dia incl 0.5 mm thick aluminium cladding including jointing and fixing material such as solvent adhesive SR-998 complete all as specified and directed. |
| 71 | S & F for Heat tape laying over pipe with thermostate for PPR water pipe suitable for upto - 35 degree temp complete all as specified and directed . |
| 72 | Supply and laying 50 mm outer dia HDPE pipe (DWC) Double wall corrugated outer surface and smooth inner wall, ISI marked and as per IS : 16205 (part-24) or latest IS 14930 (part-II), 450N compressive strength with snap fit coupler with rubber ring for underground electrical cable protection conduits Orange colour complete all as specified and directed. |
| 73 | M & L for maintenance free GI earthing Electrode 2 mtr length shall be based on ready capsule type, Pipe-in-Cage technology concept in which, One Galvanized hollow pipe (Electrode) 50 mm dia filled with a specially developed earth enhancement material (EEM) made up of Conductive Cement, Graphite carbon powder, Sodium montmorillonite/ Sodium Bentonite Powder, Hydrous aluminum silicate etc. to reduce earth resistivity, 50kg Chemical , GI earthing Electrode buried directly in ground vertically to a depth not less than 2.0 meter below normal ground level and connected by means of GI wire 4.0 mm dia , galvanized bolts, nuts and washers , watering pipe with funnel including necessary earth work and PVC moulded earth pit with cover and dismantling/taking out of old unserviceable earthing of any position complete all as specified and directed |
| 74 | M & L for topup and filling of 2mm size quartz sand in pressure water sand filter complete all as specified and directed. |
| 75 | M & L for taking out of old blocked Carbon and fillig of new activated carbon as per sample in exiting carbon filter complete all as specified and directed. |
| 76 | S & F in replacement of PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floorsr complete all as specified and as directed. |
| 77 | M & L for taking out 5000- 10000 ltr capacity SWT material with sewage suction pump vehicle incl all loose/ sedimented sand, sludge, mud etc and disposed off the same outside the cantt area inclusive safety protection/devices for working men power while working complete all as specified and directed. |
| 78 | M & L for Cleaning of Equalizer sump with sewage suction pump vehicle and removal of all loose/ sedimented sand, sludge, mud, vegetation, grit, rages, fibers and string materials etc. and disposed off the same outside the cantt area complete all as specified and directed. |
| 79 | M & L for Cleaning of Tube setler sump with sewage suction pump vehicle and removal of all loose/ sedimented sand, sludge, mud, vegetation, grit, rages complete all as specified and directed. |
| 80 | M & L for Cleaning of sewage Treated water tank with sewage suction pump vehicle and removal of all loose/ sedimented sand, sludge, mud etc and disposed off the same outside the cantt area inclusive safety protection/devices for working men power while working complete. Note for item No 57 to 60 :- (i) All safety precautions as per IE rules should be strictly followed by Contractor during working men. In case of any accident/ Injury, occured during working the contractor shall be solely responsible for setting all Claims/ Compensation.(ii) Contractor should be provide suitable capapcity nonclog submersible pump set for taking out incoming sewage water while cleaning of sump. |
| 81 | M & L for removal of all undigested, floating material like polythene, plastic ,wood pieces, rubber and string materials etc of bar screen chamber and sewage sump . and surrounding area of STP complete all as specified and directed. |
| 82 | Supply and connecting Rotationally Moulded, Septic Tanks 3000 Ltr Capacity Seamless, Watertight , Robust in Design With a Unique Rib Structure, Chemical Resistance in Base camp STP incl taking down all complete all as specified and directed. |
| 83 | M & L for Construction of chamber/ pit of size 2000 x 1500 x 1500 mm with brick wall in cement mortar (1:6) PCC (1:4:8) type D2 using 40 mm graded stone aggregate in foundation, internal surfaces plastering, including 10 mm thick cement mortar (1:4) PCC (1:2:4) type B 0 using 12.5 mm graded stone aggregate in copping, mild steel angle iron frame 40 x 40 x 4 mm & MS sheet cover 3.0 mm thick including locking arrangement with all necessary excavation & earth work in any type of soil complete all as specified and directed |
| 84 | M & L for rewinding of 2/3 HP electric motor of washing machine/ dryer with copper winding wire of same gauge including impregnated paper, sleevs, lathorised fibre glass, and tape, etc complete all as specified and directed. |
| 85 | Deduct Schedule of Credit of as listed in Schedule 'A' Part-II. Contract Sum shall be arrived after deducting the credit amount.Note :- Tenderers will not quote against this item Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysAug 13, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender