Name of Work:- Construction of Krushak Bazar and Hata at Mining Road in Keonjhargarh Municipality
Sl. No. Item Description
1SITE DEVELOPMENT AND LANDSCAPING- Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness.
2Supply & Filling at all depth with available good filling Earth (excluding rock) in mechanical carriage of good garden soil etc. in the smart park area in layers not exceeding 15cm in depth consolidating each deposited layer by ramming and watering complete ( lead upto 100m) as directed by Enginner-In-Charge.
3Compacting and watering upto OMC rolling earth work with P.R.R. in embankment in layers not exceeding 0.23m by power road roller including hire and running charges of the roller (measurement to be taken on the finished compacted section of the fill under O.M.C. condition) (See Page no-06,Item no 9 of AoR-06)
4Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge. (standard data book_DSR_2020_Horticulture code.no.2.33 page 91)
5Supplying and stacking of sludge at site (standard data book_DSR_2020_Horticulture code.no.2.30 page 83) etc. complete as per directed by the Engineer-in-charge.
6Spreading of sludge , dump manure in require thickness (standard data book_DSR_2020_Horticulture code.no.2.4.3. page 83) etc. complete as per directed by the Engineer-in-charge.
7Plantation of Trees , Shurbs and Hedge at site i/c watering and removal of unservicable materials as per direction of officer in Charge.(Rate as per DSR-2020 Horticulture , Page no.259 Sl.no. 2.57)) as directed by the Engineer-in Charge.
8Supplying and fixing of pre cast kerb stone of size 300mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758: 1984.
9PAVER BLOCK APPROACH ROAD-Earth work in excavation of foundation trenches in all kids of soil including dressing and leavelling the bed upto the required depth and depositing the excaveted materials with all leads & lifts T&P Shoring and shuttering watering if necessary etc. complete as per directed by the Engineer-in-charge.
10Supplying and filling foundation and plinth with sand watered and rammed including cost, conveyance, royalties and taxes of all materials and cost of all labour, T&P required for the work etc. complete (measurement will be taken on finished compacted section only) as directed by the Engineer-in Charge.
11Cement concrete (1:3:6) using approved quality from approved quarry including lowering laying concrete watering and curing etc. as required levels laid in layers not exceeding(0'-6'') 15 cm thick including cost, conveyance,royalities and taxes of all materials and cost of all labour ,T&P required for the work etc. complete in all respect as directed by the Engineer-in-charge .
12Supply and laying M30 grade heavy duty factory made hydraucally pressed and mechanically compacted free cast inter looking paver block with sand binding and final compaction with plate vibrator finishing the surface including cutting the block with its edges and fixing kerbstone along both sede of the pathway all complete as per specification and direction of Engineer-in-charge.80 mm thick paver block in parking area
1360 mm thick paver block in Pathway area
14KIOSK PIND & CANOPY-Earth work in excavation of foundation trenches in all kids of soil including dressing and leavelling the bed upto the required depth and depositing the excaveted materials with all leads & lifts T&P Shoring and shuttering watering if necessary etc. complete as per directed by the Engineer-in-charge.
15Supplying and filling foundation and plinth with sand watered and rammed including cost, conveyance, royalties and taxes of all materials and cost of all labour, T&P required for the work etc. complete (measurement will be taken on finished compacted section only) as directed by the Engineer-in Charge.
16Cement concrete (1:3:6) using approved quality from approved quarry including lowering laying concrete watering and curing etc. as required levels laid in layers not exceeding(0'-6'') 15 cm thick including cost, conveyance,royalities and taxes of all materials and cost of all labour ,T&P required for the work etc. complete in all respect as directed by the Engineer-in-charge .
17R.C.C. work M-25 in grade having a minimum compressive strength (in work test) 250 kg/cm2 in 15cm cubes at 28 days using 12mm. & down grade hard granite C.B. chips of approved quality and from approved quarry including watering, lowering laying concrete, compacting with vibrators, curing for 28 days with smooth etc. complete.(A) Column Footing Base
18(B) Plinth Beam
19(C) R.C.C. Columns
20(F) R.C.C. Slab at floor base of Kiosk
21Rigid smooth centering & shuttering for R.C.C. works including false works and dismantlling them after casting including cost of materials complete.(A) R.C.C. Floor Slab
22(B) Column base
23(C) R.C.C. Column
24(D) R.C.C. Plinth Beam
25Supplying Cutting,bending un- coated HYSD bars,for reinforcement tying the grills and placing in position as required for the RCC works and for providing fan hooks hoisting and lowering,laying including cost,conveyance & taxes of SYSD bars and binding wires of 18 to 20 gauge required for the work and bending binding and tying the grills .
26Fly ash bricks masonary incm (1:6) after immersing the bricks 6 hrs. in water before use in Foundation and plinth having C.S. 75kg/cm2 in cluding all cost, carriage, royality etc. complete.
2712 mm thick cement plaster in cm (1:6) over brick wall finished smooth after raking out the joints including watering, curing with cost, conveyence etc.complete.
28Finishing wall surface with weather coat 2 coat over a coat of primer to the new surfaces of walls with including all cost as per direction of Engineer-in-charge.
29Fixing of granite tiles in floors above 0.4m size of 20mm thick of approved make coformaing to I.S:13755 laid on on 25mm thick bed of Cement mortar 1:4 ( 1 Cement : 4 sand ) and filling joint with white Cement of approved quality in slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of tiles or stones. ( For new work)with cost of all materials labor etc. complete.
30OFFICE BUILDING GROUND FLOOR- Earth work in excavation of foundation trenches in all kids of soil including dressing and leavelling the bed upto the required depth and depositing the excaveted materials with all leads & lifts T&P Shoring and shuttering watering if necessary etc. complete as per directed by the Engineer-in-charge.
31Supplying and filling foundation and plinth with sand watered and rammed including cost, conveyance, royalties and taxes of all materials and cost of all labour, T&P required for the work etc. complete (measurement will be taken on finished compacted section only) as directed by the Engineer-in Charge.
32Cement concrete (1:3:6) using approved quality from approved quarry including lowering laying concrete watering and curing etc. as required levels laid in layers not exceeding(0'-6'') 15 cm thick including cost, conveyance,royalities and taxes of all materials and cost of all labour ,T&P required for the work etc. complete in all respect as directed by the Engineer-in-charge .
33R.C.C. work M-25 in grade having a minimum compressive strength (in work test) 250 kg/cm2 in 15cm cubes at 28 days using 12mm. & down grade hard granite C.B. chips of approved quality and from approved quarry including watering, lowering laying concrete, compacting with vibrators, curing for 28 days with smooth etc. complete.(A) Column Footing Base
34(B) Plinth Beam
35(C) R.C.C. Columns
36(D) Lintel
37(E) Roof Beam
38(F) R.C.C. Roof Slab
39(G) 150mm thick R.C.C. Chain link Stair
40Rigid smooth centering & shuttering for R.C.C. works including false works and dismantlling them after casting including cost of materials complete. (A) R.C.C. Roof Slab
41(A) Column base
42(B) R.C.C. Roof Beam
43(C) R.C.C. Column
44(D) R.C.C. Plinth Beam
45(E) R.C.C. Stair case
46(F) R.C.C. Lintel
47Supplying Cutting,bending un- coated HYSD bars,for reinforcement tying the grills and placing in position as required for the RCC works and for providing fan hooks hoisting and lowering,laying including cost,conveyance & taxes of SYSD bars and binding wires of 18 to 20 gauge required for the work and bending binding and tying the grills .
48Fly ash bricks masonary incm (1:6) after immersing the bricks 6 hrs. in water before use in Foundation and plinth having C.S. 75kg/cm2 in cluding all cost, carriage, royality etc. complete.
49Fly ash bricks masonary in cm (1:6) in Superstructure after immersing the bricks 6 hrs. In water before use in all floors having C.S. 75kg/cm2 in cluding all cost, carriage, royality etc. complete.
5012 mm thick cement plaster in cm (1:6) over brick wall finished smooth after raking out the joints including watering, curing with cost, conveyence etc.complete.
5116 mm thick cement plaster in cm (1:6) over brick wall finished smooth after raking out the joints including watering, curing with cost, conveyence etc.complete.In Side Wall Surface
526mm thick cement plaster in C.M. [1:4] finished smooth to exposed R.C.C. work with cost of all materials labor etc. complete. In Side Ceilling Surface
53Finishing wall surface with plastic emulsion paint 2 coat over a coat of primer to the new surfaces of walls with including all cost as per direction of Engineer-in-charge.
54Finishing wall surface with weather coat 2 coat over a coat of primer to the new surfaces of walls with including all cost as per direction of Engineer-in-charge.
55Fixing of anti skid granite tiles in floors above 0.4m size of 20mm thick of approved make coformaing to I.S:13755 laid on on 25mm thick bed of Cement mortar 1:4 ( 1 Cement : 4 sand ) and filling joint with white Cement of approved quality in slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of tiles or stones. ( For new work)with cost of all materials labor etc. complete.
56Fixing of Ceramic glazed tiles in dados, skirting riser of stepps 20cmx30cm / 20cmx20cm special plane / printed series of premium grade having thickness 6.5mm to 6.7mm confirming to IS 13753 on12 mm thick bed of Cement mortar 1:3 ( 1 Cement :3 sand ) jointed with neat Cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete excluding cost of tiles .
57Supplying fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia. Of 2mm thick circular pipe with balustrade of size 32mmx32mmx2mm @ 0.90mtr C/C and stainless square pipe of size 32mmx32mmx2mm in 3 rows in staircase as per approved design and specification etc all completed.
58Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame. shutters and all fitting and fixtures.
59Providing , fitting and fixing up partition walling OEL aluminum anodized section No.9210 and 9207 as single groove and double groove respectively as horizontal and vertical member and OEL section 4660 asTapered clip for fixing up 12mm thick prelaminated board (Nova pan Make) and jointing angle No. 1855 etc. complete as per Engineer-in-charge.
60Providing fitting, fixing of Al. door with OEL anodized Al. door section of 9202 as vertical member, 9201 as top member and 9200 as bottom and middle member and 6mm plain glass in top portion with 12mm thick pre-laminated board in bottom portion fixed on door frame by means of tapered clip No.4660 and the frame to be completed by means of jointing angle No.1855 including all cost of labour, T&P, hire charges of drilling machine, labour charges etc.complete.
61Providing fitting, fixing of flase celling with Aluminium anodized T section No. 3215 with 2'-0\\" centre to centre, L section No. 1705 upto 15 micron on 4 walls to be fixed by means of steel screw and PVC plug and the Aluminium grid 2'-0\\" x 2'-0\\" suspended from ceilling including all cost of labour, T&P, hire charges of drilling machine, labour charges etc.complete.
62Finishing wall surface of walls with Acrylicwall putty (Water based ) of approved makeand finished smooth and even surface toreceive painting including cost of scaffoldingstaging charges with cost of all materialstaxes, labour T&P etc complete as per Engineer-in-charge
63OFFICE BUILDING FIRST FLOOR- R.C.C. work M-25 in grade having a minimum compressive strength (in work test) 250 kg/cm2 in 15cm cubes at 28 days using 12mm. & down grade hard granite C.B. chips of approved quality and from approved quarry including watering, lowering laying concrete, compacting with vibrators, curing for 28 days with smooth etc. complete.(C) R.C.C. Columns
64(D) Lintel
65(E) Roof Beam
66(F) R.C.C. Roof Slab
67(G) 150mm thick R.C.C. Chain link Stair
68Rigid smooth centering & shuttering for R.C.C. works including false works and dismantlling them after casting including cost of materials complete.(A) R.C.C. Roof Slab
69(B) R.C.C. Roof Beam
70(C) R.C.C. Column
71(E) R.C.C. Stair case
72(F) R.C.C. Lintel
73Supplying Cutting,bending un- coated HYSD bars,for reinforcement tying the grills and placing in position as required for the RCC works and for providing fan hooks hoisting and lowering,laying including cost,conveyance & taxes of SYSD bars and binding wires of 18 to 20 gauge required for the work and bending binding and tying the grills .
74Fly ash bricks masonary in cm (1:6) in Superstructure after immersing the bricks 6 hrs. In water before use in all floors having C.S. 75kg/cm2 in cluding all cost, carriage, royality etc. complete.
75Fly ash bricks masonary in cm (1:4) in Superstructure after immersing the bricks 6 hrs. In water before use in all floors having C.S. 75kg/cm2 in cluding all cost, carriage, royality etc. complete.
7612 mm thick cement plaster in cm (1:6) over brick wall finished smooth after raking out the joints including watering, curing with cost, conveyence etc.complete.
7716 mm thick cement plaster in cm (1:6) over brick wall finished smooth after raking out the joints including watering, curing with cost, conveyence etc.complete.In Side Wall Surface
786mm thick cement plaster in C.M. [1:4] finished smooth to exposed R.C.C. work with cost of all materials labor etc. complete. In Side Ceilling Surface
79Finishing wall surface with plastic emulsion paint 2 coat over a coat of primer to the new surfaces of walls with including all cost as per direction of Engineer-in-charge.
80Finishing wall surface with weather coat 2 coat over a coat of primer to the new surfaces of walls with including all cost as per direction of Engineer-in-charge.
81Fixing of granite tiles in floors above 0.4m size of 20mm thick of approved make coformaing to I.S:13755 laid on on 25mm thick bed of Cement mortar 1:4 ( 1 Cement : 4 sand ) and filling joint with white Cement of approved quality in slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of tiles or stones. ( For new work)with cost of all materials labor etc. complete.
82Fixing of Ceramic glazed tiles in dados, skirting riser of stepps 20cmx30cm / 20cmx20cm special plane / printed series of premium grade having thickness 6.5mm to 6.7mm confirming to IS 13753 on12 mm thick bed of Cement mortar 1:3 ( 1 Cement :3 sand ) jointed with neat Cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete excluding cost of tiles .
83Supplying fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia. Of 2mm thick circular pipe with balustrade of size 32mmx32mmx2mm @ 0.90mtr C/C and stainless square pipe of size 32mmx32mmx2mm in 3 rows in staircase as per approved design and specification etc all completed.
84Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame. shutters and all fitting and fixtures.
85Providing fitting, fixing of Al. door with OEL anodized Al. door section of 9202 as vertical member, 9201 as top member and 9200 as bottom and middle member and 6mm plain glass in top portion with 12mm thick pre-laminated board in bottom portion fixed on door frame by means of tapered clip No.4660 and the frame to be completed by means of jointing angle No.1855 including all cost of labour, T&P, hire charges of drilling machine, labour charges etc.complete
86Providing fitting, fixing of flase celling with Aluminium anodized T section No. 3215 with 2'-0\\" centre to centre, L section No. 1705 upto 15 micron on 4 walls to be fixed by means of steel screw and PVC plug and the Aluminium grid 2'-0\\" x 2'-0\\" suspended from ceilling including all cost of labour, T&P, hire charges of drilling machine, labour charges etc.complete.
87Finishing wall surface of walls with Acrylicwall putty (Water based ) of approved makeand finished smooth and even surface toreceive painting including cost of scaffoldingstaging charges with cost of all materialstaxes, labour T&P etc complete as per Engineer-in-charge
88TERRACE FLOOR AND HEAD ROOM- R.C.C. work M-25 in grade having a minimum compressive strength (in work test) 250 kg/cm2 in 15cm cubes at 28 days using 12mm. & down grade hard granite C.B. chips of approved quality and from approved quarry including watering, lowering laying concrete, compacting with vibrators, curing for 28 days with smooth etc. complete.(A) R.C.C. Columns
89(B) Lintel
90(C) Roof Beam
91(D) R.C.C. Roof Slab
92Rigid smooth centering & shuttering for R.C.C. works including false works and dismantlling them after casting including cost of materials complete. (A) R.C.C. Roof Slab
93(B) R.C.C. Roof Beam
94(C) R.C.C. Column
95(F) R.C.C. Lintel
96Supplying Cutting,bending un- coated HYSD bars,for reinforcement tying the grills and placing in position as required for the RCC works and for providing fan hooks hoisting and lowering,laying including cost,conveyance & taxes of SYSD bars and binding wires of 18 to 20 gauge required for the work and bending binding and tying the grills .
97Fly ash bricks masonary in cm (1:6) in Superstructure after immersing the bricks 6 hrs. In water before use in all floors having C.S. 75kg/cm2 in cluding all cost, carriage, royality etc. complete.
9812 mm thick cement plaster in cm (1:6) over brick wall finished smooth after raking out the joints including watering, curing with cost, conveyence etc.complete.
9916 mm thick cement plaster in cm (1:6) over brick wall finished smooth after raking out the joints including watering, curing with cost, conveyence etc.complete.In Side Wall Surface
1006mm thick cement plaster in C.M. [1:4] finished smooth to exposed R.C.C. work with cost of all materials labor etc. complete. In Side Ceilling Surface
101Finishing wall surface with plastic emulsion paint 2 coat over a coat of primer to the new surfaces of walls with including all cost as per direction of Engineer-in-charge.
102Finishing wall surface with weather coat 2 coat over a coat of primer to the new surfaces of walls with including all cost as per direction of Engineer-in-charge.
103Providing fitting, fixing of Al. door with OEL anodized Al. door section of 9202 as vertical member, 9201 as top member and 9200 as bottom and middle member and 6mm plain glass in top portion with 12mm thick pre-laminated board in bottom portion fixed on door frame by means of tapered clip No.4660 and the frame to be completed by means of jointing angle No.1855 including all cost of labour, T&P, hire charges of drilling machine, labour charges etc.complete.
104Supplying fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia. Of 2mm thick circular pipe with balustrade of size 32mmx32mmx2mm @ 0.90mtr C/C and stainless square pipe of size 32mmx32mmx2mm in 3 rows in staircase as per approved design and specification etc all completed.
105Fixing of granite tiles in floors above 0.4m size of 20mm thick of approved make coformaing to I.S:13755 laid on on 25mm thick bed of Cement mortar 1:4 ( 1 Cement : 4 sand ) and filling joint with white Cement of approved quality in slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of tiles or stones. ( For new work)with cost of all materials labor etc. complete.
106Finishing wall surface of walls with Acrylicwall putty (Water based ) of approved makeand finished smooth and even surface toreceive painting including cost of scaffoldingstaging charges with cost of all materialstaxes, labour T&P etc complete as per Engineer-in-charge
107Providing 2.5cm thick Grading Concrete in C.C (1:2:2) with 4.7 mm size CBHG Chips on new roof slab including cost of materials , labour, T&P all comp.Terrace Floor
108Mummty Roof
109PANNEL ROOM - Earth work in excavation of foundation trenches in all kids of soil including dressing and leavelling the bed upto the required depth and depositing the excaveted materials with all leads & lifts T&P Shoring and shuttering watering if necessary etc. complete as per directed by the Engineer-in-charge.
110Supplying and filling foundation and plinth with sand watered and rammed including cost, conveyance, royalties and taxes of all materials and cost of all labour, T&P required for the work etc. complete (measurement will be taken on finished compacted section only) as directed by the Engineer-in Charge.
111Cement concrete (1:3:6) using approved quality from approved quarry including lowering laying concrete watering and curing etc. as required levels laid in layers not exceeding(0'-6'') 15 cm thick including cost, conveyance,royalities and taxes of all materials and cost of all labour ,T&P required for the work etc. complete in all respect as directed by the Engineer-in-charge .
112R.C.C. work M-25 in grade having a minimum compressive strength (in work test) 250 kg/cm2 in 15cm cubes at 28 days using 12mm. & down grade hard granite C.B. chips of approved quality and from approved quarry including watering, lowering laying concrete, compacting with vibrators, curing for 28 days with smooth etc. complete.(A) Column Footing Base
113(B) Plinth Beam
114(C) R.C.C. Columns
115(D) Lintel
116(E) Roof Beam
117(F) R.C.C. Roof Slab
118Rigid smooth centering & shuttering for R.C.C. works including false works and dismantlling them after casting including cost of materials complete.(A) R.C.C. Roof Slab
119(A) Column base
120(B) R.C.C. Roof Beam
121(C) R.C.C. Column
122(D) R.C.C. Plinth Beam
123(F) R.C.C. Lintel
124Supplying Cutting,bending un- coated HYSD bars,for reinforcement tying the grills and placing in position as required for the RCC works and for providing fan hooks hoisting and lowering,laying including cost,conveyance & taxes of SYSD bars and binding wires of 18 to 20 gauge required for the work and bending binding and tying the grills .
125Fly ash bricks masonary incm (1:6) after immersing the bricks 6 hrs. in water before use in Foundation and plinth having C.S. 75kg/cm2 in cluding all cost, carriage, royality etc. complete.
126Fly ash bricks masonary in cm (1:6) in Superstructure after immersing the bricks 6 hrs. In water before use in all floors having C.S. 75kg/cm2 in cluding all cost, carriage, royality etc. complete.
12712 mm thick cement plaster in cm (1:6) over brick wall finished smooth after raking out the joints including watering, curing with cost, conveyence etc.complete.
12816 mm thick cement plaster in cm (1:6) over brick wall finished smooth after raking out the joints including watering, curing with cost, conveyence etc.complete.In Side Wall Surface.
1296mm thick cement plaster in C.M. [1:4] finished smooth to exposed R.C.C. work with cost of all materials labor etc. complete. In Side Ceilling Surface.
130Finishing wall surface with plastic emulsion paint 2 coat over a coat of primer to the new surfaces of walls with including all cost as per direction of Engineer-in-charge.
131Finishing wall surface with weather coat 2 coat over a coat of primer to the new surfaces of walls with including all cost as per direction of Engineer-in-charge.
132Fixing of granite tiles in floors above 0.4m size of 20mm thick of approved make coformaing to I.S:13755 laid on on 25mm thick bed of Cement mortar 1:4 ( 1 Cement : 4 sand ) and filling joint with white Cement of approved quality in slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of tiles or stones. ( For new work)with cost of all materials labor etc. complete.
133Fixing of Ceramic tiles in dados, skirting riser of stepps 20cmx30cm / 20cmx20cm special plane / printed series of premium grade having thickness 6.5mm to 6.7mm confirming to IS 13753 on12 mm thick bed of Cement mortar 1:3 ( 1 Cement :3 sand ) jointed with neat Cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete excluding cost of tiles .
134Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame. shutters and all fitting and fixtures.
135Providing fitting, fixing of Al. door with OEL anodized Al. door section of 9202 as vertical member, 9201 as top member and 9200 as bottom and middle member and 6mm plain glass in top portion with 12mm thick pre-laminated board in bottom portion fixed on door frame by means of tapered clip No.4660 and the frame to be completed by means of jointing angle No.1855 including all cost of labour, T&P, hire charges of drilling machine, labour charges etc.complete.
136Providing fitting, fixing of flase celling with Aluminium anodized T section No. 3215 with 2'-0\\" centre to centre, L section No. 1705 upto 15 micron on 4 walls to be fixed by means of steel screw and PVC plug and the Aluminium grid 2'-0\\" x 2'-0\\" suspended from ceilling including all cost of labour, T&P, hire charges of drilling machine, labour charges etc.complete.
137Finishing wall surface of walls with Acrylicwall putty (Water based ) of approved makeand finished smooth and even surface toreceive painting including cost of scaffoldingstaging charges with cost of all materialstaxes, labour T&P etc complete as per Engineer-in-charge.
138Providing 2.5cm thick Grading Concrete in C.C (1:2:2) with 4.7 mm size CBHG Chips on new roof slab including cost of materials , labour, T&P all comp.
139COLD STORAGE BUILDING CIVIL WORKS-Earth work in excavation of foundation trenches in all kids of soil including dressing and leavelling the bed upto the required depth and depositing the excaveted materials with all leads & lifts T&P Shoring and shuttering watering if necessary etc. complete as per directed by the Engineer-in-charge.
140Supplying and filling foundation and plinth with sand watered and rammed including cost, conveyance, royalties and taxes of all materials and cost of all labour, T&P required for the work etc. complete (measurement will be taken on finished compacted section only) as directed by the Engineer-in Charge.
141Cement concrete (1:3:6) using approved quality from approved quarry including lowering laying concrete watering and curing etc. as required levels laid in layers not exceeding(0'-6'') 15 cm thick including cost, conveyance,royalities and taxes of all materials and cost of all labour ,T&P required for the work etc. complete in all respect as directed by the Engineer-in-charge .
142R.C.C. work M-25 in grade having a minimum compressive strength (in work test) 250 kg/cm2 in 15cm cubes at 28 days using 12mm. & down grade hard granite C.B. chips of approved quality and from approved quarry including watering, lowering laying concrete, compacting with vibrators, curing for 28 days with smooth etc. complete.(A) Column Footing Base
143(B) Plinth Beam
144(C) R.C.C. Columns
145(D) Lintel
146(E) Roof Beam
147(F) R.C.C. Roof Slab
148Rigid smooth centering & shuttering for R.C.C. works including false works and dismantlling them after casting including cost of materials complete. (A) R.C.C. Roof Slab
149(B) Column base
150(B) R.C.C. Roof Beam
151(C) R.C.C. Column
152(D) R.C.C. Plinth Beam
153(F) R.C.C. Lintel
154Supplying Cutting,bending un- coated HYSD bars,for reinforcement tying the grills and placing in position as required for the RCC works and for providing fan hooks hoisting and lowering,laying including cost,conveyance & taxes of SYSD bars and binding wires of 18 to 20 gauge required for the work and bending binding and tying the grills .
155Fly ash bricks masonary incm (1:6) after immersing the bricks 6 hrs. in water before use in Foundation and plinth having C.S. 75kg/cm2 in cluding all cost, carriage, royality etc. complete.
156Fly ash bricks masonary in cm (1:6) in Superstructure after immersing the bricks 6 hrs. In water before use in all floors having C.S. 75kg/cm2 in cluding all cost, carriage, royality etc. complete.
15712 mm thick cement plaster in cm (1:6) over brick wall finished smooth after raking out the joints including watering, curing with cost, conveyence etc.complete.
15816 mm thick cement plaster in cm (1:6) over brick wall finished smooth after raking out the joints including watering, curing with cost, conveyence etc.complete.In Side Wall Surface
1596mm thick cement plaster in C.M. [1:4] finished smooth to exposed R.C.C. work with cost of all materials labor etc. complete. In Side Ceilling Surface
160Finishing wall surface with plastic emulsion paint 2 coat over a coat of primer to the new surfaces of walls with including all cost as per direction of Engineer-in-charge.
161Finishing wall surface with weather coat 2 coat over a coat of primer to the new surfaces of walls with including all cost as per direction of Engineer-in-charge.
162Fixing of granite tiles in floors above 0.4m size of 20mm thick of approved make coformaing to I.S:13755 laid on on 25mm thick bed of Cement mortar 1:4 ( 1 Cement : 4 sand ) and filling joint with white Cement of approved quality in slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of tiles or stones. ( For new work)with cost of all materials labor etc. complete.
163Fixing of Granite tiles in dados, skirting riser of stepps 20cmx30cm / 20cmx20cm special plane / printed series of premium grade having thickness 6.5mm to 6.7mm confirming to IS 13753 on12 mm thick bed of Cement mortar 1:3 ( 1 Cement :3 sand ) jointed with neat Cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete excluding cost of tiles .
164Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame. shutters and all fitting and fixtures.
165Providing fitting, fixing of flase celling with Aluminium anodized T section No. 3215 with 2'-0\\" centre to centre, L section No. 1705 upto 15 micron on 4 walls to be fixed by means of steel screw and PVC plug and the Aluminium grid 2'-0\\" x 2'-0\\" suspended from ceilling including all cost of labour, T&P, hire charges of drilling machine, labour charges etc.complete.
166Finishing wall surface of walls with Acrylicwall putty (Water based ) of approved makeand finished smooth and even surface toreceive painting including cost of scaffoldingstaging charges with cost of all materialstaxes, labour T&P etc complete as per Engineer-in-charge
167Providing 2.5cm thick Grading Concrete in C.C (1:2:2) with 4.7 mm size CBHG Chips on new roof slab including cost of materials , labour, T&P all comp.
168WASTE DISPOSAL STOCKYARD CIVIL WORKS-Earth work in excavation of foundation trenches in all kids of soil including dressing and leavelling the bed upto the required depth and depositing the excaveted materials with all leads & lifts T&P Shoring and shuttering watering if necessary etc. complete as per directed by the Engineer-in-charge.
169Supplying and filling foundation and plinth with sand watered and rammed including cost, conveyance, royalties and taxes of all materials and cost of all labour, T&P required for the work etc. complete (measurement will be taken on finished compacted section only) as directed by the Engineer-in Charge.
170Cement concrete (1:3:6) using approved quality from approved quarry including lowering laying concrete watering and curing etc. as required levels laid in layers not exceeding(0'-6'') 15 cm thick including cost, conveyance,royalities and taxes of all materials and cost of all labour ,T&P required for the work etc. complete in all respect as directed by the Engineer-in-charge .
171R.C.C. work M-25 in grade having a minimum compressive strength (in work test) 250 kg/cm2 in 15cm cubes at 28 days using 12mm. & down grade hard granite C.B. chips of approved quality and from approved quarry including watering, lowering laying concrete, compacting with vibrators, curing for 28 days with smooth etc. complete.(B) Plinth Beam
172(F) R.C.C. Floor Slab Base
173Supplying Cutting,bending un- coated HYSD bars,for reinforcement tying the grills and placing in position as required for the RCC works and for providing fan hooks hoisting and lowering,laying including cost,conveyance & taxes of SYSD bars and binding wires of 18 to 20 gauge required for the work and bending binding and tying the grills .
174Fly ash bricks masonary incm (1:6) after immersing the bricks 6 hrs. in water before use in Foundation and plinth having C.S. 75kg/cm2 in cluding all cost, carriage, royality etc. complete.
175Fly ash bricks masonary in cm (1:6) in Superstructure after immersing the bricks 6 hrs. In water before use in all floors having C.S. 75kg/cm2 in cluding all cost, carriage, royality etc. complete.
17612 mm thick cement plaster in cm (1:6) over brick wall finished smooth after raking out the joints including watering, curing with cost, conveyence etc.complete.
17716 mm thick cement plaster in cm (1:6) over brick wall finished smooth after raking out the joints including watering, curing with cost, conveyence etc.complete.In Side Wall Surface
178Finishing wall surface with weather coat 2 coat over a coat of primer to the new surfaces of walls with including all cost as per direction of Engineer-in-charge.
179BOUNDARY WALL- Earth work in excavation of foundation trenches in all kids of soil including dressing and leavelling the bed upto the required depth and depositing the excaveted materials with all leads & lifts T&P Shoring and shuttering watering if necessary etc. complete as per directed by the Engineer-in-charge.
180Backfilling available excavated earth (excluding rock) in trenches , plinth , sides of foundations etc.in layers not exceeding 20cm in depth , consoildating each deposited layer by ramming and watering , lead upto 50m and lift upto 1.5m depth.
181Supplying and filling foundation and plinth with sand watered and rammed including cost, conveyance, royalties and taxes of all materials and cost of all labour, T&P required for the work etc. complete (measurement will be taken on finished compacted section only) as directed by the Engineer-in Charge.
182Cement concrete (1:3:6) using approved quality from approved quarry including lowering laying concrete watering and curing etc. as required levels laid in layers not exceeding(0'-6'') 15 cm thick including cost, conveyance,royalities and taxes of all materials and cost of all labour ,T&P required for the work etc. complete in all respect as directed by the Engineer-in-charge .
183R.C.C. work M-25 in grade having a minimum compressive strength (in work test) 150 kg/cm2 in 15cm cubes at 28 days using 12mm. & down grade hard granite C.B. chips of approved quality and from approved quarry including watering, lowering laying concrete, compacting with vibrators, curing for 28 days with smooth etc. complete.(A) Column Base
184(B) PlinthBend
185(C) R.C.C. Columns
186Rigid smooth centering & shuttering for R.C.C. works including false works and dismantlling them after casting including cost of materials complete.(A) R.C.C. Column base
187(A) R.C.C. Column
188(B) R.C.C. Plinth Beam
189Supplying Cutting,bending un- coated HYSD bars,for reinforcement tying the grills and placing in position as required for the RCC works and for providing fan hooks hoisting and lowering,laying including cost,conveyance & taxes of SYSD bars and binding wires of 18 to 20 gauge required for the work and bending binding and tying the grills .
190Fly ash bricks masonary incm (1:6) after immersing the bricks 6 hrs. in water before use in Foundation and plinth having C.S. 75kg/cm2 in cluding all cost, carriage, royality etc. complete.
191Fly ash bricks masonary in cm (1:6) in Superstructure after immersing the bricks 6 hrs. In water before use in all floors having C.S. 75kg/cm2 in cluding all cost, carriage, royality etc. complete.
19212 mm thick cement plaster in cm (1:4) over brick wall finished smooth after raking out the joints including watering, curing with cost, conveyence etc.complete.
19316 mm thick cement plaster in cm (1:4) over brick wall finished smooth after raking out the joints including watering, curing with cost, conveyence etc.complete.In Side Wall Surface
19416 mm thick cement plaster in cm (1:4) over brick wall finished smooth after raking out the joints including watering, curing with cost, conveyence etc.complete.In Side Wall Surface
195Finishing wall surface with weather coat painting 2 coat over a coat of primer to the new surfaces of walls with all cost complete as per Engineer-in-charge.
196Providing & fixing M.S. grill jally around the boundary wall above brick work in park including all cost etc. complete as per direction of Engineer in Charge.Boundary wall Fencing Fixed Grill
197Labour for fixing
198Supplying all materials , labour and ladder/scafolding T&P for art painting/concept/3d painting over wall as per direction of Engineer in Charge.
199Painting 2-coats with any approved paint over one coat of primer on new wood or iron work including cost of materials all complete as per direction of Engineer in Charge.
200DRAIN- Earth work in excavation in ordinary soil within 50mt. initial lead and 1.5mt initial lift including rough dressing and breaking clods to 5 cm. to 7 cm. size laying in layers not more than 30 cm.in depth as per MoRT&H Specifications etc complete.
201Filling foundation and plinth with sand well watered and rammed including cost conveyance royalty of sand and labour etc complete.
202P.C.C. (1:3:6) as per drawing & technical specification including cost of all materials labour T&P etc complete.
203R.C.C. work of M-25 Grade as per drawing & technical specification including cost of all materials labour T&P etc complete.
204Supplying fitting and placing uncoated HYSD bar in skin reinforcement complete as per drawing and technical specification etc. complete.
205Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame er -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certi acceptance of materials.NB:All the electrical,Fire fighting,HVAC,ELV drawings, Technical Data Sheets & make will be approved by SE R& B circle prior to execution of the work. Group A
206Group B
207Group C
208Supply and fixing of ISI marked modular type 2nos 6Amp socket with switch on suitable size of metal box and modular cover in front on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/-Schneider(Zencelo)/PANASONIC(VISION)
209Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.(Make :Legrand(Myrius)/-Schneider(Zencelo)/PANASONIC(VISION)
210Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover(anti bactorial & falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
211Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
212Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5)
213Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)
214Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB/Medical equipement) (4X6+2X4)
215Supply, delivery, installation, testing and commssioning of modular type TV Antenna Outlet Boards containing a ISI marked Modular TV Antenna/Telephone Socket fixed on Modular Concealed Box including connections and making good the damages caused complete as required and as per Dierction of Engineer-In-Charge.
216Supplying and fixing of following sizes of medium class PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/ BEC/ Precision/ Norpak- 20 MM
21725 MM
2184 Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of ,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years
219Supplying and fixing 40 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 3 years..
220Supplying and fixing 25 Amps rating,C series,10KA breaking capacity, DP, 240 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The MCB should be Replacement Warranty will be 3 years.
221Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years.
222Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: PHILIPS/HALONIX/WIPRO/LT).The luminaire should be Replacement Warranty will be 2 years
223Supply of 20 watt surface mounted indoor type battern LED Luminaire with LED GLARE FREE opal diffuser , IP20 Efficency 120-130lm/w luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 20 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years
224SITC of Sleek LED 10 watt MIRROR light fitting with having extruded polycarbonate housing,High optically efficient diffuser, complete with all accessoriesetc. directly on wall, and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years required.MAKE:PHILIPS/HALONIX/WIPRO/LT
225Supply of 36 watt 2'' x 2'' led surface mounted indoor type battern LED Luminaire with LED GLARE FREE opal diffuser , IP20 Efficency 120-130lm/w luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 36 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: PHILIPS/HALONIX/WIPRO/LT).The luminaire should be Replacement Warranty will be 2 years
226Supply of 80 watt BAY Light Surface mounted OUTDOOR type LED Luminaire with LED GLARE FREE opal diffuser , IP66 Efficency 120-130lm/w Lamp complete assembly With supply of required T&P and making connection from the suitable point outlet as per the Direction of Engineer-In-Charge.MAKE:PHILIPS/HALONIX/WIPRO/LT
227Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm 1700 cmh air delivery with louvers of exhaust fan in the existing wall, including fixing & conntection complete etc.as required and as per the direction of E.I.C..(Make-USHA (Model.Turbo HDEF 1400 RPM ISI)/Eq. model of /Havells/ ALmonrad/ Crompton
228Supplying, installation, testing and commssioning of 1200 mm sweep BLDC ceiling fan with aluminium blades having wattage not more than 28W and Air delivery ≥ 215(m3/min) Make-USHA(Teohnix)/Crompton(Energion Groove)/Havells(Efficiencia Neo ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. .(With fan Regulator)
229MAIN Panel: S/I/T&Commissioning of LT indoor floor mounted cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list. . 20X10MM Separate Aluminium Earth bus bar should be installed. Incoming: 125 Amp. 4P MCCB- 25 KA 1 No., R Y B LED Indicator- 3 Nos., Busbar- 04 numbers of 130Amps bus bar Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. Outgoing: 63 AMP 4P MCB 10 KA 5 NOS,Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 01 set of 0-1000Amps Ammeter with CTS.(DIGITAL)(Sicure/L&T,CT-KAPPA or equievalant make & model) WITH SPD 40 KA ( 3P+N) (iii) 01 set of 0-1000 voltmeter .(DIGITAL)(Sicure/L&T or equievalant make & model)
230SUB Panel: S/I/T&Commissioning of LT indoor floor mounted cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list. . 20X10MM Separate Aluminium Earth bus bar should be installed. Incoming: 63 Amp. 4P MCCB- 25 KA 1 No., R Y B LED Indicator- 3 Nos., Busbar- 04 numbers of 63Amps bus bar Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. Outgoing: 20 AMP DP MCB 10 KA 6 NOS,Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 01 set of 0-1000Amps Ammeter with CTS.(DIGITAL)(Sicure/L&T,CT-KAPPA or equievalant make & model) WITH SPD 40 KA ( 3P+N) (iii) 01 set of 0-1000 voltmeter .(DIGITAL)(Sicure/L&T or equievalant make & model)
231Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5 core x 50 sq mm Aluminium armoured Cable.(FOR FLOOR PANEL)
2323.5 core x 25 sq mm Aluminium armoured Cable.(FOR SUB PANEL)
233Supply and laying of 3C* 6sq mm Copper UnArmored Cable : SITC OF 3 core 6 sq mm multistand unarmored cable of fire retardant type with low dielectric losses and higher current carrying capacity, Higher short circuit rating. Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster
2343.5 core x 50 sq mm brass double compression gland and aluminium lugs
2353.5 core x 25 sq mm brass double compression gland and aluminium lugs
236Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
237Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
238Supplying,installation,testing & commissioning Of Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITH charcoal and salt) as required as per direction of Engg.-in-Charge. The entire earthing system should be Replacement Warranty will be 2 years
239Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
240Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
241Supplying of following Materials-.Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room.
242Supply and fixing of first aid box with medicines complete with medicine with three years expiry date to be fixed in Electrical control panel room..
243Supply installation of 33kV 3mm thick Class-C Rubber Mat as per IS-15652 and complete as per direction of Eng-in-charge.(Size-10mx1m)
244Danger Board. .
245Supply and delivery ,installation of 12'' x8'' size ILLUMINATED EXIT SIGNS With 3 hours battery back up including all conection as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-chargeMAKE:COSIGN/EQ
246Supply delivery ,installation andcommissioning of LED sign board superior make with star flex print signage board of ACRYLIC ALUMINIUM CHANNEL LETTERS OF ( PER LETTERS-30’’ - 28 PC ACRYLLIC letter in English,&odia of total size of (approx.) with white acryllic and ACP sheets.MAKE ALUDECOR LED 1.5 w of make HISIGN/interone/Brandlit,120 lumen,VOLT 12 V DC ,CRI>80,IP GRADE 66 Waterproof SMPS HISIGN IP 67/68 (BIS APPROVED) INPUT 220 V OUTPUT 12 V DC Wiring 1.5 sq mm FR grade (ISI MARKED ). LED for each letter having 3 row equally spaced. Colour of emission will be Green Colour with white background. The letter structure to be installed on the top of the Office building shall withstand 200 km/hr wind velocity, MS ANGLE as per need for sustainable fixture 2 inch Ms pipe fastened with concerte . LOGO, letter in, English andOdia will be fixed on terrace of the buildings.All materials shall be as per the technical specifications got approved before start of fabrication and installation.with all connection conforming to the relevant ISS and as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge.MAKE: COSIGN/EQ
247Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.NB:All the electrical,Fire fighting,HVAC,ELV drawings, Technical Data Sheets & make will be approved by SE R& B circle prior to execution of the work.
248Group B
249Group C
250Supply and fixing of ISI marked modular type 2nos 6Amp socket with switch on suitable size of metal box and modular cover in front on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/-Schneider(Zencelo)/PANASONIC(VISION)
251Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.(Make :Legrand(Myrius)/-Schneider(Zencelo)/PANASONIC(VISION)
252Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover(anti bactorial & falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
253Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
254Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5)
255Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)
256Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB/Medical equipement) (4X6+2X4)
257Supply, delivery, installation, testing and commssioning of modular type TV Antenna Outlet Boards containing a ISI marked Modular TV Antenna/Telephone Socket fixed on Modular Concealed Box including connections and making good the damages caused complete as required and as per Dierction of Engineer-In-Charge.
258Supplying and fixing of following sizes of medium class PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/ BEC/ Precision/ Norpak
25925 MM
2604 Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of ,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years
261Supplying and fixing 40 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 3 years..
262Supplying and fixing 25 Amps rating,C series,10KA breaking capacity, DP, 240 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The MCB should be Replacement Warranty will be 3 years.
263Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years.
264Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: PHILIPS/HALONIX/WIPRO/LT).The luminaire should be Replacement Warranty will be 2 years
265Supply of 20 watt surface mounted indoor type battern LED Luminaire with LED GLARE FREE opal diffuser , IP20 Efficency 120-130lm/w luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 20 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years
266SITC of Sleek LED 10 watt MIRROR light fitting with having extruded polycarbonate housing,High optically efficient diffuser, complete with all accessoriesetc. directly on wall, and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years required.MAKE:PHILIPS/HALONIX/WIPRO/LT
267Supply of 30 watt led linear surface mounted indoor type battern LED Luminaire with LED GLARE FREE opal diffuser , IP20 Efficency 120-130lm/w luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 36 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: PHILIPS/HALONIX/WIPRO/LT).The luminaire should be Replacement Warranty will be 2 years
268Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm 1700 cmh air delivery with louvers of exhaust fan in the existing wall, including fixing & conntection complete etc.as required and as per the direction of E.I.C..(Make-USHA (Model.Turbo HDEF 1400 RPM ISI)/Eq. model of /Havells/ ALmonrad/ Crompton
269Supplying, installation, testing and commssioning of 1200 mm sweep BLDC ceiling fan with aluminium blades having wattage not more than 28W and Air delivery ≥ 215(m3/min) Make-USHA(Teohnix)/Crompton(Energion Groove)/Havells(Efficiencia Neo ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. .(With fan Regulator)
270MAIN Panel: S/I/T&Commissioning of LT indoor floor mounted cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list. . 20X10MM Separate Aluminium Earth bus bar should be installed. Incoming: 125 Amp. 4P MCCB- 25 KA 1 No., R Y B LED Indicator- 3 Nos., Busbar- 04 numbers of 130Amps bus bar Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. Outgoing: 63 AMP 4P MCB 10 KA 5 NOS,Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 01 set of 0-1000Amps Ammeter with CTS.(DIGITAL)(Sicure/L&T,CT-KAPPA or equievalant make & model) WITH SPD 40 KA ( 3P+N) (iii) 01 set of 0-1000 voltmeter .(DIGITAL)(Sicure/L&T or equievalant make & model)
271SUB Panel (cold storage): S/I/T&Commissioning of LT indoor floor mounted cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list. . 20X10MM Separate Aluminium Earth bus bar should be installed. Incoming: 63 Amp. 4P MCCB- 25 KA 1 No., R Y B LED Indicator- 3 Nos., Busbar- 04 numbers of 63Amps bus bar Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. Outgoing: 20 AMP DP MCB 10 KA 3 NOS,20 AMP 4P MCB 10 KA 3 NOS, Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 01 set of 0-1000Amps Ammeter with CTS.(DIGITAL)(Sicure/L&T,CT-KAPPA or equievalant make & model) WITH SPD 40 KA ( 3P+N) (iii) 01 set of 0-1000 voltmeter .(DIGITAL)(Sicure/L&T or equievalant make & model)
272Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5 core x 50 sq mm Aluminium armoured Cable.(FOR FLOOR PANEL)
2733.5 core x 25 sq mm Aluminium armoured Cable.(FOR SUB PANEL)
274Supply and laying of 3C* 6sq mm Copper UnArmored Cable : SITC OF 3 core 6 sq mm multistand unarmored cable of fire retardant type with low dielectric losses and higher current carrying capacity, Higher short circuit rating. Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster
2753.5 core x 50 sq mm brass double compression gland and aluminium lugs
2763.5 core x 25 sq mm brass double compression gland and aluminium lugs
277Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
278Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
279Supplying,installation,testing & commissioning Of Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITH charcoal and salt) as required as per direction of Engg.-in-Charge. The entire earthing system should be Replacement Warranty will be 2 years
280Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
281Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
282Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room.
283Supply and fixing of first aid box with medicines complete with medicine with three years expiry date to be fixed in Electrical control panel room..
284Supply installation of 33kV 3mm thick Class-C Rubber Mat as per IS-15652 and complete as per direction of Eng-in-charge.(Size-10mx1m)
285Danger Board. .
286Supply and delivery ,installation of 12'' x8'' size ILLUMINATED EXIT SIGNS With 3 hours battery back up including all conection as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-chargeMAKE:COSIGN/EQ
287Supply delivery ,installation andcommissioning of LED sign board superior make with star flex print signage board of ACRYLIC ALUMINIUM CHANNEL LETTERS OF ( PER LETTERS-30’’ - 28 PC ACRYLLIC letter in English,&odia of total size of (approx.) with white acryllic and ACP sheets.MAKE ALUDECOR LED 1.5 w of make HISIGN/interone/Brandlit,120 lumen,VOLT 12 V DC ,CRI>80,IP GRADE 66 Waterproof SMPS HISIGN IP 67/68 (BIS APPROVED) INPUT 220 V OUTPUT 12 V DC Wiring 1.5 sq mm FR grade (ISI MARKED ). LED for each letter having 3 row equally spaced. Colour of emission will be Green Colour with white background. The letter structure to be installed on the top of the Office building shall withstand 200 km/hr wind velocity, MS ANGLE as per need for sustainable fixture 2 inch Ms pipe fastened with concerte . LOGO, letter in, English andOdia will be fixed on terrace of the buildings.All materials shall be as per the technical specifications got approved before start of fabrication and installation.with all connection conforming to the relevant ISS and as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge.MAKE: COSIGN/EQ
288SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit.
289SITC of Cat6 I/O with Dual Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit
290SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax, Legrand, Panduit
291SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(1 mtr length)
292SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(2 mtr length)
293SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax, Legrand, Panduit
294SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19” ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Pigtail, Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR-326-Core . Make: Systimax, Legrand, Panduit
295SITC of OFC Patch Cor, SM (OS2), Duplex LC-SC, LC-LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Systimax, Legrand, Panduit
296SITC of 1G-LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 20 KM. Make: Cisco, Digisol, Netgear
297SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP
298SITC of 9U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Legrand
299SITC of 24U 600/650D UL Listed Floor mount Rack with Front perforated door with 3 point lock, Rear mesh door with Cam lock and 3inch Castor Wheel included with 2 no 6/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Length, 4nos 1U Metal Cable manager with Plastic cable loops, 2nos CFM FAN set, 1no Monitor Tray - Ventilation - 495W - 375D and H/W screw920sets). Make:Valrack, Rittal, Legrand
300Supply and installation of Dual band 802.11ax WiFi6 Dual Band Access Point. Complying PoE+ for power, with inbuilt on premise virtual controller as well cloud based controlling and administration of WiFi systems All hardware should supplied with necessary mounting brackets and IN power cord with 3 years of comprehensive onsite warranty. Make: Cisco/Digisol/Netgear
301Supply ,installation ,testing & commissioning of 5KVA UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sequence corrector of 3ph in put to 3 ph output,415V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 26AH, 20 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric/APC/ Vertiv/) , as per direction of Engg.-in-Charge. Warranty period of all accessories & component & system must be 2 years & complete test certificate must be submitted along with ups including component list & SLD. for services building
302Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR Fixed Lens Dome/Bullet Camera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, triple stream at various resolution & Frame Rates, Min. Illumination required 0.007 lux (color), 0 Lux IR On, 2 IR LEDs, Smart IR with upto 50m IR distance, Auto ICR (Infrared Cut Filter) 120dB True WDR, S/N Ratio 50db, Shutter Speed 1/8 - 1/30,000; Adavance Video Compression technology such as H.265, H.264 & MJPEG , Fixed Lens 2.8mm, Field of View FoV H:90°, V:62°, BLC, HLC, WDR, 3DNR, White Balance - Auto/Manual, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 4 Privacy Mask, 8 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2-Way Audio Full Duplex Line IN/Out, 256GB SD card support, Alarm: 1In/1out, PoE (802.3 af) and 12V DC, Max 5W, IP 66/67 & IK10 with Die Cast Aluminium Housing, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000)/NDA/STQC compliant. Make-Honeywell(Series 50), Pelco, Axis,Bosch
303Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR motorized Lens Bullet Camera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, triple stream at various resolution & Frame Rates, Min. Illumination required 0.007 lux (color), 0 Lux IR On, 4 IR LEDs Smart IR with upto 50m IR distance, Auto ICR (Infrared Cut Filter) 120dB True WDR, S/N Ratio 50db, Shutter Speed 1/8 - 1/30,000; Adavance Video Compression technology such as H.265 & H.264 High Profile & MJPEG , Triple stream, Fixed Lens 2.8mm, BLC, HLC, 3DNR White Balance, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 4 Privacy Mask, 8 Region Of Intreset, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, Dual channel Audio, Alarm: 1In/ 1out, 256GB SD card support, PoE (802.3 af) and 12V DC, Max 6W, IP 66, IK 10 vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S/G/T compliant, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000)/NDA /STQC compliant.Make-Honeywell(Series 50), Pelco, Axis,Bosch
304Supply , Installation, testing , commissioning of 16 Channel NVR with 4 SATA; 384 Mbps incoming bandwidth, Up to 8 Megapixels Resolution Display and Recording, H.265 video compression technology with real time encoding, Full function CMS (Central monitoring software) supported, Two way audio supported, Dual streaming technology to encode recording stream and network stream separately, Supports remote monitoring on Mobile Client (Android, IOS), TCP / IP, PPPoE, DHCP, DNS, DDNS, UPnP, NTP, SMTP, Time/ Date, Alarm, Motion Detection & Exact Search (accurate to second), Record Snapshot, FTP, Preset Calling, Email notification supported, Manual/ Alarm/ Motion Detection/ Continuous, CE, FCC, RoHS).STQC compliant Make-Honeywell series 50/Pelco/Axis/Bosch
305Supply, Installation,Testing & Commisioning of Surveliance 5 TB HDDMake:- WD/Segate/Toshiba
306SITC of 55\\" UHD IPS Commercial Digital Display for Small Size Discussion & Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms, Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty. Make: LG/Samsung/Sony
307Supply delivery, installation and testing of 120 watt PREMISES Light Surface mounted OUTDOOR type LED Luminaire with LED GLARE FREE opal diffuser , IP66 Efficency 120-130lm/w Lamp complete assembly With supply of required T&P and making connection from the suitable point outlet as per the Direction of Engineer-In-Charge. .The luminaire should be Replacement Warranty will be 2 years MAKE:PANASONIC/PHILIPS/HALONIX/CROMPTON/WIPRO/HAVELLS/LT
308Supply of 6 mtr long hot dip galvanized Octagonal pole having base dia of 155 mm and top dia of 70 mm and plate thick ness of 4 mm or more. complete with base plate 260x260x16 mm and 4 nos. Jtype En 8 grade foundation bolts (M24X750 mm) to withstand 180 KM / HR or more wind speed considering the weight & dimension of 1 nos 120 W light to be fitted in the top of the pole .Construction of RCC foundation by using M20 grade RCC and Fe415 grade reinforcement in the foundation by considering the SBC as 10 T per sq mtr and fixing 4 nos. EN8 grade foundation bolts in that foundation The bidder shall also furnish wind load test report of the solar fixture and wind load test of the pole considering the weight and dimension of 1 no 120 W light to be fitted in the pole to sustain wind speed of 180km/hr or more from third party /central/state govt accredited NABL lab after award of the work.The reports shall be vetted and approved by concerned civil division/circle.(Make - Bajaj/RR ispat//Valmont/Vakrangee/Utkarsh)
309Supply delivery, installation, testing & commissioning of following types of 11 watt LED based BOLLARD LIGHT path direction refelector with pc diffuser aluminium pipe housing with CCT:3000K IP66 Height -600 MM smartely designed asymmetric lighting for landscape complete etc.as required and as per the direction of E.I.C. MAKE: PANASONIC/ PHILIPS/ Halonix/ CROMPTON/ WIPRO/ HAVELLS/ LT
310STREET LIGHT: S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 63A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,,04 nos 10A 4P MCB,C,10KA as outgoing MCB legrand dx3/ schneider acti9 A9N/ Siemens betaguard/ ABB ( SB 200) as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 1 years of acceptance of materials
311Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge.4 core x 16 sqmm A2XFY
3124 core x 6 sqmm A2XFY
313Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
314Supply ,Installation, testing and commissioning of 2 Pole mounted DP providing I no 11kv, GOC in accordence with ie rules& local authority specifications and drawing and comprasing the following 2 nos of 11 mtr long MS pole complete with pole,excavation,MS foundation and back filling complete MS STEEL chaneel/angle iron etc 1 set of cross arms,branching,clamps,painting, 1 set of insulator complete with spindles and hardware & 11 kv ASCR CONDUCTOR COMPLETE AS REQUIRED 2 set 150 mm dia 3m long gi pipe earthing with 25 x 6 mm gi earth strip complete as required 1 nos 150 mm dia GI pipe class B for XLPE CABLE PROTECTION as required
315Supply ,Installation, testing and commissioning of 100 KVA , 3 phase 11 kv/433 v,50 hz ,3 phase delta /star connected ONAN transformer with DYN -11 vector group suitable for out door the transformer shall have off load taps in steps +/- 2.5% and +/- 5% core type double wound ,WITH AVR suitable for outdoor and having no load ratio 11/.440 KV with copper windings connected in delta/ star L.V. side(As per 1180 technical specification) complete with transformer oil for first filling and standard accessories on a platform complete etc as required HT SIDE: 11 KV ,3C X120MM XLPE CABLE ,LT SIDE:,2 X 3.5 X300MM XLPE CABLE Transformer shall have provided with winding over temperature indication and trip devices.WITH PANEL
316Supply, Transportation, erection, testing and commissioning of 3 Phase, 415V, 50Hz, water cooled multi cylinder diesel generator set with alternator of 50 KVA ( Make -Kirloskar / Jakson/) out put contineous rating directly coupled Engine and Alternator with guard and mounted on a common base plate of Robust construction and complete with AMF panel having IP-52 protection, Acoustic Enclosure as per CPCB IV+ norms , sound absorbing material, to restrict sound level up to 75 dB up to 1 mtr distance and as per CPCB IV+ norms etc as per following specifications mentioned below. Warrentee period must be 2 years
317Supply and fixing of tensile fabric with fabricated tensile on roofing including all other necessary fittings and labour as per approved drawing, instructed by site-incharge
318Supply and erection of MS structural steel work as per approved drawing, instructed by site-incharge
319Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge.Ground Floor25mm dia PVC ASTM pipe (sch-80)
32032mm dia PVC ASTM pipe (sch-80)
32150mm dia PVC ASTM pipe (sch-80)
32225mm dia PVC ASTM pipe (sch-80)
32332mm dia PVC ASTM pipe (sch-80)
32450mm dia PVC ASTM pipe (sch-80)
32532mm dia PVC ASTM pipe (sch-80)
32650mm dia PVC ASTM pipe (sch-80)
327Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor CPVC pipes conforming to IS:15778 having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00. spacing. This includes Jointing of pipes & fittings with one step CPVC solvent cement and testing of Joints all complete as per specification and direction of the Engineer in charge.Ground Floor20mm dia CPVC pipe
32825mm dia CPVC pipe
32932mm dia CPVC pipe
33020mm dia CPVC pipe
33125mm dia CPVC pipe
33232mm dia CPVC pipe
333Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge. 15 mm dia 2 WAY BIB COCK WITH WALL FLANGE (ALI-CHR-85041 Jaquar Make)
33415mm dia CP Health Faucet (ALD-CHR-577)
33515 mm dia CP Bib cock( VGP-CHR-81037 Jaquar make )
33615mm dia CP ANGULAR STOP COCK WITH WALL FLANGE (FLR-MCH-5053N Jaquar Make )
33720mm dia CP CONCEALED STOP COCK EXT HVY WTH WITH FLANGE( FLR-MCH-5083KPM Jaquar ) Make
33832mm dia CP Bottle trap (Jaquar make)-ALD -CHR-769L -300x190cm
339Auto closing concealed urinal flush valve(Jaquar make)-PRS-CHR-077
340URINAL PARTITION ST.450mm(JSE-CHR-810US450X)
34115 mm dia CP pillar cock auto closing system(Jaquar)-PRS-CHR-031
342Soap Dispenser with glass bottle(ACN-CHR-1135N)
343CP soap Dish holder (Jaquar make)-AKP -ABR-35731P
344Towel Ring Round - (As Per Jaquar,Cat no.:ACN-CHR-1121BN)
345600mm long CP towel rail(Jaquar)-ACN-IVY-1111NM
34625mm dia brass or gun metal fullway valve (Shakti Make)
34732mm dia brass or gun metal fullway valve (Shakti Make)
34850mm dia brass or gun metal fullway valve (Shakti Make)
34915mm dia CP flange
35015mm dia CP extension piece
351C.P. Waste 11/4\\"
352Supplying all materials, labour, T&P and fitting and fixing CP shower with 15mm or 20mm inlet with CP shower arm including polishing all complete as per specification and direction of the Engineer in charge.15mm dia CP revolving shower With shower arm(Jaquar)OHS-CHR-1985+SHA-CHR-477
353Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge 10 litres capacity pvc low level cistern with 32mm dia CP long flush bend Slimline white (Hindware / Parryware Make)
354160mm dia pvc (SWR) pipe clkss A (with wall thickness of 3.2 mm to 3.8mm)
355110mm dia pvc (SWR) pipe clkss A (with wall thickness of 3.2 mm to 3.8mm)
356110mm U-PVC door tee
357110mm U-PVC Plain tee
358110mm U-PVC door bend
359110mm U-PVC plain bend
360110mm dia U-PVC 'P' trap
361110mm dia U-PVC Plain Shoe Bend
362110mm dia U-PVC offset with out ear
363110mm dia U-PVC cowl
364125mm dia CP grating
365Grab bar 300MM (Jaquar make)AHS-CHR-1501
366Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge. European water closet with ‘S’ trap plain (Hindware)No.20079
367Supplying all materials, labour, T&P and fixing bowl pattern urinal conforming to IS:771-part-3-1985 of the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge. Half stall urinal (Parryware / Hindware make)
36815mm dia urinal spreader
36932mm dia C.P. dome waste
370Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the Engineer in charge. Under counter basin JAQUAR MAKE SLS-WHT-6601
371Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge. Design mirror
372Pur Panel (125 mm and 60mm ) and all accessories
373Refrigeration Unit for Freezer Room
374Refrigeration Unit for Chiller Room
375Water Cooler for Drinking Purpose Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56598079
AUTHORITY Local Bodies
TENDER VALUE 8.01 Crore
LAST DATE 12-08-2026
Authority
Authority Name Municipal Bodies
Work Description Tender for Construction Of Krushak Bazar And Hata At Mining Road In Keonjhargarh Municipality
Basic Detail
Tender No ODULB_KGM_02/2026-2027
Bidding Type Tender
Location
City Kendujhar
State Odisha
Key Dates
Publish Date 22 Jul 2026
Submission Date 12 Aug 2026
Open Date 17 Aug 2026
Finance
Tender Value 8.01 Crore
Tender Fee 11800
EMD 8.01 Lakhs
Exemption Available
Document List
594778c1-c8e4-459d-a98c-aaa0210c70e6.html
BOQ_602859.xls
DTCN.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Aug 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

594778c1-c8e4-459d-a98c-aaa0210c70e6.html

xls

BOQ_602859.xls

pdf

DTCN.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders