Tender For Construction Of Electrical Work Of 2X5 Mva 33/11 Kv Sub-Station At Village- Bhageena-Bhandari And One No 33 Kv Bay At 33 Kv Sub-Station Khetikhan (Ch Awat) Under The Head Of Capital (I.R.) Under Eswd, Kathgodam Haldwani. (Rates Should Be Q
Tender Overview
Project Description
Tender for Construction Of Electrical Work Of 2X5 Mva 33/11 Kv Sub-Station At Village- Bhageena-Bhandari And One No 33 Kv Bay At 33 Kv Sub-Station Khetikhan (Ch Awat) Under The Head Of Capital (I.R.) Under Eswd, Kathgodam Haldwani. (Rates Should Be Quoted Without Gst) (Gst Will Paid Extra)
BOQ
| Sl. No. | Item Description |
| 1 | Annexure-A (LABOUR CHARGES) |
| 2 | CEMENT PLASTER WORK |
| 3 | FABRICATION OF STRUCTURE |
| 4 | CEMENT PLASTER WORK (ITEM 2) |
| 5 | EXCAVATION IN SOIL IN HILLY AREA/RIVER BED BY MECHANICAL MEANS I.E. BACKHOE LOADER |
| 6 | LAYING, SPREADING AND STRINGING BUS BAR CONDUCTOR BY ACSR PATH CONDUCTOR WITH MAKING ALL CONNECTIONS |
| 7 | Jointing and fixing of cable jointing kit indoor/outdoor 11 KV XLPE heat shrinkable cable boxes |
| 8 | LAYING OF 11 KV CABLE |
| 9 | ERECTION OF 33 KV VCB |
| 10 | PAINTING OF ISOLATOR/LA/CT/STRUCTURE COMPLETE |
| 11 | FABRICATION OF STRUCTURE (ITEM 2) |
| 12 | FENCING OF YARD |
| 13 | Installation / Fixing of 33 Kv Isolator on structure at 33 Kv switchyard with proper alignment & Connections with busbar complete. |
| 14 | PAINTING OF ISOLATOR/LA/CT/STRUCTURE COMPLETE (ITEM 2) |
| 15 | CEMENT PLASTER WORK (ITEM 3) |
| 16 | ERECTION OF LINE ISOLATOR STRUCTURE WITH INST. |
| 17 | Grouting of structure in CC 1:3:6 in size (2x1.1x0.3x0.3) mtr. |
| 18 | CEMENT PLASTER WORK (ITEM 4) |
| 19 | Grouting of structure in CC 1:3:6 in size (2x1.1x0.3x0.3) mtr. (ITEM 2) |
| 20 | RCC 1:1.5:3 |
| 21 | FABRICATION OF STRUCTURE (ITEM 3) |
| 22 | Laying of MS bar 32 mm for making earth mat in switchyard area after fabrication / cutting in required size, laying at 2 mtr apart, also in crossing (Making Net), proper welding at each joint, laying at least 1 mtr depth in switchyard area |
| 23 | BRICK WORK WITH COMMON BURNT CLAY BRICKS WITH CEMENT MORTAR 1:4 |
| 24 | FABRICATION OF STRUCTURE (ITEM 4) |
| 25 | ERECTION OF STAY POST |
| 26 | Erection of 11 KV VCB (O/G or B/C or I/C) Panel in all respect, making connection, testing etc in all respect at erection site |
| 27 | FABRICATION OF STRUCTURE |
| 28 | FIXING OF 33 KV LIGHTNING ARRESTOR |
| 29 | Erection charges of structure |
| 30 | CEMENT PLASTER WORK |
| 31 | Grouting of structure in CC 1:3:6 in size (2x1.1x0.3x0.3) mtr. |
| 32 | EXCAVATION IN SOIL IN HILLY AREA/RIVER BED BY MECHANICAL MEANS I.E. BACKHOE LOADER (ITEM A) |
| 33 | EXCAVATION IN SOIL IN HILLY AREA/RIVER BED BY MECHANICAL MEANS I.E. BACKHOE LOADER (ITEM B) |
| 34 | FIXING OF SODIUM/LED LIGHT AT YARD |
| 35 | FABRICATION OF STRUCTURE (ITEM 2) |
| 36 | EXCAVATION IN SOIL IN HILLY AREA/RIVER BED BY MECHANICAL MEANS I.E. BACKHOE LOADER (ITEM C) |
| 37 | EXCAVATION IN SOIL IN HILLY AREA/RIVER BED BY MECHANICAL MEANS I.E. BACKHOE LOADER (ITEM D) |
| 38 | ERECTION OF BUS GANTRY |
| 39 | CEMENT PLASTER WORK (ITEM 2) |
| 40 | Grouting of structure in CC 1:3:6 in size (2x1.1x0.3x0.3) mtr. (ITEM 2) |
| 41 | Grouting of structure in CC 1:3:6 in size (2x1.1x0.3x0.3) mtr. (ITEM 3) |
| 42 | PROVIDING AND LAYING IN POSITION CEMENT CONCRETE OF SPECIFIED GRADE EXCLUDING THE COST OF CENTERING AND SHUTTERING - ALL WORKS UPTO PLINTH LEVEL (I) 1:4:8 (1 - CEMENT; 4 - COARSE SAND; 8 - GRADED STONE AGGREGATE 40MM NOMINAL SIZE) FOUNDATION |
| 43 | FABRICATION OF R.S. JOIST 175X85 SQ.MM. |
| 44 | Erection of SP-10 single support pole in proper level and alignment along with fixing of all accessories like top channel & clamps as per RESPO manual |
| 45 | SUPPLY & ERECTION OF GRAVEL PITCHING OF SIZE 1/2\\" TO 3/4\\" (20X30X0.1) |
| 46 | PAINTING OF 33 KV CT STRUCTURE |
| 47 | PAINTING OF VCB PANELS (OUTER SURFACE AND INTERIOR LOWER)AREA WHERE VCB IS PLACED) |
| 48 | EXCAVATION IN SOIL IN HILLY AREA/RIVER BED BY MECHANICAL MEANS I.E. BACKHOE LOADER (ITEM A) |
| 49 | Grouting of structure in CC 1:3:6 in size (2x1.1x0.3x0.3) mtr. (ITEM A) |
| 50 | Grouting of structure in CC 1:3:6 in size (2x1.1x0.3x0.3) mtr. (ITEM B) |
| 51 | Earth filling under floor and in sub-station area including cost of earth. Earth to be obtained from outside the corporation area including its cartage and ramming, watering, dressing in 20 cm's thick layers including cost of earth with all lead and lift |
| 52 | EXCAVATION IN SOIL IN HILLY AREA/RIVER BED BY MECHANICAL MEANS I.E. BACKHOE LOADER (ITEM B) |
| 53 | ERECTION OF 33KV CONTROL PANEL (FEEDER/T/F) |
| 54 | Cartage of the 33 KV VCB, feeder panels(O/D), T/F Control panel from store center to construction site with loading and unloading at both points. (Distance 0-20 Km) |
| 55 | Erection charges of structure |
| 56 | COMPLETE WIRING OF BREAKER BY PROVIDING FERULE ETC |
| 57 | ERECTION OF FLEXIBLE CU. CONN. 500X50 MM |
| 58 | MAKING CABLE TRENCH |
| 59 | FABRICATION OF STRUCTURE (ITEM A) |
| 60 | Erection of SP-33 double support pole in proper level and alignment along with fixing of all accessories like top channel, X bracings, & clamps as per RESPO manual |
| 61 | EXCAVATION IN SOIL IN HILLY AREA/RIVER BED BY MECHANICAL MEANS I.E. BACKHOE LOADER (ITEM C) |
| 62 | Painting of T.G. with one coat of Red oxide paint & 2 coats of Aluminum paints of best quality I.S.I. mark. |
| 63 | CEMENT PLASTER WORK |
| 64 | EXCAVATION IN SOIL IN HILLY AREA/RIVER BED BY MECHANICAL MEANS I.E. BACKHOE LOADER (ITEM D) |
| 65 | FABRICATION OF STRUCTURE (ITEM B) |
| 66 | FIXING OF ACCESSORIES |
| 67 | Grouting of structure in CC 1:3:6 in size (2x1.1x0.3x0.3) mtr. (ITEM C) |
| 68 | ERECTION OF TERMINAL GANTRY |
| 69 | Earthing with two Nos. G.I earth plates 600mm x 600mm x 6mm thick (1.5)meter minimum in between distance)including accessories and p rovidingdouble masonry enclosure with coverplate having locking arrangement andwatering pipe of 3 meter long etc. With |
| 70 | Erection charges of structure |
| 71 | EARTHING OF STRUCTURE USING GI STRIP (ITEM A) |
| 72 | PROVIDING AND LAYING IN POSITION CEMENT CONCRETE OF SPECIFIED GRADE EXCLUDING THE COST OF CENTERING AND SHUTTERING - ALL WORKS UPTO PLINTH LEVEL (I) 1:4:8 (1 - CEMENT; 4 - COARSE SAND; 8 - GRADED STONE AGGREGATE 40MM NOMINAL SIZE) FOUNDATION (ITEM A) |
| 73 | CEMENT PLASTER WORK (ITEM A) |
| 74 | CEMENT PLASTER WORK (ITEM B) |
| 75 | BRICK WORK WITH COMMON BURNT CLAY BRICKS WITH CEMENT MORTAR 1:4 |
| 76 | PROVIDING AND LAYING IN POSITION CEMENT CONCRETE OF SPECIFIED GRADE EXCLUDING THE COST OF CENTERING AND SHUTTERING - (I) 1:2:4 (1 CEMENT; 2 - COARSE SAND; 4 - GRADED STONE AGGREGATE 20MM NOMINAL SIZE) ROAD REPAIRING / OTHER WORK |
| 77 | RR masonry work in 1:6 ratio |
| 78 | PROVIDING AND LAYING IN POSITION CEMENT CONCRETE OF SPECIFIED GRADE EXCLUDING THE COST OF CENTERING AND SHUTTERING - ALL WORKS UPTO PLINTH LEVEL (I) 1:4:8 (1 - CEMENT; 4 - COARSE SAND; 8 - GRADED STONE AGGREGATE 40MM NOMINAL SIZE) FOUNDATION (ITEM B) |
| 79 | Erection of SP-33 double support pole in proper level and alignment along with fixing of all accessories like top channel, X bracings, & clamps as per RESPO manual |
| 80 | EARTHING OF STRUCTURE USING GI STRIP (ITEM B) |
| 81 | ERECTION OF 24 VOLT BATTERY SET |
| 82 | CEMENT PLASTER WORK (ITEM C) |
| 83 | EARTHING OF STRUCTURE USING GI STRIP (ITEM C) |
| 84 | Installation / Fixing of 33 Kv Isolator on structure at 33 Kv switchyard with proper alignment & Connections with busbar complete. |
| 85 | CEMENT PLASTER WORK (ITEM A) |
| 86 | CEMENT PLASTER WORK (ITEM B) |
| 87 | Erection of cable stand neutral stand including fabrication cutting and welding work. |
| 88 | EXCAVATION IN SOIL IN HILLY AREA/RIVER BED BY MECHANICAL MEANS I.E. BACKHOE LOADER (ITEM A) |
| 89 | ERECTION OF 33/0.433KV S/S TRANSFORMER |
| 90 | PAINTING OF DOUBLE POLE (SP-33) |
| 91 | FABRICATION OF STRUCTURE |
| 92 | Laying and erection of L.T. PVC single lead Cable including crimping of lugs of size 1x240, 400, 630 Sq.mm etc. (Including all cost of material) |
| 93 | EXCAVATION IN SOIL IN HILLY AREA/RIVER BED BY MECHANICAL MEANS I.E. BACKHOE LOADER (ITEM B) |
| 94 | BRICK WORK WITH COMMON BURNT CLAY BRICKS WITH CEMENT MORTAR 1:4 |
| 95 | TESTING OF TRANSFORMER / VCB / PANEL |
| 96 | PAINTING OF ISOLATOR/LA/CT/STRUCTURE COMPLETE (ITEM A) |
| 97 | FIXING OF 33 KV FUSE SET |
| 98 | Cartage of 5/8 MVA Power transformer by road (loading/unloading/shifting to be charged extra) (151-200 KM) |
| 99 | EXCAVATION IN SOIL IN HILLY AREA/RIVER BED BY MECHANICAL MEANS I.E. BACKHOE LOADER (ITEM C) |
| 100 | Cartage of other material (other than poles) by vehicle from Store Center to nearest construction site Store including loading and unloading at both ends (distance 151-200 Km) |
| 101 | PAINTING OF ISOLATOR/LA/CT/STRUCTURE COMPLETE (ITEM B) |
| 102 | INSTALLATION OF FIRE EXTINGUISHERS |
| 103 | PROVIDING AND LAYING IN POSITION CEMENT CONCRETE OF SPECIFIED GRADE EXCLUDING THE COST OF CENTERING AND SHUTTERING - ALL WORKS UPTO PLINTH LEVEL (I) 1:4:8 (1 - CEMENT; 4 - COARSE SAND; 8 - GRADED STONE AGGREGATE 40MM) NOMINAL SIZE).( FOUNDATION |
| 104 | PROVIDING AND LAYING IN POSITION CEMENT CONCRETE OF SPECIFIED GRADE EXCLUDING THE COST OF CENTERING AND SHUTTERING - ALL WORKS UPTO PLINTH LEVEL (I) 1:4:8 (1 - CEMENT; 4 - COARSE SAND; 8 - GRADED STONE AGGREGATE 40MM NOMINAL SIZE) FOUNDATION |
| 105 | Erection charges of structure |
| 106 | Digging of trench of size 0.60x0.15x1.5 mtr. and laying of underground 33 KV XLPE cable with making of brick housing and filling of sand including filling of earth with ramming & repairing of road including cost of cement sand and stone blast |
| 107 | STEEL (REINFORCEMENT) |
| 108 | ERECTION OF 24 VOLT BATTERY CHARGER |
| 109 | ERECTION OF SUB-STATION NAMED BOARD |
| 110 | ERECTION OF NAME PLATES |
| 111 | INSTALLATION OF DCDB COMPLETE ON SURFACE OR WALL WITH THE HELP OF WALL ANCHOR BOLT FASTENERS 4 NOS. COMPLETE TESTING AND COMMISSIONING OF DCDB AS PER SITE REQUIREMENT AND NARRATED BY ENGINEER IN CHARGE OF THE WORK |
| 112 | INSTALLATION OF ACDB COMPLETE ON SURFACE OR WALL WITH THE HELP OF WALL ANCHOR BOLT FASTENERS 4 NOS. COMPLETE TESTING AND COMMISSIONING OF ACDB AS PER SITE REQUIREMENT AND NARRATED BY ENGINEER IN CHARGE OF THE WORK |
| 113 | Jointing and fixing of cable jointing kit indoor/outdoor 33 KV XLPE heat shrinkable cable boxes |
| 114 | FIXING OF 33 KV LINE ISOLATOR VERTICAL TYPE ON ST POLE |
| 115 | ERECTION OF BUS BAR |
| 116 | FABRICATION OF STRUCTURE (ITEM A) |
| 117 | SHIFTING OF 5 MVA T/F |
| 118 | FABRICATION OF STRUCTURE (ITEM B) |
| 119 | Erection of (8.5) MVA T/F at transformer plinth & erection of all accessories i.e. radiators, conservator tank, vent pipe etc., with the help of special type of T&P / crane etc. fitting cable etc. and refilling the fresh oil inradiator and conservator |
| 120 | FIXING OF 33 KV FUSE SET |
| 121 | PROVIDING AND LAYING IN POSITION CEMENT CONCRETE OF SPECIFIED GRADE EXCLUDING THE COST OF CENTERING AND SHUTTERING - (I) 1:2:4 (1 CEMENT; 2 - COARSE SAND; 4 - GRADED STONE AGGREGATE 20MM NOMINAL SIZE) ROAD REPAIRING / OTHER WORK |
| 122 | PROVIDING AND LAYING IN POSITION CEMENT CONCRETE OF SPECIFIED GRADE EXCLUDING THE COST OF CENTERING AND SHUTTERING - ALL WORKS UPTO PLINTH LEVEL (I) 1:4:8 (1 - CEMENT; 4 - COARSE SAND; 8 - GRADED STONE AGGREGATE 40MM NOMINAL SIZE) FOUNDATION |
| 123 | PAINTING OF BUS GANTRY |
| 124 | FABRICATION OF STRUCTURE |
| 125 | Erection charges of structure |
| 126 | FIXING AND ERECTION OF 33 KV OUTDOOR PT |
| 127 | Laying of Control cable of all sizes through trench, proper connection at both ends outside in switchyard equipments & inside control room in VCB, control & relay Panels with proper marking, lugs, labelling & ferrules etc |
| 128 | EXCAVATION IN SOIL IN HILLY AREA/RIVER BED BY MECHANICAL MEANS I.E. BACKHOE LOADER (ITEM A) |
| 129 | EXCAVATION IN SOIL IN HILLY AREA/RIVER BED BY MECHANICAL MEANS I.E. BACKHOE LOADER (ITEM B) |
| 130 | PAINTING OF FUSE SET STRUCTURE |
| 131 | ERECTION OF T&P ITEMS |
| 132 | Fabrication of MS Channel angle iron etc in required sizes with drilling of holes upto good finish for top channel, bracing and special type bracket etc. as per RESPO schedule and local approved drawing. |
| 133 | ERECTION OF TERMINAL GANTRY |
| 134 | MAKING CABLE TRENCH |
| 135 | Painting of T.G. with one coat of Red oxide paint & 2 coats of Aluminum paints of best quality I.S.I. mark. |
| 136 | Installation of 33 KV CT with all connections |
| 137 | COMPLETE WIRING OF BREAKER BY PROVIDING FERULE ETC |
| 138 | PAINTING OF ISOLATOR/LA/CT/STRUCTURE COMPLETE |
| 139 | FIXING OF 33 KV LIGHTNING ARRESTOR |
| 140 | ERECTION OF LINE ISOLATOR STRUCTURE WITH INST. |
| 141 | LAYING, SPREADING AND STRINGING BUS BAR CONDUCTOR BY ACSR PATH CONDUCTOR WITH MAKING ALL CONNECTIONS |
| 142 | Erection charges of structure |
| 143 | EARTHING OF STRUCTURE USING GI STRIP |
| 144 | ERECTION OF 33KV CONTROL PANEL (FEEDER/T/F) |
| 145 | Installation / Fixing of 33 Kv Isolator on structure at 33 Kv switchyard with proper alignment & Connections with busbar complete. |
| 146 | ERECTION OF 33 KV VCB |
| 147 | Laying of Control cable of all sizes through trench, proper connection at both ends outside in switchyard equipments & inside control room in VCB, control & relay Panels with proper marking, lugs, labelling & ferrules etc |
| 148 | Miscellaneous Charges for civil work |
| 149 | Annexure-B (SUPPLY ITEMS) (As per UPCL Norms) |
| 150 | MEGGAR 5 KV DIGITAL |
| 151 | 2.5 KV MEGGAR DIGITAL |
| 152 | MAXIMUM & MINIMUM DISPLAY BOARD |
| 153 | STEEL ALMIRAH |
| 154 | FIRE EXTINGUISHER ABC TYPE 5KG |
| 155 | PORTABLE FOAM TYPE FIRE EXTINGUISHER 5LT |
| 156 | 11 KV H/S JOINTING KIT 185 SQ MM (O/D) |
| 157 | WIRE MESH FENCING |
| 158 | OFFICE TABLE SIZE (4X2.5) |
| 159 | SUB STATION NAMED BOARD |
| 160 | EARTH MEGGAR DIGITAL |
| 161 | STEEL OFFICE CHAIR GODREJ |
| 162 | SINGLE LINE DIAGRAM BOARD |
| 163 | 90 WATT LED LIGHT WITH ACC. |
| 164 | G.I STRIP 35X5MM |
| 165 | STEEL OFFICE TABLE |
| 166 | EARTH CHAIN |
| 167 | D-SPANNER SET |
| 168 | NAME PLATE OF EQUIP. TG,LI,BI,CT,CB ECT. |
| 169 | CEILING FAN |
| 170 | FLEXIBLE COOPER CONNECTOR 50X50MM |
| 171 | INSTRUCTION BOARD |
| 172 | 11 KV H/S JOINTING KIT 185 SQ MM (I/D) |
| 173 | PG CLAMP FOR DOG CONDUCTOR |
| 174 | STAY CLAMP FOR SP-33 WITH NUT & BOLT |
| 175 | INSULATED ELECTRICAL PLIER TAPARIA |
| 176 | BOLT AND NUT 180X16 MM |
| 177 | 33/0.433 KV, 63 KVA STATION TRANSFORMER |
| 178 | 3X70 SQ MM XLPE 33 KV CABLE-D |
| 179 | ST. LIGHT MANAG. TIMER SWITCH WITH METER |
| 180 | DB I/C MCB 30A-1 NO. & OG MCB 10A-10NOS. |
| 181 | DCDB 24V |
| 182 | STEEL CABINET |
| 183 | MS BAR 10MM |
| 184 | SUNDRIES ITEM LUG GLAND ETC |
| 185 | GI PIPE 4\\" DIA |
| 186 | PIPE WRENCH 12'' |
| 187 | TOP CHANNEL CLAMP FOR SP-33 WITH N&B |
| 188 | GI PIPE 4\\" DIA (ITEM 2) |
| 189 | MS PLATE 225X225X8MM |
| 190 | MS PLATE 225X225X8MM (ITEM 2) |
| 191 | MS PLATE 225X225X8MM (ITEM 3) |
| 192 | PERFORATED TRAY 400MM FOR CABLE TRENCH |
| 193 | M.S.PLATE 400X400X8 MM |
| 194 | STONE PAD 300X300X75MM |
| 195 | STONE PAD 300X300X75MM (ITEM 2) |
| 196 | STONE PAD 300X300X75MM (ITEM 3) |
| 197 | WALL CLOCK |
| 198 | LED TORCH WITH ELECTRIC CHARGING |
| 199 | STONE PAD 300X300X75MM (ITEM 4) |
| 200 | MS BAR 12MM DIA FOR STEEL REINFORCEMENT |
| 201 | SAFETY CHART |
| 202 | 24 V BATTERY SET |
| 203 | 33 KV HAND GLOVES |
| 204 | DOOR MAT |
| 205 | DUSTBIN PLASTIC SIZE (SMALL) |
| 206 | FIRST AID BOX |
| 207 | R.S. JOIST 175X85MM |
| 208 | MS ANGLE 40X40X5 MM |
| 209 | MS ANGLE 40X40X5 MM (ITEM 2) |
| 210 | RAIL 90 LBS |
| 211 | RUBBER MAT (INSULATED) 1MX1MX3MM |
| 212 | FIRE BUCKET STAND WITH BUCKETS |
| 213 | GI STRIP 50X6 MM |
| 214 | G.I EARTH STRIP 65X6MM |
| 215 | WALL FAN |
| 216 | M.S.PLATE 400X400X8 MM |
| 217 | CONNECTORS FOR FUSE SUITABLE FOR PANTHER |
| 218 | PG CLAMP ACSR PANTHER TO ACSR DOG |
| 219 | NAME PLATE OF FEEDER |
| 220 | 11KV DANGER BOARD WITH CLAMP |
| 221 | DANGER BOARD |
| 222 | SHUT DOWN/ BREAK DOWN BOARD |
| 223 | PERFORATED TRAY 200MM FOR CABLE TRENCH |
| 224 | PERFORATED TRAY 100MM FOR CABLE TRENCH |
| 225 | NAME PLATE OF STATION T/F |
| 226 | ALUMINIUM LUG |
| 227 | 33 KV DANGER BOARD WITH CLAMP |
| 228 | BRACING CLAMP FOR ST POLE WITH N&B |
| 229 | TOP CHANNEL CLAMP FOR SP-33 WITH N&B |
| 230 | BOLT & NUTS OFF SIZE (ITEM 1) |
| 231 | BOLT & NUTS OFF SIZE (ITEM 2) |
| 232 | BOLT & NUTS OFF SIZE (ITEM 3) |
| 233 | BOLT & NUTS OFF SIZE (ITEM 4) |
| 234 | BOLT & NUTS OFF SIZE (ITEM 5) |
| 235 | BOLT & NUTS OFF SIZE (ITEM 6) |
| 236 | BOLT & NUTS OFF SIZE (ITEM 7) |
| 237 | BOLT & NUTS OFF SIZE (ITEM 8) |
| 238 | BOLT & NUTS OFF SIZE (ITEM 9) |
| 239 | BOLT & NUTS OFF SIZE (ITEM 10) |
| 240 | T CONNECTOR |
| 241 | PG CLAMP ALU ALLOY PANTHER TO PANTHER |
| 242 | 24V BATTERY CHARGER |
| 243 | CONNECTOR SUITABLE PANTHER FOR VCB |
| 244 | 11 KV FUSE SET |
| 245 | 11KV 3P(400A) 3PIN VERT. MOUNT GO AB TPMO |
| 246 | PG CLAMP ALU ALLOY PANTHER TO DOG |
| 247 | CONNECTOR OF POWER T/F LV SIDE |
| 248 | PG CLAMP FOR PANTHER TO PANTHER |
| 249 | STONE PAD 300X300X75MM |
| 250 | 33KV ISOLATOR CONN. CLAMP FOR PANTHER, N&B |
| 251 | CONNECTOR SUITABLE FOR PANTHER FOR LA |
| 252 | CONNECTOR SUIT FOR CT/PT FOR PANTHER/DOG |
| 253 | MS PLATE 400X400X8MM |
| 254 | CONNECTOR SUITABLE PANTHER FOR VCB |
| 255 | MS PLATE 225X225X8MM |
| 256 | MS NUT & BOLT OFF SIZE |
| 257 | T CONNECTOR |
| 258 | GI STRIP 50X6 MM Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender