Educational and Research Institute Government Departments Closing in 33 days TDR #56597173

Tender For Shifting Of Signalling And Telecom Infringed Cable In Connection With Badlapur-Karjat 3Rd & 4Th Line Under Mumbai Urban Transport Project-3B (Mutp-3B)

Issued by Government Departments · Thane, Maharashtra
Tender Value
17.63 Crore
Estimated cost
Bid Submission
25 Aug 2026
33 days left
EMD
41.60 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thane → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Shifting Of Signalling And Telecom Infringed Cable In Connection With Badlapur-Karjat 3Rd & 4Th Line Under Mumbai Urban Transport Project-3B (Mutp-3B)

BOQ

Name of Work:- Shifting of Signalling and Telecom Infringed Cable in connection with Badlapur-Karjat 3rd & 4th line under Mumbai Urban Transport project-3B (MUTP-3B)
Sl. No. Item Description
1Item Wise BoQ BoQ_Ver3.0 Item Wise Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: MUMBAI RAILWAY VIKAS CORPORATION LIMITED Name of Work: Shifting of Signalling and Telecom Infringed Cable in connection with Badlapur-Karjat 3rd & 4th line under Mumbai Urban Transport project-3B (MUTP-3B) Contract No: RFT No:- MRVC/W/BUD_KJT/403 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns. Bidder's Name shall be enter at cell No. B8 shaded in Green , else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Schedules of Bill of Quantities Item Code / Make Quantity Units Estimated RateinRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE QUOTED BY THE BIDDER RATE QUOTED BY THE BIDDER Offer Cost (In Rs)Excluding GST Schedule B ScheduleC Schedule D Schedule E Schedule F Schedule D Part I Schedule D Part II Schedule D Part III Offer Cost (In Figures)Excluding GST TOTAL AMOUNT With Taxes Offer Cost (In Words)Excluding GST
2Complete Tender Schedules(Schedule A ,B,C,D & E) Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only
3Schedule A: Supply (SOR)
4Outdoor Works
51. Relays.
6Supply of QNA1 AC immunised neutral relay, 8F-8B, 24 VDC along with plug board, retaining clip and connectors confirming to BRS : 930, IRS:S60, IRS:S34 & IRS:S23. Inspection by RDSO.
72. Signals-Units, Structures & Fixtures.
8Supply of Main signal post 140 mm outer dia 3.6 Mtr Length as per spec No.IRS S 6/81 with latest amendments. Inspection by Consignee.
9Supply of Main Signal Post 140 mm outer diameter 4.6 Meter Length as per spec No IRS S 6/81 with latest amendments. Post shall be supplied duly deep galvanized. Inspection by Consignee
10Supply of Main Signal Post 140 mm outer diameter 5.6 Meter Length as per spec No IRS S 6/81 with latest amendments. Post shall be supplied duly deep galvanized. Inspection by Consignee
11Supply of Shunt signal post with Base (GI Pipe of 80 mm Dia of min. 1 meter length.) Inspection by Consignee
12Supply of Cast Iron Main signal surface base 140mm as per spec No IRS: S-10 and Drg No 2011/M with latest amendments, with CLS Ladder assembly complete for CLS signal 5.5/4.5/3.5 mtrs long as per RDSO Drg no. SA 23156 (Adv), SA 23153 (Adv) & SA 23150 (Adv) Alt.1 respectively with Latest Amendment as the case may be for CLS unit & signal back staging as per extent C.Rly practice. Inspection by RITES
13Supply of Cast Iron Shunt signal surface base 80 mm as per spec No IRS: S-10 and Drg No 2011/M with latest amendments, as per RDSO Drg. No.SA- 23156/ Drg. No.RST/11413 as per extant C. Rly practice. Inspection by RITES
14Supply of Signal No.Plates as per Drg No RST-11393/ SK-842. Inspection by Consignee.
15OFF set bracket 5-1/2\\" to suit 140 mm dia CLS Post with two no. of \\"U\\" Bolts with nut & washer complete as per RDSO Drg No SA-23080 for signals & Routes. Inspection by Consignee.
16OFF set bracket 3-1/2' for signals & Routes. Drawing No.SA23840(Adv) Alt-2 as per extent C.Rly practice. Inspection by Consignee.
17Supply of A/AG/C/G Board as per Drg. RST-11444/1(A), RDSO Drg No SA-23460(AG), SA-23461(C) & SA 23477(G) as applicable respectively with Latest Amendment. Inspection by Consignee.
18Supply of \\"2 aspect\\" Signal Unit in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps and suitable for 140 mm dia post saves pigment finish on the back side of the and inside. white pigment finish inside the 2 aspect unit to avoid any extra paint cost. Inspection by RITES.
19Supply of \\"3 aspect\\" Signal Unit in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps and suitable for 140 mm dia post saves pigment finish on the back side of the and inside. white pigment finish inside the 4 aspect unit to avoide any extra paint cost. Inspection by RITES.
20Supply of \\"4 aspect\\" Signal Unit in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps and suitable for 140 mm dia post saves pigment finish on the back side of the and inside. white pigment finish inside the 4 aspect unit to avoid any extra paint cost. Inspection by RITES.
21Supply of Shunt Signal Position Light Type FRP complete as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest with Off set bracket 3-1/2\\" to be fitted on 140 mm post drawing No.SA23840(Adv) Alt-2 for dependent type complete with signal unit bracket, terminals etc without lenses, lamp, lamp holder, and to suit LED signal lamps. Inspection by RITES.
22Supply of 1 way junction Route Indicator in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev. 2.0 or latest complete and to suit LED signal Lamps. Inspection by RITES.
23Supply of 2 way junction Route Indicator in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev. 2.0 or latest complete and to suit LED signal Lamps. Inspection by RITES.
24Supply of \\"Calling On\\" Signal Unit in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev. 2.0 or latest complete and to suit LED signal Lamps. Inspection by RITES.
25Supply and Fixing of RE Protective Screens of expanded metal 12 SWG of size 1200 x 1500 mm on signals as per extent practice & as per instruction of Rly engineer at site DRG - No.SK-844. Inspection by Consignee.
26Supply of Main LED Signal lighting unit working on 110V AC as per RDSO Specification No. RDSO/SPN / 199/ 2010 Rev.1.1 with latest amendment for Red Aspect. Inspection by RDSO.
27Supply of Main LED Signal lighting unit working on 110V AC as per RDSO Specification No. RDSO/SPN/199/2010 Rev.1.1 with latest amendment for GREEN Aspect. Inspection by RDSO.
28Supply of Main LED signal lighting unit working on 110V AC as per RDSO Specification No. RDSO/SPN/199/2010 Rev.1.1 with latest amendment for Yellow Aspect. Inspection by RDSO.
29Supply of Main LED Signal lighting unit 110V AC for Calling ON signal as per RDSO Specification No. RDSO/SPN/153/2011 (Rev. 4.1) with latest amendment. Inspection by RDSO.
30Supply of Main LED Signal lighting-unit 110V AC for Route Signal as per RDSO Specification No. RDSO/SPN/153/2011 (Rev. 4.1) with latest amendment. Inspection by RDSO.
31Supply of Main LED Signal lighting unit 110V AC for Shunt Signal as per RDSO Specification No. RDSO/SPN/153/2011 (Rev. 4.1) with latest amendment.. Inspection by RDSO.
32Apparatus Case
33Location box made of Special Grade SS 304 of size as per Drawing No. DRM/SG/945 dated 03.03.2011 (Half Apparatus Case) with latest amendment. Manufacturer's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply. Inspection by Consignee.
34Location box made of Special Grade SS 304 of size as per Drawing No. DRM/SG/948 dt. 26.04.2011 (Single Apparatus Case) or latest. Manufacturer's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply. Inspection by Consignee.
35Supply of Phenolic 10mm thick sheet, grade P3 in standard size of 1.22X1.22 Mtr as per spec. No IS 2036 of 1995. OEM Certificate shall be supplied stating that Phenolic sheet is of 10mm thickness along with P3 Grade. Inspection by Consignee.
36Supply of ARA Terminal blocks with links made of PBT as per RDSO Specification No. IRS/75/2006(Rev-2) with latest amendments and RDSO Drg.Nos.SA-23741A Alt.4, SA-23745 Alt.5, SA-23746, SA-23748 Alt.4 & SA-23756A Alt.3. Inspection by RDSO.
37Supply of Tik-tak, piano type switches,5 A (as per IS Specification).Inspection by Consignee.
38Supply of three pole plug and socket 5 Amp (as per IS Specification).Inspection by Consignee.
39Supply of LED Lamp 110V/7W, 2 Pin for Location lighting.Inspection by Consignee.
40Earthing Equipments
41Supply of earth electrode assembly as per Drg.No.CR/S&T/SK-815. Inspection by Consignee.
42AFTC ITEMS
43Supply of bond plates suitable for terminating track lead connections of AFTC on rail. It consists of tapered stainless steel bolts, nuts, check nuts, washers, L shaped plate etc. as per drg. No.RST 11630. Each set of bond plates should consist of (i) SS taper pins - 8 nos (ii) SS M6 nuts - 20 nos. (iii) SS M6 plane washers - 32 nos. (iv) Spring washer - 8 nos. (v) Nylon nuts - 8 nos. (vi) S.S.hex bolts M6 x 15 - 2 nos. (vii) Track circuit cable plates - 4 nos. Supply of all above items would constitute one set. Inspection by Consignee.
44Supply of 2.5 mm SS rail clamp for AFTC \\"S\\" and \\"Alpha\\" bonds suitable for 60/52 kg rails sections as per Rlys. Latest drg. Fitted with rubber stopper as per Rly drg no.RST - 11945. Inspection by Consignee.
45Supply of SS Tapper in size 16 mm dia, 60 mm length, taper from 19mm to 16 mm along with hex nut, one check nut, one plain washer and one spring washer. As per drg no.SK-844. Inspection by Consignee.
46MSDAC
47Supply of Multi Section Digital Axle Counter (MSDAC) complete system including Central Evaluator and final track clearance relay for each section, Complete Reset boxes, Station Master Room cards, Station Master Key, Line Verification boxes, All track side units (Standard Counting Head) with detection point complete assembly & fixing arrangement for each detection point, Clamps Deflector for either side of each detection points, monitoring console for monitoring all the DPs at a time installed at a station with all other accessories fully wired and fully equipped as per RDSO specification No. RDSO/ SPN/176/2013 (Version 3) with latest amendment and manufacturers specification. The equipment must also include the following: 10% spare slots for both detection heads and track section in the evaluator for future and emergency provision This also includes supply of 10% Spares i.e., DP Cards, Modules and Sensors as per details mentioned in scope of work (fraction to be rounded off to next higher whole number). The commissioning of the equipment shall be done under the supervision of the manufacturer.Supply of documents by Contractor shall be as per Para No.18.0 of RDSO Specification No. RDSO/ SPN/176/2013 (Version 3) with latest amendment. The warranty of the equipment shall be in accordance with IRS Specification No. S- 23. Diagnostic Terminal (PC) shall be provided at all stations as mentioned in the Scope of work.MSDAC shall be supplied as per details mentioned in Scope of Work. Inspection by RDSO.
48Point Machne & Fixures
49Supply of Electric Point Machine IRS type 143mm stroke complete with Lock, Detector and slides for lock and detector, non- trailable to operate on 110V DC, Rotary locking, Universal type as per specification Nos. IRS: S- 24/2002(Amd.1) (IRS S.37/82 Revision: 1 With Amendments 1, 2, 3 & 4 and Drawing No. RDSO S-10800Alt.5, with common key for all point machines. (IRS: S-37/2020- Version 2.0 with latest amendment. Also feature of IP-67 protection and AC immunity of 400 V.) Telescopic pipe and a tool kit. Inspection by RITES.
50Supply of Electric Point Machine, Non Trailable, Internal Locking, 220Mm Throw With IP 67 Motor, Minimum AC Immunity 400Vac With Tools And Complete Accessories Including Complete Ground Connection And All Insulation, Crank Handle And Along With Clamp Point Lock 60Kg, TWS As Per Drawing No. RDSO/S/11000 as per RDSO Specification lRS:S- 24/2002 With Amd.01 with latest amendment. IRS Type. Inspection by RITES.
51Supply of William stretcher nylon insulation Set suitable for ground connection as per RDSO Drawing No T-10367, T-10368, T-10384 as applicable and to the spec IRS S 23 & 40/84 with latest amendments. Inspection by Consignee.
52Supply of Tongue attachment nylon insulation Set consisting of one insulating plate as per Drawing No. RST-106961 & 3 Nos of Ferrules with collars to suite rodding supplied as per RDSO Specification & Drawing No. RST-10692 with latest amendment. Inspection by Consignee.
53Supply Gauge Tie plate nylon insulation as per RDSO DRG No: T- 10372 Alt2, T- 10368, T- 10371 Alt2, T-15083/88/Alt2 & T-11690/Alt2 and to the spec IRS S 23 & 40 with amendment 01 with latest amendment.. Inspection by Consignee.
54Supply of Ground connections, complete set suitable for IRS type point Machine for ordinary turnout with tongue attachment insulation and other insulation as per RDSO Drawing No. S/3361/62/63 (for IRS type point machine) or RDSO Drawing No. SA-9151/52 (for Siemens point machine) with latest amendments. However, the ground connection shall be procured only after confirmation from MRVC Engineer. Inspection by Consignee.
55Supply of Ground connections, complete Set suitable for IRS type point Machine for derailing switch with tongue attachment insulation as per RDSO Drawing No S/3361/62/63(for IRS type point machine) or RDSO Drawing No. SA 9151/52 with latest amendments. However, the ground connection shall be procured only after confirmation from MRVC Engineer. Inspection by Consignee.
56Supply of GI bend pipe, 'B' class, 50mm diameter for cable entry in point machines, along with required fixing arrangements as per standard practice on Central Railway. Drawing No. RST.11835 with latest amendment. Inspection by Consignee.
57Supply of Point Machine Raised Bracket FRP make with cover as per Drawing No.SK-846 with latest amendment. Inspection by Consignee.
58Cable Laying
59Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239 PT. 1/2004 or latest with sockets and fittings. TATA/JINDAL/ZENITH BIRLA make. Inspection by Consignee.
60Supply of DWC HDPE pipe with one snap fit coupler and 'O' ring fire resistant, anti rodent, in 6 meter length of size 120 mm outer dia as per RDSO/SPN/204/2011 Ver 1.1 with Amd.1 or latest. Inspection by RITES.
61Supply of RCC pipes 150mm dia alongwith collars as per IS No.458/2003 amendment-1 with Rev.4. Inspection by Consignee.
62Supply of RCC pipes half round of size 150mm dia outer and 100 mm dia internal 1 mtr long matching to IS No.458/2003 amendment-1 with Rev.4. Inspection by Consignee.
63Supply of RCC pipes half round of size 300 mm dia outer and 250 mm dia internal 1 mtr long matching to IS No.458/2003 amendment-1 with Rev.4.
64SUPPLY OF \\"C\\" CHANNEL CLAMPS with nut bolts, washers and all type fixures for 6 inch dia pipe to be fixed on GIRDERS, on rock cuttings etc. as per DRG No.-SK-900. Inspection by Consignee.
65Supply of Adhesive Tapes rolls, PVC (18mm x 25 Mtr) Steel Grip/SCOTCH/ANCHOR. Inspection by Consignee.
66Supply of Thermo-Shrink cable joining kit (Reinforced) TSF-2 type generally confirming to RDSO specification RDSO/SPN/TC/57/2015 Rev 1 with modified kit contents as per CSTE's Specification No.:CR/SPN/TC/57 (A)/2015 Dt: 06.01.2015 (Table-A) to be suitable for jointing both 10/20/50 pair PIJF and 4/6 Quad cables alongwith sub-kit (Table-B) for armour continuity. Inspection by Consignee.
67Supply of cable route marker as per RST/C/203A of FRP. Inspection by Consignee.
68Electrical Lifting Barrier Related Items.
69Supply of Electrically operated LIFTING BARRIER complete set without Hand Generator, Operating on 110V AC, with Boom length 9.76M along with one spare boom confirming to RDSO/SPN/208/2012 Ver.2.0 with amendment 1 or latest amendment. Inspection by RITES.
70Supply of Sliding Boom complete as per Central Railway practice Drg. No-SK-860 (1-3/3). Inspection by Consignee.
71Electronic LC gate telephone system as per Specification RDSO/SPN/TC-51/2021 Revision -1.0 ( With Voice logging facility). Inspection by Consignee.
72Master Telephone
73Slave Telephone
74Supply of Electronic Solid state flasher Unit for Road traffic signal 24 DC. ACES/Muconny make with operating voltage 110V AC. Inspection by Consignee.
75Supply of Dual Tone warning Bell with 20W horn and 15W Amplifier ACES/Muconny make with operating voltage 110V AC.
76Supply of LED type boom light suitable for 110V AC color Red flashing body enclosure MS, CRC with mesh. Inspection by Consignee.
77Supply of signal unit including post & unit (2aspect) without LED Lamps to provide indication to the road user. The signal unit shall be of FRP type. RDSO/SPN/194/2006/Rev. 2.0 The complete arrangement shall be got approved by engineer charge before supply and erection. Inspection by Consignee.
78Miscellaneous Items.
79As and when required by the Engineer in charge arranging /providing of unskilled manpower for various safety related works such as protection of track etc. with contractor's T&P, equipment, hand signal flags, spanners, hammers, etc. as per as per details mentioned in scope of work. Inspection by Consignee.
80Skilled manpower to be provided by contractor for monitoring JCB working. The manpower shall provide marking & supervisory work for the protection of S&T cables during digging work by JCB's and repairing /restoring/jointing of cables, if damaged Jointing Kit shall be provided by MRVC. Manpower shall mark the location with white chuna. White Chuna shall be provided by contractor. Information for deputing Skilled Manpower will be provided by MRVC Engineer in charge 24 hours in advance from commencement of digging work by JCBs. They will check cables route by Cable route tracer and will do chuna marking and will show the cables (on rough sketch) available in a small length approximate 50-100 meters of digging. Note: Minimum two man will be provided at a time including Cable jointer, they will stay whole time during JCB digging work. (The CV to be got approved by MRVC). Inspection by Consignee.
81Hiring of JCB Machine (in good working condition) for levelling and dressing ground/dismantling structures including disposal of debris through dumpers etc. with contractor's labour, JCB machine, machine operator, fuel, etc. The contractor shall arrange road permit for vehicle for all the states of operation, as per instructions of engineer in charge and vehicle shall not be more than three years old. Inspection by Consignee.
82Provision of temporary Goomty of 3X3X2.5 Mtr on hire for NI working made up of waterproof tent with provision of one table, one chair and two incandescent lamps. (Electrical connection will be provided by MRVC). Inspection by Consignee.
83Transportation of Signalling material/equipments including loading and unloading in 10MT vehicle, anywhere to anywhere, and stacking at destination as per instructions of SSE in-charge as per inventory. For carrying heavy materials like cable drums, DG set, Electrical Lifting barrier pedestal, IPS, Batteries, Point machine etc. This transportation item is for carrying materials as per specific / emergency requirement as per instruction of SSE S MRVC. Transportation material from Store Depot to Station/Specific site and from Station to Station in Kalyan – Badlapur section is not covered under this Item. Inspection by Consignee.
84Supply & Fixing of Stop Board, Block section limit Board, goods warning board and all other boards with contractors own material. The work shall be done as per instruction of Engineer in charge. Inspection by Consignee.
85Schedule B: Supply (Non SOR Items)
86Signal Units & Fixures
87A' marker LED Signal lighting unit, 110 V AC, retrofittable in existing CLS housing as per RDSO specification No.RDSO/SPN/153/2011 (REV.4.1). Inspection by RDSO.
88Point Machne & Fixures
89Supply of wire tree for use in point machine as per drg-RST- 11435, wiring tree lugs are to be crimped and soldered. Inspection by Consignee.
90Out Door Cables & Cable Joints
91PVC Insulated Armoured Unscreened Copper Conductor Underground Railway Signalling Cable Size 12 Core x 1.5 Sq.mm. confirming to RDSO Specfication No.IRS:S-63/2014 ( 4.0) or Latest Amendement. Inspection by RDSO.
926 Quad 0.9 mm dia jelly field under ground cable as per RDSO specification IRS-TC-30/2005 [Ver-1] Amendment No 4 or latest. Inspection by RDSO.
93Supply of Straight through Thermo Shrink joining kit suitable for signaliing cable 6/12 core 1.5 sq mm. copper conductors. Inspection by consignee.
94Electrical Lifting Barrier Related Items.
95Supply of High Intensity grade Retro-Reflective luminous strip of Black colour of size 305mm wide of Kiwalite make or similar. Inspection by Consignee.
96Supply of High Intensity grade Retro-Reflective luminous strip of Red colour of size 305mm wide of Kiwalite make or similar. Inspection by Consignee.
97Supply of High Intensity grade Retro-Reflective luminous strip of Yellow colour of size 305mm wide of Kiwalite make or similar. Inspection by Consignee.
98Supply of Limit Switch new top rollar with 2 NO + 2 NC Contacts for HEIDZ make electrically operated lifting barrier as per IERS-S41/70 amendment 2. Inspection by Consignee.
99Miscellaneous Items.
100Deployment of Technicians (Signal &Telecommunication) for Supervision of Kalyan-Badlapur Project. The eligibility criteria of technical and supervisory staff are mentioned in the Scope of Work. Inspection by Consignee.
101Hiring of Two (four wheeler) AC vehicle XYLO/TAVERA/BOLERO/TATA SUMO or similar type for use of MRVC officials. The details of requirement and operation of vechicles is mentioned in scope of work. Inspection by Consignee.
102Schedule C: Execution (SOR Items)
103Signal Units & Fixures
104Excavation and Casting of Main signal foundation as per Drg No SK 801 with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. One sample of foundation is to be got approved from Engineer In-charge before execution. Inspection by Consignee.
105Excavation and Casting of Shunt signal foundation as per Drg No SK 802 with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. One sample of foundation is to be got approved from Engineer In-charge before execution.Inspection by Consignee.
106Erection of CLS Post with Surface base and signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards, signal name plates/boards if any with contractors own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work also includes fixing of number plates, A/P/C Board. The work shall be done as per instructions of MRVC Engineer at site.Inspection by Consignee.
107Erection of shunt signal with Surface Base, Post, Signal unit and fixing of Number plates. The work shall be done as per instructions of MRVC Engineer at site. Inspection by Consignee.
108Fixing of Jn.Route Indication 1-Way/2-Way/3-Way/4-Way /5 Way on the top of the signal post.
109Termination of Tail Cable and Installation of LED Signals:Installation of LED (Main/Shunt/Route/ Calling On) in signal unit. It includes termination of Tail Cable including spares, if any, complete wiring, fixing of LED units and testing. Installation and commissioning of any one aspect of Main/Shunt/Route/Calling On signal shall constitute execution of one No. of LED. The work shall be done as per instruction of MRVC Engineer at site. Inspection by Consignee.
110Supply and fixing of Protective screen of expanded metal 12 SWG of size 1200 x 1500 mm on signals as per standard practice. Protective Screen shall be deep galvanized and Certificate of OEM shall be supplied certifying deep galvanisation in Protective Screen. Inspection by Consignee.
111Point Machne & Fixures
112Refixing of electrical point machine, ground connection during phase working (Non interlocked working) after removing the existing fitting if any, adjustment if necessary, cable termination, wiring, testing and commissioning of electrically operated point, fixing and connecting point indicator on derail switch if necessary. The work shall be done as per extant practice on C. Rly & the instruction of Site In Charge at site. This item is applicable for refixing of Electrical Point Machine in the Turn outs during NI period. Inspection by Consignee.
113Fixing of point machine on newly laid turnout on Wooden/MBC sleepers , fixing of ground connections, adjustment and testing with crank handle operations, Removal of ground connection & point machines duly numbered. This will include fixing of bend pipes with welded frame for cable entry to machine. This will also includes necessary adjustment and smithy work, drilling of holes to tongue rails, fitting of insulation for tongue attachment, gauge plate & stretcher bars, cable termination & wiring if required. The work shall be done as per extant practice on C. Rly & the instruction of MRVC Engineer at site. This item is applicable for fixing of Electrical Point Machine in the Assembled Turn outs during Non/Pre NI period. Inspection by Consignee.
114Termination of Tail cable inside the point machine through bend pipe this includes preparatory work of pulling the cables, and peeling out the insulation, dressing and lacing after termination etc., pulling of tail cable as per circuit requirement inside point machine through bend pipe, termination of cables on terminal blocks as per instruction of site supervisor the cable shall be entered in such a way that, armouring shall protect the cable near sharp edge of entry point and armouring shall be clamped between pipe fixing bracket and boy of point machine. Inspection by Consignee.
115MSDAC
116Installation, wiring, testing and commissioning of Central Evaluator, Power Supply equipment for Axle counters including its associated all indoor equipment’s, indication Panel, monitoring console/ interface computer and wiring the same to integrate with the relay circuits. This also includes wiring from the CT rack to the Central Evaluator, installation and wiring the reset box, LV box, and wiring the power supply to the Central Evaluator including the supply of 2 core shielded cable of required conductor size as per IRS S 76/89 or IS 694/1977 applicable with other accessories & 16 sq.mm PVC (approximately 50M) from IPS room to Central Evaluator. This also includes Supply, laying, and termination of cable if any from Panel room to Axle counter room /Relay room in DWC pipe with Contractor’s own material including Cable ladder, wiring work on evaluator. All wires, power equipment accessories, cable ladder, truff, DWC Pipes, various galvanized nut bolts, coloured ferrules, earthing arrangements up to Busbars, Lugs, Wires, PVC pipe, PVC bends etc. are to be supplied by Contractor. The work has to be executed as per RDSO’s TAN- STS/E/TAN/7010 version 1.0 or latest issued from RDSO/OEM's manual. Inspection by Consignee.
117Installation of complete assembly of track device/double rail contact unit for entry or exist with conductors all material including drilling of required sizes holes on rails for fixing these, taking the cable lead through anti-rodent, anti-oxidant & non-flame propagating type Double walled corrugated (DWC) pipe as per RDSO/SPN/204/2011 Ver.1.1 with Amd.1 or latest from track device to location box and terminating it on terminals including digging of trench under track and upto location/Track side unit and all other accessories as per site requirement for laying of transmitter and receiver cable with suitable wire embedded rubber pipe with clamp for protecting these cables at DP end. Entire required work excluding deflector plates of wiring/fixing on field site is included. The work must be executed as per TAN No. TAN- STS/E/TAN/7010 version 1.0 or latest issued from RDSO/OEM's manual. All requisite materials like Lug, Nut bolts, DWC pipe, Wires, PVC pipe, PVC bends etc. for complete installation shall be provided by Contractor. Inspection by Consignee.
118Installation of complete assembly of deflectors on either side of track device/double rail contact unit including drilling of required sizes holes on rails for fixing these. Inspection by Consignee.
119AFTCs ITEMS
120Supply and fixing of track lead connections of Siemens AFTC by providing duplicate (Doubled) copper cables from each rail to tuning unit and tuning unit to centre of S bond as per drg. No. RST 11930. In total six copper cables will required to be connected. All copper cable should be of 25 sq mm cross section made of multi stranded copper wire as per IS 694 of 1990 with latest amendment if any. All copper cables should be crimped with suitable size tinned copper lugs at both the ends. This also includes fixing of two bond plates in each of the rail by drilling holes of 7.2mm on web of rails as per standard practise of Rlys, terminating copper cables on one side of bond plate fixed on rail and on other sider of terminal inside the tuning unit. Copper cables are to be taken through HDPE pipe. Bond plates with pins and pipe would be supplied by Rlys. All other items should be arranged by contractor. Execution of complete work shall constitute on set. Inspection by Consignee.
121Supply & fixing of S bonds connections of siemens type AFTC by providing S bonds of suitable size as per drg. RST 11930. Bonds should be made of duplicate (doubled) PVC 4mm wall thickness coated wire rope of cross section approx.185 sq mm. PVC coated wire rope should be as per IS 2266 of 1978 and PVC sheating should be of compound type six as per IS 5831 of 1970 with latest amendments if any. Reclaimed or recycled materials should not be used. Brass lug should be brazed at both the ends of S bonds and brass terminal at in the centre of S bond as per sample and drg. S bond are to be fixed along the foot of rails in the form of \\"S\\" and both the ends of brass lugs are to be connected to rails by putting one rivet and one SS taper pin at both the ends. Length of S bonds is to be as per site requirement. Inspection by Consignee.
122Foundation and erection of AFTC junction box as per instruction of Rly site engineer. Inspection by Consignee.
123Drilling of holes of 16 mm dia as per instructions of Rly site in charge in rails using contractors own drilling equipments. Power supply for operating drilling equipments to be arranged by contractor. Inspection by Consignee.
124Apparatus Case
125Excavation and Casting of Apparatus Case foundation with contractors Anchor bolts, cement, ballast and other materials. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. Inspection by Consignee.
126Single Case as per Drawing No. SK-803 with latest amendment.
127Half Case as per Drawing No. SK-804 with latest amendment.
128Erection of Apparatus Cases. This includes filling of location foundations and plastering. Inspection by Consignee.
129Single Case
130Half Case
131Fabrication and fixing of phenolic laminated/Fibre glass sheet in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1&2. with latest alterations & as per instructions of MRVC engineer at site. Inspection by Consignee.
132Single Case
133Half Case
134Fixing of ARA Terminals and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. Inspection by Consignee.
135Termination of cable cores on ARA terminal/fuse blocks in the apparatus Cases/ cable termination rack. This includes all associated works of pulling out the cable from underground. The work shall be done as per location plans and instructions of MRVC Engineer at site. Inspection by Consignee.
136Installation of Eqpt. (Relays, resistance, chargers batteries etc.as applicable) & wiring of the same in apparatus Cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice. This includes fixing of Relay base or base of any other equipment as per Location Diagram/Circuit Diagram. Inspection by Consignee.
137Single Case
138Half Case
139Transferring of signalling/Telecom cables from existing location box to New location box. The work include breaking/dismantling of existing foundation of locations, excavating and removing /segregating coils of this cables which may be of about 10 mtr in length .These cables are then to be disconnected and removed from the existing locations one by one as per the instructions and under the supervision of railway staff present at site. The cable is then to be inserted and terminated in new location box. The item includes neatly dressing of cables marking wiring tree etc. The material required for dressing /lacing will be arranged by contractor at its own cost. The work is required to be done systematically and with due precaution during the night block of 2.00-2.30 hrs each or within the time that may be allowed. The excavation work to be done carefully without damaging the cables to avoid undue failures. (Termination charges will be given separately) Note: Proportionate payment will be made if cable is of other length. 2/6/12/19/24/30 core signalling cable/4 or 6 Quad/PIJF/Any Signalling/Telecom Cable(One no. unit= One cable of 10 m length). Inspection by Consignee.
140Patching work in old location box consisting 1) Digging of pit, cleaning of earth from all sides, breaking of seal of location boxes removal of sand from location, marking of new cable holes. 2) insertion cable from ground 3) making place for cable termination in old location, shifting ARA, fuse etc after removal and termination including fixing of ARA. 4) Termination of cable in old location. 5) Filling of sand and plastering to all sides upto 50 mm below ground level. Inspection by Consignee.
141Shifting of existing full location boxes coming in the alignment of doubling. The work includes losing & removal of soil around loction boxes by excavating soil around foundation, making of pit for shifting of location box horizontally opposite to railway track up to 0.5 to 1.0 mtr. This includes loosing of existing cable coils without any damage. The excavated soil shall be back filled after shifting of Location Boxes. Location box along with its foundation shall be shifted by push method with the help of jacks or by crane by contractors own expenditure under instructions of engineer in-charge at site. Any minor repairs in foundation due to patching shall also be carried out by contractor as per instruction of Engineer incharge. The work may affect train working hence the work shall be done as per margin only or during traffic block only. Inspection by Consignee.
142Shifting of existing Half location boxes coming in the alignment of doubling. The work includes losing & removal of soil around loction boxes by excavating soil around foundation, making of pit for shifting of location box horizontally opposite to railway track up to 0.5 to 1.0 mtr. This includes loosing of existing cable coils without any damage. The excavated soil shall be back filled after shifting of Location Boxes. Location box along with its foundation shall be shifted by push method with the help of jacks or by crane by contractors own expenditure under instructions of engineer in-charge at site. Any minor repairs in foundation due to patching shall also be carried out by contractor as per instruction of Engineer incharge. The work may affect train working hence the work shall be done as per margin only or during traffic block only. Inspection by Consignee.
143Location strenthening of full case with wire mesh and concrete mixture as per drawing of full location. Inspection by Consignee.
144Location strenthening of Half case with wire mesh and concrete mixture as per drawing of full location. Inspection by Consignee.
145Laying of RCC half round cement pipe of approximate size (150/300 mm dia X 2 Meter length) inside the trench after laying of cable. Pipes shall be placed as per directives of engineer. Inspection by Consignee.
146Providing Road Breaker/concrete breaker/boulder or rock breaker with compressor & Jack Hammer for Railway work such as cutting & dismantling of road concrete/Brick pucca structure (RCC/Steel section) including contractors fuel, driver and all other charges completed as directed by Engineer in charge. Inspection by Consignee.
147Making an entrance for new cable in old existing location, Casting concreting and curing of foundation and restoring it to old position by perfect masonary/concreting work. Contractor will ensure that cable entered in Location Box is properly protected.
148Out Door Cables and Cable Laying Items.
149Laying of Signalling / Telecom / Optical Fiber cables of various cores/pairs/quads in trenches/GI pipes/ DWC pipes/trunking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels on each cable of coloured plastic adhesive tapes or any other identifiable material to give the cable number at each G.P.(Cables will be meggered before and after its laying by contractor under supervision of MRVC Representative and he will submit the meggering report of each testing and recorded in meggering register). Length of the cable laid includes the length of the cable coiled for termination purposes. Inspection by Consignee.
150Removal of PSC/wooden sleepers coming in the way of/route of cable trenching, signal/location foundation/Track crossing etc. This obstruction will be removed by contractor for ensuring proper execution of related works. Inspection by Consignee.
151Removal of Redundant/old rails coming in the way of/route of cable trenching, signal/location foundation/Track crossing etc. These obstruction will be removed by contractor for ensuring proper execution of related works. Inspection by Consignee.
152Laying of GI pipes in on bridges/culverts/concrete drain/mountain ridges etc. with suitable GI bend shall be provided where there is turning of pipe as per the instruction of Site engineer. GI clamps at every 1-2m as shown in the drawing to be fixed. Suitable holes to be made in the pipe before laying as per the instruction of the site engineer. The GI Pipe of 100mm dia shall be supplied by MRVC. Drg. No. SK 808 or latest shall be applicable.
153Laying of DWC/RCC/GI pipes along with collars/RCC Half round pipes in trenches at places of track and road crossings, platform cuttings etc.Inspection by Consignee.
154Excavation of cable trench as per cable route plan,1.2 mt. deep and 500mm wide alongside the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness after clearing of route, bushes etc. In case depth is not achievable due to site condition, same shall be certified by MRVC Engineer. The work shall be done as per the extant practice on Central Railway and instructions of MRVC Engineer at site. Inspection by Consignee.
155Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide alongside the track in hard soil, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness after clearing of route, bushes etc. In case depth is not achievable due to site condition, same shall be certified by MRVC Engineer. The work shall be done as per the extant practice on Central Railway and instructions of MRVC Engineer at site. Inspection by Consignee.
156Cutting of all types of Roads/ platforms for trenching and excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI /DWC pipe & to restore them to original condition. The work shall be done as per extant practice on Central Railway & instructions of MRVC Engineer at site. Drawing No. SK 807 or latest. Inspection by Consignee.
157Fixing of GI pipes for crossing the culverts, bridges etc. and concreting of ends with brick masonry at both ends as per the instruction of MRVC Engineer at site. Inspection by Consignee.
158Placing and securing of cable route markers in trenches at the specified interval and at diversions, joints etc along the cable route. The work shall be done as per extant practice on C Railways & the instruction of MRVC Engineer at site. Inspection by Consignee.
159Jointing of 4 / 6 quad cable with Heat shrinkable straight through jointing kit for 4/6 quad cable.
160Making of thermoshrink straight through/derivation/transformer /PIJF cable joint for underground jelly filled cable 6 quad/4 quad/20 pair 10 pair etc. PIJF cable as per the instruction of Rly engineer at site.
161Wherever depth of 0.5M cable trench is not feasible, cable shall be protected as under: -Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench. Inspection by Consignee.
162Laying of GI pipes in on bridges/culverts/concrete drain/ mountain ridges etc. with suitable GI bend shall be provided where there is turning of pipe as per instructions of the site engineer. GI Clamps at every 2 m as shown in the drawing to be fixed. Suitable holes to be made in the pipe before laying as per instructions of the site engineer. 100 mm dia. Drg No SK 808. Inspection by Consignee.
163Laying of GI pipes inside the excavated trench in rocky area/less depth area as per instructions of the site engineer. GI Clamps at every 2 m as shown in the drawing to be fixed.Suitable GI Bend/Coupling and holes to be made in the pipebefore laying as per instructions of the site engineer.
164FIXING OF \\"C\\" Channel Clamps on Girders along with propercoupling of GI/DWC pipes. The work will be executed as perinstruction of site incharge and site incharge may take decision as per site condition. All the fixures, nut bolts, tolls required to fix the channel will be provided by Contractor. Proper safety equipment like Helmet, Retroreflective jacket and whistle, flag is to be made available during execution of work.
165WORK RELATED WITH ELEC. LIFTING BARRIER
166Installation, testing and commissioning of electrically operated lifting barrier, complete with Casting of cement concrete foundation for pedestal and boom rest post, cabling power supply connection & wiring with complete outdoor work. All the materials, tools required for commissioning of LC Gate will be arranged by the contractor. (As per Central Railway standard practice). Inspection by Consignee.
167Excavation and casting of foundation for sliding Boom with contractor own material including cement and another bolt of standard size. The required stop holding farma etc. for casting of foundation will have to be brought by the contractor at his own cost. The work shall be done as per instruction of Rly.Engineer at site. Inspection by Consignee.
168Erection of sliding boom assembly right hand, left hand with fixures. All the materials, tools required for erection of the sliding boom will be arranged by the contractor. (As per central Railway standard practice). Inspection by Consignee.
169Installation & commissioning of sliding boom with E-type lock and HKT, this include wiring of HKT, running of cables, necessary painting and transportation of material from store to site. All the materials required for commissioning of the sliding gate will be supplied by the contractor. Inspection by Consignee.
170Erection of road signal with all accessories including fixing of Road siren in Road signal unit as per instructions of site-in-charge. Inspection by Consignee.
171Painting / Lettering
172Painting two coats of enamel paint over one coat of Red Oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer and paints both of any reputed make are to be supplied by Contractor. The work shall be done as per instructions of Rly engineer at site and extant practice on C Rly on location boxes, signal posts, TLJB. This includes lettering / Numbering Termination of signals, TLJB & Block joints if any, apparatus cases, gate booms, etc, Description writing, legibly and neatly inside location boxes, relay hut, gate lodge etc. - for LC Gate. Inspection by Consignee.
173Releasing of track magnet from existing location and fixing of track magnets at new location as per Central Railway Drg No. RST 11545 with antitheft clamped as per Drg RST 11472/4 & Central Railway Drg No. BB/SK/C-23 (Note: Track magnets are to be covered with metal sheet temporarily till final testing and commissioning. These sheets are to be removed just before commissioning). Inspection by Consignee
174Earthing Equipments
175Installation of Earth Electrode including MS flat for clamp etc. and connection to signalling equipments, lever frames, apparatus cases, signal, relay rack, block instrument, etc. This item includes digging of pit in earth 3 M deep & fixing earth electrode pipe, casting of cement concrete enclosure & cover as per RDSO Letter No. RDSO-SIGEnB (GEN)/1/2020 dated 30.06.2025 with latest amendment. Soil treatment to be done as per std. practice. This item includes provision of MS Flat, Earth lead wires and Soldering of lead wires. The other end of the wire is to be connected to block equipment, power equipment, cable sheath, and signals etc. as per site requirements. 7 strand GI wire shall be used as earth lead wire. Earth electrode shall be supplied by MRVC. Inspection by Consignee.
176Installation of unit Earth as per RDSO Letter No. RDSO-SIGEnB (GEN)/1/2020 dated 30.06.2025 with latest amendment to construct earthing of
177Dismentalling
178Releasing of Outdoor Gears
179Dismantling / Releasing of existing Signalling Gears. One Signalling gear will be all parts of one signal (consisting of CLS unit, Signal post along with base and other accessories including AWS Magnet and Opto Couplers) or lever frame (5 levers set), or one point (consisting of all parts of a mechanical point, point machine, ground connections etc.) or one track circuits (consisting of battery box & other parts of DC Track circuit / AFTC /DAC) or one Block instruments or One Lifting Barrier or One Location Box etc.. This includes the cost of transportation of release materials to store depot or as decided by Engineer in charge. (Per unit means Per Gear). Inspection by Consignee.
180Releasing of Concrete Foundations
181Dismantling of Concrete foundation/ Demolishing RCC/CC/Stonework /Cutting Tar/ carpentering/ CC Flooring / Precast concrete slab/ Brick work including leading the debris inside Railway limit or outside Railway limit as directed by site in charge. This work to be done by contactors with his own vehicle and labour. It should be ensured that while dismantling concrete foundations any Signalling/Telecom released cable should either be cut and released or buried or both. Inspection by Consignee.
182Schedule D (Execution of Non SOR)
183Execution of S&T work related to engineering / signallling block of CTR/TTR/TSR of others, in one block, five unskilled manpower have to be provided during block of S&T connection removing & refixing as per Railway site engineer instructions.Inspection by Consignee.
184Schedule E ( Credit For Scrap Value)
185Credit for all types of Indoor / Outdoor Signalling cables as per the details mentioned in the Scope of work.
186Credit for all types of Indoor / Outdoor Signalling MS Scrap other than Signaling cables as per the details mentioned in the Scope of work. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56597173
AUTHORITY Government Departments
TENDER VALUE 17.63 Crore
LAST DATE 25-08-2026
Authority
Authority Name Indian Council Of Agricultural Research
Work Description Tender for Shifting Of Signalling And Telecom Infringed Cable In Connection With Badlapur-Karjat 3Rd & 4Th Line Under Mumbai Urban Transport Project-3B (Mutp-3B)
Basic Detail
Tender No MRVC/W/403
Bidding Type Tender
Location
City Thane
State Maharashtra
Key Dates
Publish Date 22 Jul 2026
Submission Date 25 Aug 2026
Open Date 25 Aug 2026
Finance
Tender Value 17.63 Crore
Tender Fee Ref. Documents
EMD 41.60 Lakhs
Exemption Available
Document List
73351e78-3122-41ec-8a17-3ea96aa88e1e.html
BOQ_964672.xls
SECTION1ITBMRVCW403.pdf
SECTION2BDS.pdf
SECTION3EQC.pdf
SECTION4BDF.pdf
SECTION5WRQ.pdf
SECTION6IRSGCC.pdf
SECTION7SCC.pdf
SECTION8COF.pdf
SECTION9BOQ.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 33 days
Aug 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 33 days

Tender Documents

Download All (ZIP) ↓
html

73351e78-3122-41ec-8a17-3ea96aa88e1e.html

xls

BOQ_964672.xls

pdf

SECTION1ITBMRVCW403.pdf

pdf

SECTION2BDS.pdf

pdf

SECTION3EQC.pdf

pdf

SECTION4BDF.pdf

pdf

SECTION5WRQ.pdf

pdf

SECTION6IRSGCC.pdf

pdf

SECTION7SCC.pdf

pdf

SECTION8COF.pdf

pdf

SECTION9BOQ.pdf

pdf

Tendernotice_1.pdf