Bids Are invited for Supply Andinstallation Of Power Supply Unit For Battery Charger For Electric Vehicle Purchased By Sj - Sitc Of Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonary Encloure With Cover Plat
Tender Overview
Project Description
Bids Are invited for Supply Andinstallation Of Power Supply Unit For Battery Charger For Electric Vehicle Purchased By Sj - Sitc Of Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonary Encloure With Cover Plate Having Locking Arranagement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal/Coke And Salt As Required , Sitc Of 25 Mm X 5 Mm Copper Strip At 0.50 Meter Below Ground As Strip Earth Electrode, Including Connection/Terminating With Nut, Bolt,Spring,Washer Etc. As Required.(Jointing Shall Be Done By Overlapping And With 2 Sets Of Brass Nut Bolt & Spring Washer Spaced At 50Mm) , Sitc Of Following Rating , Double Pole ,240V, Isolator In The Existing Mcb Db Complete With Connectios, Testing And Commissioning Etc. As Required. , Sitc Of Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Relase And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc.As Required. , Sitc Of Following Ways Surface / Recess Mounting, Vertical Type, 415 V ,Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Power Painted, Inclusive Of 200 A Tinned Copper Bus Bar , Common Neutral Link, Earth Bar , Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer) As Required. (Note :Vertical Type Mcb Tpdb Is Normally Used Whare 3 Phase Outlets Are Required) , Sitc Of 5A To 32 A Rating ,240/415V, 10Ka, C Curve ,Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc.As Required. , Sitc Of Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc, As Required. (But Without Mcb/Rccb/Isolator) , Providing And Laying Non Pressure Np-3 Class (Medium Duty) R.C.C. Pipes Including Collars/Spigot Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 (1 Cement: 2 Fine Sand) Including Testing Of Joints Etc. Complete , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recesssed Medium Class Pvc Conduit As Required. , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface /Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. , Sitc Of 4 Core Armoured Aluminium Conductor Cable Of Size 120 Sq. Mm In Existing Surface/Hume /Rcc/Metalpipe Complete With All Accessories/ Fitting As Required. , Excavation Trenches Of Required Width For Pipes Of Cables Etc Including Excavation For Sockets, Depth Upto 1.5M, Including Getting Out The Excavated Materials, Returning The Soil As Required In Layers Not Exceeding 20Cm In Depth, Including Consolidating Each Deposited Layers By Ramming, Watering Etc, Stacking Servicable Material For Measurements And Disposal Of Unservicable Material As Directed, Within A Lead Of 50Mtr.
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | SITC of copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary encloure with cover plate having locking arranagement and watering pipe of 2.7 meter long etc. with charcoal/coke and salt as required | SITC of copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary encloure with cover plate having locking arranagement and watering pipe of 2.7 meter long etc. with charcoal/coke and salt as required |
| 2 | SITC of 25 mm X 5 mm copper strip at 0.50 meter below ground as strip earth electrode, including connection/terminating with nut, bolt,spring,washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) | SITC of 25 mm X 5 mm copper strip at 0.50 meter below ground as strip earth electrode, including connection/terminating with nut, bolt,spring,washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 3 | SITC of following rating , double pole ,240V, isolator in the existing MCB DB complete with connectios, testing and commissioning etc. as required. | SITC of following rating , double pole ,240V, isolator in the existing MCB DB complete with connectios, testing and commissioning etc. as required. |
| 4 | SITC of following rating and breaking capacity and pole MCCB with thermomagnetic relase and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc.as required. | SITC of following rating and breaking capacity and pole MCCB with thermomagnetic relase and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc.as required. |
| 5 | SITC of following ways surface / recess mounting, vertical type, 415 V ,TPN MCB distribution board of sheet steel, dust protected, duly power painted, inclusive of 200 A tinned copper bus bar , common neutral link, earth bar , din bar for mounting MCBs ( but without MCBs and incomer) as required. (Note :Vertical type MCB TPDB is normally used whare 3 phase outlets are required) | SITC of following ways surface / recess mounting, vertical type, 415 V ,TPN MCB distribution board of sheet steel, dust protected, duly power painted, inclusive of 200 A tinned copper bus bar , common neutral link, earth bar , din bar for mounting MCBs ( but without MCBs and incomer) as required. (Note :Vertical type MCB TPDB is normally used whare 3 phase outlets are required) |
| 6 | SITC of 5A to 32 a rating ,240/415V, 10kA, \\"C\\" curve ,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc.as required. | SITC of 5A to 32 a rating ,240/415V, 10kA, \\"C\\" curve ,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc.as required. |
| 7 | SITC of following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (But without MCB/RCCB/Isolator) | SITC of following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (But without MCB/RCCB/Isolator) |
| 8 | Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete | Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete |
| 9 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recesssed medium class PVC conduit as required. | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recesssed medium class PVC conduit as required. |
| 10 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface /recess including cutting the wall and making good the same in case of recessed conduit as required. | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface /recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 11 | SITC of 4 core armoured aluminium conductor cable of size 120 sq. mm in existing surface/HUME /RCC/METALpipe complete with all accessories/ fitting as required. | SITC of 4 core armoured aluminium conductor cable of size 120 sq. mm in existing surface/HUME /RCC/METALpipe complete with all accessories/ fitting as required. |
| 12 | Excavation trenches of required width for pipes of cables etc including excavation for sockets, depth upto 1.5m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layers by ramming, watering etc, stacking servicable material for measurements and disposal of unservicable material as directed, within a lead of 50mtr. | Excavation trenches of required width for pipes of cables etc including excavation for sockets, depth upto 1.5m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layers by ramming, watering etc, stacking servicable material for measurements and disposal of unservicable material as directed, within a lead of 50mtr. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender