Power Boards / Undertakings / PSU Closing in 20 days TDR #56596234

Bids Are invited for Supply Andinstallation Of Power Supply Unit For Battery Charger For Electric Vehicle Purchased By Sj - Sitc Of Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonary Encloure With Cover Plat

Issued by Boards / Undertakings / PSU · Shimla, Himachal Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
12 Aug 2026
20 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Shimla → Himachal Pradesh
EMD Exemption
Available
Quantity
1

Project Description

Bids Are invited for Supply Andinstallation Of Power Supply Unit For Battery Charger For Electric Vehicle Purchased By Sj - Sitc Of Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonary Encloure With Cover Plate Having Locking Arranagement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal/Coke And Salt As Required , Sitc Of 25 Mm X 5 Mm Copper Strip At 0.50 Meter Below Ground As Strip Earth Electrode, Including Connection/Terminating With Nut, Bolt,Spring,Washer Etc. As Required.(Jointing Shall Be Done By Overlapping And With 2 Sets Of Brass Nut Bolt & Spring Washer Spaced At 50Mm) , Sitc Of Following Rating , Double Pole ,240V, Isolator In The Existing Mcb Db Complete With Connectios, Testing And Commissioning Etc. As Required. , Sitc Of Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Relase And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc.As Required. , Sitc Of Following Ways Surface / Recess Mounting, Vertical Type, 415 V ,Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Power Painted, Inclusive Of 200 A Tinned Copper Bus Bar , Common Neutral Link, Earth Bar , Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer) As Required. (Note :Vertical Type Mcb Tpdb Is Normally Used Whare 3 Phase Outlets Are Required) , Sitc Of 5A To 32 A Rating ,240/415V, 10Ka, C Curve ,Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc.As Required. , Sitc Of Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc, As Required. (But Without Mcb/Rccb/Isolator) , Providing And Laying Non Pressure Np-3 Class (Medium Duty) R.C.C. Pipes Including Collars/Spigot Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 (1 Cement: 2 Fine Sand) Including Testing Of Joints Etc. Complete , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recesssed Medium Class Pvc Conduit As Required. , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface /Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. , Sitc Of 4 Core Armoured Aluminium Conductor Cable Of Size 120 Sq. Mm In Existing Surface/Hume /Rcc/Metalpipe Complete With All Accessories/ Fitting As Required. , Excavation Trenches Of Required Width For Pipes Of Cables Etc Including Excavation For Sockets, Depth Upto 1.5M, Including Getting Out The Excavated Materials, Returning The Soil As Required In Layers Not Exceeding 20Cm In Depth, Including Consolidating Each Deposited Layers By Ramming, Watering Etc, Stacking Servicable Material For Measurements And Disposal Of Unservicable Material As Directed, Within A Lead Of 50Mtr.

BOQ

Sl. No. Item TitleItem Description
1SITC of copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary encloure with cover plate having locking arranagement and watering pipe of 2.7 meter long etc. with charcoal/coke and salt as requiredSITC of copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary encloure with cover plate having locking arranagement and watering pipe of 2.7 meter long etc. with charcoal/coke and salt as required
2SITC of 25 mm X 5 mm copper strip at 0.50 meter below ground as strip earth electrode, including connection/terminating with nut, bolt,spring,washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)SITC of 25 mm X 5 mm copper strip at 0.50 meter below ground as strip earth electrode, including connection/terminating with nut, bolt,spring,washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
3SITC of following rating , double pole ,240V, isolator in the existing MCB DB complete with connectios, testing and commissioning etc. as required.SITC of following rating , double pole ,240V, isolator in the existing MCB DB complete with connectios, testing and commissioning etc. as required.
4SITC of following rating and breaking capacity and pole MCCB with thermomagnetic relase and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc.as required.SITC of following rating and breaking capacity and pole MCCB with thermomagnetic relase and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc.as required.
5SITC of following ways surface / recess mounting, vertical type, 415 V ,TPN MCB distribution board of sheet steel, dust protected, duly power painted, inclusive of 200 A tinned copper bus bar , common neutral link, earth bar , din bar for mounting MCBs ( but without MCBs and incomer) as required. (Note :Vertical type MCB TPDB is normally used whare 3 phase outlets are required)SITC of following ways surface / recess mounting, vertical type, 415 V ,TPN MCB distribution board of sheet steel, dust protected, duly power painted, inclusive of 200 A tinned copper bus bar , common neutral link, earth bar , din bar for mounting MCBs ( but without MCBs and incomer) as required. (Note :Vertical type MCB TPDB is normally used whare 3 phase outlets are required)
6SITC of 5A to 32 a rating ,240/415V, 10kA, \\"C\\" curve ,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc.as required.SITC of 5A to 32 a rating ,240/415V, 10kA, \\"C\\" curve ,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc.as required.
7SITC of following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (But without MCB/RCCB/Isolator)SITC of following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (But without MCB/RCCB/Isolator)
8Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. completeProviding and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete
9Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recesssed medium class PVC conduit as required.Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recesssed medium class PVC conduit as required.
10Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface /recess including cutting the wall and making good the same in case of recessed conduit as required.Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface /recess including cutting the wall and making good the same in case of recessed conduit as required.
11SITC of 4 core armoured aluminium conductor cable of size 120 sq. mm in existing surface/HUME /RCC/METALpipe complete with all accessories/ fitting as required.SITC of 4 core armoured aluminium conductor cable of size 120 sq. mm in existing surface/HUME /RCC/METALpipe complete with all accessories/ fitting as required.
12Excavation trenches of required width for pipes of cables etc including excavation for sockets, depth upto 1.5m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layers by ramming, watering etc, stacking servicable material for measurements and disposal of unservicable material as directed, within a lead of 50mtr.Excavation trenches of required width for pipes of cables etc including excavation for sockets, depth upto 1.5m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layers by ramming, watering etc, stacking servicable material for measurements and disposal of unservicable material as directed, within a lead of 50mtr.

AI Tender Summary

OUR REF NO 56596234
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 12-08-2026
Authority
Authority Name Sjvn Limited
Work Description Bids Are invited for Supply Andinstallation Of Power Supply Unit For Battery Charger For Electric Vehicle Purchased By Sj - Sitc Of Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonary Encloure With Cover Plate Having Locking Arranagement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal/Coke And Salt As Required , Sitc Of 25 Mm X 5 Mm Copper Strip At 0.50 Meter Below Ground As Strip Earth Electrode, Including Connection/Terminating With Nut, Bolt,Spring,Washer Etc. As Required.(Jointing Shall Be Done By Overlapping And With 2 Sets Of Brass Nut Bolt & Spring Washer Spaced At 50Mm) , Sitc Of Following Rating , Double Pole ,240V, Isolator In The Existing Mcb Db Complete With Connectios, Testing And Commissioning Etc. As Required. , Sitc Of Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Relase And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc.As Required. , Sitc Of Following Ways Surface / Recess Mounting, Vertical Type, 415 V ,Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Power Painted, Inclusive Of 200 A Tinned Copper Bus Bar , Common Neutral Link, Earth Bar , Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer) As Required. (Note :Vertical Type Mcb Tpdb Is Normally Used Whare 3 Phase Outlets Are Required) , Sitc Of 5A To 32 A Rating ,240/415V, 10Ka, C Curve ,Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc.As Required. , Sitc Of Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc, As Required. (But Without Mcb/Rccb/Isolator) , Providing And Laying Non Pressure Np-3 Class (Medium Duty) R.C.C. Pipes Including Collars/Spigot Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 (1 Cement: 2 Fine Sand) Including Testing Of Joints Etc. Complete , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recesssed Medium Class Pvc Conduit As Required. , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface /Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. , Sitc Of 4 Core Armoured Aluminium Conductor Cable Of Size 120 Sq. Mm In Existing Surface/Hume /Rcc/Metalpipe Complete With All Accessories/ Fitting As Required. , Excavation Trenches Of Required Width For Pipes Of Cables Etc Including Excavation For Sockets, Depth Upto 1.5M, Including Getting Out The Excavated Materials, Returning The Soil As Required In Layers Not Exceeding 20Cm In Depth, Including Consolidating Each Deposited Layers By Ramming, Watering Etc, Stacking Servicable Material For Measurements And Disposal Of Unservicable Material As Directed, Within A Lead Of 50Mtr.
Basic Detail
Tender No GEM/2026/B/7816908
Bidding Type Tender
Location
City Shimla
State Himachal Pradesh
Key Dates
Publish Date 22 Jul 2026
Submission Date 12 Aug 2026
Open Date 12 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Available
Document List
ff40d3d3-e51d-4eed-99b3-ff930c2fb112.pdf
1784636031.xlsx
ATC_3760b13f-d648-43dc-a7071784697784618_susheel_sharma.docx
boq_2026-07-21-16-20-15_efa37b768386afe54696ed58717d79a5.xlsx

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Aug 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
pdf

ff40d3d3-e51d-4eed-99b3-ff930c2fb112.pdf

xlsx

1784636031.xlsx

docx

ATC_3760b13f-d648-43dc-a7071784697784618_susheel_sharma.docx

xlsx

boq_2026-07-21-16-20-15_efa37b768386afe54696ed58717d79a5.xlsx

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders