Tender For Addition Alteration To P 11O Building At Hq Sac U
Tender Value
43.65 Lakhs
Estimated cost
Bid Submission
11 Aug 2026
14 days left
EMD
87300
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvananthapuram → Kerala
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Addition Alteration To P 11O Building At Hq Sac U
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth for foundation etc n exc 10 sqm on plan and getting out in hard/dense soil, complete all as specified and directed. |
| 2 | M&L for returning, filling including spreading , levelling watering and well ramming in layers nex 25cm in hard and dense soil, complete all as specified and directed. |
| 3 | Removing excavated material exc 250m and n exc 500m and depositing where directed. |
| 4 | M&L for PCC (1:4:8 ) Type D2 using 40mm graded stone aggregate as in foundation, sub-base under floor and mass concrete, complete all as specified and directed . |
| 5 | M&L for precast cement concrete 1;3:6 type C1 using 20mm graded stone aggregate solid block masonry exc 10cm in width and setting in cement mortar 1:6, complete all as specified and directed. |
| 6 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed . Note : The tiled floor has to be demolished/ dismantled entirely up to the sub base level/ RCC floor level including backing coat irrespective of number of layers of tiles and taking down wall plaster also including in wall tiles. |
| 7 | M&L for Vitrified Ceramic tiles light shade 8-10mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm and not exc 1.00 sqm in floors, skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 8 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed. |
| 9 | M&L for 15mm thick screed bed or bedding layer in CM 1:6 for laying floor finishes complete all as specified and directed. |
| 10 | M&L PCC 1:2:4 type B0 (12.5mm graded aggregate) 25mm thick as in floor sub base for receiving of floor tiles complete all as specified and directed. |
| 11 | M&L for Glazed ceramic coloured tiles/Wall cladding tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed. Note: The above mentioned size of tiles not available in market then contractor provide higher size/ dimension of tiles without extra payment. |
| 12 | M&L for rendering 10mm thick on fair faces of brick work in CM 1:4 as backing coat to receive tiles complete all as specified and directed. |
| 13 | Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 14 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and directed. |
| 15 | M&L for 18-20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 16 | M&L for 15mm thick screed bed or bedding layer in CM 1:4 for laying floor finishes complete all as specified and directed. |
| 17 | Demolition of brickwork or stone/ boulder masonry, built in cement or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 18 | M&L for Brickwork with sub- class ‘B’ old size bricks straight or curved on plan exc 6 m mean radius in CM 1:6, complete all as specified and directed. |
| 19 | M&L for Brickwork with subclass ‘B’ old size bricks, straight or curved on plan to any radius in half brick thick walls, built in M 1:4, complete all as specified and directed. |
| 20 | Taking down cement or cement lime plaster of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 21 | M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed. |
| 22 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 23 | S&F rolled mild steel work as in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. |
| 24 | S&F mild steel work as framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 25 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement etc, complete all as specified and directed. |
| 26 | M&L preparation of new steel surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc crome complete all as specified and directed. |
| 27 | M&L for fixing in repairs 12mm thick Toughened glass for doors, partitions automatic doors & similar work including cutting to shape, drilling holes and including necessary fittings i.e. stainless steel hinges, SS 'H' or 'S' type handles, Pivot, top and bottom patch and patch lock etc and also including for spring if required, complete all as specified and directed. Note : The rate shall be inclusive all fittings required at site and as approved to the entire satisfaction of Engineer-in-Charge/GE. |
| 28 | S&F 3mm thick Aluminium Composite Panels (ACP) of exterior grade for cladding for external wall/column/canopy cladding in combination of solid and metallic colours over a steel frame work fixed with ss screws and complete weather sealing, complete all as specified and directed. Make : - Alucobond/ Alstrong/ Eurobond or approved equivalent. |
| 29 | Taking down cement plaster including existing roof treatment or fillets on roof surfaces and wall surfaces complete, racking out joints, hacking for key scrubbing down with water etc and removing rubbish to a distance exc 250m and not exc 500m all as specified and as directed. |
| 30 | M&L PCC 1:2:4 type B0 using 12.5mm graded stone aggregate as in padding concrete for roof ,Plinth course,copings,string courses, water troughs and the like finished even and smooth including necessary formwork,weathering,slightly rounded or chamfered angles and throating ,complete all as specified and directed . |
| 31 | M&L for 15 mm thick rendering in cement mortar 1:4 on fair surfaces of brick masonry or concrete surface, finished the surface even and smooth with using extra cement incl using WPC as per manufacturers instructions, complete all as specified and directed. Note : WPC shall be measured and paid separately. |
| 32 | Supply only liquid waterproofing compound (ISI grade only),complete all as specified and directed . |
| 33 | M&L for applying two component, cold(brush/roller) applied, UV resistant hybrid Polyurethane waterproof coating on existing roof screed/plaster surface including equipments and supervision charges in following step by (i) Roof substrate must be pressure-washed with water with, a minimum working pressure of 1,400 psi is to be used to remove all dirt, dust, chalking and waste products, complete all as specified and directed . (ii) Inspect for cracks over roof screed, roof wall junction, water drain inlets/outlets if any, and clean and moisten them. Crack’s width should be wide up to 5-6 mm with mechanical cutting machine and Apply bond coat of SBR Latex in the ratio of 1:1 (URP 1: Cement 1) followed by groove should be filled with PMM by preparing Polymer modified mortar of CM 1:1 (Silica sand size ≤ 300microns) admixed with SBR Latex at a dosage of 15% of cement.(iii) Providing 300mm x 300 mm Square / rectangle upstand of M20 grade concrete or with PMM around mechanical equipment like HVAC, air conditioning, solar panels. Etc. Apply a coat of two component, cold(brush/roller) applied, UV resistant hybrid Polyurethane waterproof coating allow to cure for 3-4 hours and followed by apply two coats two component, cold(brush/roller) applied, UV resistant hybrid Polyurethane waterproof coating reinforced with 45 Gsm glass fiber mesh or geo textile without dilution in the interval of 4 -6 hrs. Apply Hybrid PU Sealant at around the junction of fabricated stand inserted and wall mounting mechanical fixtures.(iv) Providing Minimum 50mm thick angle fillet with CM of 1:3 admixed with SBR Latex at a dosage of 12-15% of Cement and a bond coat of SBR Latex mixed with Cement at a ratio of 1:1.(v) Premix hybrid Polyurethane waterproof coating components A and B with an electric double paddle mixer stirrer for 2-3 minutes at a slow speed. The concrete surface must be brought into surface saturated dry condition (SSD). Providing and apply first coat of two component, cold(brush/roller) applied, UV resistant hybrid Polyurethane waterproof coating to the existing screed/plaster at a rate of 0.5Kg/sq.mt/coat. Place a 45-GSM glass fiber mesh or 200- 225 GSM raw mesh between the first and second coats while the first coat is still wet. Allow the first coat to dry for 3-4 hours. Apply the second and third coats of two component, cold(brush/roller) applied, |
| 34 | item no 33 ctd...UV resistant hybrid Polyurethane waterproof coating with the same application coverage, but in a direction perpendicular to that of the first and second coats. Allow each coat to air cure for a minimum of 3-4 hours after application. Ensure that no void surface is left untreated or uncoated. All coats should be applied in directions perpendicular to each other, ensuring the correct consumption of material, resulting in a total dry film thickness of 1000 microns with system coverage in three undiluted coats at a rate of 1.50 Kg/ sq.mt/coat. Allow the system to air cure for 5-7 days minimum. The material should conform to the specified technical properties:a) Tensile Strength with Fiber ≥9N/mm2 as per ASTM D 2370b) Elongation at break ≥ 200% as per ASTM D 2370c) Crack bridging ability ≥ 3mm as per EN 1062-7-2004(A) d) solid content ≥55% as per ASTM D 1,644-2001e) Abrasion resistance 15mg confirming to ASTM D 4060f) Shore-A 65 as per ASTM D2240 g) Tear Resistance with Fiber 40N/mm as per ASTM D 624.The waterproofing coating shall be applied over the entire horizontal surface and extended onto the vertical surface of the parapet wall, as per the manufacturer methodology as directed by GE/Engineer-in-Charge.Note: All waterproofing work suggested above shall be carried out by the in house application wing of the manufacturer or skilled waterproofing contractor under the guidance of a technical expert from the manufacturer. The technical expert should audit the quality of the waterproofing work and submit the report. The contractor should submit the skilled project waterproofed certificate issued from the manufacturer while receiving the work order. |
| 35 | M&L Roof tiles Mangalore pattern interlocking at side joints laid dry complete all as specified and directed. |
| 36 | M&L Ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and pointed in cement mortar 1:6,complete all as specified and directed . |
| 37 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/ slabs/blankets, any thickness, including any type frame work and cover fillets etc, complete all as specified and directed |
| 38 | M&l for 5mm thick WPC wall panelling colour WPC sheet fixed with steel screws, screws with wood plugs or high quality adhesive complete all as specified and directed. Note : - Necessary framework will be measured and paid separately under respective item. |
| 39 | M&L for 2nd class hard wood plain fillets. square, rectangular or triangular in section, clean sawn, secured with nails, screws, fasterners or brads exc 13 but not exc 25 sqcm complete all as specified and directed . |
| 40 | M&L for providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions to flat surface over GI frame work seamless perimeter 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre and including hangers 6mm dia G.I (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I flat 40x3 mm mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long and including preparation of ceiling surfaces and two coats of OBD over 1mm thick acrylic putty, complete all as specified and directed.Note : Rate inclusive all type of design i.e. offsets and projection. The area measured only length and width of room and building. Design of ceiling approved by Engineer-in-charge /GE. |
| 41 | M&L for false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of size 595x595mm of approved texture, design and patterns, to be laid in true horizontal level suspended on inter locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanised @ 120 grams per sqm per including both sides) comprising of main -T runners of size 24 x 38 mm of length 3000mm, cross -T of size 24x32mm length 1200mm and secondary intermediate cross -T of size 24x32mm of length 600mm to form grid module of size 600x600mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80grams per sqm) i.e. 12x50mm long dash fasteners, 6mm dia fully threaded hanger rod upto 1000 mm length and L-Shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with pre-cut hole on both 25 mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with galvanised iron perimeter wall angle or size 24x24x0.40mm of length 3000mm to be fixed on periphery wall/ partition with the help of plastic rawl plugs at 450mm center to center and 40mm long dry wall S.S screws.With 15mm thick regular/butt edged without perforation plain/designer light weight calcium silicate Anti-Microbial Bio-Safe coated false ceiling tiles confirming to JIS-Z 2801 and ASTM G-21, complete all as specified and directed. |
| 42 | Material and labour for Preparation of old decorated surfaces (plastered/unplastered) of walls/pillars /cornices by remove / scraping down all smoke soot, moulds, moss & efflorescent salts, oil & greasy spots etc with using steel patti/wire brush/broom/ mechanical sander machine (including provision of dust sucking), upto entire satisfaction of Engineer-in-charge, and after preparing the surface smooth applying one coat of lime white wash with using paint brush complete all as specified and as directed. |
| 43 | Material and labour for Preparation of old decorated surfaces (plastered/unplastered) of ceiling by remove / scraping down all smoke soot, moulds, moss & efflorescent salts, oil & greasy spots etc with using steel patti/wirebrush/broom/ mechanical sander machine (including provision of dust sucking), upto entire satisfaction of Engineer-in-charge, and after preparing the surface smooth applying one coat of lime white wash with using paint brush complete all as specified and as directed . |
| 44 | Complete removal of existing treatment on wall, complete all as specified and directed. |
| 45 | M&L for Providing and applying 3mm wall care putty on wall surface and achieve the surface even and smooth complete all as specified and as directed. |
| 46 | M&L for preparation new putty and plaster wall surfaces and applying two coats of Acrylic emulsion distemper on wall surface over a coat of primer complete all as specified and directed. |
| 47 | Material and labour for Preparation of old decorated surfaces (plastered/unplastered) of walls/pillars /cornices by remove / scraping down all smoke soot, moulds, moss & efflorescent salts, oil & greasy spots etc with using steel patti/wirebrush/broom/ mechanical sander machine (including provision of dust sucking), upto entire satisfaction of Engineer-in-charge, and after preparing the surface smooth and one coat of Acrylic emulsion distemper with using paint brush, as per existing or as approved tint/colour complete all as specified and as directed . |
| 48 | Material and labour for preparation of old painted wooden surfaces of any description not otherwise described over 10cm width or girth & applying one coat of synthetic enamel paint (1st quality) of approved tint/colour to achieve glossing finish complete as specified and as directed as per existing or as approved tint/colur complete all as specified and as directed . Please Enable Macros to View BoQ information |
| 49 | Material and labour for preparation of old painted wooden surfaces of any description not otherwise described over 10cm width or girth & applying one coat of synthetic enamel paint (1st quality) of approved tint/colour to achieve glossing finish complete as specified and as directed as per existing or as approved tint/colur complete all as specified and as directed . Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysAug 13, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender