Tender For Construction Of Goshala At Kendijhar Nizigarh Village In Keonjhargarh Municipality
Tender Value
6.21 Crore
Estimated cost
Bid Submission
12 Aug 2026
14 days left
EMD
6.21 Lakhs
Bank guarantee accepted
Document Fee
11800
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kendujhar → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Goshala At Kendijhar Nizigarh Village In Keonjhargarh Municipality
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation of foundation trenches in all kids of soil including dressing and levelling the bed upto the required depth and depositing the excaveted materials with all leads & lifts T&P shoring and shuttering watering if necessary etc. complete as per directed by the Engineer-in-charge |
| 2 | Filling foundation trenches with excavated earth including watering ramming and compacting in layer not exceeding 150 mm thick including labour sundries T & P etc complete and as per direction of Engineer-in- charge |
| 3 | Supplying & filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyance, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc., complete (Measurement will be taken on finished compacted section) as per specification and diregtion of Engineer-in-charge. |
| 4 | C.C (1:3:6) with 4cm size HG Crusher BROKEN metal including ali cost, conveyarice,royaity & taxes etc.comp.to work site as per Specification approved by the department & direction of E.I.C. |
| 5 | Brick work with Fly Ash bricks of size 23cmx11cmx8cm and crushing strength not less than 75 kg/cm2 in C.M.(1:6) in foundation and plinth including all charges etc.complete as per the direction of Engineer-In-Charge |
| 6 | Providing, lifting, hoisting and laying Reinforoad Comer Concrsis of M-25 grade in Column base, Column Footings, Raft Foundation,Stem of the Columns, beams, chaujja, fin, lintel, stair Case, jali , shelves and slab etc as per approved designs and drawings having a minimum Compressive strength ( in work test) 20N. / Square mm. in 15cm. cubes at 28 days after mixing and test conducted in accordance with 1.S. 456 and 1.S. 516 using screened & washed sharp Hiver sand far mertar and 18mm. to 20 mm. size black hand crusher broken ect but the excluding cost & conveyance of M.S. rods or Tor Stee! and Binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel and binding wires and tying the grills and placing in. proper position as directed by the Engineer-in-charge. Column Footing |
| 7 | Column |
| 8 | Plinth Bend |
| 9 | Cutting, Straightening coiled or bent up M.S plain HYSD/TMT reinforcement bars welding or| jointing if necessary bending,binding,tying the grills as required for R.C.C works,providing fan hooks where necessary and hoisting, lowering and placing in proper position according to approved designs and drawings including cost,canveyance,loading,..unloading & taxes of M.S PlaiwHYSD/TMT reinforcement bars and binding wires of 18 to 20 gaugo required for the work and cost of all labour, sundries, TP and Scaffolding complete in alt respect as directed by the Engineer in charge (payment will be made according to the actual weight of M.SPiainHYSD/TMT reinforcement bars consumed in the work only. |
| 10 | Rigid & smooth centering & shuttering for RCC work including false works and dismantling them after casting including cost of materials complete in ground floor.Column Footing |
| 11 | Column |
| 12 | Plinth Bend |
| 13 | Brick work with Fly Ash bricks 23cm x 11cm x 8cm size having crusing Strength not less then 75kg/cm2 in cement mortar (1:6) in superstructure including all cost complete as per direction of Enginner-In-Charge. |
| 14 | Brick work with Fly Ash bricks 23cm x 11cm x 8cm size having crusing strength not less then 75Kg/cm2 in cement mortar (1:4) in superstructure of 5\\" partition wall including all cost complete as per direction of Engineer-In-Charge. |
| 15 | Providing 12mm thick cement plaster in cement mortar (1:6) in all floors finished smooth to out, Side smooth surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface Smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required omamental finish as per drawing, watering, curing, Scaffolding, screening sand etc. complete with cost, conveyances, royalties, taxes of all materials and cost of all Jabour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge |
| 16 | 16mm thick cement plaster (1:6) on brick work inside wall including all cost conveyance royalty & taxes etc, to work site as per direction of Engineer-In-Charge |
| 17 | Wall painting 2 coats with weather coat inside and out side smooth surface with all cost of labour, T&P material etc complete |
| 18 | Supplying and laying 2.5cm artificial stone flooring with cement concrete (1:2:4) including punning using 12 mm size crusher broken granites chips |
| 19 | 12mm thick cement plaster with C.M (1:4) with punning including cost of all materials curing etc. complete. |
| 20 | Supplying, Manufacturing, fabricating & assembling of frame structure at stage area with circular/square hollow steel tube section of TATA STRUCTURE shall conform to CHS-IS-1161 & 22 |SHS/RHS of 1S 4923 grade for shed component viz, column, truss, purlin ete as per approved drawing including two coat of primer & two coal uf enamel painting |
| 21 | Providing and “fixing precoated galvanised iron profile sheets (size, shape and pitch off corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should 73 joe Supplied in single tength- upto 12 metre cr as desired. by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch In horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 22 | Priming one coat with any approved primer for structuralsteel including all cost as per direction of Engineer-In-Charge. |
| 23 | FOR 4 UNITS OF GOSHALA SHED |
| 24 | Earth work in excavation of foundation trenches in all kids of soil including dressing and levelling the bed upto the required depth and depositing the excaveted materials with all leads & lifts T&P shoring and shuttering watering if necessary etc. complete as per directed by the Engineer-in-charge |
| 25 | Filling foundation trenches with excavated earth including watering ramming and compacting in layer not exceeding 150 mm thick including labour sundries T & P etc complete and as per direction of Engineer-in- charge Quantity 2/3 of Earth Work |
| 26 | Deduct(-) |
| 27 | Supplying & filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyance, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc., complete (Measurement will be taken on finished compacted section) as per specification and diregtion of Engineer-in-charge. |
| 28 | C.C (1:3:6) with 4cm size HG Crusher BROKEN metal including ali cost, conveyarice,royaity & taxes etc.comp.to work site as per Specification approved by the department & direction of E.I.C. |
| 29 | Brick work with Fly Ash bricks of size 23cmx11cmx8cm and crushing strength not less than 75 kg/cm2 in C.M.(1:6) in foundation and plinth including all charges etc.complete as per the direction of Engineer-In-Charge |
| 30 | Providing, lifting, hoisting and laying Reinforoad Comer Concrsis of M-25 grade in Column base, Column Footings, Raft Foundation,Stem of the Columns, beams, chaujja, fin, lintel, stair Case, jali , shelves and slab etc as per approved designs and drawings having a minimum Compressive strength ( in work test) 20N. / Square mm. in 15cm. cubes at 28 days after mixing and test conducted in accordance with 1.S. 456 and 1.S. 516 using screened & washed sharp Hiver sand far mertar and 18mm. to ng, bending etc. of M.S. rods or Tor steel and binding wires and tying the grills and placing in. proper position as directed by the Engineer-in-charge. Column Footing |
| 31 | Column |
| 32 | Plinth Bend |
| 33 | Lintel |
| 34 | Roof Beam |
| 35 | Roof Slab |
| 36 | Chhaja |
| 37 | Cutting, Straightening coiled or bent up M.S plain HYSD/TMT reinforcement bars welding or| jointing if necessary bending,binding,tying the grills as required for R.C.C works,providing fan hooks where necessary and hoisting, lowering and placing in proper position according to approved designs and drawings including cost,canveyance,loading,..unloading & taxes of M.S PlaiwHYSD/TMT reinforcement bars and binding wires of 18 to 20 gaugo required for the work and cost of all labour, sundries, TP and Scaffolding complete in alt respect as directed by the Engineer in charge (payment will be made according to the actual weight of M.SPiainHYSD/TMT reinforcement bars consumed in the work only. |
| 38 | Rigid & smooth centering & shuttering for RCC work including false works and dismantling them after casting including cost of materials complete in ground floor.Column Footing |
| 39 | column |
| 40 | Plinth Beam |
| 41 | Lintel |
| 42 | Roof beam |
| 43 | Roof Slab |
| 44 | Chhaja |
| 45 | Brick work with Fly Ash bricks 23cm x 11cm x 8cm size having crusing Strength not less then 75kg/cm2 in cement mortar (1:6) in superstructure including all cost complete as per direction of Enginner-In-Charge. |
| 46 | Providing 12mm thick cement plaster in cement mortar (1:6) in all floors finished smooth to out, Side smooth surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface Smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required omamental finish as per drawing, watering, curing, Scaffolding, screening sand etc. complete with cost, conveyances, royalties, taxes of all materials and cost of all Jabour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge |
| 47 | 16mm thick cement plaster (1:6) on brick work inside wall including all cost conveyance royalty & taxes etc, to work site as per direction of Engineer-In-Charge |
| 48 | 6mm thick cement plaster (1:6) on brick work inside wall including all cost conveyance royalty & taxes etc, to work site as per direction of Engineer-In-Charge |
| 49 | Wall painting 2 coats with weather coat inside and out side smooth surface with all cost of labour, T&P material etc complete. |
| 50 | Finishing wall surface with plastic emulsion paint 2 coat over a coat of primer to the new surfaces of walls with including all cost as per direction of Engineer-in-charge. |
| 51 | M.S. Grill gate made out of M.S. flat conforming to |S 2062/20006 painted with red oxide primer as pe the design approved. |
| 52 | Painting with Red oxide primer one coat over m.s. work grill with all cost complete as per direction of Engineer-in-charge. |
| 53 | Painting two coats with approved synthetic enamel paints of Asian / Berger/Dulox make and of approved colour, shade to new Iron including sand papering, polishing the surface, cost, conveyances, taxes of all materials and cost of all labour with T&P etc, complete as per spectfication & direction of Engineer-in-charge. Note :-- Sample of Paint & Primer shall be approved before procurement and use. |
| 54 | Supplying all materials, labour T&P and fixing of fabricated M.S door, windows & grill in wall including cutting of brick masonary wall, fixing of door, windows, grill by providing C.C ( 1:2:4 ), Plastering to the damaged portion but exculding the cost of M.S work. |
| 55 | 2.5 cm thick grading concrete (1:2:2) on roof slab with 6mm size hard granite chips complete all as per direction of Engineer-in-Charge. |
| 56 | Supplying and laying 2.5cm artificial stone flooring with cement concrete (1:2:4) including punning using 12 mm size crusher broken granites chips |
| 57 | FOR 3 UNITS OF SORAGE BUIKDING |
| 58 | Earth work in excavation of foundation trenches in all kids of soil including dressing and levelling the bed upto the required depth and depositing the excaveted materials with all leads & lifts T&P shoring and shuttering watering if necessary etc. complete as per directed by the Engineer-in-charge |
| 59 | Filling foundation trenches with excavated earth including watering ramming and compacting in layer not exceeding 150 mm thick including labour sundries T & P etc complete and as per direction of Engineer-in- charge Quantity 2/3 of Earth work |
| 60 | Column Footing |
| 61 | Supplying & filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyance, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc., complete (Measurement will be taken on finished compacted section) as per specification and diregtion of Engineer-in-charge. |
| 62 | C.C (1:3:6) with 4cm size HG Crusher BROKEN metal including ali cost, conveyarice,royaity & taxes etc.comp.to work site as per Specification approved by the department & direction of E.I.C. |
| 63 | Brick work with Fly Ash bricks of size 23cmx11cmx8cm and crushing strength not less than 75 kg/cm2 in C.M.(1:6) in foundation and plinth including all charges etc.complete as per the direction of Engineer-In-Charge |
| 64 | Providing, lifting, hoisting and laying Reinforoad Comer Concrsis of M-25 grade in Column base, Column Footings, Raft Foundation,Stem of the Columns, beams, chaujja, fin, lintel, stair Case, jali , shelves and slab etc as per approved designs and drawings having a minimum Compressive strength ( in work test) 20N. / Square mm. centering and shuttering then after {dismantfing and removing the debrises away from the work site and finishing the ll respect but the excluding cost & conveyance of M.S. rods or Tor Stee! and Binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel and binding wires and tying the grills and placing in. proper position as directed by the Engineer-in-charge.Column Footing |
| 65 | Column |
| 66 | Plinth Beam |
| 67 | Lintel |
| 68 | Roof Beam |
| 69 | Roof Slab |
| 70 | Chhaja |
| 71 | Cutting, Straightening coiled or bent up M.S plain HYSD/TMT reinforcement bars welding or| jointing if necessary bending,binding,tying the grills as required for R.C.C works,providing fan hooks where necessary and hoisting, lowering and placing in proper position according to approved designs and drawings including cost,canveyance,loading,..unloading & taxes of M.S PlaiwHYSD/TMT reinforcement bars and binding wires of 18 to 20 gaugo required for the work and cost of all labour, sundries, TP and Scaffolding complete in alt respect as directed by the Engineer in charge (payment will be made according to the actual weight of M.SPiainHYSD/TMT reinforcement bars consumed in the work only. |
| 72 | Rigid & smooth centering & shuttering for RCC work including false works and dismantling them after casting including cost of materials complete in ground floor.Column Footing |
| 73 | Column |
| 74 | Plinth Beam |
| 75 | Lintel |
| 76 | Roof Beam |
| 77 | Roof Slab |
| 78 | Chhaja |
| 79 | Brick work with Fly Ash bricks 23cm x 11cm x 8cm size having crusing Strength not less then 75kg/cm2 in cement mortar (1:6) in superstructure including all cost complete as per direction of Enginner-In-Charge. |
| 80 | Providing 12mm thick cement plaster in cement mortar (1:6) in all floors finished smooth to out, Side smooth surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface Smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required omamental finish as per drawing, watering, curing, Scaffolding, screening sand etc. complete with cost, conveyances, royalties, taxes of all materials and cost of all Jabour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge |
| 81 | Providing 16mm thick cement plaster in cement mortar (1:6) in all floors finished smooth to out, Side smooth surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface Smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required omamental finish as per drawing, watering, curing, Scaffolding, screening sand etc. complete with cost, conveyances, royalties, taxes of all materials and cost of all Jabour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge |
| 82 | Providing 6mm thick cement plaster in cement mortar (1:6) in all floors finished smooth to out, Side smooth surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface Smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required omamental finish as per drawing, watering, curing, Scaffolding, screening sand etc. complete with cost, conveyances, royalties, taxes of all materials and cost of all Jabour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge |
| 83 | Wall painting two coat with weather coat paint of approved shade on new work to give an even shade including cost of paint as per direction of Engineer-in-charge. |
| 84 | Inside wall painting with plastic paint two coat of approved shade over a coat of primer on new work to give an even shade including cost of paint as per direction of Engineer-in-charge. |
| 85 | Providing & Fixing M.S. Grill made out of M.S. flat conforming to |S 2062/20006 painted with red oxide primer as pe the design approved as per direction of Engineer-in-charge. |
| 86 | Painting two coats with approved synthetic enamel paints of Asian / Berger/Dulox make and of approved colour, shade to new Iron including sand papering, polishing the surface, cost, conveyances, taxes of all materials and cost of all labour with T&P etc, complete as per spectfication & direction of Engineer-in-charge. Note :-- Sample of Paint & Primer shall be approved before procurement and use. |
| 87 | Providing fitting and fixing W.I. clamp of approved size with cost of all materials labor etc. complete as per direction of Engineer-in-charge. |
| 88 | Supplying all materials, labour T&P and fixing of fabricated M.S door, windows & grill in wall including cutting of brick masonary wall, fixing of door, windows, grill by providing C.C ( 1:2:4 ), Plastering to the damaged portion but exculding the cost of M.S work. |
| 89 | Providing & Painting Red oxide primer one coat over iron work with all cost of labour & materials etc. complete as per direction of Engineer-in-charge. |
| 90 | Providing & Painting Syenthetic Enamel Paint two coats over iron work including all cost of labour and materials etc complete as per direction of Engineer-in-charge. |
| 91 | Providing Pvc door with frame of PVC make with good quality make including all cost as per direction of Engineer-in-charge etc.complete. |
| 92 | Supplying and laying 2.5cm artificial stone flooring with cement concrete (1:2:4) including punning using 12 mm size crusher broken granites chips |
| 93 | Providing 2.5 cm thick grading concrete (1:2:2) on roof slab with 6mm size hard granite chips complete all cost as per direction of Engineer-in-Charge. |
| 94 | Fixing of vetrified tiles in floors of Size 600x600mm of approved make coformaing to I.S:13755 laid on on 25mm thick bed of Cement mortar 1:4 ( 1 Cement : 4 sand ) and filling joint with white Cement of approved quality in slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of tiles or stones. ( For new work)with cost of all materials labor etc. complete. |
| 95 | Fixing of antskid ceramic floor tiles floor tiles of size 30cmx30cm/40cmx40cm special plane/ printed series of premium grade having thivkness 7mm to 8mm confirmingto is 13753laid on 25mm thick bed of cement morter 1;1 and filling joint with whit cenent of approved quality in slurry mixedwith pigment to match the shades of the tiles including rubbing and polishing complete including cost of tiles with cost of all materials labour etc. complet. |
| 96 | Fixing Ceramic glazed tiles in wall on 12mm thick cement plaster (1:3) joined with neat cement slurry mixed with pigments to match the shade of the tiles including cost of ceramic wall tiles of approved shade with all cost including as per direction of Engineer-in-charge. |
| 97 | Fixing vetrified tiles in dados skiring and risers of steps on 12mm thick cement plaster (1:3) joined with neat cement slurry mixed with pigments to match the shade of the tiles including cost of ceramic wall tiles of approved shade with all cost including as per direction of Engineer-in-charge. |
| 98 | Earth work excavation in all kind of soil within intial lead of 50 m and initial lift of 1.5 m including rough dressing and leveling the bed…etc complete in all respect and as per the direction of Engineer-in -charge. |
| 99 | Supplying & filling in foundation and plinth with good quality river sand including watering , ramming with cost, conveyance, royalities , taxes of all materials and cost of all labour with T & P , Sundries required for the work etc., complete ( Measurement will be aken on finished compacted section) as per specification and direction of Engineer-in-charge. |
| 100 | C.C. (1:3:6) with 40Cm size HG crusher BROKEN Metal including all cost, conveyance , royalty & taxes etc com. To work size as per spcecification approved by the department & direction of E.I.C |
| 101 | Supplying and fixing of Pre cast kerb stone of size 600mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984. |
| 102 | Supply and laying M30 grade heavy duty factory made hydraucally pressed and mechanically compacted free cast inter looking paver block with sand binding and final compaction with plate vibrator finishing the surface including cutting the block with its edges and fixing kerbstone along both sede of the pathway all complete as per specification and direction of Engineer-in-charge. |
| 103 | Earth work in excavation of foundation trenches in all kids of soil including dressing and leavelling the bed upto the required depth and depositing the excaveted materials with all leads & lifts T&P Shoring and shuttering watering if necessary etc. complete as per directed by the Engineer-in-charge. |
| 104 | Supplying and filling foundation and plinth with sand watered and rammed including cost, conveyance, royalties and taxes of all materials and cost of all labour, T&P required for the work etc. complete (measurement will be taken on finished compacted section only) as directed by the Engineer-in Charge. |
| 105 | Cement concrete (1:3:6) using approved quality from approved quarry including lowering laying concrete watering and curing etc. as required levels laid in layers not exceeding(0'-6'') 15 cm thick including cost, conveyance,royalities and taxes of all materials and cost of all labour ,T&P required for the work etc. complete in all respect as directed by the Engineer-in-charge . |
| 106 | R.C.C. work M-25 in grade having a minimum compressive strength (in work test) 150 kg/cm2 in 15cm cubes at 28 days using 12mm. & down grade hard granite C.B. chips of approved quality and from approved quarry including watering, lowering laying concrete, compacting with vibrators, curing for 28 days with smooth etc complete.Col. Footing Base |
| 107 | Tie Beam |
| 108 | R.C.C. Columns |
| 109 | Supplying Cutting,bending un- coated HYSD bars,for reinforcement tying the grills and placing in position as required for the RCC works and for providing fan hooks hoisting and lowering,laying including cost,conveyance & taxes of SYSD bars and binding wires of 18 to 20 gauge required for the work and bending binding and tying the grills |
| 110 | Fly ash bricks masonary incm (1:6) after immersing the bricks 6 hrs. in water before use in Foundation and plinth having C.S. 75kg/cm2 in cluding all cost, carriage, royality etc. complete. |
| 111 | Fly ash bricks masonary in cm (1:6) after immersing the bricks 6 hrs. in water before use in super structure having C.S. 75kg/cm2 in cluding all cost, carriage, royality etc. complete. |
| 112 | 12 mm thick cement plaster in cm (1:4) with neat cement punning finished smooth after raking out the joints including watering, curing with cost, conveyence etc.complete. |
| 113 | 16 mm thick cement plaster in cm (1:6) over brick wall finished smooth after raking out the joints including watering, curing with cost, conveyence etc.complete.In Side Wall Surface |
| 114 | Providing & fixing barbed wire fencing and post by means of staples and straining hooks by means of tying with G.I. wire and including cost of staples, hooks and tying wires |
| 115 | Cost of Barbed wire |
| 116 | M.S. Grill gate made out of M.S. flat conforming to |S 2062/20006 painted with red oxide primer as pe the design approved. |
| 117 | Finishing wall surface with weather coat painting 2 coat over a coat of primer to the new surfaces of walls with all cost. |
| 118 | Painting 2-coats with any approved paint over one coat of primer on new wood or iron work including cost of materials. |
| 119 | SITE DEVELOPMENT AND LANDCAPING- Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. |
| 120 | Supply & Filling at all depth with available good filling Earth (excluding rock) in mechanical carriage of good garden soil etc. in the smart park area in layers not exceeding 15cm in depth consolidating each deposited layer by ramming and watering complete ( lead upto 100m) as directed by Enginner-In-Charge. |
| 121 | Compacting and watering upto OMC rolling earth work with P.R.R. in embankment in layers not exceeding 0.23m by power road roller including hire and running charges of the roller (measurement to be taken on the finished compacted section of the fill under O.M.C. condition) (See Page no-06,Item no 9 of AoR-06) |
| 122 | Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge. (standard data book_DSR_2020_Horticulture code.no.2.33 page 91) |
| 123 | Supplying and stacking of sludge at site (standard data book_DSR_2020_Horticulture code.no.2.30 page 83) etc. complete as per directed by the Engineer-in-charge. |
| 124 | Spreading of sludge , dump manure in require thickness (standard data book_DSR_2020_Horticulture code.no.2.4.3. page 83) etc. complete as per directed by the Engineer-in-charge. |
| 125 | Plantation of Trees , Shurbs and Hedge at site i/c watering and removal of unservicable materials as per direction of officer in Charge.(Rate as per DSR-2020 Horticulture , Page no.259 Sl.no. 2.57)) as directed by the Engineer-in Charge. |
| 126 | DRAIN AND C.C. PAVEMENT- Earth work in excavation in ordinary soil within 50mt. initial lead and 1.5mt initial lift including rough dressing and breaking clods to 5 cm. to 7 cm. size laying in layers not more than 30 cm.in depth as per MoRT&H Specifications etc complete. |
| 127 | Filling foundation and plinth with sand well watered and rammed including cost conveyance royalty of sand and labour etc complete. |
| 128 | P.C.C. (1:3:6) as per drawing & technical specification including cost of all materials labour T&P etc complete. |
| 129 | R.C.C. work of M-25 Grade as per drawing & technical specification including cost of all materials labour T&P etc complete. |
| 130 | Supplying fitting and placing uncoated HYSD bar in skin reinforcement complete as per drawing and technical specification etc. complete. |
| 131 | BOREWELL-Labour for drilling a perfectly verfical bore holes of specified deameter for a specified depth below groud level through hard and boulder formation by means for fast Drilling sophisticted Rigs as required a suit the site condition as per the direction of Engineer-in-charge including deployment of Rig with its accesories , T & P and consumable etc for a finished bore suitable for lowering of 125% 100 mm nominal dia PVC or GI casing pipes fitted with socket and with or without well screen as per necessity for the soft and hard formations drilled by combination drilling method. |
| 132 | Labour for lowering the following sizes of PVC or GI pipes with or without strainers as per necessity and fitted and fixed up in perfectly vertical position including cutting and threading the pipes as may be necessary and supplying all jointing materials , extra sockets ( Gi or PVC heavy quality), tools and plant etc complete and keeping top of the casing pipe threaded including plugging the tube wells to prevent entry of foreign materials form above. |
| 133 | Labour for lowering the following sizes of PVC or GI pipes with or without strainers as per necessity and fitted and fixed up in perfectly vertical position including cutting and threading the pipes as may be necessary and supplying all jointing materials , extra sockets ( Gi or PVC heavy quality), tools and plant etc complete and keeping top of the casing pipe threaded including plugging the tube wells to prevent entry of foreign materials form above. |
| 134 | Withdrawing casing pipes |
| 135 | Supplying all materials , labour and T & P for providing sanitary sealing by cement concrete grouting of annular space around GI /PVC/MS housing pipe up to 5 mtr below ground level to plug the borehole including cost of cement etc all complete as per direction of EIC |
| 136 | Submersible / Centrifugal pumpsets without Conrol panel |
| 137 | Star Delta Control pannel wih APFC arrangement |
| 138 | For 03 nos Borewell |
| 139 | CIRCUIT CUM WIRING- Supplying & Wiring for light point/ fan/ exhaust fan point/ call bell point with 1.5 sqmm FR PVC insulated copper conductor single core cable in surface / recessed 2 mm thick PVC conduit with modular switch and earthing the point with 1.5 sqmm FRLSH PVC insulated copper conductor single core cable including providing modular box with cover of requisite number of modules including providing cover plates as required. Single light point controlled by one 6A switch or first light point of group control. |
| 140 | Subsequent point of group control |
| 141 | Supplying and fixing two module steeped type electronic fan regulator with proper modular plate switch box including connections etc. as required. |
| 142 | Supplying and fixing 6 Amp plug with 6 Amp switch (Modular Type) on existing switch board. |
| 143 | Supplying & fixing of suitable size GI Box with modular plate and cover in front on surface or in recess, including providing and fixing 3pin 5/6 amps modular socket outlet and 5/6 amps modular switch etc. as required. |
| 144 | Supply, installation, testing & commissioning of 6 / 16 Amp Plug Boards consisting of a 16 Amp clip-in type modular switch with indicator and a 6/16 Amp clip-in type modular shuttered plug socket fixed on metallic concealed box including interconnections and making good the damages caused complete as required and as per direction of Engineer-in-charge. |
| 145 | Supplying, installation, testing & commissioning of 20 Amp AC starter switch with 20 Amp modular socket outlet with 25 Amp Plug on surface or in recess, on 2 Nos two module GI box with plate etc. complete with direction of Engineer-in-charge. Starter-Crabtree(cat no-ACTO202504) or equivalent. |
| 146 | Wiring for circuit/ submain wiring along with earth wire of following size of FRLSH heavy gauge PVC insulated copper conductor single core cable in heavy duty PVC conduit laid in surface/ recess as required. 2X2.5 + 1X2.5 sqmm FRLS Cu wire |
| 147 | 2X4 + 1X2.5 sqmm FRLS Cu wire |
| 148 | 2X6 + 1X2.5 sqmm FRLS Cu wire |
| 149 | 4X6 + 2X2.5 sqmm FRLS Cu wire |
| 150 | 4X10 + 2X4 sqmm FRLS Cu wire |
| 151 | Fan & indoor Fixtures-Supply, delivery and fixing of Ceiling fan hook box made out of 18 swg GI sheet and containing 10 mm dia round ms bar projecting atleast 150mm on either side & duly bent to accommodate ceiling fan down rod bolt & having earthing arrangement as per direction of Engineer-in-charge. |
| 152 | Supplying, installation, testing and commissioning following type of light fixture with all other accessories, as required.(The colour temprature shall be between 5000 deg K as per application).-Fully diffused type Recessed mounted round type LED fitting (1800 Lumen/ 18W) similar to Wipro (CAT No:LD06-221-XXX-57-RF*)/ Equivalent of Philips/ LT. |
| 153 | Commercial Batten type wall or surface mounted 4' LED fitting (2000 Lumen/ 20W) similar to Wipro (CAT No:LL24R-251-XX-57-2F) / / Equivalent of Philips/ LT. |
| 154 | Wall mounted LED Bulk head fitting (10W) similar to Wipro (CAT No:LW07-141-XXX-57-G1)/ Equivalent of Philips/ LT. |
| 155 | Wall mounted LED Highbay fittings (80W) with other accessories similar to Wipro (CAT No:LH21-102-060-57-X2)/ Equivalent of Philips/ LT. |
| 156 | Supplying, Erection, Fixing, connection & testing of LED BOUNDRY WALL Light of elegant look (Make: LT/Philips/Wipro) 60 W LED street light having die cast aluminium housing with toughened glass having lumen efficacy of 110 lm/w or more (As per LM 79 report of third party NABL lab) ,IP 65 protection or more , LED street light model having warrantied for a period of 5 years . The luminaire should be supplied along with bracket maintenance free for inspection as required as per direction of Engg.-in-Charge. |
| 157 | Supplying, installation, testing and commissioning of ceiling fan (5 star rating) including wiring the down rod, earthing etc as required (Make : Bajaj/Usha/ Crompton/ Orient/ Khaitan/ Havells).1200 mm sweep |
| 158 | Supplying, installation, testing and commissioning of wall mounted fan (5 star rating) including earthing etc as required (Make : Bajaj/Usha/ Crompton/ Orient/ Khaitan/ Havells).400 mm sweep 1300 RPM |
| 159 | Supplying, installation, testing and commissioning of Heavy Duty Exhaust fan (5 star rating) including louvres, Ceiling Rose & Electric Connection as required. (Make -Bajaj/Usha/ Crompton/ Orient/ Khaitan/ Havells) 300mm sweep 900 RPM |
| 160 | Main Distribution PanelS/I/T&Commissioning of LT INDOOR Wall/floor mounted cubical type electrical panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 years & compelete test certificate must be submitted along with panel board including component list.3P+N Type 2 40 kA SPD with 63A rating,10KA breaking capacity ,4P MCB shall be installed in the incomer.25x10mm Separate Aluminium Earth bus bar should be installed.All the incoming and outgoing feeders shall have ON/OFF/TRIP indication.PANEL AS ABOVE |
| 161 | Cow Shed PanelS/I/T&Commissioning of LT INDOOR Wall/floor mounted cubical type electrical panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 years & compelete test certificate must be submitted along with panel board including component list.3P+N Type 2 40 kA SPD with 63A rating,10KA breaking capacity ,4P MCB shall be installed in the incomer.25x10mm Separate Aluminium Earth bus bar should be installed.All the incoming and outgoing feeders shall have ON/OFF/TRIP indication.PANEL AS ABOVE |
| 162 | DBs-Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). (For all Floor DBs) 6 way Single metal door |
| 163 | Supplying and fixing following rating MCBs/ Isolator/RCCB in the existing MCB DB complete with connections,testing and commissioning etc. as required.63 Amps, TPN 10 KA MCB (C-Curve) |
| 164 | 25 Amp to 32 Amps, TPN 10 KA MCB (C-Curve) |
| 165 | 6 Amp to 32 Amp, 10 KA SP MCB (C-Curve) |
| 166 | Conduits-Supply, delivery and laying of following sizes of medium class PVC Conduit concealed in wall/ column/ roof slab of the building alongwith other accessories and 18 swg GI wire complete for Electrical Wiring/Telephone / TV & Data cable wiring as required other accessories as per direction of Engineer-in-charge.20mm dia |
| 167 | 25mm dia |
| 168 | Earthing System-Supply of materials and installation of pipe earth electrode made out of 40mm dia class B G.I. pipe of 4.5 metre long with arrangements for fitting/ termination of G.I. flat / wire with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 169 | Providing and fixing of 8 swg GI Wire on surface or on recess as required. |
| 170 | Providing and fixing 25 mm X 5 mm dia G.I strip on wall/surface With required DMC insulator and nut bolt connection etc. as required. |
| 171 | Cables, Cable Laying & TerminationSupply of XLPE insulated PVC sheathed aluminium conductor 1.1 KV grade steel armoured UG cable confirming to IS 7908 (Part-I) as amanded up to date of following sizes 3.5core x 95 sq mm |
| 172 | 3.5core x 50 sq mm |
| 173 | 3.5 core x 25 sqmm |
| 174 | 4 core x 10 sqmm |
| 175 | 4 core x 6 sqmm |
| 176 | 3 core x 4 sqmm |
| 177 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of following size direct in ground including excavation (75 cm),sand cushioning,protective covering and refilling the trench etc as requiredUpto 25 sq. mm |
| 178 | Above 25 sq. mm and upto 120 sq. mm |
| 179 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 25 sq. mm (clamped with 1mm thick saddle) |
| 180 | Above 25 sq. mm and upto 400 sq. mm |
| 181 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3.5core x 95 sq mm |
| 182 | 3.5core x 50 sq mm |
| 183 | 3.5 core x 25 sqmm |
| 184 | 4 core x 10 sqmm |
| 185 | 4 core x 6 sqmm |
| 186 | External Lighting & other Accessories:Supplying, Erection, Fixing, connection & testing of 40W LED GATE Light of (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) maintenance free having 2 years warranty G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. |
| 187 | Street Lights: Supply, erection, testing & commissioning of road lighting HDG Octagonal Pole conforming to IS 875 and BS EN ISO 1461 & 410 SP 33 of 7.0 meter with base plate drilling of 1\\" dia hole on the upper portion of the pole for the installtion of street light and 1\\" dia hole on the lower portion of the pole for entry of the wire Base pole paintng of red oxide and two coats of black enamel paint. The poles shall have extra provided and fixed with 4'x2' dia being erected by laying 5'x2'x2' (length, breadth and width) cement concrete block in the ratio 1:3:6 and block be continued up to 1 feet above the ground level i.e 4 feet below ground level including surface plastering the job including excavation of pole with 4 feet deep and refilling the same after installation of the pole and with holes at top of the pole for fixing ring type single armed GI braket for the installation of the integral flood light luminaire of 80 watt. The Dust and wheather proof gasket using for 250mmx200mmx150mm deep box nominal size of 16 SWG thick MS sheet cable looping box with the existing pole with MS clamp made out of 25mmx3mm thick flat iron with suitable nuts and bolts complete with hinged cover and locking screws earth studs neoprene gasket suitable for Nos 4 pole mounted including supply and fixing one no 6 Amp MCB carrier with base and 4 way 60 Amp terminal block suitable to receive PVC armoured cable fixed on suitable size Baketillte sheet base complete connection through GI pipe (classB) 40 mm dia Nominal 1.5 mtr length along the pole or protection of underground cable (on vertical run) with painting all complete as the direction of EIC(Wind speed 250Km/hr shall be considered) . Similar to Wipro, Signify (Philips only), LT.Single Arm Street Lights |
| 188 | MinimastSupply, installation, testing & Commissioning of 9.0 M mini housing made up of pressure die cast aluminum Alloy with effective thermal management,sturdiness and embossed brand name/logo name of manufacturer Octagonal mast shaft in single section (Bottom: 310 mm, top: 150 mm, 3 mm thickness, Base Plate Dia: 520mm X 16 mm, PCD: 440MM) suitable for 50 m/sec wind speed along with head frame, luminaires carriage suitable for 06 luminaires in symmetrical arrangement and other accessories manufactured in factory having provisioning of raising lowering system comprising double drum winch, 5mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightning finial. Including Wiring material from JB to individual luminaire & MCB in base compartment. Supply & fixing of foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template with holes at top of the pole for fixing ring type four armed GI braket for the installation of the integral flood light luminaire of 6X200 watt (Make : Wipro Cat no: LF40-272-060-57-HE or equivalent of PHILIPS/LT). The Dust and wheather proof gasket using for 250mmx200mmx150mm deep box nominal size of 16 SWG thick MS sheet cable looping box with the existing pole with MS clamp made out of 25mmx3mm thick flat iron with suitable nuts and bolts complete with hinged cover and locking screws earth studs neoprene gasket suitable for Nos 4 pole mounted including supply and fixing 16A TPN MCB incomer, single dial time switch, 16A TP contactor for the automatic switching of luminaries, power tool control with 2 no 9A contactors with painting all complete as the direction of EIC. |
| 189 | Feeder Pillar for External LightsSupplying installation testing commissioning if double door feeder pillar fabricated out of 3 mm thick CRCA sheet duly painted, 100 Amp Al busbar with neutral bus bar including cc/ brick foundation, Ameter, CT , Voltmeter, Rain Canopy as required including following internal fixtures.1 No - 16 Amp SP MCB with 6/16 Amp socket outlet with 10 Amp modular switch and 1 No- Bracket Holder with 6 Amp Modular switch. |
| 190 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. 150 mm dia |
| 191 | Lightning Protection System:Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 192 | Supply of Roof conductor holder for parapet- PolyamideConductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested.Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 193 | Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black@ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 194 | Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/ABB |
| 195 | Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 196 | Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 197 | Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/Dehn/ABB |
| 198 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn/ABB |
| 199 | Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified indrawing and directed by Engineer.Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 200 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr HeightFor Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB |
| 201 | Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 202 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 203 | Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 204 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB |
| 205 | Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn/ABB |
| 206 | Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn/ABB |
| 207 | Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB |
| 208 | Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Make-OBO/Dehn/ABB |
| 209 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. |
| 210 | Split AC with AccessoriesSupply,installation, testing and commissioning of Air Cooled HI Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), i/c R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut off and50 hz ,1 phase AC Supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS/ International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS :1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). The indoor outdoor must be Blue Fin coated. The unit price included with 3mtr Copper piping with insulation, drain Pipe and copper Power cable. The indoor should have 4 way swing . In case, the distance between ODU and IDU exceeds 3 mtr, then only the item of copper pipe shall be executed without any joint and equivalent mtr shall be deducted from the copper pipe item.1.5 TR with 5 Star BEE Rating (LG-AS-Q20JWZE/ O General-ASGG18CGWA-B/ Daikin-FTKU50XV16) |
| 211 | Supply,installation of hard/soft ISI marked copper refrigerant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25 mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job. |
| 212 | Supply,installation & fabrication of MS base frame for outdoor unit and other nesessary material to complete the job. |
| 213 | Extinguishers:Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS : 2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/ Fireshield/Kanex/ Ceasefire/Flameklog .4.5 kg capacity |
| 214 | Providing and fixing ABC type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/ Fireshield/Kanex/ Ceasefire.6 kg capacity |
| 215 | Supplying, installation, testing and commissioning of 2 kg capacity Eco friendly stored pressure type filled with HFC 236(Clean agent fire extinguisher) having zero ozone depletion potential clean agent fire extinguisher with safety seal, pressure gauge,controlable discharge mechanism helium leak detection tested and confirming to IS 15683 complete with initial charge including cost of all material & labour etc complete. Make-Safex/Fireshield/Ceasefire/Flameklog/Kanex |
| 216 | Internal and External PH and Sanitary fitting |
| 217 | MiscellaneousSupply & fixing of Safety Equipment 415KV Rubber Mat(1M x 2M x 2.0MM) |
| 218 | Shock Treatment Chart & SLD |
| 219 | Safety Gloves Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysAug 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender