Tender For Construction Of A New Separate Entry Gate To The Administrative Block At Prtc Head Office, Nabha Road, Patiala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
11 Aug 2026
14 days left
EMD
29500
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Patiala → Punjab
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of A New Separate Entry Gate To The Administrative Block At Prtc Head Office, Nabha Road, Patiala
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling concrete Reinforced cement concrete complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 8.6 e) |
| 2 | Dismantling of Flexible Pavements (By Mechanical Means) Dismantling of flexible pavements thickness above 50mm by mechanical means and disposal of dismantled materials up to a lead of 1000 meters, stacking serviceable and unserviceable materials separately as per technical clause 202 of MORT&H specifications complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 24.3 a) |
| 3 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 6.6) |
| 4 | Cement concrete 1:4:8 mixing by mechanical means using concrete mixer volumetric type complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 10.10 a ii) |
| 5 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 11.5) |
| 6 | First class burnt brick work laid in cement sand mortar 1:3 in first storey upto 4 metres above plinth level complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 11.10) |
| 7 | Reinforced cement concrete M-40 mechanically batch mixed using batch mixed using concrete mixer and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 10.24) |
| 8 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 18.18) |
| 9 | Black Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 14.87) |
| 10 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 14.88) |
| 11 | Providing and laying 80 mm thick factory made cement concrete interlocking Paving blocks of M-40 grade manufactured by block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63 -2014 and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 14.139) |
| 12 | Earth filling Earth filling under floors with surplus soil containing more than 40% gravel or kankar excavated from foundation & taken only from outside the building plinth in 15 cm layers including ramming watering and consolidation lead upto 30 metres complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 6.8 a i) |
| 13 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 18.4) |
| 14 | Extra Carriage of Material for Fine Sand |
| 15 | Extra Carriage of Material for Coarse Sand |
| 16 | Extra Carriage of Material for Aggregate |
| 17 | Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 2.5 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge {CSR 13.74} |
| 18 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. {CSR 13.75 c} |
| 19 | Construction of Yard Room with Modern amenities Size: 14.50 x 14.50 = 210.25 Sft Dismantling brick work tile, masonry or tile lining n cement complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 8.5 b) |
| 20 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 6.6) |
| 21 | Cement concrete 1:5:10 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 10.9 b ii) |
| 22 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 11.5) |
| 23 | First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 11.6) |
| 24 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 10.15) |
| 25 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge and 100 mm fine sand filling using mechanical mixer for mixing of material complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 14.3) |
| 26 | 20mm thick cement plaster 1:4 in two coat work complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 15.20) |
| 27 | 12.5 mm thick cement plaster 1:4 complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 15.9) 20mm C.P. B/F = 2350 Sft |
| 28 | Tile terracing laid dry over roof consisitng of one layer of tiles 22.86x11.43x3.83 including grouting with cement sand mortar 1:4 top surface to be left clean after wire brushing complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 13.17) |
| 29 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 13.45) |
| 30 | For fixed portion and chawkhats complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 17.45 a) |
| 31 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 17.45 b) |
| 32 | Cement pointing 1:2 flush on flat brick flooring complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 15.67) |
| 33 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 13.55) |
| 34 | Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 2.5 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 13.74) |
| 35 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend (CSR 13.75 a) |
| 36 | Earth filling under floors with surplus soil containing more than 40% taking outside the premises in 15 cm layers including ramming watering and consolidated lead upto 1000 metres complete as per PWD specification to the entire satisfaction of E.I.C. Base course area B/F = 74X0.30 = 22.00 Cum (CSR 6.8 c ii) |
| 37 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Pre- laminated particle board with decorative lamination on one side complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 17.46 i) |
| 38 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item) Float glass panes of 5 mm thickness (CSR 17.47 i) |
| 39 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete as per PWD specification to the entire satisfaction of E.I.C. R.C.C. 9.94 Cum @ 110Kg/Cum or 10.94 Qtl (CSR 18.18) |
| 40 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 9.8) |
| 41 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) one coat over one priming coat on old distempered surface complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 16.11) |
| 42 | Preparation of plastered surfaces for distempering including surface, applying filling with approved quality filler consisting of plaster of paris and chalk mitti including finishing the surface to the required finish complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 16.6) |
| 43 | Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm complete as per PWD specification to the entire satisfaction of E.I.C. (CSR 16.60) |
| 44 | Wiring fan point (Without fan box) {CSR 34.07 (A) (i) (a)} |
| 45 | Wiring light point {CSR 34.07 (A) (ii} |
| 46 | Wiring 6Amp. wall socket point {CSR 34.07 (A) (iv)} |
| 47 | Wiring 6Amp. Plug control comprising wall socket point {CSR 34.07 (A) (v)} |
| 48 | Wiring 16/20Amp. power plug control point {CSR 34.07 (A) (iv)} |
| 49 | Overall size 1.5sq.mm (Un-sheathed) {CSR 34.1 (ii)} |
| 50 | Overall size 2.5sq.mm (Un-sheathed) {CSR 34.1 (iii)} |
| 51 | Overall size 4sq.mm (Un-sheathed) {CSR 34.1 (iv)} |
| 52 | Overall size 6sq.mm (Un-sheathed) {CSR 34.1 (iv)} |
| 53 | MCB Single Pole 6-32amp. (10kA, Curve-C) {CSR 34.16 a (ii)} |
| 54 | MCB Double Pole 40amp. (10kA, Curve-C) {CSR 34.16 a (vii)} |
| 55 | MCB Four Pole 40amp. (10kA, Curve-C) {CSR 34.16 a (xv)} |
| 56 | MCB Four Pole 50, 63amp. (10kA, Curve-C) {CSR 34.16 a (xvi)} |
| 57 | Supply and Erection of Ceiling Fans 1200 mm Sweep (48\\") 3-Star having two ball bearing including flexible wire & petty material etc. complete in all respects as appd. and desired by the Engineer in-charge at site. |
| 58 | Supply and erection of LED batten 40watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP 20 (as per BIS standards) , surge protection 2.5kv and above (as per (IS/IEC standards) wattage of each low powers LED less than 1 watt input AC frequency 50 Hz ± 3 % 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the lighting fixture manufactures should have in house NABL accredited labortary. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysAug 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender