Tender For repair maintenance Various Electrical Installations And Mechanical Equipments At Dtte/Bte At Pit Ura, Delhi During 2026-27.
Tender Value
30.08 Lakhs
Estimated cost
Bid Submission
28 Jul 2026
1 days left
EMD
60167
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for repair maintenance Various Electrical Installations And Mechanical Equipments At Dtte/Bte At Pit Ura, Delhi During 2026-27.
BOQ
| Sl. No. | Item Description |
| 1 | SH-I:- Maintenance of EI & fans (Manpower)Providing day to day maintenance of EI & fans comprising of light point, fan point , call bell point, power point ,submain wiring ,fans, fittings, DBs and Panel i/c all electrical works , security lights, pole light etc on all working days Excluding Sunday and Holidays as per terms and condition attached and timing as per direction of Engineer -in- charge & wherever reqd. at following locations :1. DTTE Building, Pitampura2. BTE Building , PitampuraTotal Staff Required :- Wireman - 01 Nos. (1 No. in General shift )Khallasi - 01 Nos. (1 No. in General shift) |
| 2 | SH : II - Operation of DG SetRunning maintenance and operation and general upkeep of 1 nos. 160 KVA capacity DG sets along with auto start panels and RO Plant & carrying out the daily drill comprising of cleaning of DG sets and maintaining log book for above installation Total Staff Required:-(i) DG set operator cum pump set operator cum RO Plant operator - 1 Nos. (1 in General shift) |
| 3 | SH : III - Operation of LiftProviding Service for operation & upkeeping of 1 no. Johnson Make , 8 passenger lift installed at DTTE building ,Pitampura in general shift on all days of the month excluding Saturdays , Sundays and Holidays complete by deputing following well experienced lift operator including cleaning and up keeping of lift car and lift machine room complete as per terms and conditions attached :Total staff required:-Skilled Lift Operator cum RO Plant operator - 01 No. ( 8:30 AM to 6:00 PM) |
| 4 | SH-IV (Material)Supplying of following electrical accessories for day maintenance in the existing electrical installation etc. as reqd :-a) SP 5/6 A, one way modular switch, ISI marked |
| 5 | b) SP 15/16 A, one way modular switch, ISI marked |
| 6 | c) 3 pin 5/6 A modular socket outlet, ISI marked |
| 7 | d) 6 pin 15/16 A modular socket outlet, ISI marked |
| 8 | e) 25A Modulare SPMCB 'C' Curve |
| 9 | f) 6A, to 32 A, ratings, SP MCB, \\"C\\" Curve, 10 KA Breaking Capacity |
| 10 | g) 6A, to 32 A, ratings, DP MCB, \\"C\\" Curve, 10 KA Breaking Capacity |
| 11 | h) Call bell/ buzzer, single phase |
| 12 | i) Modular bell push, ISI marked |
| 13 | j) two module stepped fan regulator |
| 14 | k) 100 Amp, 16 KA, TPMCCB |
| 15 | l) 125 Amp, 16 KA, TPMCCB |
| 16 | m) 1.5 sq. mm ISI marked, FRLS/HFFR PVC insulated, single core copper conductor cable |
| 17 | n) 4.0 sq. mm ISI marked, FRLS/HFFR PVC insulated, single core copper conductor cable |
| 18 | o) LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) of following body materials. Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflectori) 30 watt |
| 19 | p) LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) of following body materials. Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)i) 40 watt |
| 20 | q) LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) of following body materials. Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)i) 36 watt |
| 21 | r) LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) of following body materials.i) 120 watt |
| 22 | s) LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy 105 <120 lm/Watt) of following body materials.i) 150 watt |
| 23 | t) ceiling fan with Brush Less Direct Current (BLDC) Motor, etc. complete as reqi) 1200mm, BEE 5 star rating, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 24 | u) Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm |
| 25 | v) 40 Amp DPMCB 10 kA breaking capacity |
| 26 | w) 63 Amp DPMCB 10 kA breaking capacity |
| 27 | x) 63 Amp TPN MCB 10 kA breaking capacity |
| 28 | y) 300 mm 1400 RPM heavy duty exhaust fan ISI Mark |
| 29 | z) Supplying & replacement of 2.5 MFD capacitor |
| 30 | aa) 400 mm sweep wall fan |
| 31 | SH-V (Minor EI & Pumpset Repair Work)Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. a) Group C |
| 32 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, multi core cable in then existing surface/ recessed steel/ PVC conduit/channel as required. a) 3 core 1.5 sq. mm |
| 33 | b) 3 core 4 sq. mm |
| 34 | c) 3 core 6 sq. mm |
| 35 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm |
| 36 | b) 25 mm |
| 37 | Providing and fixing of PVC Trunking of following sizes complete with flexible cover, joint, endcap, cover on surface of wall/existing mounting etc. as required. a) 32 mm x 20 mm |
| 38 | Supplying, Laying and fixing of one number following size PVC insulated flexible Copper cable in existing PVC channel / Conduit /false ceiling complete with connection etc. as required at site.a) 3 core X 4 sq. mm size |
| 39 | b) 3 core X 6 sq. mm size |
| 40 | Rewinding of following size Submersible/Mono submersible/monoblock pumpset i/c dismantling of pumpset from site, cartage from site to work shop and return back, cutting the burnt winding wire (credit for old winding wire) & rewinding the same with PVC insulated copper winding wire etc. as reqd.a) 5 HP |
| 41 | b) 7.5 H.P. |
| 42 | Lowering of upto 3/5/7.5/10/20 HP Mono Submersible/Sewage/ Submersible P/set along with G.I. pipe in existing well/underground tank with the help of chain pulley and tripod etc. as reqd. |
| 43 | Taking out of upto 3/5/7.5/10/20 HP Mono Submersible/Sewage/ Submersible P/set along with G.I. pipe in existing well/underground tank with the help of chain pulley block and tripod complete as reqd. |
| 44 | Supplying & fixing 3 x 4 sq.mm. submersible flat cable copper conductor cable of grade 1.1 KV including connection, testing etc. as reqd. |
| 45 | Dismantling existing fire extinguishers and refilling of following capacity and type from installed position removing old gas/other extinguishing material from from cylinder hydraulic pressure testing taking to workshop, refilling of gas/catridge/other extinguishing material, pasting of stickers, bring back to site and reinstallation etc as required.a) ABC powder type fire extinguisher 6 kg capacity |
| 46 | b) Co2 gas type fire extinguisher 4.5 kg capacity |
| 47 | SH :- VI (Air Conditioning/Water Coolers )Comprehensive routine maintenance of Window / Split type ACs units of 1.0 / 1.5 / 2.0 TR capacity units of different makes installed at various locations as per inventory attached, i/c repairing / replacement of remote, capacitor running type, all types of defective parts,gun metal taps, electronic parts ,float valve assembly excluding topping up of refrigerant in compressor, refrigeration pipe, PCB for indoor/outdoor complete as per terms and conditions, and timing as per direction of Engineer -in- charge & wherever reqd. (Note:- i) During the period of Summer Season & duration as specified by the Engineer-in-Charge ii) Maintaining of Complaints will be recorded by the agency in the AC Task/Complaint register) 80 Units/Month X 8 Months = 640 Units |
| 48 | Complete servicing of WTAC/STAC/unit of 1/1.5 / 2.0 TR capacity including dismantling the AC from its existing position at various locations/grill/window cutting, washing with High pressure water spray electric machine coil cleaning with D- Scaling Chemical, drying with air blower ,oiling, greasing, of blower fans cleaning of evaporative and condensing coil with suitable chemical like coil cleaner, as required in its existing position complete as per direction of Engineer -in- charge & wherever reqd. |
| 49 | Replacement of printed circuit assembly (PCB) of the Existing indoor Unit Split/WTAC AC 1.5/2.0 TR Complete with connection & Testing etc. as required at side in the machine as per requirement & approval of the Engineer-in-Charge. (Dismantled material shall be retained by the contractor) |
| 50 | Replacement of printed circuit assembly (PCB) of the Existing Outdoor Unit Split AC/WTAC 1.5/2.0 TR with connection & Testing etc. as required at side in the machine as per requirement & approval of the Engineer-in-Charge. (Dismantled material shall be retained by the contractor) |
| 51 | Repairing of PCB card of 1.5/2 TR capacity WTAC/split type AC unit having following capacity after dismantaling the defective card from AC unit & refixing the same i/c connections of electrical wires/cables & thimbles connection, testing & commissioning etc. complete as required. |
| 52 | Supplying & charging of Refrigerant gas (R-22/32/refrigerant suitable as per requirement of AC unit) in the following type capacity AC units i/c leakage testing removing the leakage, pressure testing, flushing the complete system, vacuumising and gas charging complete as required. (Cost for gas & labour charges already included in the below mentioned item) (Note:- Quantity of gas filled shall be entered in Consumption Register maintained by the agency) a) In 1.5 TR WTAC/STAC capacity |
| 53 | b) In 2.0 TR WTAC/STAC capacity |
| 54 | Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :a) 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 55 | b) 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 56 | c) 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 57 | d) 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm |
| 58 | Supplying of following accessories for the existing 1.5 TR/ 2 TR. capacity WTAC / STAC unit, using existing man power for replacement on day to day maintenance work: a) 15 Amp 3 Pin plug Top (ISI Marked) |
| 59 | b) 3 core PVC insulated PVC sheathed copper wire 2.5 Sq.mm copper flexible |
| 60 | c) 50/4.0 Mfd Rating Starting/Running Capacitor |
| 61 | d) 36/6.0, 40/2.5 Mfd Rating Starting/Running Capacitor |
| 62 | Dismantling & Re-installation of existing suitable 1.5 TR/2.0 TR capacity WTAC unit etc. with equipments complete as reqd. |
| 63 | Dismantling & Re-Installation of STAC Unit existing suitable 1.5 TR/2.0 TR capacity STAC unit( both indoor & outdoor) with copper pipe, Drain Pipe, Stablizer, Topping up of gas etc complete as reqd & direction by Engineer in charge. |
| 64 | Supplying and replacement of following parts including removal of un-serviceable part, electrical connections & re-installation the same, testing, commissioning etc. as required. (Labour & gas charges already included in below mentioned item.)a) Rotary Compressor 1.5 Ton including less for old credit |
| 65 | b) Rotary Compressor 2 Ton including less for old credit |
| 66 | c) Reciprocating compressor 1.5 Ton including less for old credit |
| 67 | d) Reciprocating compressor 2.0 Ton including less for old credit |
| 68 | e) Outdoor fan motor 1.5 Ton including less for old credit |
| 69 | f) Out door fan motor 2 Ton including less for old credit |
| 70 | g) Indoor fan motor 1.5 Ton including less for old credit |
| 71 | i) Cooling coil copper - 1.5 Ton for WTAC/STAC including less for old credit |
| 72 | j) Condenser coil copper- 1.5/2.00 ton for WTAC/STAC including less for old credit |
| 73 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayJul 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender