Tender For repair maintenance E & M Services At New Delhi District Court Complex At Rouse Avenue Ddu Marg, New Delhi. (Sh: Operation Of Centralized Air Conditioning System And Miscellaneous Work).
Tender Value
16.25 Lakhs
Estimated cost
Bid Submission
29 Jul 2026
5 days left
EMD
32516
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for repair maintenance E & M Services At New Delhi District Court Complex At Rouse Avenue Ddu Marg, New Delhi. (Sh: Operation Of Centralized Air Conditioning System And Miscellaneous Work).
BOQ
| Sl. No. | Item Description |
| 1 | Running operation of 4x550 TR capacity centrifugal type HVAC plant along with associated accessories, different size AHU's CSAHU's , LT panels, cooling towers, condensers pumps, Primary & secondary pumps, Hot water generators etc including cleaning as per scope of work and terms and conditions attached on all days except Sunday & holidays .i) AC Operator - 04 Nos.ii) Khallasi :- 04 Nos. |
| 2 | Running operation of 4x550 TR capacity centrifugal type HVAC plant along with associated accessories, different size AHU's CSAHU's , LT panels, cooling towers, condensers pumps, Primary & secondary pumps, Hot water generators etc including cleaning as per scope of work and terms and conditions attached on Sunday & holidays as per requirement at site . i) AC Operator :- 02 Nos.ii) Khallasi :- 01 No. |
| 3 | Supplying and Charging of Refrigerant Gas R-22/R-32/R-410A gas in the split/window type air conditioning unit including ressure testing , leak detection, vocalisation, replacement of filter and capillary testing and commissioning etc complete as required. |
| 4 | 1.5 TR AC |
| 5 | 2 TR AC |
| 6 | Supply & Replacement of following Capacity Compressor of same type from existing WTAC/STAC units including dismantling of the existing burnt out/Defective Compressor with connection, interconnection of compressor with suitable size of suction and discharge copper pipe, Copper Strainer, capillary, nut-bolts and electrical wiring with leakage and pressure testing with nitrogen gas for 24-Hrs, Vacuumizing and Charging with suitable same type refrigerant R-22/R-32/R-410A ete Complete as required i/e credit for old dismantle material under buy back. |
| 7 | 1.5 TR AC |
| 8 | 2 TR AC |
| 9 | Replacement of following material of running capacitor for WTAC/ Split units and when as reqd. i/c credit of old dismantle material as and where basis etc. Running Capacitor |
| 10 | 2.5 MFD |
| 11 | 6 MFD |
| 12 | 36 MFD |
| 13 | 45 MFD |
| 14 | 50 MFD |
| 15 | Pdg. Services for maintenance/attending complaints and cleaning work of split/window type AC unit and water chilled cassette AC unit, installed at various location at Rouse Avenue District Court Complex in general shift i.e. 9 AM to 5 PM by providing following staffs on all days of the month excluding Sundays and Gazetted Holidays complete etc. as required.) (a) AC Mechanic – 1 No. (9:00 AM to 5:00 PM) (b) Khallasi 1 No. (9:00 AM to 5:00 PM) |
| 16 | Supplying and replacement of following capacity single phase motors in the existing window / split type AC units of 1.5 TR / 2.0 TR capacity & water coolers, after dismantling of existing defective / burntout motor i/c testing commissioning etc as required. i/c credit for old dismantle material under buy back. |
| 17 | Fan Motor for Window / Split type AC Units |
| 18 | Condenser fan blade |
| 19 | Supplying & replacement of programme logic controller (PCB) in the following type AC units of different makes complete with removing of existing defective PCB after disconnection connection from indoor / outdoor units checking of control cables and replace if required i/c removing & refixing of indoor & outdoor cover after fixing of new PCB, checking of both units for proper function of AC unit etc complete as required i/c credit for old dismantle material under buy back. |
| 20 | 1.5 /2 TR Window AC unit |
| 21 | 1.5/ 2 Tr Split type AC unit |
| 22 | Supplying & replacement of condenser coil in the following type AC units of different makes complete with providing & soldering of copper piping capillary tube / pipes (wherever required), pressure testing, vaccumization, trace out of leakage in indoor & outdoor unit, leakage testing, rectification of leakage, cleaning of complete unit etc complete as required i/c credit for old dismantle material under buy back |
| 23 | 1.5 Tr. Window / split type AC unit |
| 24 | 2 Tr Window / split type AC unit |
| 25 | Day to day maintenance, attending of complaints, servicing & cleaning of water cooler cum purifiers in New Delhi District Court Complex, Rouse Avenue, DDU Marg, New Delhi during normal working hours in a single shift of 8 hours on all working days except Sunday & holidays i/c. minor repair etc. complete as required. a) Operator/Technician - 01 No. |
| 26 | Supplying & replacement of following worm out / defective accessories in existing water cooler with in built RO i/c testing and commissioning etc. complete as required |
| 27 | Membrane 150 GPD |
| 28 | Filter 10 \\" Particulate/Sediment filter / Carbon Filter/Zinc Filter |
| 29 | 20 inch pre filter in the existing water cooler |
| 30 | Brass water cooler TAPS Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysJul 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender