Tender For Providing Illumination With Led Flood Lights In Children Park At Stc Bsf North Bengal.
Tender Value
97076
Estimated cost
Bid Submission
29 Jul 2026
4 days left
EMD
1942
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kalimpong → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Providing Illumination With Led Flood Lights In Children Park At Stc Bsf North Bengal.
BOQ
| Sl. No. | Item Description |
| 1 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. (a) Above 6.5 Meter and upto 8.0 Meter |
| 2 | Supplying of 8 Meter long standard swaged type steel tubular pole (ref drawing) with base plate of suitable design conforming to IS 2713 manufactured from tested quality mild steel tubular sections and painting etc complete as required. (a) 410 SP-12 overall length- 8 mtr, approx weight- 97 Kg + 4.24 Kg = 101.24 Kg) |
| 3 | Providing and fixing of 900 mm dia Pole Top Circular Lighting Bracket fitted on existing GI pole, fabricated from heavy duty 35 mm GI Pipe with minimum 4 mm thickness, including cutting, bending, welding, grinding, support clamps, nuts, bolts, anti-rust treatment, primer and two coats of weather resistant paint, complete for mounting flood LED lighting fixtures as per approved design and site requirement. |
| 4 | LED Flood Light, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66, IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.(Thermal management: heat sink of aluminium housing suchthat LED junction temperature shall not rise above 90°C). a ) 100 Watt |
| 5 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 6 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 7 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 8 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. (a) 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 9 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.(a) Upto 35 sq. mm |
| 10 | Providing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade (as per IS 7098 (part-I) 1988 with upto date amendments) alluminium conductor armoured power cable of following size as required. (Make Havells/ KEI/ Polycab) (a) 4 x 25 sqmm |
| 11 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 40 Amp |
| 12 | Supplying, installation, testing and commissioning of weather proof thermoplastic Loop box of size 217 x 253 x 115 mm ( Hensel/ Syntex make ) having transparent lid and required quantity blanking holes suitable for 4 X 25 sq.mm PVC UG cable including providing and fixing 1 Nos. 63 Amps capacity aluminium bars, 1 No. \\"B\\"-class 6-32 Amp SP MCB- 03 nos, drilling holes, connections, interconnections. |
| 13 | Supplying and wiring of existing pole with 1 sqmm PVC insulated copper conductor three core cable from end termination box to LED light fittings including connections, inter connection as per specification complete as per required. ( Three core 1 sqmm round PVC insulated FR-LSH PVC sheathed flexible cable of Havells make ) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysJul 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender