Housing Urban and Rular Development Government Departments Closing in 2 days TDR #56592853

Tender For General-Storage Of Evm & Vvpat-Additional Requirement Estimate For The Election Warehouse For Storage Of Evm & Vvpat Machines At Chathamangalam In Kozhikode District.-Electrification-General Electrical Work

Issued by Government Departments · Kozhikode, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
29 Jul 2026
2 days left
EMD
17336
Bank guarantee accepted
Document Fee
1530
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kozhikode → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for General-Storage Of Evm & Vvpat-Additional Requirement Estimate For The Election Warehouse For Storage Of Evm & Vvpat Machines At Chathamangalam In Kozhikode District.-Electrification-General Electrical Work

BOQ

Name of Work:- GENERAL-Storage of EVM & VVPAT-Additional requirement estimate for the Election warehouse for storage of EVM & VVPAT machines at Chathamangalam in Kozhikode district.-Electrification-General Electrical Work
Sl. No. Item Description
1Additional electrification
21.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C
390.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
490.3.21.3:Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture
5OD333696/2025-2026:Supply and fixing pressure die cast housing LED Bulkhead with IP65 protection suitable for surface and wall mounting applications including giving connection with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the Original wiring and making good the surface as required. (Philips make VistaGlow WT140W LED7S NW/CW PSU S1 PC or Techno commercial equivalent approved by engineer in charge )
6OD341869/2025-2026:Supply, Conveyance, installation, testing and commissioning of of LED Post top Luminaire having power consumption not more than 35 W and light output not less than 3500 Lumens with a nominal efficiency 100 lumen/watt. Internal surge protection up to 4 KV ,IK 5 with IP 65 protection The housing should be of non-corrosive ADC12Grade high-pressure die-cast. The Luminaire diameter must be minimum 300mm for larger area coverage .The Luminaire should be having Minimum 50000 Burning hours(L70B50) with CRI ≥70, SDCM< 5 and co-related colour temperature (CCT) of 4000- 5700K. The luminaire should be capable of withstanding voltage stress of `440V for 8 Hrs , should have an auto shutdown at 325V and have an auto recovery feature , Under Voltage protection with Input Voltage Stress of 100V for 48 Hrs. The Luminaire should have a 4 KV in the Luminaire. Total of 45 hits across all the three modes as per IEEE 62.41.2 The Drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire with PF>0.95 and THD<10%.Luminaire and driver shall be separately BIS approved of same make equivalent to Philips/ kesslec /Osram. LM80,LM79 ,Type Test certificate and Bis certificate need to be submitted.
790.15.4.1:Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
8OD336753/2025-2026:Supply, Conveyance, installation, testing and commissioning of LED focus Luminaire having power consumption not more than 10W, The housing should be of high-pressure die-cast and Electrostatically applied polyester powder coating finishing with IP66 and IK06. The Luminaire should be having Minimum 50000 Burning hours(L70B50) with CRI ≥70, SDCM< 5 and co-related colour temperature (CCT) of 3000K. The Drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire with PF>0.95 and THD<10%.Luminaire and driver shall be separately BIS approved of same make equivalent to Philips BVP353 C 4LED 30K 24V 10 10W IN/ kesslec /Osram. LM80,LM79 ,Type Test certificate and Bis certificate need to be submitted, and giving necessary connections as required.
9OD333691/2025-2026:Supply and fixing 200 mm plastic sill shade on the existing batten holder etc as required
1090.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
1190.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
12OD333690/2025-2026:Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of PVC insulated and PVC sheathed 3 cores round copper conductor flex wire conforming to relevant ISS. 300/305 mm sweep, 1400 rpm Heavy Duty Exhaust fan in metal frame working on 230 V A/C
13OD333692/2025-2026:Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS. 200 mm sweep Light Duty Exhaust fan in plastic body with self-opening lowers working on 230V single phase A/C
1490.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
151.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
161.17.4:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mm
171.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
181.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
191.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
201.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
211.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
221.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
231.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
241.24.2:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.2 way 5/6 amps switch
251.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
261.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
2790.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
281.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
291.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
301.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
3190.10.1.3:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface
321.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
331.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
341.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
3590.15.1.1:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters
3690.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
3790.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
3890.6.6.1:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.1.50 sq mm
3914.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
4014.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
4114.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
42OD334973/2025-2026:Steel reinforcement for RCC Work including straightening, cutting, bending, placing in position and binding all complete.
4314.11:Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels.
4414.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
452.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
462.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole
472.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole
482.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
492.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
502.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
51OD333754/2025-2026:Supplying and fixing following rating, Double pole, (Single phase and neutral), 240volts, residual current circuit breaker (Type A, RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.25 amps
522.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps
532.3.1:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)6 way, Double door
542.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door
552.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door
5690.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
5790.3.18.1:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.25 mm dia with HG company fabricated clamps
5890.12.5.3:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm
5990.12.5.41:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 16 sq mm
6090.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
6190.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
62OD334979/2025-2026:Supplying, fixing and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in surface,making good the damages colour washing etc. as required50/38 mm or nearest size
63OD338154/2025-2026:Supplying, fixing and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in surface. 77/63 mm or nearest size
6490.16.2.1:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.15.mm dia. G.I pipe ( medium class)
6590.16.2.4:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.40 mm dia G.I. pipe ( medium class)
667.10:Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
6790.12.7.3:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp
6890.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
699.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
709.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
719.1.22:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
729.1.24:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)
7390.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
7490.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
7590.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
7690.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
7790.16.3.18:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm aluminium strip
7890.16.4.15:Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm aluminium strip
7990.16.4.18:Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).32 x 6 mm aluminium strip
8090.16.3.20:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)32 x 6 mm aluminium strip
81OD337155/2025-2026:Providing and fixing 25 mm X 6 mm copper strip earth lead from the LA test joint to the earth test joint.
82OD337332/2025-2026:Supplying and laying 25 mm x 6 mm copper strip at 0.60 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
83OD333764/2025-2026:Providing and fixing 25 mm X 3 mm coper. strip earth lead from the test joint to the earth plate
84OD333765/2025-2026:Providing and fixing 2 X 25 mm X 3 mm copper. strip test joint for earthing system
85OD334985/2025-2026:Supplying and laying 32 mm x 6 mm G.I strip at 0.60 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I/S.S nut bolt & spring washer spaced at 50mm)
866.2:Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube,having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
876.3:Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required.
886.4:Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
89OD336768/2025-2026:Supply and fixing IP66 cable junction box for outdoor application of size 130 x 180 x 77mm with necessary leak proofing materials etc. provided at entry/exit as required (Hensel make model KF 1000 H or Techno commercial equivalent approved by engineer in charge).
90OD336769/2025-2026:Supply and fixing IP66 cable junction box including Terminal block connectors suitable for cable up to 6 sq. mm cable etc for outdoor application of size 130 x 130 x 77mm with necessary leak proofing materials etc. provided at cable entry/exit as required (Hensel make model KF 0606 G or Techno commercial equivalent approved by engineer incharge).
91OD341279/2025-2026:Supply and fixing IP66 cable junction box including Terminal block connectors suitable for cable up to 10 sq. mm cable etc for outdoor application of size 130 x 180 x 77mm with necessary leak proofing materials etc. provided at cable entry/exit as required (Hensel make model KF 1010 G or Techno commercial equivalent approved by engineer in charge).
925.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
93OD336477/2025-2026:Supply and fixing 50 mm dia 6 Kg/cm2 PVC pipe including fixing the pipe at 60 cm spacing. etc on wall with all required accessories and clamps etc. including cutting and making good the walls, painting the exposed portions etc. as required.
94OD333771/2025-2026:Supply and providing 25x3mm brass nut and bolt etc. as required
95OD333772/2025-2026:Supply and providing 25x6mm brass nut and bolt etc. as required
96OD337435/2025-2026:Dismantling the existing connections from change over switch panel board,Dismantling the change over switch panel board from position with out any damages conveyance to new location, attending petty repairs, cleaning, and re fixing the same new position including cutting hole on wall / floor using suitable nut and bolts ,rearranging the existing cable to the panel board, making good the damages, colour washing,giving necessary connections etc. as required.
97OD338159/2025-2026:Supply and fixing following rating Surge Protection Devices (3P+N) ,Conforms to IEC 61643-11, Type 1+2(Protection against direct and indirect lightning surges) ,I imp 8kA Maximum Discharge Current - Imax up to 100 kA in existing enclosure/cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Make L&T or Techno commercial equivalent approved by engineer in charge)
98OD339196/2025-2026:Supplying and fixing FP sheet steel enclosure for MCB on surface/ recess,making good the damages, colour washing etc. as required
99OD338158/2025-2026:Supply and wiring with ISI marked, FRLS PVC insulated following size single core copper conductor cables for interconnecting the control devices/ equipments including the wiring firm by suitable tie/ tie mounts/ PVC duct etc with sockets as required. 1 run 16 sq. mm
100OD341872/2025-2026:Supply, Installation, Testing and commissioning of single phase 1100VA/12V Sine Wave Inverter with 1No 12V 150Ah tall tubular batteries & Interconnecting cable with giving necessary connection etc. as required (Make Luminous/Okaya/Microtec/ Techno Commercial Equivalent)
101OD338160/2025-2026:Supply and wiring with ISI marked, FRLS PVC insulated following size single core copper conductor cables for interconnecting the control devices/ equipments including the wiring firm by suitable tie/ tie mounts/ PVC duct etc with sockets as required. 4 run 25 sq. mm
102OD348326/2025-2026:Supply and installation of CO2 type fire extinguisher of 4.5 Kg. Capacity with stored pressure type complete with installation brackets with ISI mark
103OD340729/2025-2026:Supply and providing 2.5mm thick Elastomeric fire retardant insulating mat as per IS 15652/2006 to withstand 11 KV dielectric strength including fixing with suitable synthetic adhesive.
104OD340766/2025-2026:Charges towards the preparation of necessary plan, scheme and other related papers for submission to Electrical Inspectorate / Fire & rescue service Department/ KSEB etc - First A3 Sheet
105OD340767/2025-2026:Charges towards the preparation of necessary plan, scheme and other related papers for submission to Electrical Inspectorate / Fire & rescue service Department/ KSEB etc - Each Additional A3 Sheet
106OD338157/2025-2026:Supply and drawing superior quality Aluminium Aerial Bunched Cable of 50 sq mm 5 core with suitable specials for K.S.E.B service connection
107OD336476/2025-2026:Supply and providing Dead end clamp with bracket for Aerial Bunched Cable with suitable specials for KSEB service
108OD340728/2025-2026:Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required2.5 cm, 4 cm, 5 cm height Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56592853
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 29-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for General-Storage Of Evm & Vvpat-Additional Requirement Estimate For The Election Warehouse For Storage Of Evm & Vvpat Machines At Chathamangalam In Kozhikode District.-Electrification-General Electrical Work
Basic Detail
Tender No PWD/BLDG/TR/448/2026
Bidding Type Tender
Location
City Kozhikode
State Kerala
Key Dates
Publish Date 21 Jul 2026
Submission Date 29 Jul 2026
Open Date 01 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee 1530
EMD 17336
Exemption Not Available
Document List
BOQ_1457434.xls
cd62eeb7-88a7-48a4-9198-23ace8a8a605.html
materiallist.pdf
nit.pdf
sbd.pdf
Tendernotice_1.pdf
Tendernotice_2 (6).pdf
Tendernotice_3 (1).pdf
Tendernotice_4.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Aug 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1457434.xls

html

cd62eeb7-88a7-48a4-9198-23ace8a8a605.html

pdf

materiallist.pdf

pdf

nit.pdf

pdf

sbd.pdf

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2 (6).pdf

pdf

Tendernotice_3 (1).pdf

pdf

Tendernotice_4.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders