Tender For Deposit-2026-27 - So-1981/26 - Improvement Of Water Supply To Manganoorkonam - Panachamoodu Road In Pattom Ward Under Kowdiar Section-Replacement Of Existing Age Old And Frequently Bursting 80Mm Ac Pipe With New 90Mm Pvc Pipe In Manganoork
Tender Overview
Project Description
Tender for Deposit-2026-27 - So-1981/26 - Improvement Of Water Supply To Manganoorkonam - Panachamoodu Road In Pattom Ward Under Kowdiar Section-Replacement Of Existing Age Old And Frequently Bursting 80Mm Ac Pipe With New 90Mm Pvc Pipe In Manganoorkonam - Panachamoodu Road In Pattom Ward Of Tmc Including Water Connection Alterations And Allied Works.-Pipeline Work-Based On The Request From Ward Councillor, Pattom Ward Tmc To Carry Out The Pipe Replacement Work Before Propsed Road Tarring Work Of Tmc.
BOQ
| Sl. No. | Item Description |
| 1 | App.C1 - Working charges |
| 2 | 100.59.1:Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffic diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation. |
| 3 | 15.59:Dismantling of flexible pavement ( bituminous courses ) by mechanical means and disposal of dismantled material up to a lead of 1 kilo metre, as per direction of Engineer-in-charge. |
| 4 | 100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil. |
| 5 | 100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete. |
| 6 | 100.9.8:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 90 mm nominal outside diameter pipes. |
| 7 | 100.9.9:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 110 mm nominal outside diameter pipes. |
| 8 | 100.46.2.1:Repairing leakage/breakage of 80mm A.C. pipeline by cutting and dismantling the damaged pipe portion (above 1.5m up to 3.0m) including charges for earthwork excavation in all kinds of soil including tar / concrete cutting for exposing leak portion of the pipe, operating control valves if any, conveying to the site and cutting new A.C. pipe to the required length, re-jointing the pipeline using C.I.D. Joints, testing the pipeline by operating the valves concerned, and rectifying the defects any noticed and without causing any damages to the existing utilities and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, charges for removing surplus soil from work site, including hire for tools and plant, conveyance of tools and materials, bailing out water, providing caution boards, lighting, watching, ribbon fencing, traffic controlling etc., complete as per the direction of Departmental officers excluding the cost of pipe and C.I.D. Joints. |
| 9 | 100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals. |
| 10 | 100.98.1008:Engaging Coolie. |
| 11 | 100.98.1009:Engaging Fitter ( grade 1). |
| 12 | 100.31.1.2:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 100mm diameter, Class I. |
| 13 | 100.31.1.1:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 80mm diameter, Class I. |
| 14 | 100.32.2:Conveying and fixing C. I. Single Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 40mm Single Acting Air Valve. |
| 15 | OD42495/2026-2027:Alteration of 20mm (3/4 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE pipe up to 200mm dia., up to a length of 5 m using 25mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe,, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges but excluding cost of water meter and meter box and excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers |
| 16 | OD42496/2026-2027:Interconnection of existing pipe lines with newly laid PVC pipe lines of size 50/63/75/90/110/160mm or GI pipelines of size 40/50/65/80/100mm using PVC equal Tee including charges for earth work excavation in all classes of soil and refilling, fencing, all labour charges, cost of all required materials, hire charges etc. complete as per direction of dept. officers. |
| 17 | OD53312/2026-2027:Disposal of marshy excavated earth including conveyance and loading charges etc. complete |
| 18 | OD53313/2026-2027:Supply, stacking and spreading coarse sand (zone III) in the pipe trenches as per standard norms including cost of all materials |
| 19 | 100.60.3.2.1:Providing additional length of house connection pipe using 25mm Indian Standard Class 6 uPVC pipe and specials and testing the joints etc., by trenching and refilling in all kinds of soil with trench of average cross section 0.3m x 0.75m for laying of connection pipe and service pipe, lighting, watching, providing caution boards, traffic control etc., including cost of materials, hire for tools, cost of consumables and labour charges etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads etc., and as per the directions of the department officers |
| 20 | 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 21 | App.C2 - Supply of materials |
| 22 | 100.98.236:Supply of PVC Pipe, 10kg/cm2, 90mm Dia. |
| 23 | 100.98.237:Supply of PVC Pipe, 10kg/cm2, 110mm Dia. |
| 24 | OD53760/2026-2027:Providing and fixing 80mm CID joint |
| 25 | OD42502/2026-2027:Providing and fixing of 90mm CIR joint |
| 26 | OD42505/2026-2027:Providing and fixing of 110x90mm dia. PVC Reducer |
| 27 | OD42508/2026-2027:Providing and fixing of 90mm dia.10Kg Equal Tee (Market rate) |
| 28 | OD42507/2026-2027:Providing and fixing of 90 mm dia. 90/45 degree PVC 10Kg elbow. |
| 29 | OD42501/2026-2027:Providing and fixing of 90mm dia.10Kg End cap (Market rate) |
| 30 | OD42509/2026-2027:Providing and fixing of 90mm dia. 10Kg long bend (Market rate) |
| 31 | OD52346/2026-2027:Providing and fixing 110mm PVC Flanged Tail piece |
| 32 | OD52347/2026-2027:Providing and fixing 110mm CIR joint |
| 33 | OD52348/2026-2027:Providing and fixing of 90mm PVC tail piece, 10kg/sqcm |
| 34 | OD52350/2026-2027:Supply of 100mm DI Double Flange Manually Operated Gate Valves (Sluice Valves) with Hand Wheel as per IS:14846/2000, Non-Rising Spindle type with GM Body Ring, Seat Ring SS 410 Spindle and Flange Drilling as per IS:1538, PN-2.0 |
| 35 | 100.98.457:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 80mm. |
| 36 | 100.98.441:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Single Orifice, Small Orifice Type S1, Size 40mm. |
| 37 | OD53306/2026-2027:Providing and fixing 40mm PVC valve |
| 38 | App.C3 - Construction of valve chambers |
| 39 | 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 40 | 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 41 | 4.3.2:Centering and shuttering including strutting, propping etc. and removal of form work for:Retaining walls, return walls, (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. |
| 42 | 5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide |
| 43 | 5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 44 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 45 | 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 46 | OD42498/2026-2027:Providing and fixing in position industrial type pressure gauges with gun metal/brass valves in pipe lines including all specials etc complete |
| 47 | OD42497/2026-2027:Providing and fixing 560 mm dia CI/DI MH cover with frame (Heavy duty with weight not less than 208kg) |
| 48 | App.C4 - Temporary road restoration |
| 49 | 3.1:Excavation for roadway in soil using manual means including loading in truck for carrying of cut earth to embankment site with all lifts and lead upto1000 metres. |
| 50 | 4.12:Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender