Housing Urban and Rular Development Government Departments Closing in 14 days TDR #56592667

Tender For Supply Installation Testing and Commissioning of Air-Conditioning System Including Their Necessary Electrical Works For Ejlas And Chamber In All Courts Of Zilla Adalat Bhawan, North 24 Parganas, Barasat. --Internal Electrical Installation

Issued by Government Departments · 24 Paraganas North, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
11 Aug 2026
14 days left
EMD
40000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
24 Paraganas North → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply Installation Testing and Commissioning of Air-Conditioning System Including Their Necessary Electrical Works For Ejlas And Chamber In All Courts Of Zilla Adalat Bhawan, North 24 Parganas, Barasat. --Internal Electrical Installation Work.

BOQ

Name of Work:- SITC of Air-conditioning System including their necessary electrical works for Ejlas and Chamber in all Courts of Zilla Adalat Bhawan, North 24 Parganas, Barasat. --Internal Electrical Installation Work.
Sl. No. Item Description
1Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required.
22 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [ For VRF AC Indoor Pt. - 59 Nos. ] [ 1(a)/(ii)/E-14 ]
32 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC [ For NON-VRF Split AC Pt. and other old Split AC Pts. - 11 Pts. ] [ 1(a)/(iii)/E-14 ]
4Supply, delivery & fixing of control cum transmission / power line wiring with following size Copper conductor sheilded cable along with conduit for looping between indoor & outdoor VRF system & to main Central remote controller system.1.1 KV GRADE PVC INSULATED COPPER ARMOURED CABLES
54 Core 16 mm² copper armoured Cable ( Make - Finolex/PolyCab/RR Kabel)
64 Core 25 mm² copper armoured Cable ( Make -Finolex/PolyCab/RR Kabel)
7Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall as per GS. -- [ 5(a)/E-17 ] [ For AC Pt. ]
8Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate as per GS. -- [ 17/E-19 ] [ For AC Pt. ]
9Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Legrand/North West/Havells) & necy. Connections. [ 5(b)/E-17 ] [ For VRF AC & NON-VRF AC Indoor Pt ]
10S & F AC Machine Timer Control Box fixed on wall fabricated with Double door ( 2 + 10 ) Way SPNDB enclosure as per -- ( Make - L&T, Cat no - LTSD12N ) incl. interconnection with suitable size of PVC insulated copper wire incl. Socketting with Copper socket with required size and following accessories -- i) 240/415 V, 32 A DP MCB of Breaking Capacity 10 KA & ''C'' Charecteristics ( Make - L&T ) - 1 nos. ii) 22A 2 Pole Power Contactor with 220 coil voltage ( Make -L&T, MNX - 22 - 2P with 1 NO, Cat no - CS94980 ) - 1 nos. iii) Digital Time Switch ( Make - L&T, Cat No - Crono 67DDTO ) - 1 nos. iv) LED lamp for Indication purpose -- 1 nos. v) Auto/Manual Toggle Switch -- 1 nos. vi) 2 Way Connector - 2 nos. [ NS ]
11Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthingterminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same as per GS -- 250 x 250 x 100mm [ 16(b)/I-2 ]
12Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages as per GS.
134 Way Enclosure (Make - Legrand/L&T/ABB) [ 14/D-10 ]
146 Way Enclosure (Make - Legrand/L&T/ABB) [ 14/D-10 ]
15Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damagesas per GS.
16Upto 160A, 6 Way Enclosure (Make - L&T/ABB) [ 15/D-11 ] [ For VRF AC Indoor Pt. for existing building of GF to 3rdF from proposed Normal Sub-Main LT Panel at 4th Floor of Vertical Extension]
17Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment.
186 way, Vertical [ 16/D-12 ]
19Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs as per GS. --
206-32 A SP MCB [ Make - Legrand/L&T/ABB ] [ 7/D-6 ]
2163 A TP MCB [ Make - Legrand/L&T/ABB ] [ 7/D-6 ]
22Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs as per GS. --
2340 A DP Isolator [ Make- Legrand/L&T ] [ 6/D-5 ]
2463 A FP [ Make - Legrand] [ 6/D-5 ]
25Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection.
26100A Four Pole [ Make - Legrand ] [ 10/D-8 ]
27Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes as per GS.
281.5 Sq mm [ NS ]
292.5 Sq mm [ 9(i)/ F-5 ]
304 Sq mm [ 9(ii)/ F-5 ]
31Supply of 4 Core PVC/XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes. [ Make - Polycab/Gloster/RR ]
324 core 35 Sq. mm Cable. [ NS ] [ From NVTPNDB to NTPNDB of of VRF AC IDU Pt. ]
334 core 50 Sq. mm Cable. [ NS ] [ From Proposed Sub-Main Normal Panel to NVTPNDB of IDU Pt. of VRF AC of GF to 3rdF ]
34Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire as per GS. -- [ 2(c)/F-1 ] [ For 4 Core 35 Sq mm. & 4 Core 50 Sq mm. ]
35Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damagesas per GS. --
36From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc. [ 5(i)/F-3 ] [ For 4 core 35 Sq mm. ]
37Above 35 sqmm to 95 sqmm at an average depth of 100 mm in floor/pavement/wall etc. [ 5(ii)/F-3 ] [ For 4 core 50 Sq mm. ]
38Laying of cable as below, on existing Cable Tray and binding withsuitable size GI wire.
39Up to 50 sqmm [ 6(i)/F-3 ] [ For 4 core 35 Sq mm. & 4 Core 50 Sq mm.]
40Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry as per GS.
41For 4 core 35 Sq. mm. [ 7(c) /F- 4 ]
42For 4 core 50 Sq. mm. [ 7(c) /F- 4 ]
43Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make) as per GS.
444 core 35 Sq mm. cable [ 8(b)/(xv)/F-5 ]
454 core 50 Sq mm. cable [ 8(b)/)(xvi)/F-5 ]
46Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. -- With 25x25x3mm angle iron support
47300x50x1.25mm (18SWG) [ 34(a)/(ii)/D-14 ]
48Supply & Fixing of perforated GI cable tray bend with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support.
49300x50x1.25mm (18SWG) [ 34(b)/D-15 ]
50Supply & Fixing of perforated GI cable tray tee with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support.
51300x50x1.25mm (18SWG) [ 34(c)/D-15 ]
52Supply & Fixing of perforated GI cable tray cross member with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support.
53300x50x1.25mm (18SWG) [ 34(d)/D-15 ]
54Supply & Fixing of perforated GI cable tray reducer with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the reducer incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support.
55300x50x1.25mm (18SWG) [ 34(e)/D-15 ]
56Dismantalling of the existing old electrical wiring from old existing MCB DBs etc. incl. existing old damaged fittings - fixtures etc. as per the direction of EIC. [ NS ]
57Making holes on RCC ceiling 125 mm depth having dia of following sizes :
58125 mm depth, 50 mm dia [ 9(b)/E-3 ]
59Additional charges for cutting the RCC Road and mending good the damages as to original finish after laying the cable through the existing GI Pipe protection as per size given below --
6040 mm dia [ NS ]
61Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. --
6240 mm dia [ 11(c)/F-6 ]
6350 mm dia [ 11(d)/F-6 ]
6465 mm dia [ 11(e)/F-6 ]
65Supply & Delivery & Installation, Testing & Commissioning of outdoor type Feeder Piller Box including floor mounted CPRI approved Cubical type LT Distribution Panel Board of Self Supporting Compartmentalized with Separate bus & Cable alleys made of 3mm thick CRCA sheet & angle iron frame supported incl. necy. interconnection by suitable size & grade Copper Cable / Solid link/ flat bar incl. making cable end terminal box float boxes after making drill holes ect. as required as per direction of E.I.C. The piller box should have appropriate size as per direction of EIC to accomodate the following equipments. Canopy and upper portion of the Feeder Pillar box is to be made from 5mm & 3mm thick MS Sheet respectively, and bottom portion with 10mm thick MS plate rigidly fixed by nuts bolts washer etc. The Piller Box will have double door with almirah type lock with 3 nos. keys. Additional provision of pad locking is to be provided with 2 nos. mechanical locks both top and bottom portion. Provision of ventilating grill should be triangular in shape made from MS Plate duly welded to lateral side. The centre ventilation spout at starting surface of the top of the pillar box. Provision of 2 Nos. earthing terminals by 25x6mm GI flat having suitable nuts, bolts & washers etc. Interconnection between incoming & outgoing Switches to be done with suitable size of copper wire.The pillar box is to be painted with 2 coats of synthetic enamel paint after one coat of RO primer. The internal EI works of the piller box should withstand 2KV rms AC Voltage for 1 minute. All fabrication work is to be done as per direction of EIC. The Piller box should contain the following arrangements :-
66(A) INCOMING:- (i) 415Volt , 415 Amp. FN type TPN Main switch incl. S & F 3 nos. HRC fuses as per rating. ( Make- L&T ) -- 1 Set (B) Bus Bar Chamber:- 415 Volts, 4 Bars Copper B.B.C incl. 4 Nos 600 Amp capacity Copper Bars of required size on DMC/ porcelain insulator of requisite length incl. drill hole etc. as required and as approved by E.I.C .
67( C ) OUTGOING :- ( i ) S&F of ELCB/RCCB on the existing inside Feeder Piller outdoor Panel as per rating 415 Volt, 100 Amp Four Pole ELCB/RCCB (Rated Residual Current-100mA) for protection ( Make -- L&T/Schneider/ABB/SIMENS/) -- 2 Set ( ii ) S&F of ELCB/RCCB on the existing inside Feeder Piller outdoor Panel as per rating 415 Volt, 63 Amp Four Pole ELCB/RCCB (Rated Residual Current-100mA) for protection ( Make -- L&T/Schneider/ABB/SIMENS/)-- 6 Set
68( D ) Metering Panel :-(i) S & F Current Transformer of size 600/5A ( Kappa make ) -- 3 Nos.(ii) LED Multifunction Meters [ L&T make WL441010OOOO ] -- 1 Nos.(iii) LED Indicator [ R,Y,B ] -- 3 Nos.(iv) 3P MCB C6 -- 1 Nos.(v) S & F Danger Notice Board -- 1 Set (vi) Connection with suitable size of Copper wire.
69( E ) Painting :- The complete Feeder Piller Panel board should be painted by 2 coats of powder coated synthetic enamel Paint over two coats of R.O. primer of Approved make & brand & color as per Direction of E.I.C. ( F ) Constructural Details :-All incoming & outgoing panel mounted cubical Switch disconnector fuse should be housed in Respective compartment with hinged & gasketted Door at front. All doors shall have Panel lock Arrangement. The panel shall be properly Gasketted to prevent ingress of dust & moisture & Remain. Busbar will be properly arrange & all Switches shall be fixed by M.S. nuts & bolts On angle /flat iron frame base as per direction of E.I.C.
70Foundation work should be done for installation of the above Feeder Piller box. The Feeder Piller box should be installed on the supporting structure made of 10\\" brick pedestal of required dimension as per the size of the Panel of 600 mm. above the Ground level incl. Sand Cement Plastering and neat cement finishing. Inside the brick pedestal, there will be filled up by loose sand where the incoming & outgoing cable will be in rest for trenching of cable. [ For Feeder Piller Box ]
71Scaffolding charges for lifting of the new Outdoor type Feeder Piller Box from ground floor to 1st floor open area roof top of the existing Police Lock up room with necy. arrangements as required as per the direction of E.I.C.
72Excavation of soil for installation of Earth Electrode and filling & ramming.
73For Soft Soil [ 1(a)/G-1 ]
74Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:
75By ISI - Medium GI Pipe [ 2(a)/ G-1 ] [ VTPNDBs & Feeder Piller Panel ]
76Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall as per GS. [ 4(b)/G-2 ]
77Connecting the equipments body to earth busbar including S & F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required as per GS. [ 5(c)/G-3 ]
78Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.
79Solid G.I. wire -- No. 4 SWG GI wire. [ 5(a)/(i)/G-2 ]
80Extra for providing masonary enclosure on the top of the earth electrode of overall size 86.36cm X86.36cmX46cm deep(below ground level) complete with cemented brick work (1:6) of 25 cm width duly plastered with cement morter (inside)CI hinged inspection cover of size 36.56cm X 35.56cm with locking arrangement ,GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [ 3(a)/G-2 ]
81Extra for treatment of soil by using salt & charcoal or coke for plate electrode. [ 3(b)/G-2 ] Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56592667
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 11-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for Supply Installation Testing and Commissioning of Air-Conditioning System Including Their Necessary Electrical Works For Ejlas And Chamber In All Courts Of Zilla Adalat Bhawan, North 24 Parganas, Barasat. --Internal Electrical Installation Work.
Basic Detail
Tender No WBPWD/SESEC/eNIT-12(2nd)/25-26
Bidding Type Tender
Location
City 24 Paraganas North
State West Bengal
Key Dates
Publish Date 21 Jul 2026
Submission Date 11 Aug 2026
Open Date 13 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 40000
Exemption Not Available
Document List
12NIT3rd.pdf
2911.pdf
6af5735d-ba4e-4152-88a5-14df1ab63d8a.html
BOQ_5087185.xls
Tendernotice_1 (16).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 11, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Aug 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
pdf

12NIT3rd.pdf

pdf

2911.pdf

html

6af5735d-ba4e-4152-88a5-14df1ab63d8a.html

xls

BOQ_5087185.xls

pdf

Tendernotice_1 (16).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders