Defence Statutory Bodies & Commissions/Committees Closing in 4 days TDR #56592258

Tender For Repair/Maint Of Internal Electrication Work Incl Replacement Of Unsv Electrical Fittings & Fixture, Wiring, Mcbs/Mcb Dbs With Misc E/M Works At Offrs Md Accn At Kirby Place, Map Kirby Place Under Ge (North) Delhi Cantt-10

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
40 Lakhs
Estimated cost
Bid Submission
18 Aug 2026
4 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maint Of Internal Electrication Work Incl Replacement Of Unsv Electrical Fittings & Fixture, Wiring, Mcbs/Mcb Dbs With Misc E/M Works At Offrs Md Accn At Kirby Place, Map Kirby Place Under Ge (North) Delhi Cantt-10

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 11-Aug-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-Aug-2026

BOQ

Name of Work:- REPAIR/MAINT OF INTERNAL ELECTRICATION WORK INCL REPLACEMENT OF UNSV ELECTRICAL FITTINGS & FIXTURE, WIRING, MCBS/MCB DBS WITH MISC E/M WORKS AT OFFRS MD ACCN AT KIRBY PLACE, MAP KIRBY PLACE UNDER GE (NORTH) DELHI CANTT-10
Sl. No. Item Description
1Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fittings and fixture such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces all as specified and directed.
2M&L for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunken zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass/stainless steel screws, cup washers etc and making good to the disturbed surface complete all as specified and directed for One light / bell / buzzer point controlled by one, one way switch 5/6 Amps.
3All as per the description of srl item No 02 here-in-before but one fan point controlled by one, one way switch 06 Amps.
4All as per the description of srl item No 02 here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch.
5All as per the description of srl item No 02 here-in-before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch.
6All as per the description of srl item No 02 above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
7Material & labour for point wiring concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm and connected to common earth and earth dolly with suitable copper lugs and modular metal flush box, modular white cover plate with frame, blanking plate etc suitable for up to required module etc in existing conduit complete and making good to the disturbed surfaces all as specified and directed for for One light / bell point controlled by one, one way switch 06 Amps
8All as per the description of srl item No 07 here-in-before but one fan point controlled by one, one way switch 06 Amps.
9All as per the description of srl item No 07 here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch.
10All as per the description of srl item No 07 here-in-before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch.
11All as per the description of srl item No 07 above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
12Material & labour for point wiring concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories and modular metal flush box, modular white cover plate with frame, blanking plate etc suitable for up to required module etc complete and making good to the disturbed surfaces all as specified and directed for for One light / bell point controlled by one, one way switch 06 Amps
13All as per the description of srl item No 12 here-in-before but one fan point controlled by one, one way switch 06 Amps.
14All as per the description of srl item No 12 here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch.
15All as per the description of srl item No 12 here-in-before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch.
16All as per the description of srl item No 12 above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
17S&F modular switch, 06 Amps, single pole, one way, 230 volts, one module and IP 20 protection complete all as specified & directed
18S&F modular switch, with indicator, 16 Amps, single pole, one way, 230 volts complete
19S&F modular bell push, with indicator, 6 Amps, single pole, one way, 230 volts complete
20S&F modular socket outlet 05 Pin, 06 Amps, 02 module with shutter complete
21S&F modular socket outlet 02 in 01, 03 pin, 6/16 Amps, 02 module with shutter complete
22S&F ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic, 02 module, humfree, AC, 230 volts, 120 watts incl connection complete
23S&F switch piano flush type, 06 Amps, single pole, one way, 230 volts complete
24S&F switch piano flush type, 16 Amps, single pole, one way, 230 volts with switch frame complete
25S&F socket outlet 2 in 1, 5 pin, 06 Amps, flush type, 230 volts with socket frame complete
26S&F socket outlet 2 in 1, 3 pin, 06 Amps and 3 pin, 16 Amps, flush type, 230 volts with socket frame complete
27S&F ding dong bell, AC, 230 volts, single pole complete
28S&F ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic, humfree, AC, 230 volts, 100 watts complete
29S&F ceiling rose, 6 Amps, 230 volts, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25mm size complete
30Supply and fix lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting including 9W LED bulb complete.
31S&F in repair 10/12W LED TL fitting (2 fit) attractive wall mounted type suitable for mirror fittings, all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete
32S&F in repair on wall / ceiling LED batten lighting fixture 20 watts LED 5700K (4'), with extruded aluminium heat sink, integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete.
33S&F decorative wall mounting light SS finish fixture with extruded glass difuser suitable for up to 40 watt mini glass lamp, lamp holder, including 9 Watts LED bulb for fixing in decorative wall mounting light and all accessories pre-wired including connecting up including taking down of existing u/s light fitting complete.
34S&F in repair Supply and fixing LED luminaire 600 mm x 600 mm x 70mm 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete complete.
35Supply and fixing LED street light fitting 72/75 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections and 50 mm bore light grade G. I. tube mounting bracket of 1.5 meter in length, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts & washers complete.
36Taking down of existing u/s highbay lights and Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. and all accessories complete, arrangements for mounting of fitting i.e. bracket, clamps, nuts, bolts and washers etc all as per site requirement including connecting up with provision of PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections complete.
37Material and labour for sub main wiring with 04 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified & directed, including taking down old sub main wiring.
38All as per the description of srl item No 37 here in before but 06 Sqmm nominal cross sectional area.
39All as per the description of srl item No 37 here in before but 10 Sqmm nominal cross sectional area, four single core, with and including continuous earth wire of size 06 Sqmm nominal cross sectional area.
40S&F in repair industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 230 volts of 20 Amps, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete
41S&F in repair sheet metal enclosure distribution board, single pole and neutral, AC, 230 volts, 08 way, with 200 Amps rated copper bus bar and metal double door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete
42All as per the description of srl item No 41 but 12 way
43S&F in repair sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volts, 04 ways with 200 Amps rated copper bus bar and metal door with IP 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed with and incl. of followings :- (a) MCCB, 125 Amps, 04 pole, AC, 415 Volts,16 KA - 01 No. (b) MCB, SP, AC, 230 volts of 06 to 32 Amps, \\"C\\" curve, 10 KA - 12 Nos.
44S&F in repair MCB, SP, AC, 230 volts of 06 to 32 Amps capacity \\"C\\" curve, 10 KA breaking capacity and making connections by using copper lugs complete
45S&F in repair MCB, DP, AC, 230 volts of 40 Amps capacity \\"C\\" curve, 10 KA breaking capacity and making connections by using copper lugs complete
46S&F in repair MCB, DP, AC, 230 volts of 63 Amps capacity \\"C\\" curve, 10 KA breaking capacity and making connections by using copper lugs complete
47Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 200/250mm, cutting of hole in wall, making of wooden frome, all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed
48S&F in repair MCCB, 100 Amps, 03 pole, AC, 415 Volts of 16 KA breaking capacity complete all as specified & directed.
49S&F in repair MCCB, 125 Amps, 03 pole, AC, 415 Volts of 16 KA breaking capacity complete.
50S&F in repair MCCB, 160 Amps, 04 pole, AC, 415 Volts of 36 KA breaking capacity complete
51S&F or passing through pipe, 10 Sqmm, 2 core, 1100 Volts grade, heavy duty, multi-stranded, PVC insulated, aluminium conductor, served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed service cable for service connections from existing LT Panel/Pole to DB/busbar chamber including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete
52Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louvers and taking down old exhaust fan and depositing to MES store yard all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed
53Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 220 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block to ceiling rose complete .
54M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete. (Note: On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.)
55S and F in replacement wall mounted fan of 400 mm sweep, 230 volts, AC, 50 Hz capacity, including all arrangements for mounting of fan with and including connecting up with provision of PVC insulated flexible copper conductor cable 1.5 Sqmm, 2 core as required for connections complete all as pecified and as directed. Make : Crompton / Havells / Khetan / Oreint.
56M & L in replacement of only Mod boxes with modular plate cover upto 03 module complete incl making good of disturbed surface etc all as specified and directed by Engr-in Charge.
57S&F for LED Based Outdoor Weatherproof Aviation Obstruction Lighting Luminaire wiith Inbuilt AC-DC Converter 48V / 160 – 230 VAC Housed in Die-Cast Aluminium (LM 6) / Aviation Orange Finish Ultra Violet Stabilised Acrylic Lens for directing light Built in Photo Controller / Built in SS Bird Spike Solid State high flux Light Emitting Diode / Intensity: 32.5 Candelas Life: >50000 Hrs / Sealed with EPDM Gasket Power Supply: AC-DC Converter 48V / 160 – 230 VAC Standards: Confirms to ICAO Annex 14-6, FAA AC No. 70/7460-IG, Radio Interference: BS 800/EN 55014 Connections, necessary welding, clamping,mounting with 32mm dia GI pipe, 1.2 mtr height,1.5 sqmm copper wire with 20mm PVC conduit fixing on work portions upto nine storeys height bldg incl taking down UNSV complete all as specified and directed.
58S and F in replacement LED post top lantern 20 Watts with die cast aluminium spigot spun aluminium powder coated top cover aluminium clear acrylic and IP 65/66 with and including all fixing arrangment,material required at site and connecting up with provision of PVC insulated copper conductor cable 1.5 Sqmm, 2/3 core as required for connections complete all as specified and directed.
59S and F in replacement garden light fitting 9/10 watts, rated LED, alluminium houing, powder coated, PMMA Diffuser. with and including of brick/PCC work all as requad at side but not less than in size 1X1X1 feet as directed by Engr.in Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56592258
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 18-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint Of Internal Electrication Work Incl Replacement Of Unsv Electrical Fittings & Fixture, Wiring, Mcbs/Mcb Dbs With Misc E/M Works At Offrs Md Accn At Kirby Place, Map Kirby Place Under Ge (North) Delhi Cantt-10
Basic Detail
Tender No GE/NORTH-77/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 11 Aug 2026
Submission Date 18 Aug 2026
Open Date 20 Aug 2026
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Available
Document List
BOQ_873691.xls
e4e421ee-23c3-4a21-8b12-8045ed2b7d35.html
Gen77.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 18, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 4 days
Aug 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Aug 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_873691.xls

html

e4e421ee-23c3-4a21-8b12-8045ed2b7d35.html

pdf

Gen77.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders