Tender for Repair/ Maintenance Of Feeder Pillars, Lt Capacitor Bank, Lt Joints And Associated Items Under Aor Of Ge(N) Patiala
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in treches in soft/loose soil n. exc. 1.5 meter wide and n. exc. 1.5 mtr depth and getting out, including trimming the sides and forming bottom surface to required levels for fixing pole/stay assembly and laying/taking out cables complete all as specified and directed. |
| 2 | Returning, filling trenches including spreading, levelling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed. |
| 3 | Removing of excavated material (soil) to a distance n. exc. 50 Mtr and dispositing where directed at a level n. exc. 1.50 Mtr above the starting point complete as directed. |
| 4 | M & L Sand cushioning to UG cables (8cm depth before laying of cable and 15 cm depth over the cable). Note :- Punned thickness only will be considered for payment. |
| 5 | M & L Bricks for protection cover to under ground cable (with standard size fly ash bricks) with width equal to length of brick laid dry and flat abutting each other complete all as specified and directed. |
| 6 | Supply & Laying jointing, testing and commissioning in replacement of LT XLPE, PVC insulated, PVC sheathed armoured 300 Sqmm, 3.5 core. LT 1100 volt grades heavy duty with aluminium stranded conductor through pipes, induct, on poles, in trenches etc complete all as specified and directed. |
| 7 | Supply & Laying jointing, testing and commissioning in replacement of LT XLPE, PVC insulated, PVC sheathed armoured 185Sqmm, 3.5 core. LT 1100 volt grades heavy duty with aluminium stranded conductor through pipes, induct, on poles, in trenches etc complete all as specified and directed. |
| 8 | Supply & Laying jointing, testing and commissioning in replacement of LT XLPE, PVC insulated, PVC sheathed armoured 150Sqmm, 3.5 core. LT 1100 volt grades heavy duty with aluminium stranded conductor through pipes, induct, on poles, in trenches etc complete all as specified and directed. |
| 9 | Supply & fixing or laying galvanised steel tubing 80mm bore medium grade (ISI marked) for protection of under ground cable on poles/ walls under road crossing etc of following sizes including dismantling and taking down existing pipe. |
| 10 | Supply & fixing or laying galvanised steel tubing 150mm bore medium grade (ISI marked) for protection of under ground cable on poles/ walls under road crossing etc of following sizes including dismantling and taking down existing pipe. |
| 11 | Supply installation, testing and commissioning in replacement Main LT Feeder panel board , outdoor type cubicle panel board suitable for 3 phase,4 wire 415 volt 50 hz factory febricated approved CPRI powder coated made out of 3.0 mm thick CRCA sheet and MS angle iron sectiom 40X40X6mm frame with front and back openable double door system with locking arragement louver and air vent gasket for netural flow of air with conopy, with inner compartment made out of 2.00 mm thick CRCA sheet duly compartmentalized for each MCCB's as incoming and outgoing with MCCB's, lockable arrangement with aluminium bus bar three phase and neutral of capacity of 400 amp marked red, yelllow, black and blue inslulators, made of high strength insulated material suitable 1100 voltage all controll PVC wires shall be with 2.5 sq mm multistrand copper conductor and shall be properly bunched, tied, frerruled for proper indication , fixed on PCC foundation complete. Note:- (i) LT panel manufacturer shall comply the IS/IEC-61439 (Part-1) : 2011 & IS/IEC-61439 (Part-2) : 2011 (ii) PCC shall be measured and paid separately. INCOMING:- (a) MCCB 400 Amps, Microprocessor based adjustable thermal and magntic type 4 pole, 415 Volts, 36 KA - 01 Nos (Ultimate breaking capacity ICs -Icu = 100 %) OUT GOING:- (a) MCCB 250A,415V 4Pole,36KA----2 Nos(b) MCCB 200A,415V 4Pole,27 KA---- 2 Nos (c) MCCB 63A,415V 4 Pole,16 KA---- 1 Nos(d) Digital type Volt meter 0-500 Volts square type with selector switch - 01 No.(e) CT of suitable size(f) Digital type Ammeter 0-400 Amps square type with selector switch - 01 No.(g) Wiring complete with copper wire of suitable size (h) Indicator lamp LED type, set of three marked red, yellow & blue - 01 Set.(i) Cable glands brass of suitable size for cable.For HQ 98 BDE OTM (main Transformer) |
| 12 | Supply installation, testing and commissioning LT sub Feeder piller board out door type cubicle panel board suitable for 3 phase,4 wire 415 volt 50 hz factory fabricated CPRI approved powder coated made out of 3.00 mm thick CRCA sheet and MS angle iron sectiom 40X40X6mm frame with front and back openable double door system with locking arragement louver and air vent gasket for netural flow of air with conopy, inner compartment made out of 3.15 mm thick CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arragement with alluminium bus bar three phase and neutral of capacity of 480 amp marked red, yelllow, black and blue inslulators, made of high strength insulated material suitable 1100 voltage all controll PVC wires shall be with 2.5 sq mm multistrand copper conductor and shall be properly bunched, tied, frerruled for proper indication , fixed on PCC foundation complete. Note:- PCC shall be measured and paid separately INCOMING:- (a) MCCB 320 Amps microprocessor based with adjustable thermal and magnetic 415 Volts,36KA, 4 pole (Ultimate breaking capacity Ics-ICu 100 %) .- 01 No. OUT GOING:- (a) MCCB 63 Amps with adjustable type 4 pole 415 Volts, 16 KA - 08 Nos (b) Digital type Volt meter 0-500 Volts square type with selector switch - 01 No.(c) Digital type Ammeter 0-400 Amps square type with selector switch - 01 No.(d) Wiring complete with copper wire of suitable size (e) Indicator lamp LED type, set of three marked red, yellow & blue - 01 Set.(f) Cable glands brass of suitable size for cable. |
| 13 | Supply, fabrication,installation,testing and commissioning factory made CPRI approved 440V AC LT APFC Panel indoor/outdoor type, Compartmentalized, Modular, Indoor type in 3.15 mm thick CRCA sheet of appropriate size, Front Operatable double doors, Front & Back Openable only, Dust & vermin proof, Cable entry through 2.00 mm CRCA Gland plates- Bottom only, Powder coated after 7-Tank Pre-treatment process - Siemens grey shade on body/doors & Orange shade on Mountung/ Gland Plates + Incomer Doors, 3phase HR sleeved Color Coded Copper Main Busbar of 600A-3 Nos with Transparent FRP Covers & on SMC/DMC Supports, 600 AMPS Copper Earth Busbar running across the whole length of the LT Panel with 2Nos. Studs at both the side-ends, Lifting arrangement/Hooks at the Top, wiring with Appropriate Size of Copper Industrial Cables, Black Painted Base frame- 40x40x6 MM MS angle Frame, Cable glands brass crommium plated of diffrent sizes suitable for incoming & outgoing MCCB's and fitted with following specified items |
| 14 | (a) Rating - 250kVAr APFC Panel 7% detuned hybrid APFC Panel (b)Incoming MCCB Microprocessor based Release with Overload & Short-circuit Protections Rating - 400 Amps TP MDO with Aux contacts- 01 No (Legrand,Schneider,ABB) (c) 440V AC TP MDXL type Heavy Duty low loss Capacitors in Cylindrical/ Square body of following ratings: (d) 25KVAr x 2NOs. + 50 KVAr x 4Nos. And 7% Detuned harmonic filter reactors-6 sets. (e) 415V AC TP Microprocessor based intelligent PF Correction Relay Controller 12 Stage with 3CT sensing capability ( Schneider,ABB,C&S,Legrand Make) (f) For 25KVAr, 525 V Heavy duty Capacitor Banks - 02 SetsMCCB 63A TP 10 kA & Thyristor Switching Module suitable for 25 kVAr Capacitor Step complete with SCR assembly, triggering circuit, heat sink and accessories (g)For 50KVAr, 525 V Heavy duty Capacitor Banks - 04 SetsMCCB 125A TP 10 kA , &Thyristor Switching Module suitable for 25 kVAr Capacitor Step complete with SCR assembly, triggering circuit, heat sink and accessories (h) For regular Cooling of Capacitor Banks - 1Set2Sets Cooling Fans 9\\" with Air Filter ( On Top), 8Sets Cooling Fans 6\\" with Air Filters (at back & side walls), 2 Nos. Power Contactor 16A AC-3Duty with Aux. Contacts, 2Nos. Multifunction Cyclic Timer (Make:Radix/Schneider,ABB,C&S,Legrand), MCB SP 2A 'C' Curve for Control Circuit, Luminious Type Auto-Manual Selector Switch (i) Metering - 1SetMultifunction meter having RS 485 port to transmit data. CTs Cast Resin/Moulded Case 1000/5A. CTs Cast Resin/Moulded Case for IPFCR as per thr load of Main Transformer Panel, RYB Phases+ACB on/off/Trip Indications LED Type, Control Fuses with 4A Glass carrier, LED 14/15W SP 220V AC for Panel Lighting with door Limit switch - 2Sets, Panel Space Heaters with Thermostats and MCB DP of appropriate rating. |
| 15 | Supply, fabrication,installation,testing and commissioning factory made CPRI approved 440V AC LT APFC Panel indoor/outdoor type, Compartmentalized, Modular, Indoor type in 3.15 mm thick CRCA sheet of appropriate size, Front Operatable double doors, Front & Back Openable only, Dust & vermin proof, Cable entry through 2.00 mm CRCA Gland plates- Bottom only, Powder coated after 7-Tank Pre-treatment process - Siemens grey shade on body/doors & Orange shade on Mountung/ Gland Plates + Incomer Doors, 3phase HR sleeved Color Coded Copper Main Busbar of 400A-3 Nos with Transparent FRP Covers & on SMC/DMC Supports, 400 AMPS Copper Earth Busbar running across the whole length of the LT Panel with 2Nos. Studs at both the side-ends, Lifting arrangement/Hooks at the Top, wiring with Appropriate Size of Copper Industrial Cables, Black Painted Base frame- 40x40x6 MM MS angle Frame, Cable glands brass crommium plated of diffrent sizes suitable for incoming & outgoing MCCB's and fitted with following specified items |
| 16 | (a) Rating - 200kVAr APFC Panel 7% detuned hybrid APFC Panel (b) Incoming MCCB Microprocessor based Release with Overload & Short-circuit ProtectionsRating - 320 Amps 4Pole MDO with Aux contacts- 01 No (Legrand,Schneider,ABB) (c )440V AC TP MDXL type Heavy Duty low loss Capacitors in Cylindrical/ Square body of following ratings: (d) 25KVAr x 4NOs. + 50 KVAr x 2Nos. And 7% Detuned harmonic filter reactors-6 sets. (e ) 415V AC TP Microprocessor based intelligent PF Correction Relay Controller 12 Stage with 3CT sensing capability ( Make: Schneider,ABB,C&S,Legrand) (f )For 25KVAr, 525 V Heavy duty Capacitor Banks - 04 SetsMCCB 63A TP 10 kA & Thyristor Switching Module suitable for 25 kVAr Capacitor Step complete with SCR assembly, triggering circuit, heat sink and accessories (g ) For 50KVAr, 525 V Heavy duty Capacitor Banks - 02 SetsMCCB 125A TP 10 kA , &Thyristor Switching Module suitable for 25 kVAr Capacitor Step complete with SCR assembly, triggering circuit, heat sink and accessories (h ) For regular Cooling of Capacitor Banks - 1Set2Sets Cooling Fans 9\\" with Air Filter ( On Top), 8Sets Cooling Fans 6\\" with Air Filters (at back & side walls), 2 Nos. Power Contactor 16A AC-3Duty with Aux. Contacts, 2Nos. Multifunction Cyclic Timer (Make:Radix/Schneider,ABB,C&S,Legrand), MCB SP 2A 'C' Curve for Control Circuit, Luminious Type Auto-Manual Selector Switch (i) Metering - 1SetMultifunction meter having RS 485 port to transmit data. CTs Cast Resin/Moulded Case 1000/5A. CTs Cast Resin/Moulded Case for IPFCR as per thr load of Main Transformer Panel, RYB Phases+ACB on/off/Trip Indications LED Type, Control Fuses with 4A Glass carrier, LED 14/15W SP 220V AC for Panel Lighting with door Limit switch - 2Sets, Panel Space Heaters with Thermostats and MCB DP of appropriate rating. |
| 17 | Supply, fabrication,installation,testing and commissioning factory made CPRI approved 440V AC LT APFC Panel indoor/outdoor type, Compartmentalized, Modular, Indoor type in 3.15 mm thick CRCA sheet of appropriate size, Front Operatable double doors, Front & Back Openable only, Dust & vermin proof, Cable entry through 2.00 mm CRCA Gland plates- Bottom only, Powder coated after 7-Tank Pre-treatment process - Siemens grey shade on body/doors & Orange shade on Mountung/ Gland Plates + Incomer Doors, 3phase HR sleeved Color Coded Copper Main Busbar of 400A-3 Nos with Transparent FRP Covers & on SMC/DMC Supports, 400 AMPS Copper Earth Busbar running across the whole length of the LT Panel with 2Nos. Studs at both the side-ends, Lifting arrangement/Hooks at the Top, wiring with Appropriate Size of Copper Industrial Cables, Black Painted Base frame- 40x40x6 MM MS angle Frame, Cable glands brass crommium plated of diffrent sizes suitable for incoming & outgoing MCCB's and fitted with following specified items |
| 18 | (a) Rating - 150kVAr APFC Panel 7% detuned hybrid APFC Panel (b) Incoming MCCB Microprocessor based Release with Overload & Short-circuit ProtectionsRating - 250 Amps 4Pole MDO with Aux contacts- 01 No (Legrand,Schneider,ABB) (c ) 440V AC TP MDXL type Heavy Duty low loss Capacitors in Cylindrical/ Square body of following ratings: (d )12.5KVAr x 2NOs. +25KVAr x 3NOs. + 50 KVAr x 1Nos. And 7% Detuned harmonic filter reactors-6 sets. (e ) 415V AC TP Microprocessor based intelligent PF Correction Relay Controller 12 Stage with 3CT sensing capability (Schneider,ABB,C&S,Legrand ) (f ) For 12.5KVAr, 525 V Heavy duty Capacitor Banks - 02 SetsMCCB 32A TP 10 kA & Thyristor Switching Module suitable for 12.5 kVAr Capacitor Step complete with SCR assembly, triggering circuit, heat sink and accessories (g ) For 25KVAr, 525 V Heavy duty Capacitor Banks - 03 SetsMCCB 63A TP 10 kA & Thyristor Switching Module suitable for 25 kVAr Capacitor Step complete with SCR assembly, triggering circuit, heat sink and accessories (h) For 50KVAr, 525 V Heavy duty Capacitor Banks - 01 SetsMCCB 125A TP 10 kA , &Thyristor Switching Module suitable for 50 kVAr Capacitor Step complete with SCR assembly, triggering circuit, heat sink and accessories (i) For regular Cooling of Capacitor Banks - 1Set2Sets Cooling Fans 9\\" with Air Filter ( On Top), 8Sets Cooling Fans 6\\" with Air Filters (at back & side walls), 2 Nos. Power Contactor 16A AC-3Duty with Aux. Contacts, 2Nos. Multifunction Cyclic Timer (Radix,Schneider,ABB,C&S,Legrand ), MCB SP 2A 'C' Curve for Control Circuit, Luminious Type Auto-Manual Selector Switch (j) Metering - 1SetMultifunction meter having RS 485 port to transmit data. CTs Cast Resin/Moulded Case 1000/5A. CTs Cast Resin/Moulded Case for IPFCR as per thr load of Main Transformer Panel, RYB Phases+MCCB on/off/Trip Indications LED Type, Control Fuses with 4A Glass carrier, LED 14/15W SP 220V AC for Panel Lighting with door Limit switch - 2Sets, Panel Space Heaters with Thermostats and MCB DP of appropriate rating. |
| 19 | M&L for taking out under ground cable 1100 volt grade of any size from trenches, ducts floor, pipes and removing materials from site of work complete all as directed by Engineer-in-charge. |
| 20 | M&L for auguring of hole suitable for passing 40mm to 100mm bore pipe in true horizontal position under road, PCC paths etc., by means of mechanical ring/ auger after doing ultrasound to prevent any damage to existing cables pipe line specified and directed coming in the route not exceeding 1.5 m in depth below existing surface level of road including HDPE pipe 150mm dia suitable for 0.4 MPA working pressure complete all as specified and directed. |
| 21 | M&L for taking down of old/rusted LT panel board/feedr pillar by removing connected cables etc from site complete all as specified and directed by Engr-in-Charge. |
| 22 | Cutting of wornout / burnt aluminium cable terminal lugs from the HT/LT cable , crimping of new aluminium cable core and fixing with transformer, Panel MCCB terminal stud including cutting/ dressing of cable,disconnecting under ground cable from over head conductor , cutting down wornout portion under ground cables of any type and size for repairs including taking out under ground cable loop from ground and making connections of restoration of electric supply complete all as specified.Note:- Excavation, earth work , taking out cable protection covers, and sand cushion and relaying the same shall be deemed included in the unit rate quoted by Contractor) |
| 23 | M&L for repair of LT panel board, including welding of doors/hinges/ locking arrangement,Scrapping, cleaning, and preparation of old painted surface of LT feeder pillar box, painting with one coat of synthetic enamel paint of approved colour by spray gun complete including necessary spares like lugs. Insulation tape, connectors to make funcional all voltmeter,ammeter selector switchs, indication lamps etc and writing of panel descriplton on panel indicating area feeding complete all as directed by Engr-in charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysAug 13, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender