Tender For special Repair To Ante Room,Dining Hall,Cook House &Entrance Lobby Of Bldg No P-210 At Misa C Area Under Ge (S) Tezpur
Tender Value
37.87 Lakhs
Estimated cost
Bid Submission
04 Aug 2026
5 days left
EMD
75800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sonitpur → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair To Ante Room,Dining Hall,Cook House &Entrance Lobby Of Bldg No P-210 At Misa C Area Under Ge (S) Tezpur
BOQ
| Sl. No. | Item Description |
| 1 | Taking down cement plaster on brick/concrete surfaces of walls and ceiling including racking out jointing hacking for key, scrubbing down with water etc complete all as specified & directed |
| 2 | Taking down chowkhats incl shutterrs (without taking off shutters from the frame) exc 1.5 sqm and n.exc 4 sqm each . complete all as specified & directed. |
| 3 | Taking down chowkhats incl shutterrs n exc 1.5 sqm complete all as specified & directed. |
| 4 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified & directed. |
| 5 | Demolition of Cement Concrete of any description and in any position complete all as specified & directed. |
| 6 | Demolition of RCC of any description complete all as specified & directed. |
| 7 | M&L for R C C 1:2:4 (20mm gradded agg) as in slab supported on wall, beam , landing ,deck slab etc.complete as specified and directed |
| 8 | Use and waste Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified & directed. |
| 9 | S&F 10mm dia and over deformed TMT bars as in reinforcement,cut to length bent to shape etc as required incl binding with MS wire annealed not less than 0.90m dia. complete all as specified & directed. |
| 10 | S&F including Taking up or down existing 15mm bore medium grade galvanished tube with all fitting & fixed complete to walls or ceiling & laid in floors complete all as specified & directed. |
| 11 | S&F including Taking up or down existing 20mm bore medium grade galvanished tube with all fitting & fixed complete to walls or ceiling & laid in floors complete all as specified & directed. |
| 12 | S & F Pressed steel frames of size 105x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed complete all as specified & directed. |
| 13 | S & F 35 mm thick flush shutter double leaf , solid core construction ,with block board core and plywood face panel ,commercial type on both side. complete all as specified & directed. |
| 14 | S & F powder coated Anodised aluminium frame for doors, three track windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 15 | M&L powder coated Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified |
| 16 | S&F powder coated aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified, complete all as specified and directed. |
| 17 | Materials and Labour for mid steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed. |
| 18 | S/F 4mm thick ordinary quality sheet glass in squares exc 0.5 sqm in each pane fixed in aluminium frame complete all as specified & directed. |
| 19 | S/F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 20 | S&F 150mm long aluminium handle, cast type, anodised complete all as specified & directed |
| 21 | S&F 125 mm aluminium anodised barrel tower bolt, of extruded section and fixed in position complete all as specified & directed |
| 22 | S/F 300mm long M.S sliding door bolt, bolt type stove enameled black with bright bolt not less than 12mm dia and including a minimum of six bolts and nuts four on bolt plate & two on staple plate.complete all as specified & directed |
| 23 | S & F Mortice lock of brass of four levers ,vertical type, size 100 mm, complete all as specified and as directed |
| 24 | S & F Floor door stopper 14cm long of aluminium alloy body and tongue, anodised,with hard drawn steel spring, complete all as specified and as directed |
| 25 | M/L for 2 coats of synthetic enamelled paint over coat of pink primer on wooden surfaces oves 10cm width or girth including preparation of new surface.complete all as specified & directed |
| 26 | M & L including installation OF modular kitchen of size Length=5.5Mtr and Height=0.7Mtr to 0.8mtr with following acessories, complete all as specified and directed.(a) Handle type - profile handle fancy type of suitable size -22 Nos(b) Carcase - 18-19 mm thick ply BWR Grade comercial type, laminated with 0.7 mm thick plain finish sunmica using adhesive of best quality , colour and pattern as approved by GE.(c) shelf and shutters- 18-19 mm thick ply BWR Grade comercial type, laminated with 1 mm thick matt/glossy finish sunmica using adhesive of best quality , colour and pattern as approved by GE.(d) Basket :- (i) Stainless steel designer cup and saucer basket of size 530 mm wide , 505 mm depth and 100 mm height -04 Nos (ii) Stainless steel perforated peep hole cutlery basket of size 530 mm wide 505 mm depth and 100 mm height -06 Nos(iii) Stainless steel designer plain basket of size 530 mm wide , 505 mm depth and 150 mm height -04 Nos(iv) Stainless steel pull out basket of size 160 mm wide, 505 mm depth and 530 mm heiht - 04 Nos(v) Stainless steel designer thali/ plate basket comb of size 530 mm wide , 505 mm depth and 200 mm height -04 Nos(e) Channel /soft closing / telescopic channel 18 \\" to 20\\" size (45 Kg) suitable for basket /drawer.(f) SS auto hinges of best quality for shutters with 95 degree opening angle 14-32 mm zinc coating -136 Nos |
| 27 | M&L 10mm thick rendering in cm (1:6) on other than fair faces of brick work finished even & smooth without using extra cement complete all as specified & directed |
| 28 | M&L 15mm thick rendering in cm (1:4) on fair faces of brick work with using WPC @ 3% finished even & fair.complete all as specified & directed |
| 29 | M&L 5mm thick rendering in cm (1:3) on ceiling finished even of smooth without using extra concrete. |
| 30 | M&L for providing, cement concrete type B0, 1:2:4 (using 12.5mm graded aggt) in haunching of chajjas, roof kerbs or mud stops, rounded or chamfered on edges complete all as directed |
| 31 | M&L applying two coats of distemper over a coat of primer over a coat of 3mm thick a layer of wall care putty on walls complete all as specified & directed |
| 32 | M&L two coats of oil bound distemper over a coat of primer over 3mm thick layer of wall care putty after complete removal of existing treatment complete all as specified & directed |
| 33 | M&L three coats of white washing to ceiling including preparation of new surfaces.complete all as specified & directed |
| 34 | M & L for two coats of exterior emulsion antifungus paint over a coat of primer over a coat of 3 mm thick wall care putty to wall including complete including preparation of surface as specified and directed |
| 35 | M & L for two coats of exterior emulsion antifungus paint over a coat of primer over a coat of 3mm thick wall care putty to wall including complete including preparation after complete removal of existing treatment as specified and directed |
| 36 | Supply only integral water proofing compound |
| 37 | M&LScreed bed or bedding layer of mortar 15 mm thick for laying floor finishes in cm 1:6 complete all as specified & directed |
| 38 | M & L for Rendering or Backing Layer 10mm thick in Cement Mortar 1:3 on Walls, etc. for fixing Tiles as Skirtings, Dados,risers etc, complete all as specified and directed. |
| 39 | M&L Virified Ceramic tiles light shade double charged of size 1200x600x8-10 mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified & directed |
| 40 | M & L for Virified Ceramic tiles of light shade of size 600x600x8-10 mm thick (square/ rectangular) polished, area of each tiles lot in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 41 | All as item no 39 & 40 above, but in vertical walls/skirting complete all as specified and directed. |
| 42 | M & L for Non - skid Ceramic tiles (coloured) of size 400x400x8-10mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed |
| 43 | M & L for glazed ceramic wall tiles of size 450 x300 x 8-10 mm thick set jointed in neat cement slurry and pointed with white cement to match the tiles complete in skirting/dado. complete all as specified and directed. |
| 44 | M & L for pre-polished machine cut kota stone on flooring/staircase 16-18mm thick over cement screed bed laid and jointed with grey cement slurry mixed and with pigment to match the shade of slab including rubbing/grinding and polishing complete all as specified and directed. |
| 45 | M&L Granite (of any type) 18-20 mm thick work (table rnbbed and polished) in steps, janlbsl pillars; window-eills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. complete all as specified and directed. |
| 46 | M & L for Granite (of any type) 20 mmwork (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1 :3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. complete all as specified and directed. |
| 47 | S&F 20 mm dia steelness steel curtain rod including brackets , stops, rollers and side nubs etc with all fitting and fixture complete all as directed by Engineer In Charge. |
| 48 | S&F double bowl without drainage board sinks overall size 41\\"x20\\"x8\\" {304 Grade Stainless Steel} Pressed Double Bowl Sink with Waste Coupling | 25 Yrs Warranty on Product by Brand (Imperio, Matt) fixing with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe |
| 49 | Material and labour for Cleaning, removing old APP base polymeric membrane and preparation of roof/wall (RCC/BRICK/Miles/Cement concrete) surface and made free of dirt, foreign particles, laitance followed by grinding all protrusions to make surface modulated. Thereafter, inspection for cracks on the surface caused by thermal expansion/ contraction and repairing the cracks on the surface caused by thermal machine filled with Repair Mortar/General purpose Grout in the proportions as recommended by manufacturer supplying and applying High performance Hybrid Polyurea waterproofing coating spray/hand applied liquid membrane with following specifications(a) Elongation of range 400% 600%(b) Tensile strength of 8-12 N/mm2.(c) Crack bridging ability of 3,00-4.00mm(d) Hardness (Shore A ASTM D2240) of range 50-70The application shall include final base preparation epoXy primer application in rato 1.1 (resin: hardner) with 100% water dilution and application of Hybrid polyurea in two coats in d hrs interval to achieve total min thickness 1 to 1.50mm. The application/ treatment shall be carnec out by authorized rep of approved specialist firm/manufacturer.Make SIKA/FOSROC/Asian Paints/BergerNote. The defect liability period of water proofing treatment to RCC roof slab including sunker floor shall be 10 years and the contractor shall be responsible to keep the entire building(s) free From leakage/seepage for a period of 10 years after certified date of completion. The contractor may obtain a similar guarantee from the specialist firm engaged by him for the purpose. |
| 50 | Demolition of brick work built in cement mortar including all quions, arches pillars etc. all as specified and directed. |
| 51 | M&L brick work using sub class ‘B’ bricks (old size) straight or curved on plan to any radius in half brick work built in CM 1:4 complete all as specified. |
| 52 | M&L Material and labour for Brickwork with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM (1:6) in all as specified and directed. |
| 53 | M&L 12mm thick Toughned glass including all assecories for fixing with stainless steel spigot, dorma door patch fitting set, ething , toughened glass doors include patch fittings (top, bottom, or locks), floor springs, and hinges (like wall-to-glass or glass-to-glass hinges) including all other common components are spider fittings, door closers, and glass door handles. and similar work including cutting to shape, drilling holes required complete all as specified and directed by Engr-in-charge |
| 54 | M&L Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steelheavy duty and fixed complete all as specified and directed by Engr-in-charge |
| 55 | M&L Dismantling of wall & ceiling Boards (fibre,pulp, insulation etc), or insulation board/slabs/ blankets ,any thickness, including cover fillets. |
| 56 | S&F in repair exposed GI powder coated snap grid frame of false ceiling 600 X 600 mm size of wall angle 25 X25 X 0.35mm size cross Tee 24 X 38 X 0.70mm with 4mm dia GI suspender fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm including supply and fixing of 4 mm thick E- board in false ceiling including fixing arrangement from roof and applying three coats of white wash on exposed surfaces all as specified and directed. (Note- Rate included for lowering / shortening of electric fittings such as fan, light fittings etc. |
| 57 | S&F, providing and fixing Gypsum Board 12mm thick as in ceiling fixed with screw, including cutting holes complete as per manufacturers instructions and directed |
| 58 | Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. all as specified |
| 59 | M&L Dismantling wrought iron or mild steel work of any description not otherwise provided for roof truss or purlin, girder |
| 60 | Dismantling of steel/galvised sheet corrugated / Semi corrugated sheets in wall cladding or in roof covering |
| 61 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) , steel tubes including distance pieces, cleats etc. |
| 62 | M & L Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with L type J type or cranked hook bolts as specified and directed |
| 63 | M & L Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall/eaves board, fixed wiith L type J type or cranked hook bolts as specified and directed |
| 64 | M&L lnsulated PVC Wall Lining hollow type 15mm thick and above consisting of PVC Insulated Panels having expanded polystyrene (EPS) stuck to 2mm thick plain colour PVC sheet duly fitted into the wall as per specifications and drawing , design, patteren etc as approved by engr-in-charge |
| 65 | Endura heavy duly Royal Moss Designer Tile of size 600 x 600 mm 15mm to 20 mm thick of products like Coated Grey Plus, Majorda, Silver Grey Plus Special, Cavelo, or other parterns , desgns as approved by Engr-in-Charge |
| 66 | S&F of mild steel plates for walls, chimneys, roofs, arches, etc. king rods and straining bolts , conforming to Fe- 290 Gde-E-165 including welding with hinges, handles complete all as specified and directed |
| 67 | S&FS&F PVC board /sheets for fabrication of kitchen cabinets of depth 700mm below kitchen platform to be made as per following specification -Main outer body/carcuss shall be made using 18mm thick Pre-laminated plain white solid PVC board of density not less than 550 kg/cum.on top, bottom, LHS & RHS. Backside of main body shall be fixed with 5mm thick PVC plain white sheet. 1x shelves shall be provided using 18mm thick plain white solid PVC board of density not less than 550 kg/cum. 18mm thick prelaminated PVC sheet with decorative finish on one face and other face white having density not less than 600 kg/cum shall be used for shutters on front including fixing using stainless steel auto hinges of best quality, partition, PVC beading on edge and lining and lining as required. Backside of main body shall be fixed with 5mm thick PVC plain white sheet. Note: - Only front face to be measured for payment purpose. |
| 68 | S&F PVC board /sheets for fabrication of kitchen cabinets of depth 300mm for Overhang Kitchen Cabinet to be made as per following specification Main outer body/carcuss shall be made using 18mm thick prelaminated plain white solid PVC board of denisity not less than 550 Kg/Cum on top , bottom, LHS & RHS, backside of main body shall be fixed with sheet, 1xshalves shall be provided using 18 mm thick white solid PVC board of density not less than 550 Kg/ Cum Backside of main body shall be fixed with 5mm thick PVC plain white sheet. Note: - Only front face to be measured for payment purpose. |
| 69 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing |
| 70 | S & F PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supply & fixing in opening as per specification & drawing. |
| 71 | S/F 35 mm thick 2nd class hard wood glazed and skeleton shutters open rebated and prepared to receive glass gauge etc. Divided into squares with plain chamfered or rounded, rebated sash bars, sizes of the members of the shutters as specified and directed |
| 72 | S&F in repairs 18306vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, withintegral foot rests (excluding flushing cistern and flush pipe) |
| 73 | S&F in repairs 10 litre capacity PVC low level flushing cistern including pull chain & flush pipe, connection pipe etc complete all as specified & directed. |
| 74 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete. |
| 75 | S & F in repairs PVC connection 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed |
| 76 | S&F in repairs 15mm bore fancy type chromium plated bib taps with crutch or butterfly handle screwed down for iron pipes. |
| 77 | S&F in repairs 15 mm bore stop valve fency type with capstan heads, chromium plated screwed down, high pressure, with crutel or butterfly handle, screwed both ends for iron pipe or for unions. |
| 78 | S&F in repairs pillar taps fency type with capstan heads, chromium plated, srewed down high pressure, with or without lettered `Hot' or `Cold' with long srewed shanks and fly-nuts, screwed for iron pipe and fixed in 15 mm bore. |
| 79 | S&F in repairs 15mm bore 125mm size type brass chromium plated shower rose, complete all as specified. |
| 80 | S & F in repairs vitreous china white wash hand basin glat back of size 550 x 400 mm including brackets CP waste pipe and waste coupling 32 mm and PVC waste pipe and 15mm PVC connection complete. |
| 81 | S & F in repairs Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 190gms) |
| 82 | S&F Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets,flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) |
| 83 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete,including fixture and fittings such as switches,ceiling roses,pendants,regulators,sockets,light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. |
| 84 | M&L for Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC concealed conduit 20mm dia medium duty with all accessories including modular GI boxes of suitable sizes including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fan point controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan/call bell point/ Switch socket outlet 5 amps complete all as specified and as directed.Note: (i) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (Rate deemed to be inclusive of cutting chases and making good disturbed surface). |
| 85 | All as per item No. 02 here-in-before but one 3 pin 5 amps switch socket commbination on the independent board with other switch complete all as specified and directed by Engineer-in-charge. |
| 86 | All as per item No. 02 here-in-before but one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engineer-in-charge. |
| 87 | M & L for point wiring for socket out let on 16 Amps independent Boards controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including metal flush box suitable for modular cover plate with frame of suitable size of 3M and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLS PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.Note: (i) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (Rate deemed to be inclusive of cutting chases and making good disturbed surface). |
| 88 | M & L for point wiring for socket out let on 16 Amps independent Boards controlled by one, one way switch using 4.0 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, ncluding metal flush box and modular cover plate with frame of suitable size and 4.0 sqmm nominal cross sectioanl area multistranded copper conductor FRLS PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.Note: (i) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (Rate deemed to be inclusive of cutting chases and making good disturbed surface). |
| 89 | S&F Modular type switch 6 Amps 230V AC single module one way complete all as specified and as directed. |
| 90 | S&F Modular socket out let 3 pin 10 Amps shuttered type 230V AC 2 module complete all as specified and as directed. |
| 91 | S&F Modular socket out let 3 pin 16 Amps shuttered type 230V AC 2 module complete all as specified and as directed. |
| 92 | S&F Modular type switch 16 Amps 230V AC single module one way complete all as specified and as directed. |
| 93 | S&F Ceiling rose, surface bakelite, 65 x 50 mm,three terminals complete all as specified and directed. |
| 94 | S&F Modular type fan regulator Step type,100 Watt, one module/ two module, 230V AC complete all as specified and as directed. |
| 95 | Supply and fix modular bell push 10 Amp 230V AC complete all as specified and as directed. |
| 96 | Supply and fix Ding Dong bell, AC, 230 volts, single pole complete all as specified and as directed. |
| 97 | Supply & fixing lamp holder, PVC/polycarbonate type with back plate straight or angular suitable for batten fittings complete all as specified. |
| 98 | Supplying and fixing in repair two single core ,6 sqmm nominal cross sectional area multistranded copper conductor FR cable, PVC insulated unsheathed 1100 Volts grade drawing in and including nd including suitable size PVC conduit (ISI marked) concealed including 6 sqmm nominal cross sectional area multistranded copper conductor FR cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified. Note : Two run of 6 sqmm wire with one run of 6 sqmm and one run of casing capaing / conduit pipe shall be measured against one unit. |
| 99 | Supply and fixed 18 W LED light fitting wall mounted batten 4'ft , minimumm lumen output 100 lumen/Wat, extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 18 watt,6500K including necessary connection complete all as specified and directed. |
| 100 | Supply and fixed 10 W LED light fitting wall mounted batten 2'ft , minimumm lumen output 100 lumen/Wat, extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 09 watt,6500K including necessary connection complete all as specified and directed. |
| 101 | Supply and fixed security light fittings 30 watts, minimumm lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete including 25mm dia light grade GI bracket with nut bolt and clamp complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as directed. |
| 102 | Supply and fixed recessed mounted 2' x 2 ' LED luminaire 36 watts for grid ceiling minimumm lumen output 100 lumen/Watt, pre-treated CRCA frame powder coated with diffused Profied including necessary connection complete all as specified and directed. |
| 103 | Supply and fixed 12 W Surface panel mounted round LED downlight, aesthetically designed aluminium die-cast enclousers, with seperate replaceable constant current driver 12 watts, including necessary connection complete all as specified and directed. |
| 104 | Supply & fix in replacement of LED bulb 15 watt 6500 k complete all as specified and as directed. |
| 105 | Supply and fixing LED decorative wall light made up of high grade engineering plastic material suitable for LED 20W complete as per manufacturer's instructions all as specified and directed. |
| 106 | Supply and fixing profile lighting on surface of roof Smart LED Strip BLE MESH 5 m Roll light made up of high grade engineering plastic material complete as per manufacturer's instructions all as specified and directed. |
| 107 | Supply and fixed in repairs epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed. |
| 108 | Supply and fixed in repairs epoxy powder coated sheet metal enclosure for DBs, double door, Triple pole and neutral 415 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed. |
| 109 | Supply and fixed in repairs MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs including necessry connection complete all as specified and directed. |
| 110 | Supply and fixed in repairs MCB SPN 6-32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed. |
| 111 | Supply and fixed in repairs MCB TPN 63 Amps, 'C' series 10kA, 415 Volts and to be housed in DBs complete including necessry connection all as specified and directed. |
| 112 | Taking down of AC ceiling / exhaust fan of any sweep & any height and opening the fan and oiling, greasing and replacement of unserviceable accessories and servicing, complete overhauling and re-assembling and testing complete for efficient functioning and hanging it back in position including provn of 0.5 Sqmm copper flexible twin twisted cable (length not exceeding 0.5 metre) from ceiling rose to fan as directed by the Engr-in-Charge. |
| 113 | Taking down existing Geyser of any size and make upto 25 ltrs carefully, by diconnecting electrical and water pipe line connection and deposite at MES Yard/store for refixing. |
| 114 | Refixing of existing Geyser 25 ltrs as per above item by connecting electrical and water pipe line connection. |
| 115 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 300m complete all as specified and as directed. |
| 116 | Supply, laying / fixing / connecting, testing and commissioning of 16 Sqmm x 4 core LT under ground cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) all as directed by the Engr-in-Charge. |
| 117 | NOTES:1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 04, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysAug 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender