Defence Statutory Bodies & Commissions/Committees Closing in 16 days TDR #56592204

Tender For special Repair Of Transformer And Voltage Stabilizer Against Ber Eqpt At Baramulla Pattan Under Ge 969 Ews.

Issued by Statutory Bodies & Commissions/Committees · Baramulla, Jammu and Kashmir
Tender Value
34.43 Lakhs
Estimated cost
Bid Submission
08 Aug 2026
16 days left
EMD
68860
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Baramulla → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair Of Transformer And Voltage Stabilizer Against Ber Eqpt At Baramulla Pattan Under Ge 969 Ews.

BOQ

Name of Work:- SPL REPAIR OF TRANSFORMER AND VOLTAGE STABILIZER AGAINST BER EQPT AT BARAMULLA PATTAN UNDER GE 969 EWS.
Sl. No. Item Description
1Supply, Installation, Commissioning of transformer of capacity 400 KVA step down outdoor type Copper Wounded ONAN Cooling 11/0.433 KV (at no load) AC 3 Phase 50 Hz on secondary side double wounded oil immersed naturally all air cooled with external tubes/radiator, delta connected as on primary and star connected with neutral brought on secondary. The maximum temperature rise should not exceed 45 degree centigrade in oil and 50 degree centigrade in HV/LV winding when measured by the resistance method after continuous full load run in ambient temprature the transformer shall confirming to IS 2026, 1997 and comprising of following accessories :- Bd ser No-05
2(a) 01 No Cable end box on HV side consisting of with 03 Nos porcelain bushing with bushing rods and nuts washers and cable glands suitable for XLPE cable 3 Core 120 Sqmm including cable joint complete adopter box(b) 01 No cable end box on LV secondary side consisting of 04 Nos porcelain bushing with bushing rods and nuts washers and cable glands suitable for XLPE cable 3.5 Core 185 Sqmm including cable joint complete adopter box
3(c) Oil conservator with filter type drain valve and oil level gauge.(d) Dehydrating breather with first filling of dehydrating agent.(e) Explosive vent.(f) Thermometer Pocket.(g) Two earthing terminal on tank body to facilitate fixing of 32x6mm GI Strip.(h) One No thermometer dial type vapour pressure type having range 0-120 degree centigrade with maximum temprature indicator and re-setting device to maximum temprature including needle of temprature gauge max reading panted terminal.
4(j) Rating plate with terminal plate.(k) Oil drain filter valve.(l) Oil filling hole on top cover with plug.(m) Air release valve/plug.(n) 4 Nos plain solid cast steel detachable rollers.(o) Extra bushing for neutral out side the cable box providing independent earthing for neutral.(p) First fill of transformer oil confirming to relevant IS and tested upto 60KV dielectric strength.
5All as per item No. 1 here in before But transformer of 160 KVA capacity.Bd ser No.-5 PTN, complete all as specified and as directed.
6All as per item No. 1 here in before But transformer of 63 KVA capacity.Bd ser No.-12 bml, complete all as specified and as directed.
7Supply and Installation Voltage stabilizer Copper Wound for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 150 KVA all as specified . Bd Ser No.-06 PTN, complete all as specified and as directed.
8Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm, complete all as specified and as directed.
9Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core, complete all as specified and as directed.
10Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth,for foundations,laying of pipes etc not exceeding 10sqm on plan for mamholes etc and not exceeding 1.5 metre in depth and getting out in Soft/loose soil, complete all as specified and directed.
11Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25cm.in hard/dense soil, complete all as specified and as directed.
12Removing excavated material not exceeding 50mtr and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and as directed.
13Supply and laying of burnt clay building bricks, sub-classB (old size) Designnation 75 laid flat in tranches for cable protection with wide equal to length of brick, complete all as specified and as directed.
14M & L for dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15cm thick after laying the cable all as specified in clause 19.75 of MES schedule part-1 Note:-Sand shall be fine sand as specified for plastering.
15Supply and fix cable jointing kit for 1.1 KV grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3.5 core XLPE,armoured, Al conductor cable of size 70 sqmm to 95 sqmm, complete all as specified and as directed.
16Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE,armoured, Al conductor cable of size 50 sqmm to 95 sqmm, complete all as specified and as directed.
17M&L in repairs for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth strip 32x6mm (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is inclusive of necessary earth work, RFR and removal etc Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56592204
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 34.43 Lakhs
LAST DATE 08-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair Of Transformer And Voltage Stabilizer Against Ber Eqpt At Baramulla Pattan Under Ge 969 Ews.
Basic Detail
Tender No CA NO 969 WS- /2026-27
Bidding Type Tender
Location
City Baramulla
State Jammu and Kashmir
Key Dates
Publish Date 21 Jul 2026
Submission Date 08 Aug 2026
Open Date 10 Aug 2026
Finance
Tender Value 34.43 Lakhs
Tender Fee 500
EMD 68860
Exemption Available
Document List
976d5e96-83b1-4218-a360-346d8bf673fb.html
BOQ_873624.xls
TENDER.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Aug 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
html

976d5e96-83b1-4218-a360-346d8bf673fb.html

xls

BOQ_873624.xls

pdf

TENDER.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders