Tender For Annual Maintenance Contract For Repair/Maint Of Fire Alarm System Including Connecting Items At Afs Pathankot .
Tender Value
22 Lakhs
Estimated cost
Bid Submission
12 Aug 2026
18 days left
EMD
44000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pathankot → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Annual Maintenance Contract For Repair/Maint Of Fire Alarm System Including Connecting Items At Afs Pathankot .
BOQ
| Sl. No. | Item Description |
| 1 | Material and labour for periodical maintenance of fire alarm system by attending fault ,testing of system ,periodical checking of system,Chacking MCP,Hooter ,Smokedetector and connecting all items including testing on monthely basis in presence of users representative ,etc including attending system fault on emergency ,preventive function of fire alarm system installed at WSA-III AC I PLANT all technical bldgs complete as per existing conventional /addressable type make ,type Zone &loop etc main control panel comprising of the following complete all as specified and as directed:- (a) 8 to 12 Zone main control panel with zone card battery charger and 230Volt power unit. (b) ionisation type smoke detector ,heat detector ,response indicator ,manual call point and hooters etc. (c) All cable connections from main contral panel to items (d) Lead acid battery any capacity (e) electric hooter NOTE:-(i) Cost of minor spare parts repaced other than as given in BOQ herein after shall be deemed to be included in the quoted unit rate quoted by the contractor (ii) Testing kit (solo smoke and heat detector kit) wii be provided by the contractor for testing of system and report will be submitted to the Engg-in -charge |
| 2 | ALL as per Serial Item No-1 above but for WSA-III AC-II PLANT as per existing main contral panel with electric siren ,hooter etc. |
| 3 | ALL as per Serial Item No-1 above but for WSA-III AC -III PLANT as per existing main contral panel with electric siren ,hooter etc. |
| 4 | ALL as per Serial Item No-1 above but for WSA-III MATRA PLANT as per existing main contral panel with electric siren ,hooter etc. |
| 5 | ALL as per Serial Item No-1 above but for WSA-III HQ PLANT as per existing main contral panel with electric siren ,hooter etc. |
| 6 | ALL as per Serial Item No-1 above but for WSA-III ADM BLOCKas per existing main contral panel with electric siren ,hooter etc. |
| 7 | ALL as per Serial Item No-1 above but for WSA-II DB 8 PLANT as per existing main contral panel with electric siren ,hooter etc. |
| 8 | ALL as per Serial Item No-1 above but for WSA-II SPYDER-III PLANT as per existing main contral panel with electric siren ,hooter etc. |
| 9 | ALL as per Serial Item No-1 above but for SPYDER -II PLANT AT D LOOP AREA as per existing main contral panel with electric siren ,hooter etc. |
| 10 | ALL as per Serial Item No-1 above but for SPYDER -I PLANT AT TECH AREA as per existing main contral panel with electric siren ,hooter etc. |
| 11 | ALL as per Serial Item No-1 above but for SRE BLDGS as per existing main contral panel with electric siren ,hooter etc. |
| 12 | ALL as per Serial Item No-1 above but for GCA DISPLAY BLDGS as per existing main contral panel with electric siren ,hooter etc. |
| 13 | ALL as per Serial Item No-1 above but for 731 SU SATCOM as per existing main contral panel with electric siren ,hooter etc. |
| 14 | ALL as per Serial Item No-1 above but for BASE OFFICE as per existing main contral panel with electric siren ,hooter etc. |
| 15 | ALL as per Serial Item No-1 above but for RUNWAY 19 ENDS as per existing main contral panel with electric siren ,hooter etc. |
| 16 | ALL as per BOQ Serial Item No-1 above but for RUNWAY 01 ENDS as per existing main contral panel with electric siren ,hooter etc. |
| 17 | Taking down unserviceable conventional type alarm contral panel from existing position and supply ,installation ,testing and commissioning new microprocessor type fire alarm control panel of2/4 zone upto 8 Zone with 10 Amp power supply to work on single phase AC supply 50 HZ fabricated out of CRCA sheet with standard size as per OEM recommendation duly painted including wiring with suitable copper conductor cable from panel to floor level manual call point and upto smoke/heat detector if required all as specified and directed by engg-in-charge of MAKE:- Appolo/Honewell/AGANI/HOCHIK/AADHUNIK or equivalent as approved by Engg-in-Charge. |
| 18 | Taking down unserviceable conventional type alarm contral panel from existing position and supply ,installation ,testing and commissioning new microprocessor type fire alarm control panel of 12 zone upto 32 Zone with 32 Amp power supply to work on single phase AC supply 50 HZ fabricated out of CRCA sheet with standard size as per OEM recommendation duly painted including wiring with suitable copper conductor cable from panel to floor level manual call point and upto smoke/heat detector if required all as specified and directed by engg-in-charge of MAKE:- Appolo/Honewell/AGANI/HOCHIK/AADHUNIK or equivalent as approved by Engg-in-Charge. |
| 19 | Supply and fixing power Supply SMPS Suitable for Conventional /addressable Type fire alarm system working with 24 DC Volt 10 Amps power aupply all as specfied and directed. |
| 20 | Supply and fixing in repair with testing of Smoke Detector ,addressable /conventional type conforming to E- 54.7 standard od size 100mm dia ,height 56mm suitable to work on 24V DC(12V DC -28 V DC) fixed with LED made out of flame retardant plastic confirming to fire protection standard complete all as specified as directed ,with builtin LED and mounting base for Semi conventional Fire Alarm Panel of all above specified Zone MAKE:- Appolo/Honewell/AGANI/HOCHIK/AADHUNIK or equivalent as approved by Engg-in-Charge. |
| 21 | Supply and fixing in repair with testing of Heat Detector addressable /conventional type Operating at 54 degree to 57 degree celsius for Semi conventional Fire Alarm Panel of all above specified Zone complete all as specified and directed MAKE:- Appolo/Honewell/AGANI/HOCHIK/AADHUNIK or equivalent as approved by Engg-in-Charge. |
| 22 | Supply and fixing in repair with testing of Multi sensor Detector addressable /conventional type for Semi conventional Fire Alarm Panel of all above specified Zone complete all as specified and directed MAKE:- Appolo/Honewell/AGANI/HOCHIK/AADHUNIK or equivalent as approved by Engg-in-Charge. |
| 23 | Supply and fixing in rrepacement manual call point conventional/addressable and explosive proof type mounting type of standard size with alarm raising push button,plastic coated glass element weather proof suitable for outdoor type system od size 10/7 inch metal back box and suitable for conventional type fire alarm system etc complete all as specified and directed MAKE:- Appolo/Honewell/AGANI/HOCHIK/AADHUNIK or equivalent as approved by Engg-in-Charge. |
| 24 | Supply and fix in repacement Response indicator automatic reset type complete all as specfied and direected by engg-in-charge MAKE:- Appolo/Honewell/AGANI/HOCHIK/AADHUNIK or equivalent as approved by Engg-in-Charge. |
| 25 | Supply and fixing Addressable monitor module/control module including all fixing complete all as specfied and direected by engg-in-charge MAKE:- Appolo/Honewell/AGANI/HOCHIK/AADHUNIK or equivalent as approved by Engg-in-Charge. |
| 26 | Supply and fix in replacement lead acid battery 12v/7 AH Capacity (maintenance free) complete all as specified and directed |
| 27 | Supply and fixing in repais Transformer unit Suitable for addressable /conventional type for Semi conventional Fire Alarm Panel of all above specified Zone complete all as specified and directed MAKE:- Appolo/Honewell/AGANI/HOCHIK/AADHUNIK or equivalent as approved by Engg-in-Charge. |
| 28 | Supply and fixing in repair Zone Card/Power Supply Card Suitable for addressable /conventional type for Semi conventional Fire Alarm Panel of all above specified Zone complete all as specified and directed MAKE:- Appolo/Honewell/AGANI/HOCHIK/AADHUNIK or equivalent as approved by Engg-in-Charge. |
| 29 | Supply and fixing in repair with testing of fire alarm Sounders/Hooter /Sirens Electronic type horizontal single stage continous normal operations for atlest 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr sound output varaation of +5DB 1500 mtrs range for Semi conventional Fire Alarm Panel of all above specified Zone complete all as specified and directed |
| 30 | Supply and fixing Connecting Copper Cable 2 core 1.5 sqmm for Semi conventional Fire Alarm Panel to main bldgs of all above specified Zone complete all as specified and directed |
| 31 | Supply and fixing Connecting Copper Cable 4 core 1.5 sqmm for Semi conventional Fire Alarm Panel to main bldgs of all above specified Zone complete all as specified and directed |
| 32 | Supply and fixing Connecting Copper Cable 4/6 core 4 sqmm for Semi conventional Fire Alarm Panel to main bldgs of all above specified Zone complete all as specified and directed Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysAug 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓