Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #56592131

Tender For Annual Maintenance Contract For Repair/Maint Of Fire Alarm System Including Connecting Items At Afs Pathankot .

Issued by Statutory Bodies & Commissions/Committees · Pathankot, Punjab
Tender Value
22 Lakhs
Estimated cost
Bid Submission
12 Aug 2026
18 days left
EMD
44000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pathankot → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Annual Maintenance Contract For Repair/Maint Of Fire Alarm System Including Connecting Items At Afs Pathankot .

BOQ

Name of Work:- Annual maint Contract for Repair/Maint of Fire Alarm System including connecting Items at AFS Pathankot .
Sl. No. Item Description
1Material and labour for periodical maintenance of fire alarm system by attending fault ,testing of system ,periodical checking of system,Chacking MCP,Hooter ,Smokedetector and connecting all items including testing on monthely basis in presence of users representative ,etc including attending system fault on emergency ,preventive function of fire alarm system installed at WSA-III AC I PLANT all technical bldgs complete as per existing conventional /addressable type make ,type Zone &loop etc main control panel comprising of the following complete all as specified and as directed:- (a) 8 to 12 Zone main control panel with zone card battery charger and 230Volt power unit. (b) ionisation type smoke detector ,heat detector ,response indicator ,manual call point and hooters etc. (c) All cable connections from main contral panel to items (d) Lead acid battery any capacity (e) electric hooter NOTE:-(i) Cost of minor spare parts repaced other than as given in BOQ herein after shall be deemed to be included in the quoted unit rate quoted by the contractor (ii) Testing kit (solo smoke and heat detector kit) wii be provided by the contractor for testing of system and report will be submitted to the Engg-in -charge
2ALL as per Serial Item No-1 above but for WSA-III AC-II PLANT as per existing main contral panel with electric siren ,hooter etc.
3ALL as per Serial Item No-1 above but for WSA-III AC -III PLANT as per existing main contral panel with electric siren ,hooter etc.
4ALL as per Serial Item No-1 above but for WSA-III MATRA PLANT as per existing main contral panel with electric siren ,hooter etc.
5ALL as per Serial Item No-1 above but for WSA-III HQ PLANT as per existing main contral panel with electric siren ,hooter etc.
6ALL as per Serial Item No-1 above but for WSA-III ADM BLOCKas per existing main contral panel with electric siren ,hooter etc.
7ALL as per Serial Item No-1 above but for WSA-II DB 8 PLANT as per existing main contral panel with electric siren ,hooter etc.
8ALL as per Serial Item No-1 above but for WSA-II SPYDER-III PLANT as per existing main contral panel with electric siren ,hooter etc.
9ALL as per Serial Item No-1 above but for SPYDER -II PLANT AT D LOOP AREA as per existing main contral panel with electric siren ,hooter etc.
10ALL as per Serial Item No-1 above but for SPYDER -I PLANT AT TECH AREA as per existing main contral panel with electric siren ,hooter etc.
11ALL as per Serial Item No-1 above but for SRE BLDGS as per existing main contral panel with electric siren ,hooter etc.
12ALL as per Serial Item No-1 above but for GCA DISPLAY BLDGS as per existing main contral panel with electric siren ,hooter etc.
13ALL as per Serial Item No-1 above but for 731 SU SATCOM as per existing main contral panel with electric siren ,hooter etc.
14ALL as per Serial Item No-1 above but for BASE OFFICE as per existing main contral panel with electric siren ,hooter etc.
15ALL as per Serial Item No-1 above but for RUNWAY 19 ENDS as per existing main contral panel with electric siren ,hooter etc.
16ALL as per BOQ Serial Item No-1 above but for RUNWAY 01 ENDS as per existing main contral panel with electric siren ,hooter etc.
17Taking down unserviceable conventional type alarm contral panel from existing position and supply ,installation ,testing and commissioning new microprocessor type fire alarm control panel of2/4 zone upto 8 Zone with 10 Amp power supply to work on single phase AC supply 50 HZ fabricated out of CRCA sheet with standard size as per OEM recommendation duly painted including wiring with suitable copper conductor cable from panel to floor level manual call point and upto smoke/heat detector if required all as specified and directed by engg-in-charge of MAKE:- Appolo/Honewell/AGANI/HOCHIK/AADHUNIK or equivalent as approved by Engg-in-Charge.
18Taking down unserviceable conventional type alarm contral panel from existing position and supply ,installation ,testing and commissioning new microprocessor type fire alarm control panel of 12 zone upto 32 Zone with 32 Amp power supply to work on single phase AC supply 50 HZ fabricated out of CRCA sheet with standard size as per OEM recommendation duly painted including wiring with suitable copper conductor cable from panel to floor level manual call point and upto smoke/heat detector if required all as specified and directed by engg-in-charge of MAKE:- Appolo/Honewell/AGANI/HOCHIK/AADHUNIK or equivalent as approved by Engg-in-Charge.
19Supply and fixing power Supply SMPS Suitable for Conventional /addressable Type fire alarm system working with 24 DC Volt 10 Amps power aupply all as specfied and directed.
20Supply and fixing in repair with testing of Smoke Detector ,addressable /conventional type conforming to E- 54.7 standard od size 100mm dia ,height 56mm suitable to work on 24V DC(12V DC -28 V DC) fixed with LED made out of flame retardant plastic confirming to fire protection standard complete all as specified as directed ,with builtin LED and mounting base for Semi conventional Fire Alarm Panel of all above specified Zone MAKE:- Appolo/Honewell/AGANI/HOCHIK/AADHUNIK or equivalent as approved by Engg-in-Charge.
21Supply and fixing in repair with testing of Heat Detector addressable /conventional type Operating at 54 degree to 57 degree celsius for Semi conventional Fire Alarm Panel of all above specified Zone complete all as specified and directed MAKE:- Appolo/Honewell/AGANI/HOCHIK/AADHUNIK or equivalent as approved by Engg-in-Charge.
22Supply and fixing in repair with testing of Multi sensor Detector addressable /conventional type for Semi conventional Fire Alarm Panel of all above specified Zone complete all as specified and directed MAKE:- Appolo/Honewell/AGANI/HOCHIK/AADHUNIK or equivalent as approved by Engg-in-Charge.
23Supply and fixing in rrepacement manual call point conventional/addressable and explosive proof type mounting type of standard size with alarm raising push button,plastic coated glass element weather proof suitable for outdoor type system od size 10/7 inch metal back box and suitable for conventional type fire alarm system etc complete all as specified and directed MAKE:- Appolo/Honewell/AGANI/HOCHIK/AADHUNIK or equivalent as approved by Engg-in-Charge.
24Supply and fix in repacement Response indicator automatic reset type complete all as specfied and direected by engg-in-charge MAKE:- Appolo/Honewell/AGANI/HOCHIK/AADHUNIK or equivalent as approved by Engg-in-Charge.
25Supply and fixing Addressable monitor module/control module including all fixing complete all as specfied and direected by engg-in-charge MAKE:- Appolo/Honewell/AGANI/HOCHIK/AADHUNIK or equivalent as approved by Engg-in-Charge.
26Supply and fix in replacement lead acid battery 12v/7 AH Capacity (maintenance free) complete all as specified and directed
27Supply and fixing in repais Transformer unit Suitable for addressable /conventional type for Semi conventional Fire Alarm Panel of all above specified Zone complete all as specified and directed MAKE:- Appolo/Honewell/AGANI/HOCHIK/AADHUNIK or equivalent as approved by Engg-in-Charge.
28Supply and fixing in repair Zone Card/Power Supply Card Suitable for addressable /conventional type for Semi conventional Fire Alarm Panel of all above specified Zone complete all as specified and directed MAKE:- Appolo/Honewell/AGANI/HOCHIK/AADHUNIK or equivalent as approved by Engg-in-Charge.
29Supply and fixing in repair with testing of fire alarm Sounders/Hooter /Sirens Electronic type horizontal single stage continous normal operations for atlest 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr sound output varaation of +5DB 1500 mtrs range for Semi conventional Fire Alarm Panel of all above specified Zone complete all as specified and directed
30Supply and fixing Connecting Copper Cable 2 core 1.5 sqmm for Semi conventional Fire Alarm Panel to main bldgs of all above specified Zone complete all as specified and directed
31Supply and fixing Connecting Copper Cable 4 core 1.5 sqmm for Semi conventional Fire Alarm Panel to main bldgs of all above specified Zone complete all as specified and directed
32Supply and fixing Connecting Copper Cable 4/6 core 4 sqmm for Semi conventional Fire Alarm Panel to main bldgs of all above specified Zone complete all as specified and directed Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56592131
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 22 Lakhs
LAST DATE 12-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Annual Maintenance Contract For Repair/Maint Of Fire Alarm System Including Connecting Items At Afs Pathankot .
Basic Detail
Tender No GE/PAF-68/2026-27
Bidding Type Tender
Location
City Pathankot
State Punjab
Key Dates
Publish Date 22 Jul 2026
Submission Date 12 Aug 2026
Open Date 14 Aug 2026
Finance
Tender Value 22 Lakhs
Tender Fee 500
EMD 44000
Exemption Available
Document List
557b5052-d9a5-4a2c-a6bc-41d1637173e0.html
BOQ_873735.xls
Tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Aug 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
html

557b5052-d9a5-4a2c-a6bc-41d1637173e0.html

xls

BOQ_873735.xls

pdf

Tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders