Tender For special Repair To Bldg No 86/F-1, 86/F-2, 86/F-3, 86/F-4 (Other Rank Md Accn) And special Repair Of Drainage From Offrs Mess And Jcos Club To Ration Stand Otm Accn And Jcos/Or Md Accn Of 23 Weu At Chaubattia Under Ge Ranikhet
Tender Overview
Project Description
Tender for special Repair To Bldg No 86/F-1, 86/F-2, 86/F-3, 86/F-4 (Other Rank Md Accn) And special Repair Of Drainage From Offrs Mess And Jcos Club To Ration Stand Otm Accn And Jcos/Or Md Accn Of 23 Weu At Chaubattia Under Ge Ranikhet
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.complete all as directed. |
| 2 | M & L for screed bed or bedding layer 15mm thick in cement mortar(1:6) for laying floor finishes Complete all as specified and directed. |
| 3 | M & L for non skid ceramic coloured /printed tiles 7 to 8 mm thick (square / Rectangular)area of each tiles exceeding 0.18 sqm but not exc 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match the tiles. |
| 4 | All as per item no 3 for dado /skirting Complete all as specified and directed. |
| 5 | M & L for non skid ceramic coloured /printed tiles 7 to 8 mm thick (square / Rectangular)area of each tiles exceeding 0.11 sqm but not exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match the tiles. |
| 6 | M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:3 for backing of Dado/ Skirting & Vertical Tiles. |
| 7 | M & L for glazed ceramic coloured / printed tiles 300mm x 450mmX7mm thick, on vertical surfaces set and jointed in neat cement slurry and pointed in white/coloured cement to match the tiles, complete all as specified and as directed. |
| 8 | M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite inluding screed bed in cement plaster 1:4 or bedding layer 20 mm thick complete all as specified & directed by Engr-in-charge. |
| 9 | Demolition of Reinforced cement concrete of any description and in any position not otherwise specifically provided for. (reinforcement cut as required to facilitate demolition) |
| 10 | M&L RCC Type B1 1:2:4 (20.0mm graded aggregate)for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like |
| 11 | Formwork to rough finished surface of concrete soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) |
| 12 | M & L for TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 13 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness.(below or above ground level) Complete all as specified and directed. |
| 14 | M & L for 75 mm thick PCC (1:3:6) type C2 using 40mm graded stone aggregate as in plinth protection finishing the surface even and smooth without using extra cement Complete all as specified and directed. |
| 15 | Surface channel in concrete 1:3:6 (40 mm graded aggregate) for drain complete all as specified and directed. |
| 16 | Extra for forming fair finished drain or channel 30 cm inner girth in cement complete all as specified and directed.concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc.All as specified and directed. |
| 17 | Taking down cement plaster of any description on brick or stone walls, etc. including racking out joints, hacking for key, scrubbing down with water etc.&removing rubbish to a disance not exc 250m Complete all as specified and directed. |
| 18 | M&L for rendering 10 mm thick in cement mortar 1:6 on faces of brick work or concrete surfaces finished even and smooth without using extra cement including mixing of water proofing compound of approved make complete all as specified. |
| 19 | Supply only integral water proofing compound complete all as specified & directed. |
| 20 | M&L for rendering 15 mm thick readymade plaster on inner/outer walls with Ultra Tech READIPLAST by adding 17-19% of potable water by weight of material. for thickness above 15mm, it is recommended to be applied in multiple layers. Ready mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the Compressive strength @ 28 days- 10-12 Mpa/Bulk density-1500-1600 kg/cum. Note : The rate quoted by the contractor shall include cleaning of surface, application as per instruction and scaffolding upto 10 mtr height, all as specified and directed. |
| 21 | M&L for preparation of newly plastered surfaces of wall and applying two coat of oil bound distemper over a coat of primer complete all as specified and directed |
| 22 | M&L for preparation of newly plastered surfaces of wall and applying two coats of weather proof exterior emulsion over a coat of primer complete all as specified and directed. |
| 23 | M&L for preparation of old decorated surfaces by washing, rubbing down and stopping of painted , plastered or un-plastered surfaces of walls and applying one coat of oil bound distemper white or tinted complete all as specified and directed. |
| 24 | M&L for preparation of old decorated surfaces by washing, rubbing down and stopping of painted , plastered or un-plastered surfaces of walls and applying one coat of weather proof exterior emulsion complete all as specified and directed. |
| 25 | M&L for 3 mm thick applying a layer of JK/ Birla putty on wall surfaces including cornics etc for proper levelling of plaster complete all as specified and directed. |
| 26 | Demolition brick work or stone/ boulder masonery built in cement mortar including all quoins , pillars etc |
| 27 | M&L precast cement concrete 1:3:6 type C1(using 20 mm graded stone agg) as in block masonry with solid blocks exc 10 cm in width and set in cement mortar 1:6 complete all as specified and directed. |
| 28 | M&L for brick work using sub class ‘B’ old size bricks, straight or curved on plan exceeding 6m mean radius, built in CM (1:6) complete al as specified |
| 29 | M&L for brick work using sub class ‘B’ old size bricks, straight or curved on plan to any radius in half brick thick walls, built in CM (1:4) complete all as specified and directed. |
| 30 | M & L for 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6, finished even & smooth complete all as specified. |
| 31 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) not exc 1.5 sqm each complete all as specifed & directed. |
| 32 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm but not exc 4.0 Sqm each complete all as specifed & directed. |
| 33 | M&L for 2nd class hard wood plain, solid, straight chowkats and frames, wrought, frame rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 34 | S & F MS framed work such as grills, gratings, etc., with end of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe 190-0 or Fe-165-0. |
| 35 | S & F 35 mm thick 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed. |
| 36 | S&F 30 mm thick 2nd class hardwood glazed and skeleton window shutters rebated and prepared to receive glass, gauge etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc; sizes of members of shutters as specified in SSR Part I, Section 8, Clause 8.20(b); supplied and fitted in chowkats , but divided into squares, with plain, chamfered or roun ded, mitred and rebated sash bars, any numbers complete complete all as specified and directed. |
| 37 | Factory made single extruded WPC (wood polymer Composite) solid door/ window/ Ceosetory window & other Frames/ Chowkhat of size 45 x 70 mm comprising of PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wwod powder/ rick husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms ) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded stat headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N / mm 2 and resistance to spread of flame of Class A catogory with property of being termite/ borer proof, water / moisture proof and fire retardant and fixed in position with MS hold fast/lugs / SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). |
| 38 | Factory made single extruded WPC (wood polymer Composite) solid plain flush door shutter of 35 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/ cum and screw withdrwal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N mm2 modulus of elasticity 850 N / mm2 and resistance to spread of flame of Class A catogary with property of being termite/ borer proof, water/ moisture proof and fire retardanat and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, all as per direction of Engineer-In-Charge (Note:- stainless steel butt hinges and necessary SS screws shall be paid separately. |
| 39 | S & F butt hinges, medium weight, Mild steel and fixed, size of hinges 75mm complete all as specified and directed. |
| 40 | S & F butt hinges, medium weight, Mild steel and fixed, size of hinges 100mm complete all as specified and directed. |
| 41 | Supply and fix 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and directed. |
| 42 | S & F 100 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 43 | S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 44 | S & F 100 mm long Aluminium, anodised, barrel tower bolts of extruded section |
| 45 | S & F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section |
| 46 | S & F floor door stopper of chromium plated body with rubber shoe fixed in door, overall length of cover plate 140 mm all as specified and directed. |
| 47 | S&F MS 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified & directed. |
| 48 | Dismantling of boarding , any description fixed in any position with screws complete all as specified and directed. |
| 49 | M&L for veneered particle board 18/19 mm, solid core, interior grade, with decorative face veneers one face fixed in cup board shutter/shelves complete all as specified & directed. |
| 50 | Supply and fix Continuous (piano) hinges width 30 mm mild steel , bright finish or eletrogalvanised complete all as specified |
| 51 | S & F 3 mm thick Sheet glass, figured , pin headed and glazing with beadings in square not exceeding 0.5 Sqm in each pane complete all as specified and directed. |
| 52 | S & F 3 mm thick Sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed. |
| 53 | S & F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with Stainless steel wire staples. |
| 54 | M & L for painting to new wood and wood based surfaces of any description, over 10 cm in width or girth, not otherwise described with two coats of synthetic enamel paint over a coat of pink primer including preparation of surfaces. |
| 55 | Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store. |
| 56 | S&F GI water tubing of 15mm dia ,medium grade conforming to IS-1239(Part -1) including all fittings such as bends,tees,short pieces,connectors,elbows,reducers,union dockets etc & fixed to walls,ceilings, & laid on floors complete all as specified and directed. |
| 57 | Refixing of old 15 mm bore steel tubing and connections in new or old position (walls, ceiling, floors etc.) |
| 58 | S&F in repair stop valves, cast copper alloy, fancy type chromium plated , screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore dia of pipe. |
| 59 | S & F in repair vitreous china wash basin, white flat back size 550X400 mm, (flat back or angle back type) including brackets and including cutting for and pinning in ends of brackets or erecting stand, fixed in repairs. |
| 60 | S & F in repair 15 mm bore Fancy type pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed. |
| 61 | S&F 32mm dia waste fittings, brass, chromium plated for glazed ware sinks, basins, etc with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed. |
| 62 | S & F in repair bib taps, cast copper alloy, 15 mm dia, Chromium Plated, fancy type with crutch or butterfly handle, screwed down for iron pipe and fixed etc complete all as specified. |
| 63 | S& F in repair Vitreous china premium/ 1st quality wash down water closet EWC white/ ivory/off white (closed pattern incl all necessary accessories like rag bolts/ gel gasket etc. (excluding flushing cistern & flush pipe) complete in all respect all as specified. |
| 64 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified |
| 65 | S&F Cast iron Traps 100 mm P or S with long arm all as specified and directed |
| 66 | S & F in repairs 10 Liters capacity, PVC Valve less, Syphonic action type, low level flushing cistern, white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia including brackets and connections to pipe complete all as specified and as directed. |
| 67 | S&F in repair 600mmx450mm bevelled edge looking mirror and fixed to wooden plug with CP brass screws and cup washers complete all as apecified & directed |
| 68 | S&F 75mm dia Cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B1 complete all as specified and directed. |
| 69 | S&F in repair brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and directed. |
| 70 | S&F in repair chromium plated Soap dish fixed to plug with chormium plated brass screws all as specified and directed. |
| 71 | S&F in repair sink with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 72 | S&F in repair stainless steel wall mounted plate rack of size 780x760x240mm, made from the stainless steel sheet having thickness 1 mm and weight not less than 7.50 Kg, design & pattern as approved by GE, having sufficient space for placing crockeries, fixed on wall with rawl plug & screws, complete all as specified and directed |
| 73 | S&F in repairs Chromium plated shower rose 125 mm swivel type |
| 74 | S&F in repair 20mm Dia Aluminium alloy anodised curtain rod decorative fancy type with brackets complete all as specified & directed. |
| 75 | S&F in repair PVC connections 15mm dia , 450mm long, , with PTMT nuts & washers at both ends complete all as specified & directed. |
| 76 | Dismatling PVC Water tank Exc 250 & n exc 500 ltr and removing from site as specified and directed |
| 77 | S & F Rotational moulded PVC water storage tanks 500 Ltrs capcity three layer (cylindrical vertical with closed top) hoissted and fixed in position all as specified |
| 78 | S and F Ball brass valve 20 mm dia high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 79 | Dismantaling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 80 | S&F Pre-painted galvaLume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strenth of 550 Mpa as in roof covering / clading to waall , fixed self tapping screws complete all as specified and directed. |
| 81 | S&F Pre-painted galvatume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strenth of 550 Mpa as in roof covering / clading to waall , fixed self tapping screws complete all as specified and directed. |
| 82 | M&l for Dismatling timber scantling 40 sqcm and above in any position ,unframed work complete all as specified and directed |
| 83 | M&L second class hard wood timber in scantling clean sawn any description complete all as specified and directed. |
| 84 | Dismantling of wall and ceiling boards (fiber, pulp, insulation etc,) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed. |
| 85 | S & F for Aluminium anodised snap grid frame work for false ceiling comprising of following section for making partitions of 605 X 605 mm size fixed to walls with rawl plugs and screws and hang to roof with s 6 mm dia. G.I. (upto1200mm length) adjusting levelfixed to roof slabs by means ofceilling cleats made out of G.I.flat 40 x 3 mm size 60mm longand expansion hold fasteners12.5mm dia. 40mm long complete all as specified. size of main tee shall be :-(i)36.5mmx25mmx1.4mm thick, Weighing 0.24Kg/Rm(ii)Cross Tee 23.5mmx36.4mmx1.4mm thick Weighing 0.191 Kg/Rm and (iii)Wall angle 40mmx25mmx2mm thick. Weighing 0.36 Kg/Rm |
| 86 | S & F 4 mm thick non asbestos fiber designer ceiling (E-board classic) board / tiles for insulation and accoustic purpose, 600 X 600 mm size fixed in ceiling with and including dusting of surface complete all as specified and directed |
| 87 | S&F 6mm thick plwood as in ceiling, graded BWR, type BB complete all as specified & directed. |
| 88 | S & F for powder coated 0.55 mm thick GI ceiling grid system fixed to walls with rawl plugs and screws and hang to roof members with 2 mm dia GI wire complete all as specified and directed:- |
| 89 | S & F 6 mm thick PVC seamless ceiling for insulation and accoustic purpose fixed on snap grid as in ceiling and complete all as specified and directed MAKE- Sintex/Rajshree or equivalent as approved by GE |
| 90 | Supplying and laying APP based modified water proofing polymeric membrane reinforced with non woven polyester fabric matt (weight not less than 150 gram/sqm) of minimum 3mm thick, weight not less than 3 Kg/sqm, laid over & including 15 mm thick rendering in cement mortar 1:4 on concrete surfaces, finished the surfaces even and smooth including mixing of water proofing compound @ 3% by weight of cement over a bituminous shalitex primer @ 0.30 Kg/sqm evenly over a coat of hot bitumen 85/25 @ 1.2 Kg/sqm. The membrane shall be unrolled and bonded completely to the substrate (with overlap of 100mm on the transverse direction and 75mm on longitudinal direction and sealed by thermos fused torch) and the overlaps sealed / fused by thermos fused torch as per manufacturer instructions. A coat of non reflective bituminous aluminium paint @ 0.150 Kg/ Sqm, complete all as specified and as directedNote :- Water proofing compound shall be measured & paid separately under respective items of BOQ |
| 91 | M&L For 100mm Thick Cement concrete type D-2 1:4:8 (using 40 mm graded stone aggegate ) as in sub base course complete all as specified and directed. |
| 92 | M & L for cement concrete chequered tiles, 200*200*25 mm thick with grey cement and pigment as in floor, footpath, set and jointed in neat cement slurry and pointed with coloured cement to match the shade incl 15 mm thick Screed bed or bedding layer in cement mortar (1:4) on floor complete all as specified and directed |
| 93 | Demolition brick work or stone/ boulder masonery built in cement mortar including all quoins , pillars for ashlar facings,dressed stonework, precast concrete articles and precast concret block walling etc complete all as specified and directed. |
| 94 | M&L precast cement concrete 1:3:6 type C1(using 20 mm graded stone agg) as in block masonry with solid blocks exc 10 cm in width and set in cement mortar 1:6 complete all as specified and directed. |
| 95 | Excavation in trenches n exc 1.5m wide & n exc 1.5m in depth in hard/dense soil for foundation etc or for manholes, shafts etc n exc 10 sqm on plan and getting out complete all as specified and directed. |
| 96 | Demolition and breaking up drain pipes (SWG, AC or RCC) set in cement mortar incl cement concrete bedding hunching etc and removing from site to a distance n exc 50m as directed all as specified and directed. |
| 97 | M & L for cement conc 1:4:8 type D2 using 40mm graded crushed stone agg bed to drain pipes including packing under and hunching against the sides of pipes after they are laid and tested 150mm bore pipe complete all as specified and directed |
| 98 | M & L for 150mm bore salt glazed stoneware drain pipes grade A laid in trenches and jointed in CM 1:1 with spun yarn complete all as specified and directed |
| 99 | M & L Returing , filling in including spreading , levelling watering and well ramming in layers not exc 25cm as in hard/dense soil complete all as specified. |
| 100 | M & L Removing excavated material exc. 250m but n' exc 500m and depositing where directed as in soil complete all as aspecified and directed. |
| 101 | Dismantling stone slabs and tiles of any description and thickness in floors aprons etc. laid dry or laid dry pointed. |
| 102 | Demolition of precast concrete block walling etc. |
| 103 | Taking down cast iron traps 100 & 75 mm size P or S including grating etc. |
| 104 | Dismantling Old existing APP Membrane any thickness in any position |
| 105 | M &L For Type 1:3:6 Type C1 20 mm graded aggregate , in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 106 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished smooth and even without using extra cement complete all as specified & directed. |
| 107 | M & L PCC 1:2:4 type B1 using 20mm graded stone agg as in precast cover slab for main holes, drains, channels etc set in cement mortar 1:4 including necessary from work all as specified and directed |
| 108 | S & F MS steel TMT bars 10mm dia and over cut to length bent to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips, quality conforming to IS 1786-1985 complete all as specified and directed |
| 109 | Formwork to rough finished surfaces of edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 5cm but n exc 10cm wide complete all as specified and directed |
| 110 | Taking down carefully Aluminium/copper wiring of any size (for light, fan, socket or power etc complete) ( fittings such as switches, sockets, ceiling roses, pendent holders regulators, tube lights etc to be measured and paid separately) and making good disturbed surfaces of wall, roof etc to match with existing surface complete all as specified and directed. |
| 111 | M & L point wiring for Modular fittings for one light point/ fan/ bell/ 5Amps socket out let (independent)point controlled by one, one way switch with 1.5 sqmm size, PVC insulated and unsheathed 1100volts grade, single core stranded (multistrand) copper conductor (FR-LSH) PVC cable drawn into & including medium grade PVC conduit (not less than 20mm outer dia )with all fittings and accessories fixed concealed (including chase cutting in brick/ stone masonry walls for fixing conduit and plastering and whitewash/colouring the external surface and matching the same with existing surface) incl modular metal flush box for mounting modular fittings and covered with modular cover plate with frame and cup washers including one continuous run of PVC insulated (green colour) 1.5 Sqmm multistranded copper conductor cable earth wire and connected to earth dolly complete all as specified and directed (a) One light/One fan/one bell point controlled by one modular switch |
| 112 | One modular socket outlet 3 pin 6 amps controlled by one switch on same board. |
| 113 | One modular socket outlet 3 pin 6 amps controlled by one switch on independent board. |
| 114 | All as per item No 2 herein before but wiring with 2.5 sqmm copper wire (FRLS) PVC and 2.5 sqmm earth wire for modular socket outlet 5 pin 16 amps on independent board. |
| 115 | Supply and fix modular type switch single pole, one way 6 Amp complete all as specified and directed. |
| 116 | Supply and fix socket out let multi 5 pin, 6 Amps, modular type complete all as specified and directed. |
| 117 | Supply and fix switch modular type single pole, one way 16 Amp complete all as specified and directed. |
| 118 | Supply and fix socket out let 2 in1,3 pin, 6 and 16 Amp, modular type complete all as specified and directed. |
| 119 | S&F in replacement ceiling rose, PVC/ Poly carbonate,isolated body three terminal complete all as specified and directed. |
| 120 | S & F in replacement lamp holder angle type PVC/Poly carbonate type insulated body with back plate suitable for batten/wall fitting complete all as specified and directed. |
| 121 | Supply and fix In replacement High quality LED T8 indoor batten tube light 20 Watt with aluminium extrusion in D shaped have large diameter for increased convection heat transfer incl one LED PC tube rod and driver, internaly pre wired of 1.5 sqmm twin twisted flexible cable all as specified & directed. |
| 122 | S&F in replacement MCB SP, 240 volts,AC C curve, 10 KA 6 to 32 Amps complete all as specified and directed |
| 123 | S&F in replacement MCB SPN , 240 volts,AC B curve, 10 KA 40 Amps complete all as specified and directed |
| 124 | S & F in replacement MCB TPN , 415 volts, AC C curve, 10 KA 100 Amps complete all as specified and directed |
| 125 | Supply & Fixing of non metallic PVC conduit 25 mm exclusive of boxes but includinf of all tees,bends,elbows, reducers,bell mouth tube ends and fixing accessories such as couplers,lock nuts,saddles, pipe hooks etc. concealed in wall ceiling floor etc for television/DTH/telephone/Data cable complete all as specified and directed. |
| 126 | S& F socket outlet for TV/Video/audio device modular type with inner and outer modular plate type, specially built for wall/high mounted TV and inc pressed steel/metal flush box concealed complete all as specified and directed. |
| 127 | Supply and fix in replacement LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete. all as specified and directed. |
| 128 | S&F in replacement sheet metal enclusure for DBs(double door type) single pole and neutral 8 way including blanking platge as required with 200 Amps rated bus bar, 240 volts fixed complete all as specified and directed . |
| 129 | S&F in replacement sheet metal enclusure for DBs(double door type) Triple pole and neutral 4 way including blacking platge as required with 200 Amps rated bus bar, 415 volts fixed complete all as specified and directed . |
| 130 | S & F in replacement LED bulk head fitting, 1 x 10 watt with PDC aluminium housing and milky diffuser including LED light driver holder, complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230 Volts, 50 Hz complete all as specified and directed. |
| 131 | S&F in replacement sub main wiring with two single core( FR-LSH ) PVC insulated and sheathed 1100 Volts grade, 6 Sqmm size cables, PVC insulated stranded copper conductor fixed in PVC conduite pipe 25mm dia with all accessories and one continuous run of 6.0 Sqmm copper conductor PVC complete all as specified and directed (Note :- Two single core cables along with earth wire and conduit shall be measured as one unit length). |
| 132 | S&F in replacement for earthing complete with galvanised steel, earth plate electrode 600x600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs below ground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 15mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed.Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 15mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost. |
| 133 | S & F in replacement call bell ding dong AC, 230V single pole fixed over with and including sunk spressed steel box of size 175mmx100mm with 3mm thick plastic laminated backalite shut cover fixed with brass screw complete all as specified and directed, |
| 134 | S&F modular bell push, 6 Amp 1 module complete all as specified and directed. |
| 135 | S& F LED Bulb of 9 watt as specified |
| 136 | Supply and fix in replacement LED light fitting Mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with two core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 137 | Supply, laying and testing cable XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 core. |
| 138 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of underground cable and getting out in any type of soil complete all as directed by the Engineer-in-Charge |
| 139 | Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cms. thick in soft / loose soil complete all as specified and directed by Engr -in -charge . |
| 140 | Removal of surplus soil not exceeding 50 Mtr and depositing where directs at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engr-in-Charge. |
| 141 | M&L for sand cushioning in trenches spreading and consolidation 8cm thick before laying the cable & 15 cm of sand after laying the cable complete all as specified |
| 142 | M&L for laying of bricks well burnt sub class ‘B’ (old pattern) laid flat for cable protection width equal to the lengrth of brick complete all as specified . |
| 143 | M & L galvanised steel water tubing 'light grade' 40 mm bore with all fittings laid under the roads, drains, culverts and fixed on poles etc complete all as specified and directed . Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 27 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 34 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender