Tender For Two Yearly Repairing & Maintenance Work Of Air Conditioner At Head Office Bldg. Ward Offices Nagar Bhavan, Garden, School, Library In Mbmc Area. (Fully Comperensive Manner) (Panel System)
Tender Overview
Project Description
Tender for Two Yearly Repairing & Maintenance Work Of Air Conditioner At Head Office Bldg. Ward Offices Nagar Bhavan, Garden, School, Library In Mbmc Area. (Fully Comperensive Manner) (Panel System)
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 28-Jul-2026 | Date Corrigendum | Date | 21-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Description |
| 2 | ITEM NO. 1 (CSR 3-10-1)Providing servicing of 1/1.5/2/3 TR capacity split/window airconditioning unit complete with all necessary material. Job includes checking of performance of unit, cleaning of filters of indoor unit, cleaning of outdoor unit with blower, checking of electrical connection of indoor as well as outdoor unit and submitting report to Engineer incharge |
| 3 | ITEM NO. 2 (CSR 3-10-2)Providing annual comprehensive maintenance contract for 1 TR split/window air conditioning unit complete as per terms and conditions. Job includes 1) quarterly servicing 2) on call repair 3) replacement of all spares within 24 hours 4) sending standby manpower for VIP movement. The job excludes sheet metal work and plastic material. |
| 4 | ITEM NO. 3 (CSR 3-10-3)Providing annual comprehensive maintenance contract for 1.5 TR split/window air conditioning unit complete as per terms and conditions. Job includes 1) quarterly servicing 2) on call repair 3) replacement of all spares within 24 hours 4) sending standby manpower for VIP movement. The job exclude sheetmetal work and plastic material. |
| 5 | ITEM NO. 4 (CSR 3-10-4)Providing annual comprehensive maintenance contract for 2 TR split/window air conditioning unit complete as per terms and conditions. Job includes 1) quarterly servicing 2) on call repair 3) replacement of all spares within 24 hours 4) sending standby manpower for VIP movement. The job exclude sheetmetal work and plastic material. |
| 6 | ITEM NO. 5 (CSR 3-10-5)Providing annual comprehensive maintenance contract for 3TR to 4.5 TR split/tower/window air conditioning unit complete as per terms and conditions. Job includes 1) quarterly servicing 2) on call repair 3) replacement of all spares within 24 hours 4) sending standby manpower for VIP movement. The job exclude sheet metal work and plastic material |
| 7 | Item No:6 Monthly Servicing and visiting for complete checking 5.0 TR Ductable Air Conditioner Monthly servicing 2) on call repair 3) replacement of all spares within 24 hours 4) sending standby manpower for VIP movement.5) The job include sheet metal work and plastic material with Electrical Parts, Compressor and essential Material.6)Including Gas Charging,Fan Motor, Condenser Coil,Capacitor, SNPS,Relay,Thermostate, All Material 7) Providing every Minor and mejor Parts when it damaged or rusted parts Compressor complete as per terms and condition (MR) ( comprehensive) |
| 8 | Item No:7Monthly Servicing and visiting for complete checking 5.0 HP to 10.00 HP VRF/VFD Air Conditioner Monthly servicing 2) on call repair 3) replacement of all spares within 24 hours 4) sending standby manpower for VIP movement.5) The job include sheet metal work and plastic material with Electrical Parts, Compressor and essential Material.6)Including Gas Charging,Fan Motor, Condenser Coil,Capacitor, SNPS,Relay,Thermostate, All Material 7) Providing every Minor and mejor Parts when it damaged or rusted parts Compressor complete as per terms and condition (MR) ( comprehensive) |
| 9 | Item No:8Monthly Servicing and visiting for complete checking 200HP Chiller Plant Air Conditioner Monthly servicing 2) on call repair 3) replacement of all spares within 24 hours 4) sending standby manpower for VIP movement.5) The job include sheet metal work and plastic material with Electrical Parts, Compressor and essential Material.6)Including Gas Charging,Fan Motor, Condenser Coil,Capacitor, SNPS,Relay,Thermostate,Gasket All Material 7) Providing every Minor and mejor Parts when it damaged or rusted parts Compressor complete as per terms and condition (MR) (comprehensive) |
| 10 | Item No:9Supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0TR to 1.2TR capacity having ISEER minimum 3.5 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handlingunit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/WAC (3-2-3) |
| 11 | Item No:10Supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 3.5 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handlingunit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. AP-AC/ WAC (3-2-5) |
| 12 | Item No:11Supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.7TR to 2.00TR capacity having ISEER minimum 3.1 to maximum 3.29 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise levelmaximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/WAC (3-2-6) |
| 13 | Item No.12Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete as per specification no. AP/AC-CP (3-2-27) |
| 14 | Item No.13Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 22mm complete as per specification no. AP/AC-CP (3-2-28) |
| 15 | Item No.14Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 16 mm for solar water heater /AC system. (4-2-4) |
| 16 | Item No.15Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 22 mm for solar water heater /AC system. (4-2-6) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 51 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 51 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 52 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender