Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Firefighting System; Service Provider - Providing Servicing And Repairs To Automatic Fire Detection Control Panel Including Cleaning
Tender Overview
Project Description
Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Firefighting System; Service Provider - Providing Servicing And Repairs To Automatic Fire Detection Control Panel Including Cleaning Modules And Mother Board , Tracing And Checking Internal Wiring /Connections Between Modules And Mother Board , Replacing Damaged Wires , Replacing Defective Relays , Checking Visual And Audio Functions Of Zone Modules , Power Supply , Charger And Alarm Modules By Creating Open, Short,Fire, And Isolate Conditions And Attending Small Defects In Zone Loop Circuits ,Checking Battery Condition , Terminal Contacts Etc Including Testing And Commissioning The Panel, Fire Drill Etc As Reqd. Except Replacing The Defective Mudules Etc Conplete As Reqd. , Rectification Of Faults In Following Modules In The Existing Fd Alarm Control Panel I/C Replacing Defective Componanats Like Ics , Relays , Scrs ,Transistors , Capacitors Etc As Required. , Sitc Of Electronic Hooter Suitable For Fd Panel Etc As Reqd. , Servicing And Repairs To Electronic Hooter Including Replacing Defecticve Ics , Speakers , Pcb Etc As Reqd. , Servicing And Repairs To Mcp ( Manual Call Point ) I/C Replacing Broken Glass,Hammer,Etc Complete As Reqd. , Servicing , Checking And Cleaning Existing Smoke /Heat Detectors , Removing Ead Cover And Cleaning With Blower And Attending Minor Defects .Checking Each Detector By Creating Open, Short And Fire Conditions ,Including Zone Loop Wiring ,Testing And Commissioning Etc Complete As Reqd. , Servicing , Checking And Cleaning Response Indicators I/C Replacing Defective Leds , Resistors , Testing And Commissioning Etc Complete As Reqd, , Sitc Of Photoelectric Type Smoke Detector With Base Plate I/C Removing Existing Defective Detector Etc Comlete As Reqd. , Sitc Of 12 V 7Ah Sealed Maintenance Free Battery Suitable For Existing Fd System Control Panel I/C Removing Exiting Batteries And Connections Etc Complete As Reqd. , Sitc Of 12 V 26Ah Sealed Maintenmance Free Battery Suitable For Existing Fd System Control Panel Including Removing Existing Defective Battery And Connections Etc Complete As Reqd.
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Providing servicing and repairs to Automatic fire detection Control panel including cleaning modules and mother board , tracing and checking internal wiring /connections between Modules and mother board , replacing damaged wires , replacing defective Relays , checking visual and audio functions of zone modules , power supply , charger and Alarm modules by creating Open, Short,Fire, and isolate conditions and attending small defects in zone loop circuits ,checking battery condition , terminal contacts etc including testing and commissioning the Panel, fire drill etc as reqd. except replacing the defective mudules etc conplete as reqd. | Providing servicing and repairs to Automatic fire detection Control panel including cleaning modules and mother board , tracing and checking internal wiring /connections between Modules and mother board , replacing damaged wires , replacing defective Relays , checking visual and audio functions of zone modules , power supply , charger and Alarm modules by creating Open, Short,Fire, and isolate conditions and attending small defects in zone loop circuits ,checking battery condition , terminal contacts etc including testing and commissioning the Panel, fire drill etc as reqd. except replacing the defective mudules etc conplete as reqd. |
| 2 | Rectification of faults in following modules in the existing FD Alarm Control panel i/c replacing defective componanats like Ics , Relays , SCRs ,Transistors , capacitors etc as required. | Rectification of faults in following modules in the existing FD Alarm Control panel i/c replacing defective componanats like Ics , Relays , SCRs ,Transistors , capacitors etc as required. |
| 3 | SITC of Electronic Hooter suitable for FD Panel etc as reqd. | SITC of Electronic Hooter suitable for FD Panel etc as reqd. |
| 4 | Servicing and repairs to electronic hooter including replacing defecticve Ics , Speakers , PCB etc as reqd. | Servicing and repairs to electronic hooter including replacing defecticve Ics , Speakers , PCB etc as reqd. |
| 5 | Servicing and repairs to MCP ( Manual Call Point ) i/c replacing broken glass,Hammer,etc complete as reqd. | Servicing and repairs to MCP ( Manual Call Point ) i/c replacing broken glass,Hammer,etc complete as reqd. |
| 6 | Servicing , checking and cleaning existing smoke /Heat detectors , removing ead cover and cleaning with blower and attending minor defects .Checking each detector by creating Open, short and Fire conditions ,including zone loop wiring ,testing and commissioning etc complete as reqd. | Servicing , checking and cleaning existing smoke /Heat detectors , removing ead cover and cleaning with blower and attending minor defects .Checking each detector by creating Open, short and Fire conditions ,including zone loop wiring ,testing and commissioning etc complete as reqd. |
| 7 | Servicing , checking and cleaning Response Indicators i/c replacing defective LEDs , Resistors , testing and commissioning etc complete as reqd, | Servicing , checking and cleaning Response Indicators i/c replacing defective LEDs , Resistors , testing and commissioning etc complete as reqd, |
| 8 | SITC of photoelectric type smoke detector with base plate i/c removing existing defective detector etc comlete as reqd. | SITC of photoelectric type smoke detector with base plate i/c removing existing defective detector etc comlete as reqd. |
| 9 | SITC of 12 V 7AH sealed maintenance free battery suitable for existing FD system control Panel i/c removing exiting batteries and connections etc complete as reqd. | SITC of 12 V 7AH sealed maintenance free battery suitable for existing FD system control Panel i/c removing exiting batteries and connections etc complete as reqd. |
| 10 | SITC of 12 V 26AH sealed maintenmance free battery suitable for existing FD system control Panel including removing existing defective battery and connections etc complete as reqd. | SITC of 12 V 26AH sealed maintenmance free battery suitable for existing FD system control Panel including removing existing defective battery and connections etc complete as reqd. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender