Tender For Repair/Maint Of Lt Cable Joints And E/M Repair To Electric Supply Sub Station And Other Connected Works At Af Station Gwalior
Tender Value
45 Lakhs
Estimated cost
Bid Submission
11 Aug 2026
21 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gwalior → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maint Of Lt Cable Joints And E/M Repair To Electric Supply Sub Station And Other Connected Works At Af Station Gwalior
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m complete all as specified and as directed. Note : Excavation shall be made carefully in order to avoid damage of existing cables and protection covers. |
| 2 | Returning, filling including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed & tested complete all as specified and directed. |
| 3 | Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 4 | M&L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed. Note: Punned thickness of sand shall be measured and paid separately. |
| 5 | Supplying & Laying Sub Class 'B’ common burnt bricks old size as in cable protection complete all as specified and directed. |
| 6 | Laying only old retrieved serviceable bricks/cable covers for cable protection as obtained from dismantling of the existing cable complete all as specified and directed. |
| 7 | Disconnecting, taking out and removing old existing unserviceable underground, LT cable of any type and in any position complete including taking down protection pipe and seviceable bricks/ cable covers and stack up at the site properly complete all as specified and directed for the following sizes: |
| 8 | 10 Sqmm to 25 Sqmm any core |
| 9 | 35 Sqmm to 70 Sqmm 3½ core |
| 10 | 95 Sqmm to 150 Sqmm 3½ core |
| 11 | 185 Sqmm to 300 sqmm 3½ core |
| 12 | Laying, jointing and testing XLPE / P.V.C insulated, armoured, heavy duty, aluminium conductor cable 1100 volts grade of any type laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes :- Note: Old serviceable cable received from Item No. 07 shall be used in this item. |
| 13 | 10 Sqmm to 25 Sqmm any core |
| 14 | 35 Sqmm to 70 Sqmm 3½ core |
| 15 | 95 Sqmm to 150 Sqmm 3½ core |
| 16 | 185 Sqmm to 300 sqmm 3½ core |
| 17 | Supply, laying, jointing and testing XLPE insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade laid in trenches/ducts, floors, fixed to walls etc complete all as specified and directed for the following sizes: |
| 18 | 16 Sqmm 4 core |
| 19 | 25 Sqmm 4 core |
| 20 | 35 Sqmm 4 core |
| 21 | 50 Sqmm 3.5 core |
| 22 | 70 Sqmm 3.5 core |
| 23 | 95 Sqmm 3.5 core |
| 24 | 120 Sqmm 3.5 core |
| 25 | 150 Sqmm 3.5 core |
| 26 | 185 Sqmm 3.5 core |
| 27 | 240 Sqmm 3.5 core |
| 28 | 300 Sqmm 3.5 core |
| 29 | M& for jointing and testing for provision of straight through joints, Heat shrinkable, suitable for XLPE, LT UG Cable, 1100 Volts grade, for following sizes complete all as specified and directed. |
| 30 | 10 Sqmm to 16 Sqmm any core |
| 31 | 25 Sqmm to 50 Sqmm 3½ core |
| 32 | 70 Sqmm to 120 Sqmm 3½ core |
| 33 | 150 Sqmm to 185 Sqmm 3½ core |
| 34 | 240 Sqmm to 300 Sqmm 3½ core |
| 35 | S&F for cable jointing kit in repairs for 1.1 KV grade cable for end termination heat shrinkable type joints with jointing material and accessories suitable for 3.5 core 16 to 50 sqmm XLPE insulated armoured aluminium conductor cable complete all as specified and directed. |
| 36 | S&F for cable jointing kit in repairs for 1.1 KV grade cable for end termination heat shrinkable type joints with jointing material and accessories suitable for 3.5 core 70 to 120 sqmm XLPE insulated armoured aluminium conductor cable complete all as specified and directed. |
| 37 | S&F for cable jointing kit in repairs for 1.1 KV grade cable for end termination heat shrinkable type joints with jointing material and accessories suitable for 3.5 core 150 to 300 sqmm XLPE insulated armoured aluminium conductor cable complete all as specified and directed. |
| 38 | Demolition for cement concrete/road in ground floor and paving n. exc 15 cm thickness below or above ground level including removal of rubbish to a distance exc 50 mtr etc complete all as specified and directed. |
| 39 | M&L for GI water tubing, 40 mm bore, light grade as in sleeving etc laid in trenches / ducts / horizontal bore hole complete all as specified and directed. |
| 40 | All as per above Item No. 15 but GI tubing 50 mm bore. |
| 41 | All as per above Item No. 15 but GI tubing 80 mm bore. |
| 42 | All as per above Item No. 15 but GI tubing 100 mm bore. |
| 43 | Taking down existing LT cable from pole/ LT panel/ feeder pilar box etc. cutting the defective/burnt/cracked /heated, unserviceable end portion of cable, preparation of cable end of requird length retrived from rings/loops including necessary execavation and earth work and reconnect through protection pipe alongwith the pole/panels/feeder piller box etc with proper size of aluminium lugs, nuts, bolts, washer and M.S. clamps etc testing and commisioning complete all as specified and directed for the following size of LT cables :- Note: Cable joint required if any shall be measured and paid separately. |
| 44 | 10 Sqmm to 25 Sqmm cable of any core |
| 45 | 35 Sqmm to 70 Sqmm cable of any core |
| 46 | 95 Sqmm to 150 Sqmm cable of any core |
| 47 | 185 Sqmm to 300 Sqmm cable of any core |
| 48 | Supply & fixing in replacement new PVC insulated, served with inner sheathed pvc tape weatherproof stranded Alumunium conductor cable twin core 6 Sqmm size for connecting from Over head conductor to light fitting complete all as specified and directed by Engineer-in-Charge. |
| 49 | All as per above Item No. 20 but of size 10 Sqmm. |
| 50 | All as per above Item No. 20 but of size 16 Sqmm. |
| 51 | Supply only PVC Electrical Insulation tape 25 RM complete all as specified and directed. |
| 52 | Supply the hard core broken stone/ boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick to a true surface at the places complete all as specified and directed. |
| 53 | Supply, fixing, testing and commissioning in repairs MCCB, 630 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = Ics, Icu = 50 KA with thermal setting 70% to 100% adjustable setting complete all as specified and directed. |
| 54 | Supply, fixing, testing and commissioning in repairs MCCB, 400 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = Ics, Icu = 36 KA with adjustable load setting complete all as specified and directed. |
| 55 | Supply, fixing, testing and commissioning in repairs MCCB, 250 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = Ics, Icu = 36 KA with adjustable load setting complete all as specified and directed. |
| 56 | Supply, fixing, testing and commissioning in repairs MCCB, 200 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = Ics, Icu =36 KA with adjustable load setting complete all as specified and directed. |
| 57 | Supply, fixing, testing and commissioning in repairs MCCB, 160 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = Ics, Icu =36 KA with adjustable load setting complete all as specified and directed. |
| 58 | Taking down old unservisable change over switch and S&F On load change over switch, four pole with advance neutral 100 Amps, 415 V, 50 Hz conforming to IS : 13947 Part-3 connecting up in the existing panel location including taking out existing unserviceable change over switch complete all as specified and as directed. Make : L&T / Havells / Schneider or equivalent |
| 59 | Dismantling & taking down of existing worn out / unserviceable aluminium conductor, steel reinforced (ACSR) of any type /size & in any position from existing LT/HT Poles/Lines complete all as specified and directed. Please Enable Macros to View BoQ information |
| 60 | Dismantling & taking down of existing worn out / unserviceable aluminium conductor, steel reinforced (ACSR) of any type /size & in any position from existing LT/HT Poles/Lines complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 21, 2026
11:30 IST
Tender Published
Tender notice published.
TodayAug 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 21 daysAug 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 28 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender