Tender For Estimate For Augmentation Of Receiving Station Hiller Bahie From 2X6.3Mva To 2X10 Mva
Tender Value
88.20 Lakhs
Estimated cost
Bid Submission
11 Aug 2026
18 days left
EMD
1.76 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Anantnag → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Estimate For Augmentation Of Receiving Station Hiller Bahie From 2X6.3Mva To 2X10 Mva
BOQ
| Sl. No. | Item Description |
| 1 | Transportation, loading, unloading and handling of 33/11kV, 10 MVA, ONAN, Copper wound, Out-door Type, conventional Power Transformer, Oil Filled with OLTC, LV Box and all accessories including HT and LT Terminal connections from ECSD Pampore to Hiller (Bahi) Receiving Station and its Installation, Testing & Commissioning with all Accessories at Site. |
| 2 | Dismantling, Transportation, loading, unloading and handling of old 33/11kV, 6.3 MVA Power Transformer with all accessories including HT and LT Terminal connections from Hiller (Bahi) Receiving Station to Divisional Stores Laizbal. |
| 3 | SITC of 12 Core 2.5 Sqmm Control Cable Copper Armoured, 1.1 Grade, ISI FRLS |
| 4 | SITC of 6 Core 2.5 Sqmm Control Cable Copper Armoured, 1.1 Grade, ISI FRLS |
| 5 | SITC of 2 Core 2.5 Sqmm Control Cable Copper Armoured, 1.1 Grade, ISI FRLS |
| 6 | SITC of 11 kV VCB Panel Board (12 kV, 1250A, 25 kA, Indoor) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays,3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port for 10 MVA (2+4) (2 Incomer, 4 Outgoing ) |
| 7 | SITC of 11 kV 3- Core ,XLPE, armoured,FRLS, 300 mm² for 2X10 MVA Power Transformer |
| 8 | 11 kV ,630 mm² Single Core ,XLPE armoured Cable FRLS. (with one spare length) for 2X10 MVA Power Transformer |
| 9 | SITC of 11kV Indoor Heat Shrinkable Cable Termination Kits for incoming Cable (Single/Three core) 630 mmsq |
| 10 | SITC of 11kV Outdoor Heat Shrinkable Cable Termination Kits for incoming Cable (Single/Three core) 630 mmsq |
| 11 | SITC of 11kV Indoor Heat Shrinkable Cable Termination Kits for Outgoing Cable 300mmsq |
| 12 | SITC of 11 kV Outdoor Heat Shrinkable Cable Termination Kits for Outgoing Cable 300mmsq |
| 13 | SITC of 11 kV Isolator, Double Break,3-pole, 630Amp, horizental mounting Type, with Earth Switch. |
| 14 | SITC of 9 Mtr. Long Pole(ST-410 SP33) |
| 15 | Cement bottoming 1:2:4 mix as per Standards 0.48 cum/pole |
| 16 | SITC of Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 3 mtr long through GI Strip (25x3)mm |
| 17 | Red Oxide |
| 18 | Aluminium Paint |
| 19 | SITC of Earthing of Power Transformer (Improvement/strengthening works only) |
| 20 | SITC of Battery Bank 30 V,100 AH , of 15 No. cells of 2 V each, sealed maintenance free VRLA type,High impact Polyprophelene copolymer |
| 21 | SITC of 30V,100 AH , Float-Cum-Boost Charger With Full wave rectification for 220 V, 1Phase, 50 HZ AC Input Supply |
| 22 | SITC of 33 kV Isolator with Earthing Blade (36kV,800A, Outdoor,3 poles, 25 kA) |
| 23 | SITC of Yard Lighting by way of Providing 12.5 Mtrmotorised High Mast with 4 No.s of 200 W LEDflood lights on each High Mast complete withearthing , and foundations |
| 24 | SITC of 11 kV Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type with all accessories including insulators and Earthing |
| 25 | SITC of 33 kV Vacuum Circuit Breaker (36 kV, 1250A, 26.2 kA, Outdoor Type) |
| 26 | SITC of 33 kV Isolator without Earthing Blade (36kV,800A, Outdoor,3 poles, 25 kA) |
| 27 | SITC of 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ) |
| 28 | SITC of 33 kV Lightening Arrestors (33 kV, 10kA, Station class, ZnO, Polymer) gap less (1 No. per Φ) |
| 29 | SITC of 33 kV C&R Panel along with O/C, E/F,REF and differential relays (IEC61850), mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port |
| 30 | SITC of 33 kV 10 kN Post Insulator Polymer 36kV,235kV Impulse, creepage distance 1224m |
| 31 | SITC of 11 Mtr. Long Pole ( ST-410 SP56) |
| 32 | SITC of Cement bottoming 1:2:4 mix as per Standards 0.66 cum/pole |
| 33 | SITC of Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip.25x3mm |
| 34 | Red Oxide |
| 35 | Aluminium Paint |
| 36 | SITC of G.I Pipe of Dia 150mm, 5.9 mm Thick 3 m long (15 No.s) with G.I Base Plate 8 mm Thick |
| 37 | SITC of Galvanised Steel Structures (600 Kg) |
| 38 | SITC of Galvanised Nuts & Bolts (50 Kg) |
| 39 | SITC of 12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. |
| 40 | SITC of 6 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. |
| 41 | SITC of 2 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. |
| 42 | SITC of Lugs, Ferrules etc. |
| 43 | SITC of 200 mm² ACSR Conductor( Panther) |
| 44 | SITC of T Clamps |
| 45 | SITC of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fitting |
| 46 | Earth Work in Excavation by manual means with disposal of excavated soil |
| 47 | Providing & laying of Stone Soling hand packed complete in bed |
| 48 | Providing & laying of cement concrete (1:3:6) |
| 49 | Yard Metalling with 40mm aggregate stone |
| 50 | SITC of Fire Extingiusher Co₂ Type of 4.5 kg capacity for control room |
| 51 | Cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 20 mm nominal size) for Equipment Foundations |
| 52 | Reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 20 mm nominal size for Transformer Foundation Extension including 15mm plastering (1:6) |
| 53 | Construction of Cable Trench (750mm) as per approved drawings of KPDCL |
| 54 | Dismantling of Existing Old Equipment including, 11kV Cable of sizes, Panels and Under-Size GI Pipes, etc; and its return to Divisional Stores Laizbal |
| 55 | Supply of Tool Kit (Heavy Duty for 33/11kV Network) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysAug 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender