Tender For Urgent Repairing And Renovation Work(Incl. Civil & Electrical Works) Of Acharya J.C Bose Seminar Hall In The Post Graduate Department Of Physiology At Hooghly Mohsin College----Electrical Works
Tender Overview
Project Description
Tender for Urgent Repairing And Renovation Work(Incl. Civil & Electrical Works) Of Acharya J.C Bose Seminar Hall In The Post Graduate Department Of Physiology At Hooghly Mohsin College----Electrical Works
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 03-Aug-2026 | Last Date of Submission of Bid is hereby further extended up to 10.08.2026 | Date | 10-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC)in 20mm sizePVC rigid conduit 'FR' (Precisionmake), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light point switch 2no.2way Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2no.suitable size“Ph&N”copper bar with top cover plate making earthing attachment fixed on wall incl.mending good damages to original finishAverage run 10 mtr [2(b)/ E-24 ] |
| 2 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed]8 Mtr [4(c)/ E-25 ] |
| 3 | Distribution wiring in1.1KV grade 2x22/0.3(1.5sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved byEIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall],with1x22/0.3(1.5sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC,to light/fan/call bell point switch Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2no.suitable size“Ph& N” copper bar with top cover plate making earthing attachment fixed on wall incl.mending good damages to original finish.[PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed.8 Mtr [5(c)/ E-25 ] |
| 4 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR'PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish. On Board [ 3 (i) / E- 20 ] |
| 5 | 7.5 mtr. [E- 20 / 3(vi)] |
| 6 | Cutting Channel of required size on masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipe of following diameter as per GS.19 mm dia 3 mm thick [ 6 (a)/ E- 3 ] |
| 7 | 25mm dia 3 mm thick [ 7 (a)/ E- 3 ] |
| 8 | Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works20 mm size [ 7(a)/ E- 16 ] |
| 9 | 25 mm size [ 7(b)/ E- 16 ] |
| 10 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(Brand approved by E.I.C) of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS.3 x (1.5 sqmm) [1(b) / E- 9 ] |
| 11 | 2x(2.5 sqmm) + 1x(1.5 sqmm) [ 1(s) / E-9 ] |
| 12 | 2x(4 sqmm)+1x (2.5 sqmm) [ 1(v) / E- 9 ] |
| 13 | 2x (6 sqmm) + 1x (4 sqmm) [ 1(y) / E- 9 ] for SPNDBs |
| 14 | S & F solderless Copper socket by crimping of Copper wires. 2.5 sq mm [9(i) / F-5] |
| 15 | 4 sq mm [9(ii) / F-5] |
| 16 | 6 sq mm [9(iii) / F-5] |
| 17 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wall & 3 mm thick bakellite cover as per GS175 x 100 x 65 [11(c)/E-4 ,13(c)/E-5] |
| 18 | Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand approved by EIC), 6A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy.connections with PVC Cu wire and earth continuity wire etc. [E-18 / 12] |
| 19 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works.2 Row 12 Module 1(e)/E-17] |
| 20 | 6 module 1(b)/E-17] |
| 21 | Supplying & Fixing modular type socket /switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required. 6 A 5-pin modular type three pin socket [4(a)/E-17] |
| 22 | 6 A modular type switch [3(a)/E-17] |
| 23 | 16 A 5-pin modular type three pin socket [4(b)/E-17] |
| 24 | 16 A modular type switch [3(b)/E-17] |
| 25 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [5(a)/E-17] |
| 26 | Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [17/E-19] |
| 27 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections [5(b)/E-17] |
| 28 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand/Siemens/L&T as approved by E.I.C. )4 Way (Make - Make - Legrand/Siemens/L&T as approved by E.I.C] [ 14 / D- 10 ] . |
| 29 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS.2+8 Way [Siemens /Schneider or equivalent model of Legrand/L&T] as approved by EIC. [ 13 / D- 9 ] |
| 30 | Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment2 way [11/D-9] |
| 31 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per GS [Make-Legrand/ Schneider/Siemens/ Crabtree/ L&T) as per direction of EIC. ]40 A DP [ 6 / D- 5 ] |
| 32 | 63 A FP [ 6 / D- 5 ] |
| 33 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make-Legrand/ Schneider/Siemens/Crabtree/L&T) as per direction of EIC. ]6-32 SP [ 7 / D- 6] |
| 34 | Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make-Gloster/KEI/Polycab/Havells as approved E.I.C] [NS]4 Core 25 Sq. mm |
| 35 | Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting [ 2(b)/ F- 1 ] |
| 36 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :4 Core 25 Sq. mm [7(c)/F4 ] |
| 37 | Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc.4 Core 25 Sq. mm [ 8(b-xiii) /F5] |
| 38 | Supplying and delivery of LED Industrial Batten light made of CRCA Sheet Body (Thickness ≥ 0.50 mm) and construction as per relevant IS, along with LED lamp (Opal finish polycarbonate housing with Aluminium end-cap) voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 0o to 40o C, internal surge protection of 2.5 KV(internal) with Short & Open circuit protection , THD < 10% , P. F.≥0.9, IP20, CRI >80, and minimum 40000 Burning Hours (Life projection shall be calculated as per TM-21 methodology), CCT 5700°K /6500°K, and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing, with Minimum 5 year OEM warranty. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. (System lumen efficacy ≥115 lm/Watt).Single fittings along with S/F of 1 no. 18-20 W LED lamp as per specification [Make - CG / Bajaj / Wipro/Mazik] |
| 39 | Twin fittings along with S/F of 2 no. 18-20 W LED lamps as per specification [ Philips make Cat No. TMC-502 2xT-LED 22W[Make - CG / Bajaj / Wipro/Mazik] |
| 40 | Supply & Fixing angular batten holder (Anchor) on 75mm dia PVCround block / round bakelite on wall/ceiling as per GS [ 22/D-13 ] |
| 41 | Supply of 14 W LED bulb (Bajaj/CG/Philips/wipro) on existing batten holder. [NS] |
| 42 | Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) 2'x2' with powder-coated pressure Die-cast Aluminium/CRCA sheet body with high-transmission opal PMMA/ polycarbonate/ prismatic diffuser having uniform light distribution and construction as per IS : 10322. The driver rated output wattage should be 10% to 15% higher than lamp rating and efficiency Driver >80%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range 00 to 400 C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , PF ≥0.9, IP20, CRI >80, life time (LED, Driver & electrical circuitary), of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K/ 5700°K / 6000°K / 6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect and LED Chips of SMD Low to mid-power, as per requirement (LM-80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. LCTLRNE-36-FO-CDL/Wipro/Magik) [NS] System lumen efficacy ≥135 lm/Watt 36 Watt |
| 43 | Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) COB with powder-coated pressure Die-cast Aluminium with high-transmission opal PMMA/ polycarbonate/ prismatic diffuser having uniform light distribution and construction as per IS : 10322. The driver rated output wattage should be 10% to 15% higher than lamp rating and efficiency Driver >80%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range 00 to 400 C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , PF ≥0.9, IP20, CRI >80, life time (LED, Driver & electrical circuitary), of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K /6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housingComplete in all respect and LED Chips of SMD Low to mid-power, as per requirement (LM-80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. System lumen efficacy ≥ 110 lm/Watt.9 Watt |
| 44 | Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [ 17/C-2 ] |
| 45 | Fixing only single/twin LED Batten light fitting complete with all accessories Directly on wall/ceiling as per GS.[ 14d/C-2 ] |
| 46 | Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [16/C-2] |
| 47 | Fixing only lamp [ 11/C-2 ] |
| 48 | Supply & delivery of 230 V, 50 Hz, single phase, 52 watts, 48\\" (1200 mm) Sweep, speed 320 rpm (minimum), A.C. Ceiling Fan and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod (14 SWG & higher thickness), 2 nos. canopies, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum airdelivery 210 cu.m/min (minimum), without Regulator including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required |
| 49 | Supply & delivery of 230 V, 50 Hz, single phase, 40 watts , 9\\" (230 mm) Sweep, speed 1350 rpm (minimum), A.C. Exhaust Fan and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 650 cmh (minimum) including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 50 | Supply & Delivery of 230 V, 50 Hz, single phase, 85 watts, 18\\" (450mm), speed 1325 rpm (minimum), Bracket Fan and class of insulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body with metal back cover. Power Factor not less than 0.9 and minimum air delivery 110 cu.m/min (minimum), including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulationresistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 51 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl.painting the rod with approved paint and making necessaryconnection as required by 2x1.5 sqmm flexible copper wire. [ 21 (a) / C-3 ] |
| 52 | Supplying & Fixing MS fan clamp of two piece type for RCC as per approved specification as per GS. [ 29/D-14 ] |
| 53 | Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Legrand-Model Arteror/Myrius or equivalent model of Crabtree/Equivalent make as per direction of E.I.) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. [10/E18] [For Celling Fan] |
| 54 | Engraving the deptt. number with 10 mm lettering on the body of fan upto 10 letters incl. hifen, stroke or stop. [ 24(a)/C-3 ] |
| 55 | Extra for additional one letter incl. hifen, stroke and stop [ 24(b)/C-3 ] |
| 56 | Supply and Fixing of 20mm dia.14 SWG down rod for suspension of celling fans [NS] |
| 57 | Extra for supplying additional wire for down rod & painting the rod exceeding 30 cm by 2x1.5 sqmm flexible copper wire. [ 21(b)/C-3 ] |
| 58 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:23 cm (9\\") [28(a)/C-4] |
| 59 | Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) For GI9 \\" [32(b)/D-14] |
| 60 | Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts &washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length [29/C-3] |
| 61 | Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board as per GS [ 20( a )/D-13 ] |
| 62 | Dismantling the existing damaged defective unuseable electrical Installation materials.(Deployment of 2 nos.Skilled and 2 nos.unskilled man power). |
| 63 | Supplying and fixing of digital time switch (Mk- L&T, AUTS02DIG00) in existing 2 way SS encloser as per direction of EIC. |
| 64 | Supplying and fixing 415V, TPNSFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl.S&F 3 nos. DIN type HRC fuse as per rating. [4(a)/D-3] |
| 65 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required as following size as per GS.50 mm dia [11(d)/F-6] |
| 66 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level [ By TATA-Medium GI pipe] [2(a)/G-1]. |
| 67 | Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil) [1(a)/G-1] |
| 68 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement mortar (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2] |
| 69 | Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS No.-10 SWG [5(a)(iv)/G-2] |
| 70 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required [4(a)/G-2] |
| 71 | Connecting the equipments body to earth busbar includingS&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floorwith GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc [5(c)/G-3] |
| 72 | Add GST @18%:- Rs |
| 73 | Add LWC @1% Rs. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender