Tender For Expansion Of Unified Command & Control Platform Based Cctv Surveillance & Itms System To Talcher Town With Integration Of Dpo Angul Central Command Platform
Tender Value
3 Crore
Estimated cost
Bid Submission
03 Aug 2026
1 days left
EMD
3 Lakhs
Bank guarantee accepted
Document Fee
11800
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Anugul → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Expansion Of Unified Command & Control Platform Based Cctv Surveillance & Itms System To Talcher Town With Integration Of Dpo Angul Central Command Platform
BOQ
| Sl. No. | Item Description |
| 1 | Hardware Supply Items |
| 2 | Management, Recording, Mobile, ALPR, SQL Database, Failover, Federation & Failover / Redundant & plugin Server with Microsoft server licenses and RPS as per specification |
| 3 | Minimum 216TB Raw Recording Storage with dual power supply as per specification |
| 4 | Workstation with Intel i7 14th Gen or higher, 32 GB RAM, 8 GB Graphics card RTX 5060, 1 TB SSD, 2TB HDD & windows 11Professional as per specification |
| 5 | Dual Monitor Stand |
| 6 | 22\\" Monitor Full HD With HDMI Cable and mounting accessories |
| 7 | EDGE AI enabled IP 5 MP Bullet Camera with IR, motorised varifocal Lense POE Supported as per specification |
| 8 | AI enabled 5 MP IP PTZ camera, min 30x Zoom, min 150 mrt IR PoE Supported as per specification |
| 9 | FRS (facial recognition system) Bullet Camera motorised varifocal Lense POE Supported as per specification |
| 10 | ANPR Setup - EDGE based AI ML Bullet Camera for ANPR as per specification |
| 11 | Industrial Grade Giga POE++ Injector as per specification |
| 12 | 60W IP Public Announcement System as per specification |
| 13 | Layer 3- Managed Switch 24-port copper with 8 SFP & SFP++ port and stackable cables as per specification |
| 14 | L2 Fully Managed 24 Port Giga PoE Switch PoE Output with 4 SFP Port. (Outdoor use) as per specification |
| 15 | L2 Fully Managed 8 Port Giga PoE Switch PoE Output with 2 SFP Port. (Outdoor Use) as per specification |
| 16 | High End Security Firewall with HA 5 years subscription as per specification |
| 17 | Ransomware Protection with End point security & Server Antivirus package for all the servers and workstation as per specification |
| 18 | 24 port LIU with loaded as per specification |
| 19 | LC-LC Patch Cord as per specification |
| 20 | SC-LC Patch Cord as per specification |
| 21 | 1000 Base 1310nm SM Transceiver Module as per specification |
| 22 | 10 G Transceiver Module with FC Patch cord |
| 23 | Cat 6 factory made patch cord 5 Mtr |
| 24 | Cat 6 factory made patch cord 3 Mtr |
| 25 | Cat 6 factory made patch cord 2 Mtr |
| 26 | Cat 6 double jacketed UTP Cables Outdoor as per specification |
| 27 | OFC - 6 Core SM-Type Armored cable with Laying, Termination accessories as per specification |
| 28 | Cantilevers for camera mounting |
| 29 | 15U Water & Dust proof Metal Outdoor Rack with PDU, Fan etc. with chemical earthing materials as per specification |
| 30 | Water & Dust proof Metal Outdoor Back box for Camera |
| 31 | 1 KVA Online UPS with external battery for 1 hour power backup at rack location. as per specification |
| 32 | 20 KVA Online UPS with External Battery Rack, Cables etc. for 2-hour power back up as per specification |
| 33 | SPD for Power Line with accessories as per specification |
| 34 | PoE SPD for Cameras with accessories |
| 35 | Minimum 98” FHD Display, Connector, Bracket with accessories and installation as per specification |
| 36 | Video Display Controller with cables & accessories |
| 37 | Floor Mount Heavy duty 42U rack, 800 X 1000 MM with all accessories as per specification |
| 38 | Conduit for cable laying |
| 39 | Heavy Duty 6.5 Meter Galvanized VNPR Pole with Cantilever and Chemical Earthing materials |
| 40 | Heavy Duty 5 Meter Galvanized CCTV Camera Pole and Chemical Earthing materials |
| 41 | Industrial Air-Conditioner for Server Room for 24 X7 running with failover |
| 42 | Establishment of Data Center and Command & Control Room including required furniture, flooring, Firefighting system, water leak detector, Pest control, Acoustic wall panelling, Access control all doors, necessary electrical works, proper chemical earthing, for both building and data center appliances. |
| 43 | Unified command and control (UC2) platform software License as per specification |
| 44 | Video Management Software (VMS) License as per specification |
| 45 | GIS Map Integration License |
| 46 | 3rd Party Plugins Application Integration License |
| 47 | IP camera connection License as per specification |
| 48 | Mobile and Web Client connection License as per specification |
| 49 | License for vehicle number plate reading setup |
| 50 | FRS software and hardware complete setup as per specification |
| 51 | Federation Connectivity License. (for Central Operation, Monitoring & Management at Angul DPO) |
| 52 | SIP License for IP PA System |
| 53 | SIP Integration License for Central IP PA Console with UCC platform at Talcher and DPO, Angul |
| 54 | AI based Video Analytics Solutions |
| 55 | MS SQL Enterprise Database License |
| 56 | e-Challan Generation application with Reporting Dashboard |
| 57 | e-Challan Application Integration with Vahan Database |
| 58 | Intelligent Traffic enforcement License for Triple Riding, No-helmet, Wrong way Driving for e challan generation. |
| 59 | CAT 6 Cable Laying inside conduit, clipping, dressing with termination. |
| 60 | Outdoor Rack foundation, Fixing and Chemical Earthing |
| 61 | Electricity Connection Chrages for field locations |
| 62 | Field Location proper Civil Foundation and Mechanical works, Electrical Cabling for CCTV Camera Pole |
| 63 | Strong Civil Foundation and Mechanical works, Electrical Cabling for Heavy duty VNPR Pole-Cantilever |
| 64 | Project Management, documentation, planning, supervision, Installation, Testing, Integration, and Commissioning, Go live of the project with detailed training of Operators of Talcher Command & Control Room and Supervisorial training to officials at DPO, Angul. . |
| 65 | On-site Comprehenive Support service with manpower and electricity charges of field locations for1st year |
| 66 | On-site Comprehenive Support service with manpower and electricity charges of field locations for2nd year |
| 67 | On-site Comprehenive Support service with manpower and electricity charges of field locations for 3rd year |
| 68 | On-site Comprehenive Support service with manpower and electricity charges of field locations for4th year |
| 69 | On-site Comprehenive Support service with manpower and electricity charges of field locations for5th year Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayAug 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender