Tender For Construction Of Electrical Work Construction Of 33/11 Kv Sub-Station At Village-Amori(Ch Awat) And 01 No. 33 Kv Bay At 33 Kv Sub-Station Ch Wat (Ch Awat) Under The Head Of Capital (I.R.) (S.I.) Under Eswd, Kathgodam Haldwani Under The Head
Tender Overview
Project Description
Tender for Construction Of Electrical Work Construction Of 33/11 Kv Sub-Station At Village-Amori(Ch Awat) And 01 No. 33 Kv Bay At 33 Kv Sub-Station Ch Wat (Ch Awat) Under The Head Of Capital (I.R.) (S.I.) Under Eswd, Kathgodam Haldwani Under The Head Of Capital (S.I.). (Rates Should Be Quoted Without Gst) (Gst Will Paid Extra)
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 03-Aug-2026 | corrigendum | Date | 10-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Annexure-A (LABOUR CHARGES) |
| 2 | Cartage of other material by vehicle from Store Center to nearest construction site Store including loading and unloading at both ends(distance 151-200 Km). |
| 3 | Cartage of 5/8 MVA Power transformer by road(loading/unloading/shifting to be charged extra)(151-200 KM). |
| 4 | Cartage of the 33 KV VCB,feeder panels(O/D),T/F Control panel from store center to construction site with loading and unloading at b oth points.(Distance 0-20 Km) |
| 5 | EXCAVATION IN SOIL IN HILLY AREA/RIVER BED BY MECHANICAL MEANS I.E. BACKHOE LOADER |
| 6 | laying of MS bar 32 mm for making earth mat in switchyard area after fabrication / cutting in required size, laying at 2 mtr apart, also in crossing ( Making Net ), proper welding at each joint, laying at atleast 1 mtr depth in switchyard area for provi |
| 7 | ERECTION OF 33 KV VCB |
| 8 | ERECTION OF FLEXIBLE CU. CONN. 500X50 MM |
| 9 | EXCAVATION IN SOIL IN HILLY AREA/RIVER BED BY MECHANICAL MEANS I.E. BACKHOE LOADER |
| 10 | CEMENT PLASTER WORK |
| 11 | LAYING OF 11 KV CABLE |
| 12 | Jointing and fixing of cable jointing kit indoor/outdoor 11 KV XLPE heat shrinkable cable boxes |
| 13 | Erection of SP-33 double support pole in proper level and alignment along with fixing of all accessories like top channel,X bracings ,& clamps as per RESPO manual |
| 14 | FABRICATION OF STRUCTURE |
| 15 | CEMENT PLASTER WORK |
| 16 | SUPPLY & ERRECTION OF GRAVEL PITCHING OF SIZE 1/2\\" TO 3/4\\" (20X30X0.1) |
| 17 | PAINTING OF 33 KV CT STRUCTURE |
| 18 | PAINTING OF VCB PANELS( OUTER SURFACE AND INTERIOR LOWER AREA WHERE VCB IS PLACED) |
| 19 | EXCAVATION IN SOIL IN HILLY AREA/RIVER BED BY MECHANICAL MEANS I.E. BACKHOE LOADER |
| 20 | Grouting of structure in CC 1:3:6 in size (2x1.1x0.3x0.3) mtr. |
| 21 | Grouting of structure in CC 1:3:6 in size (2x1.1x0.3x0.3) mtr. |
| 22 | FIXING OF SODIUM/LED LIGHT AT YARD |
| 23 | MAKING CABLE TRENCH |
| 24 | Erection charges of structure |
| 25 | COMPLETE WIRING OF BREAKER BY PROVIDING FERULE ETC |
| 26 | ERECTION OF 33KV CONTROL PANEL (FEEDER/T/F) |
| 27 | Earth filling under floor and in sub-station area including cost of earth. Earth to be obtained from outside the corporation area in cluding its cartage and ramming, watering, dressing in 20 cm's thick layers including cost of earth with all lead and lift. |
| 28 | CEMENT PLASTER WORK |
| 29 | Grouting of structure in CC 1:3:6 in size (2x1.1x0.3x0.3) mtr. |
| 30 | FABRICATION OF STRUCTURE |
| 31 | FIXING OF 33 KV LIGHTNING ARRESTOR |
| 32 | Erection charges of structure |
| 33 | CEMENT PLASTER WORK |
| 34 | Grouting of structure in CC 1:3:6 in size (2x1.1x0.3x0.3) mtr. |
| 35 | EXCAVATION IN SOIL IN HILLY AREA/RIVER BED BY MECHANICAL MEANS I.E. BACKHOE LOADER |
| 36 | EXCAVATION IN SOIL IN HILLY AREA/RIVER BED BY MECHANICAL MEANS I.E. BACKHOE LOADER |
| 37 | FIXING OF ACCESSORIES |
| 38 | ERECTION OF LINE ISOLATOR STRUCTURE WITH INST. |
| 39 | CEMENT PLASTER WORK |
| 40 | PAINTING OF ISOLATOR/LA/CT/STRUCTURE COMPLETE |
| 41 | Installation / Fixing of 33 Kv Isolator on structure at 33 Kv switchyard with proper alignment & Connections with busbar comp lete. |
| 42 | FENCING OF YARD |
| 43 | FABRICATION OF STRUCTURE |
| 44 | PAINTING OF ISOLATOR/LA/CT/STRUCTURE COMPLETE |
| 45 | Grouting of structure in CC 1:3:6 in size (2x1.1x0.3x0.3) mtr. |
| 46 | ERECTION OF STAY POST |
| 47 | Erection of 11 KV VCB ( O/G or B/C or I/C ) Panel in all respect, making connection, testing etc in all respect at erection site |
| 48 | FABRICATION OF STRUCTURE |
| 49 | FABRICATION OF STRUCTURE |
| 50 | RCC 1:1.5:3 |
| 51 | FABRICATION OF STRUCTURE |
| 52 | EXCAVATION IN SOIL IN HILLY AREA/RIVER BED BY MECHANICAL MEANS I.E. BACKHOE LOADER |
| 53 | BRICK WORK WITH COMMON BURNT CLAP BRICKS WITH CEMNT MORTAR 1:4 |
| 54 | LAYING,SPREADING AND STRINGING BUS BAR CONDUCTOR BY ACSR PATH CONDUCTOR WITH MAKING ALL CONNECTIONS |
| 55 | FABRICATION OF STRUCTURE |
| 56 | EXCAVATION IN SOIL IN HILLY AREA/RIVER BED BY MECHANICAL MEANS I.E. BACKHOE LOADER. |
| 57 | EXCAVATION IN SOIL IN HILLY AREA/RIVER BED BY MECHANICAL MEANS I.E. BACKHOE LOADER. |
| 58 | ERECTION OF BUS GANTRY |
| 59 | CEMENT PLASTER WORK |
| 60 | Grouting of structure in CC 1:3:6 in size (2x1.1x0.3x0.3) mtr. |
| 61 | Grouting of structure in CC 1:3:6 in size (2x1.1x0.3x0.3) mtr. |
| 62 | PROVIDING AND LAYING IN POSITION CEMENT CONCRETE OF SPECIFIED GRADE EXCLUDING THE COST OF CENTERING AND SHUTTERING - ALL WORKS UPTO PLINTH LEVEL (I) 1:4:8 (1 - CEMENT; 4 - COARSE SAND; 8 - GRADED STONE AGGREGATE 40MM NOMINAL SIZE).( FOUNDATION). |
| 63 | FABRICATION OF R.S. JOIST 175X85 SQ.MM. |
| 64 | Erection of SP-10 single support pole in proper level and alignment along with fixing of all accessories like top channel,& clamps a s per RESPO manual |
| 65 | Painting of T.G. with one coat of Red oxide paint & 2 coats of Aluminum paints of best quality I.S.I. mark. |
| 66 | CEMENT PLASTER WORK |
| 67 | EXCAVATION IN SOIL IN HILLY AREA/RIVER BED BY MECHANICAL MEANS I.E. BACKHOE LOADER |
| 68 | FABRICATION OF STRUCTURE |
| 69 | Grouting of structure in CC 1:3:6 in size (2x1.1x0.3x0.3) mtr. |
| 70 | ERECTION OF TERMINAL GANTRY |
| 71 | Earthing with two Nos. G.I earth plates 600mm x 600mm x 6mm thick(1.5 meter minimum in between distance) including accessories and p roviding double masonry enclosure with cover plate having locking arrangement and watering pipe of 3 meter long etc. |
| 72 | Erection charges of structure |
| 73 | EARTHING OF STRUCTURE USING GI STRIP |
| 74 | PROVIDING AND LAYING IN POSITION CEMENT CONCRETE OF SPECIFIED GRADE EXCLUDING THE COST OF CENTERING AND SHUTTERING - ALL WORKS UPTO PLINTH LEVEL (I) 1:4:8 (1 - CEMENT; 4 - COARSE SAND; 8 - GRADED STONE AGGREGATE 40MM NOMINAL SIZE).( FOUNDATION). |
| 75 | CEMENT PLASTER WORK |
| 76 | CEMENT PLASTER WORK |
| 77 | BRICK WORK WITH COMMON BURNT CLAP BRICKS WITH CEMNT MORTAR 1:4 |
| 78 | PROVIDING AND LAYING IN POSITION CEMENT CONCRETE OF SPECIFIED GRADE EXCLUDING THE COST OF CENTERING AND SHUTTERING - (I) 1:2:4 (1 -CEMENT; 2 - COARSE SAND; 8 - GRADED STONE AGGREGATE 20MM NOMINAL SIZE).( ROAD REPAIRING /OTHER WORK) |
| 79 | RR massonary work in 1:6 ratio |
| 80 | PROVIDING AND LAYING IN POSITION CEMENT CONCRETE OF SPECIFIED GRADE EXCLUDING THE COST OF CENTERING AND SHUTTERING - ALL WORKS UPTO PLINTH LEVEL (I) 1:4:8 (1 - CEMENT; 4 - COARSE SAND; 8 - GRADED STONE AGGREGATE 40MM NOMINAL SIZE).( FOUNDATION). |
| 81 | Erection of SP-33 double support pole in proper level and alignment along with fixing of all accessories like top channel,X bracings ,& clamps as per RESPO manual |
| 82 | EARTHING OF STRUCTURE USING GI STRIP |
| 83 | ERECTION OF 24 VOLT BATTERY SET |
| 84 | CEMENT PLASTER WORK |
| 85 | Installation / Fixing of 33 Kv Isolator on structure at 33 Kv switchyard with proper alignment <(>&<)> Connections with busbar comp lete. |
| 86 | Laying and erection of L.T. PVC single lead Cable including crimping of lugs of size 1x240, 400, 630 Sq.mm etc. (Including all cost of material) |
| 87 | FABRICATION OF STRUCTURE |
| 88 | BRICK WORK WITH COMMON BURNT CLAP BRICKS WITH CEMNT MORTAR 1:4 |
| 89 | TESTING OF TRANSFORMER/VCB/PANEL |
| 90 | STEEL (REINFORCEMENT) |
| 91 | PAINTING OF ISOLATOR/LA/CT/STRUCTURE COMPLETE |
| 92 | INSTALLATION OF FIRE EXTINGUISHERS |
| 93 | PROVIDING AND LAYING IN POSITION CEMENT CONCRETE OF SPECIFIED GRADE EXCLUDING THE COST OF CENTERING AND SHUTTERING - ALL WORKS UPTO PLINTH LEVEL (I) 1:4:8 (1 - CEMENT; 4 - COARSE SAND; 8 - GRADED STONE AGGREGATE 40MM NOMINAL SIZE).( FOUNDATION). |
| 94 | PROVIDING AND LAYING IN POSITION CEMENT CONCRETE OF SPECIFIED GRADE EXCLUDING THE COST OF CENTERING AND SHUTTERING - ALL WORKS UPTO PLINTH LEVEL (I) 1:4:8 (1 - CEMENT; 4 - COARSE SAND; 8 - GRADED STONE AGGREGATE 40MM NOMINAL SIZE).( FOUNDATION). |
| 95 | Erection charges of structure |
| 96 | Digging of trench of size 0.60x0.15 x1.5 mtr. and laying of underground 33 KV XLPE cable with making of brick housing and filling of sand including filling of earth with ramming. & repairing of road including cost of cement sand and stone blast |
| 97 | ERECTION OF BUS BAR |
| 98 | ERECTION OF T&P ITEMS |
| 99 | PAINTING OF FUSE SET STRUCTURE |
| 100 | EXCAVATION IN SOIL IN HILLY AREA/RIVER BED BY MECHANICAL MEANS I.E. BACKHOE LOADER. |
| 101 | EXCAVATION IN SOIL IN HILLY AREA/RIVER BED BY MECHANICAL MEANS I.E. BACKHOE LOADER. |
| 102 | Laying of Control cable of all sizes through trench, proper connection at both ends outside in switchyard equipments & inside control room in VCB, control & relay Panels with proper marking, lugs , labelling & ferrules etc |
| 103 | FIXING AND ERECTION OF 33 KV OUTDOOR PT |
| 104 | Erection charges of structure |
| 105 | FABRICATION OF STRUCTURE |
| 106 | PAINTING OF BUS GANTRY |
| 107 | PAINTING OF ISOLATOR/LA/CT/STRUCTURE COMPLETE |
| 108 | EXCAVATION IN SOIL IN HILLY AREA/RIVER BED BY MECHANICAL MEANS I.E. BACKHOE LOADER |
| 109 | EARTHING OF STRUCTURE USING GI STRIP |
| 110 | CEMENT PLASTER WORK |
| 111 | CEMENT PLASTER WORK |
| 112 | ERECTION OF 33/0.433KV S/S TRANSFORMER |
| 113 | PAINTING OF DOUBLE POLE (SP-33) |
| 114 | EXCAVATION IN SOIL IN HILLY AREA/RIVER BED BY MECHANICAL MEANS I.E. BACKHOE LOADER |
| 115 | Erection of cable stand neutral stand including fabrication cutting and welding work. |
| 116 | FIXING OF 33 KV FUSE SET |
| 117 | EXCAVATION IN SOIL IN HILLY AREA/RIVER BED BY MECHANICAL MEANS I.E. BACKHOE LOADER |
| 118 | FIXING OF 33 KV LINE ISOLATOR VERTICAL TYPE ON ST POLE |
| 119 | Jointing and fixing of cable jointing kit indoor/outdoor 33 KV XLPE heat shrinkable cable boxes |
| 120 | INSTALLATION OF ACDB COMPLETE ON SUFACE OR WALL WITH THE HELP OF WALL ANCHOR BOLT FASTENERS 04NOS. COMPLETE TESTING AND COMMISSIONG OF DCDB AS PER SIDE REQUIREMENT AND NARRATED BY ENGINEER IN CHARGE OF THE WORK. |
| 121 | INSTALLATION OF DCDB COMPLETE ON SUFACE OR WALL WITH THE HELP OF WALL ANCHOR BOLT FASTENERS 04NOS. COMPLETE TESTING AND COMMISSIONG OF DCDB AS PER SIDE REQUIREMENT AND NARRATED BY ENGINEER IN CHARGE OF THE WORK. |
| 122 | ERECTION OF NAME PLATES |
| 123 | ERECTION OF SUB-STATION NAMED BOARD |
| 124 | ERECTION OF 24 VOLT BATTERY CHARGER |
| 125 | PROVIDING AND LAYING IN POSITION CEMENT CONCRETE OF SPECIFIED GRADE EXCLUDING THE COST OF CENTERING AND SHUTTERING - ALL WORKS UPTO PLINTH LEVEL (I) 1:4:8 (1 - CEMENT; 4 - COARSE SAND; 8 - GRADED STONE AGGREGATE 40MM NOMINAL SIZE).( FOUNDATION). |
| 126 | PROVIDING AND LAYING IN POSITION CEMENT CONCRETE OF SPECIFIED GRADE EXCLUDING THE COST OF CENTERING AND SHUTTERING - (I) 1:2:4 (1 -CEMENT; 2 - COARSE SAND; 8 - GRADED STONE AGGREGATE 20MM NOMINAL SIZE).( ROAD REPAIRING /OTHER WORK) |
| 127 | FIXING OF 33 KV FUSE SET |
| 128 | Erection of (8,5) MVA T/F at transformer plinth & erection of all accessories i.e. radiators, conservator tank, vent pipee etc., wit h the help of special type of T&P / crane etc. fitting cable etc. and refilling the fresh oil in radiator and conservator |
| 129 | FABRICATION OF STRUCTURE |
| 130 | SHIFTING OF 5 MVA T/F |
| 131 | FABRICATION OF STRUCTURE |
| 132 | Laying of Control cable of all sizes through trench, proper connection at both ends outside in switchyard equipments & inside control room in VCB, control relay Panels with proper marking, lugs , labelling & ferrules etc. |
| 133 | ERECTION OF 33 KV VCB |
| 134 | Fabrication of MS Channel angle iron etc in required sizes with drilling of holes upto good finish for top channel ,bracing and spec ial type bracket etc. as per RESPO schedule and local approced drawing. |
| 135 | ERECTION OF TERMINAL GANTRY |
| 136 | MAKING CABLE TRENCH |
| 137 | Painting of T.G. with one coat of Red oxide paint & 2 coats of Aluminum paints of best quality I.S.I. mark. |
| 138 | Installation of 33 KV CT with all connections |
| 139 | COMPLETE WIRING OF BREAKER BY PROVIDING FERULE ETC |
| 140 | PAINTING OF ISOLATOR/LA/CT/STRUCTURE COMPLETE |
| 141 | FIXING OF 33 KV LIGHTNING ARRESTOR |
| 142 | ERECTION OF LINE ISOLATOR STRUCTURE WITH INST. |
| 143 | LAYING,SPREADING AND STRINGING BUS BAR CONDUCTOR BY ACSR PATH CONDUCTOR WITH MAKING ALL CONNECTIONS |
| 144 | Erection charges of structure |
| 145 | EARTHING OF STRUCTURE USING GI STRIP |
| 146 | ERECTION OF 33KV CONTROL PANEL (FEEDER/T/F) |
| 147 | Installation / Fixing of 33 Kv Isolator on structure at 33 Kv switchyard with proper alignment & Connections with busbar complete. |
| 148 | Misclanious Charges for civil work |
| 149 | Annexure-B (SUPPLY ITEMS) (As per UPCL Norms) |
| 150 | MEGGAR 5 KV DIGITAL |
| 151 | 2.5 KV MEGGAR DIGITAL |
| 152 | MAXIMUM & MINIMUM DISPLAY BOARD |
| 153 | STEEL ALMIRAH |
| 154 | FIRE EXTINGUISHER ABC TYPE 5KG |
| 155 | PORTABLE FOAM TYPE FIRE EXTINGUISHER 5LT |
| 156 | 11 KV H/S JOINTING KIT 185 SQ MM (O/D) |
| 157 | WIRE MESH FENCING |
| 158 | OFFICE TABLE SIZE (4X2.5) |
| 159 | SUB STATION NAMED BOARD |
| 160 | EARTH MEGGAR DIGITAL |
| 161 | STEEL OFFICE CHAIR GODREJ |
| 162 | SINGLE LINE DIAGRAM BOARD |
| 163 | 90 WATT LED LIGHT WITH ACC. |
| 164 | G.I STRIP 35X5MM |
| 165 | STEEL OFFICE TABLE |
| 166 | EARTH CHAIN |
| 167 | D-SPANNER SET |
| 168 | NAME PLATE OF EQUIP. TG,LI,BI,CT,CB ECT. |
| 169 | CEILING FAN |
| 170 | FLEXIBLE COOPER CONNECTOR 50X50MM |
| 171 | INSTRUCTION BOARD |
| 172 | 11 KV H/S JOINTING KIT 185 SQ MM (I/D) |
| 173 | PG CLAMP FOR DOG CONDUCTOR |
| 174 | STAY CLAMP FOR SP-33 WITH NUT & BOLT |
| 175 | INSULATED ELECTRICAL PILLER TAPARIA |
| 176 | BOLT AND NUT 180X16 MM |
| 177 | 33/0.433 KV, 63 KVA STATION TRANSFORMER |
| 178 | 3X70 SQ MM XLPE 33 KV CABLE |
| 179 | ST. LIGHT MANAG. TIMER SWITCH WITH METER |
| 180 | DB I/C MCB 30A-1 NO. & OG MCB 10A-10NOS. |
| 181 | DCDB 24V |
| 182 | STEEL CABINET |
| 183 | MS BAR 10MM |
| 184 | SUNDRISE ITEM LUG GLADE ETC |
| 185 | GI PIPE 4'\\" DIA |
| 186 | PIPE WRENCH 12'' |
| 187 | TOP CHANNEL CLAMP FOR SP-33 WITH N&B |
| 188 | MS PLATE 225X225X8MM |
| 189 | PERFORATED TRAY 400MM FOR CABLE TRENCH |
| 190 | STONE PAD 300X300X75MM |
| 191 | WALL CLOCK |
| 192 | LED TORCH WITH ELECTRIC CHARGING |
| 193 | MS BAR 12MM DIA FOR STEEL REINFORCEMENT |
| 194 | SAFETY CHART |
| 195 | 24 V BATTERY SET |
| 196 | 33 KV HAND GLOVES |
| 197 | DOOR MAT |
| 198 | DUSTBIN PLASTIC SIZE (SMALL) |
| 199 | FIRST AID BOX |
| 200 | R.S. JOIST 175X85MM |
| 201 | MS ANGLE 40X40X5 MM |
| 202 | RAIL 90 LBS |
| 203 | RUBBER MAT(INSULATED)1MX1MX3MM |
| 204 | FIRE BUCKET STAND WITH BUCKETS |
| 205 | GI STRIP 50X6 MM |
| 206 | G.I EARTH STRIP 65X6MM |
| 207 | WALL FAN |
| 208 | M.S.PLATE 400X400X8 MM |
| 209 | CONNECTORS FOR FUSE SUITABLE FOR PANTHER |
| 210 | PG CLAMP ACSR PANTHER TO ACSR DOG |
| 211 | NAME PLATE OF FEEDER |
| 212 | 11KV DANGER BOARD WITH CLAMP |
| 213 | DANGER BOARD |
| 214 | SHUT DOWN/ BREAK DOWN BOARD |
| 215 | PERFORATED TRAY 200MM FOR CABLE TRENCH |
| 216 | PERFORATED TRAY 100MM FOR CABLE TRENCH |
| 217 | NAME PLATE OF STATION T/F |
| 218 | ALLUMINIUM LUG |
| 219 | 33 KV DANGER BOARD WITH CLAMP |
| 220 | BRACING CLAMP FOR ST POLE WITH N&B |
| 221 | TOP CHANNEL CLAMP FOR SP-33 WITH N&B |
| 222 | BOLT & NUTS OFF SIZE |
| 223 | T CONNECTOR |
| 224 | PG CLAMP ALU ALLOY PANTHER TO PANTHER |
| 225 | 24V BATTERY CHARGER |
| 226 | CONNECTOR SUITABLE. PANTHER FOR VCB |
| 227 | 11 KV FUSE SET |
| 228 | 11KV 3P(400A)3PIN VERT. MOUNT GO AB TPMO |
| 229 | PG CLAMP ALU ALLOY PANTHER TO DOG |
| 230 | CONNECTOR OF POWER T/F LV SIDE |
| 231 | PG CLAMP FOR PANTHER TO PANTHER |
| 232 | T CONNECTOR |
| 233 | MS NUT & BOLT OFF SIZE |
| 234 | CONNECTOR SUITABLE. PANTHER FOR VCB |
| 235 | CONNECTOR SUIT FOR CT/PT FOR PANTHER/DOG |
| 236 | CONNE.SUITABLE FOR PANTHER FOR LA |
| 237 | 33KV ISOLATOR CONN.CLAMP FOR PANTHER,N&B Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
TodayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender