Tender For Repairing & Operation Maintenance Of Road Light Timer Panel For 2 Year
Tender Value
50 Lakhs
Estimated cost
Bid Submission
27 Jul 2026
4 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pali → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairing & Operation Maintenance Of Road Light Timer Panel For 2 Year
BOQ
| Sl. No. | Item Description |
| 1 | Wireman, Electrician, Welder, Lineman, AC Mechanic, Fireman, , Supervisor, ELV technician or equivalent professional with ITI or Equivalent course and Experience of 2 years in relevant field ) |
| 2 | Supply, Installation, Testing and Commissioning of Smart Lighting Controller in existing feeder panels which includes, Inbuilt energy metering with 3 nos CT, Three phase power supply with withstanding capability up to 500 VAC, Instant mode, Fixed Mode, Astronomical Mode, Hybrid Mode, Interval Mode, Offset in Sunset and Sunrise Timing for scheduling. Provision for measurement of all three phase electrical parameters like voltage, current, power factor, power, frequency, energy with atleast class 1 accuracy and compliant with IS13779 standard, UV-OV protection, backup battery 4 hrs, Andriod/iOS app and software to operate form computer, provision to add display device externally, support for RS485 communiction , inbuilt GSM/GPRS 4G modem with 2G fallback, Real time GPS based clock, calender, lithium ion battery backup for RTC clock, Three relay output, Minimum Ninety days data memory inbuilt backup facility, Controller shall be type tested with NABL approved lab for EFT or burst testing for conducted immunity in accordance with IEC 610000-4-4, Software application should utilize a Low-Code/No-Code platform to simplify development and customization. It must be hardware-agnostic and compatible with other IoT-based smart city applications. Software should have undergone a \\"Vulnerability Assessment and Penetration Testing (VAPT)\\" as per OWASP Top 10 2021 and 2022, SANS CWE 24 & CERT-In Standard.Dedicated IoT communication GSM/GPRS SIMCard (with minimum 3 years of recharge)for 4G Communication with software application. 3 Years Data Hosting & Server Charges to be included with software. |
| 3 | Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as required of following size. |
| 4 | 16 Sq MM 4 Core |
| 5 | Providing & Laying XLPE insulated & P.V.C. sheathed Un-armoured Copper cable confirming to IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing commissioning etc. as required of following size. |
| 6 | 6 Sq MM 4 Core |
| 7 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanism , energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. |
| 8 | Single pole MCB (With B / C curve tripping characteristics) |
| 9 | 50/63 A rating |
| 10 | Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor confirming to IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. |
| 11 | 50 Amp 3 pole Power contactors with following AC 3 Rating |
| 12 | P & Fixing Powder coated CRCA sheet enclosures on existing Structure by means of nuts and bolts and making holes , Din rail etc. as required. |
| 13 | 1.6 mm thick Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysJul 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender