Tender For Annual Repairs & Maintenance Contract For Electrical And Mechanical Services Alongwith Requisite Materials At Fsd Sangaiprou And Fsd Jiribam For Fy 2026-27 Under Do Imphal
Tender Value
8.28 Lakhs
Estimated cost
Bid Submission
03 Aug 2026
10 days left
EMD
16560
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Imphal West → Manipur
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Annual Repairs & Maintenance Contract For Electrical And Mechanical Services Alongwith Requisite Materials At Fsd Sangaiprou And Fsd Jiribam For Fy 2026-27 Under Do Imphal
BOQ
| Sl. No. | Item Description |
| 1 | Repairs and maintenance of following electrical and mechanical installations, details as follows and according to terms and conditions mentioned as per I.E. rules.a) E.I., Lights/Fans/Plug points/ Powerpoints and Street/ Compound lighting arrengements as per I.E. Rules as detailed inside at page.b) Water supply arrangementc) Water cooler (Electrical)d) Air coolerse) Air conditioners (Electrical)f) Feeder pillars/LT panels maintenanceg) Transformer (preventive)H) High Mast Tower systemi) Other miscellaneous electrical & mechanical works directed by site engineer.Note:1) The contractor must arrange for all types of ladders (Self supported & wall supported), safety gears and tools at sites w.r.t. Working height up to 15 meters in suspension / wall or pole.FSD Sangaiprou - 1 wireman + 1 helper (2 days per week ) = 104 Days FSD Jiribam - 1 wireman + 1 helper (2 days per week ) = 104 Days Total 104 Days for wireman and 104 Days for helper in a year |
| 2 | One Wireman for 2 days a week at FSD Sangaiprou |
| 3 | One Helper for 2 days a week at FSD Sangaiprou |
| 4 | One Wireman for 2 days a week at FSD Jiribam |
| 5 | One Helper for 2 days a week at FSD Jiribam |
| 6 | Supply of ISI marked, FRLS/HFFR PVC insulated, single core copper conductor cableof following sizes |
| 7 | 1.5 sqmm |
| 8 | 2.5 sqmm |
| 9 | 4 sqmm |
| 10 | Supply of following accessories |
| 11 | 5/6 amp piano / tumbler type switch |
| 12 | 5/6 amp piano type socket outlet |
| 13 | 5/6 amp Modular type switch |
| 14 | 5/6 amp Modular type socket outlet |
| 15 | Supply of following 6 amp to 32 amp capacity \\"c\\" curve MCB, Isolator and RCCB with 10 KA breaking capacity |
| 16 | Single pole MCB |
| 17 | Double pole MCB |
| 18 | Supply of 63 amp capacity FP isolator |
| 19 | Supply of 25 amp capacity 30ma to 300ma breaking capacity DP RCCB |
| 20 | Supply of following sizes MS conduit pipe , ISI mark including accessories with saddle |
| 21 | 20 mm dia |
| 22 | 25 mm dia |
| 23 | For Repairing of ceiling fan / exhaust fan |
| 24 | Capacitor |
| 25 | Bearing |
| 26 | Supply of following accessories for repairing of light fixture |
| 27 | Supplying of 18- 22 Watt LED surface mounted Batten light of following bodymaterial and construction as per IS : 10322 withdriver (Replaceable) as per the requirement withDriver efficiency >85% ,Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range-5 0C to 40 0C, internal surge protection of 2.5 KVwith Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80, Flicker free (flicker shouldbe below 5 %), life time (LED, Driver & electricalcircuitry), of minimum 50000 Burning Hours47 DELHI SCHEDULE OF RATES (E&M)-2025with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K(As per ANSI Bin), SDCM(Standard DeviationColor Matching) <3, Maximum power consumptionshould not more than the specified rating andFixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing complete inall respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).LED Batten light (System lumen efficacy >135 lm/Watt).Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 28 | 45 W LED Street light fixture, powder coated pressuredie cast aluminium body (System lumen efficacy>135 lm/Watt).Supplying 45 W of Street light LED fixture, powder coatedpressure die cast aluminium body with built in orseparate driver as per the equirement with Driverefficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to50 0C, internal surge protection of 5 KV L,N,E as perIEC 61000-4-5, Driver efficiency >85%,THD < 10%as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angleas per IESNA type I/II/III as per the width of the roadand the project requirement., suitable to fit in up to65mm dia pipe, life time (LED,Driver & electricalcircuitary) of minimum 50000 Burning Hourswith 70% of initial Lumen maintained till lifeends as per LM80 extrapolation IES TM-21-11report, CCT 3000°K / 4000°K / 5700°K /6500°K (Asper ANSI Bin), SDCM(Standard Deviation ColorMatching) <5, Maximum power onsumption shouldnot more than the specified rating and Fixture shall be of relevant BIS standard complete in all51 DELHI SCHEDULE OF RATES (E&M)-2025 respect i/c external connections with 1.5 sq mmFRLS/HFFR, PVC insulated copper conductorsingle core cable and earthing etc. as required withMinimum 5 year OEM warranty. System lumenefficacy >135 lm/Watt output . LM79 & LM80 Testreport and all testing required for LED fixturesas per BIS shall be submitted.. Shape size andCCT shall be as approved by Engineer-in-Charge asper requirement. (Thermal anagement: heat sinkof aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 29 | Supply of XLPE insulated and PVC sheathed CABLE of 1.1 kv grade armoured Al. cable compulsory ISI mark confirming to IS:7098/ PART –I / 88 of following sizes |
| 30 | 3.5 X 25 sqmm |
| 31 | 2 X 10 sqmm |
| 32 | 4 X 16 sqmm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysAug 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender