Tender For Repair/Maint Of Feeder Pillar Box Outdoor/ Indoor Panels And Allied Works At Upper Leimakhong, Lower Leimakhong, Central Sector And Koirengei Mil Stn.
Tender Value
30 Lakhs
Estimated cost
Bid Submission
10 Aug 2026
19 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kangpokpi → Manipur
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maint Of Feeder Pillar Box Outdoor/ Indoor Panels And Allied Works At Upper Leimakhong, Lower Leimakhong, Central Sector And Koirengei Mil Stn.
BOQ
| Sl. No. | Item Description |
| 1 | Schedule 'A' |
| 2 | S&F in repair MCCB 4 pole, 415 V, 63 Amp with breaking capacity 16 KA complete all as specified and as directed. |
| 3 | S&F in repair MCCB 4 pole, 415 V, 100 Amp with breaking capacity 16 KA complete all as specified and as directed. |
| 4 | S&F in repair MCCB 4 pole, 415 V,125 Amp with breaking capacity 16 KA complete all as specified and directed. |
| 5 | S&F in repair MCCB 4 pole, 415 V, 160 Amp with breaking capacity 36 KA complete all as specified and directed. |
| 6 | S&F in repair MCCB 4 pole, 415 V, 200 Amp with breaking capacity 36 KA complete all as specified and directed. |
| 7 | S&F in repair MCCB 4 pole, 415 V, 250 Amp with breaking capacity 36 KA complete all as specified and directed. |
| 8 | S&F in repair MCCB 4 pole, 415 V, 400 Amp with breaking capacity 36 KA complete all as specified and directed. |
| 9 | S&F in repair MCCB 4 pole, 415 V, 630 Amp with breaking capacity 36 KA complete all as specified and directed. |
| 10 | S&F in repair ACB (Air Circuit Breaker) 630 Amps, 4 Pole, 50 KA, 415 V , 50 Hz rated with Thermal Magnetic Release (Manual Fixed type) complete all as specified and directed. |
| 11 | Excavation in trenches n. exc 1.5 m in depth and not exc 1.5 m wide for laying of UG cables etc and getting out in soft/ loose soil complete all as specified. |
| 12 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified. |
| 13 | Removing excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5 above the starting point complete all as specified and as directed by Engr-in-charge. |
| 14 | Cutting the existing road/hard standing etc of any description of surface and excavation in trenches 30cm wide and 60cm depth for laying of UG electric cable and all as directed. (The rate includes returning, filling, watering and ramming in layers and making good the surface with PCC 1:3:6 as the exisiting after laying of elctric cables) |
| 15 | Supply and laying sand for cushioning of cable in trenches for cable protection including spreading, levelling and hand punning complete all as specified in SSR part-I and as directed by Engr-in-charge. Note-Thickness of sand cushioning sall be measured after punning and consolidating of sand. |
| 16 | Supply and laying bricks (old size) for cable protection by using common burnt clay building bricks, sub-class ‘B’ designation 75 laid dry flat across length of the cable with width of the trenches equal to length of bricks and all as directed. |
| 17 | S&F in repair GI tubing light grade 40mm dia for protection of cable on wall , road crossing, floor etc complete all as specified and as directed by Engr in charge. |
| 18 | Supply, laying in trenches, connecting and testing in repair LT UG cable, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm x 2 core all as specified and directed. |
| 19 | Supply, laying in trenches, connecting and testing in repair LT UG cable, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm x 2 core all as specified and directed. |
| 20 | Supply, laying in trenches, connecting and testing in repair LT UG cable, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm x 4 core all as specified and directed. |
| 21 | Supply, laying in trenches, connecting and testing in repair LT UG cable, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm x 4 core all as specified and directed. |
| 22 | Supply, laying in trenches, connecting and testing in repair LT UG cable, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sqmm x 4 core all as specified and directed. |
| 23 | Supply, laying in trenches, connecting and testing in repair LT UG cable, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sqmm x 3.5 core all as specified and directed. |
| 24 | Supply, laying in trenches, connecting and testing in repair LT UG cable, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sqmm x 3.5 core all as specified and directed. |
| 25 | Supply, laying in trenches, connecting and testing in repair LT UG cable, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 sqmm x 3.5 core all as specified and directed. |
| 26 | M&L for cleaning, scrapping re-painting of LT panel board with two coat of synthetic enamel paint complete all as specified and directed. |
| 27 | M&L for repair/ maintenance of indoor/out door type feeder pillar box any type door hinges broken,ms work structure damage,locking handle ,shutter not proper closed,rubber gasket , any type welding works required complete all as specified and directed. |
| 28 | Supply, installation , testing and commissioning in replacement of LT weather proof panel board powder coated CPRI Approved outdoor type double door shutter, made out of CRCA 3.0 mm thick sheet for outer and 1.6 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outoor, floor mounting type with closed bus bar , chamber and with copper bus bar with necessary insulators suitable for 3 phase, 4 wire 50 Hz AC supply as per CPRI approved including provn of digital Am-meter 0-300A, digital Volt-meter 0-500 Volts, CT's of suitable ratio,indicator lamps R-Y-B, selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following work also includes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc . The bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron (Main Panel)Alluminium bus bar capacity 400 Amps for Phase-R-Y-B- & neutral MCCB FP 250 Amps 35 KA- 01 Nos MCCB FP 100 Amps 16 KA- 01 Nos MCCB FP 63 Amps 16 KA- 06 NosOn Load Change over switch 250 Amps, 4 Pole, 415 volt - 01 NosDigital voltmeter, ammeter with selector switches and indicator lamp for each phase complete all as specified and as directed. |
| 29 | Earthing complete in repair with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized iron 25 x 4 mm strip as earthing lead by means of galvanized steel bolts, nuts check nuts and washers and other end connected with to Transformer ,DG set,Panel Board etc as directed including funnel, 20mm bore, light grade galvanized iron pipe, wire mesh charcoal of coal dust and common salt in alternative layer all around the earth electrode compacted thickness 15cm with concrete pit in PCC 1:3:6 type C1 50mm thick pre cast RCC 1:2:4 type B1with 8mm dia cover slab set in CM (1:4) re-enforcement with 8mm dia deformed bars @ 15cm C/C and suitable handle of 10mm dia MS round bars, including earth work as required complete all as shown in electrical plate No 5 of MES Schedule Part I and testing complete all as specified and as directed. |
| 30 | Supply & Fix in replacement digital 0 to 200 Amp meter complete all as specified. |
| 31 | Supply & Fix in replacement digital 0 to 500 Volt meter complete all as specified. |
| 32 | Supply & fix in repair CT coil 250/5 Amps complete all as specified |
| 33 | Supply & fixing in repair phase indicator lamp (R.Y.B) complete all as specified. |
| 34 | Supply & fixing in repair slector switch complete all as specified. |
| 35 | Supply & fix in repair on load change over switch four pole of cap 100 Amp of Frame 2 type , open execution complete all as specified. |
| 36 | Supply & fix in repair load change over switch four pole of cap 250 Amp of Frame 3 type , open execution complete all as specified. Please Enable Macros to View BoQ information |
| 37 | Supply & fix in repair load change over switch four pole of cap 250 Amp of Frame 3 type , open execution complete all as specified. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysAug 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer