Tender For Repair/ Replacement Of Lt Cables, Lt Oh Lines, Lt Insulators, Lt Panels Of Otm Accns At Kannur Mil Stn Under Ge (Army) Trivandrum
Tender Overview
Project Description
Tender for Repair/ Replacement Of Lt Cables, Lt Oh Lines, Lt Insulators, Lt Panels Of Otm Accns At Kannur Mil Stn Under Ge (Army) Trivandrum
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 24-Jul-2026 | Corrigendum No 1 (BoQ) | BOQ | 08-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Excavating in trenches in loose/ soft soil, not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth; for laying of LT UG cable, pipe, pole, stay etc and not exceeding 10 Sq.m on plan complete all as specified and directed. |
| 2 | Excavating in trenches in soft disintegrated rock, not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth; for laying of LT UG cable, pipe, pole, stay etc and not exceeding 10 Sq.m on plan complete all as specified and directed. |
| 3 | Excavating in trenches in hard/ dense soil, not exceeding 1.5 mtr wide and exceeding 1.5 Mtr and not exceeding 3 Mtr in depth; for laying of LT UG cable, pipe, pole, stay etc and not exceeding 10 sq.m on plan complete all as specified and directed. |
| 4 | Returning, filling in using soil obtained from excavation including spreading, levelling, watering and well ramming in layers not exceeding 25 Cm complete all as specified and directed. |
| 5 | Removing excavated surplus soil to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed. |
| 6 | M&L for filling dry sand under and around LT cable to provide sand cushioning and in sub station ducts/ trenches complete all as specified and directed. |
| 7 | M&L for brick well burnt locally available sub class 'B' laid over sand cushioning to cable in trenches keeping width of brick parallel to the length of cable complete all as specified and directed. |
| 8 | Supply, laying, jointing and testing XLPE insulated, armoured, heavy duty LT under ground cable 1100 Volts grade with aluminium conductor cross-sectional area 16 Sqmm 2 Core laid in trenches, on poles, through pipes, fixed to walls etc, including taking down old unserviceable cables complete all as specified and directed. |
| 9 | All as per item Ser No. 9 here in before, but cable of cross-sectional area 25 Sqmm 3.5 Core complete all as specified and directed. |
| 10 | All as per item Ser No. 9 here in before, but cable of cross-sectional area 50 Sqmm 3.5 Core complete all as specified and directed. |
| 11 | All as per item Ser No. 9 here in before, but cable of cross-sectional area 70 Sqmm 3.5 Core complete all as specified and directed. |
| 12 | All as per item Ser No. 9 here in before, but cable of cross-sectional area 95 Sqmm 3.5 Core complete all as specified and directed. |
| 13 | All as per item Ser No. 9 here in before, but cable of cross-sectional area 120 Sqmm 3.5 Core complete all as specified and directed. |
| 14 | All as per item Ser No. 9 here in before, but cable of cross-sectional area 185 Sqmm 3.5 Core complete all as specified and directed. |
| 15 | M&L for 40 mm bore tube medium grade galvanised with all fittings laid along the pole/ in trenches/ under road or floor of including removing the rusted old one complete all as specified and directed. |
| 16 | M&L for 80 mm bore tube medium grade galvanised with all fittings laid along the pole/ in trenches/ under road or floor of including removing the rusted old one complete all as specified and directed. |
| 17 | Supply and replacing of 1100 volts grade heavy duty cable PVC insulated aluminium conductor as service connections served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 01 metre apart including 4 mm dia GI suspension wire one twin core cable flat or circular stranded conductor of size 10 sqmm 2 core complete all as specified and directed. |
| 18 | Supply and fixing GI LT cable route indicators of size 10 cm dia & 3mm thick plate and angle iron leg of 60 cm length duly embossed LT cable on plate including PCC 15 x 15 x 20 cm foundation all as specified by Engineer -in-charge. |
| 19 | M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate including use and waste of form work of concrete for pole and stay foundation complete all as specified and directed. |
| 20 | M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate including use and waste of form work for pole coping/ any description complete all as specified and directed. |
| 21 | M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate including use and waste of form work for pole coping/ any description complete all as specified and directed. |
| 22 | Material and erection of Prestressed concrete pole, 9.0 metres long. 102mm x 152mm at top and 102mm x 289mm at bottom, class 10 complete and restringing of ACSR Conductor, Refixing of cross arm, insulators and stay wire etc including dismantling old and unserviceable pre stressed concrete poles any type including breaking cement concrete complete all as specified and directed by Engr-in charge. Note:- (a) Excavation shall be measured and paid separately.(b) Any new items like ACSR Conductor, Refixing of cross arm, insulators and stay wire etc will be measured and paid separately. Please Enable Macros to View BoQ information |
| 23 | Material and erection of Prestressed concrete pole, 9.0 metres long. 102mm x 152mm at top and 102mm x 289mm at bottom, class 10 complete and restringing of ACSR Conductor, Refixing of cross arm, insulators and stay wire etc including dismantling old and unserviceable pre stressed concrete poles any type including breaking cement concrete complete all as specified and directed by Engr-in charge. Note:- (a) Excavation shall be measured and paid separately.(b) Any new items like ACSR Conductor, Refixing of cross arm, insulators and stay wire etc will be measured and paid separately. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published