Defence Statutory Bodies & Commissions/Committees Closing in 15 days TDR #56580056

Tender For Engineering, Procurement & Construction (Epc) For Provision Of Modern Store House For Paints And Chemicals At maintenance of (Mbi), Ghatkopar

Issued by Statutory Bodies & Commissions/Committees · Mumbai Suburban, Maharashtra
Tender Value
20.62 Crore
Estimated cost
Bid Submission
25 Aug 2026
15 days left
EMD
13.56 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai Suburban → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Engineering, Procurement & Construction (Epc) For Provision Of Modern Store House For Paints And Chemicals At maintenance of (Mbi), Ghatkopar

BOQ

Name of Work:- ENGINEERING, PROCUREMENT & CONSTRUCTION (EPC) FOR PROVISION OF MODERN STORE HOUSE FOR PAINTS AND CHEMICALS AT MO (MBI), GHATKOPAR
Sl. No. Item Description
1SCHEDULE 'A' PART- I BUILDINGS & STRUCTURES INCLUDING INTERNAL & EXTERNAL SERVICES AS DEFINED IN ANNEXURE I TO IX (EPC)
2Design & Construction of MODERN STORES HOUSE FOR PAINTS AND CHEMICALS (storage accn in G+2) including internal services with permanent specification all as provided including stairs, lifts, lift operator room, meter room, false ceiling work, terrace water tank including (i) construction of UG sump for fire fighting and fresh water combined with permanent specifications(ii) Construction of pump house building and substation building including internal services complete as detailed in scope of work, drawings and other documents of tender, complete all as specified and directed.
3SCHEDULE 'A' PART-II (EXCAVATION & EARTHWORK) Total of Sch-'A' Part-II B/F
4SCHEDULE \\"A\\" PART-III (DEMOLITION & DISMANTLING)Total of Sch-'A' Part-III B/F
5SCHEDULE \\"A\\" PART-IV (ROAD /PATH/ CULVERT/ HARD STANDING )Total of Sch-'A' Part-IV B/F
6SCHEDULE 'A' PART-V (SEWAGE DISPOSAL)Total of Sch-'A' Part-V B/F
7SCHEDULE 'A' PART-VI (AREA DRAINAGE)Total of Sch-'A' Part-VI B/F
8SCHEDULE 'A' PART-VII (TRENCH) Total of Sch-'A' Part-VII B/F
9SCHEDULE 'A' PART-VIII (EXTERNAL ELECTRIFICATION)Total of Sch-'A' Part-VIII B/F
10SCHEDULE 'A' PART-IX (EXTERNAL WATER SUPPLY ) Total of Sch-'A' Part-IX B/F
11SCHEDULE 'A' PART- X (MISCELLANEOUS ITEMS)
12DEMOLITION /DISMANTLING
13Taking down unserviceable Aluminium twin core cable of size 6 sqmm complete.
14Taking down unserviceable various size and types of unserviceable MCB DBs/ main switch etc. complete
15Removal of debris obtained from demolition of bldg and depositing it outside MoD Land
16EXTERNAL ELECTRIFICATION
17Supply and fix adapter panel rated 11 KV/630 Amps ,3 ph, with Copper Bus Bar (R-Y-B) for direct bus coupling to the existing VCB in existing sub Station.Note: Copper BUS BAR in the adapter panel shall be directy coupled to the VCB with BUS-to- BUS coupling and not accepted by any cable or through HT fuse and contractor shall visit the site to inspect the RMU for manufacturing the adaptor before placing the order complete all as specified and directed
18Supply, installation, testing and commissioning step down Transforner, indoor type, HT - 11 KV, 3 Phase, L T- 433 Volts, S0 Hz, 3 phase 4 wire, oil cooled, Level-2, electrolyte grade copper in accordance with vector group DYN11 with neutral brought out on LV side with wound tapping on HV side to vary secondary voltage up tot 7.5 % in steps of 2.5% with externally operated off load type tap changing switch, locking arrangement & digital winding temperature meter complete with all standard fittings all as specified of capacity 315 KVA and confirming following technical specifications:
19a) Rating: HV-11 KV, V- 433Voltb) Winding connections: HV-Delta, LV-Starc) Tappings on HV: ± 2.5%, total= 7.5%, OFF Circuit linksd) Insulation class -'H'%e) Applicable Standards- IS:1180 /EC-76f) Termination: (i) HV & LV cable bok or outside for easy connectiong) HV & LV cable glands of standard rating incl cable end boxes on both sides. h) Noise level: Less than 69 db at 1 mtr.j) Full load losses: within the permissible as per latest IS-1180k) No load losses: within the permissible as per latest IS-1180l) Protection Device:m) Protection relay against temperature rise to trip VCB and alarm be also provided to sound during high temperature of winding n) Surge protection Protection against over current and earth fault.NOTE:(i) Contractor shall submit the technical drawing, Constructional drawings, safety features drawing etc. for approval of accepting officer.(ii) The contractor shall intimate for factory inspection for routine tests as per 1s & ANSIC-57.12.90 (Latest revision) in the OEM factory in presence of rep nominated by accepting officer before despatch from factory. Tests after installation shall also be carried out through SEI for which GE will intimate through proper channel.
20Supply,install, test and commission, Indoor type ,LT panel box ,cubicle type, factory fabricated,CPRI approved ( any company from list of make), panel board made with 2 mm thick CRCA Sheet , weather and vermin proof ,floor mounted ,Class 7 tank process ,powder coated in siemens gray colour inside and outside, 3 phase, 4 wire system copper bus bar mounted on hygroscopic insulator housed in separate bus bar chamber covered with R-Y-B and black PVC heat shrinkable sleeve, with 50mmx50mmx6mm angle iron frame with and including PCC 1:3:6 type C2 foundation and covering front and back opening hinged door along with suitable locking arrengement including necessry bus bar tappings, copper control wiring of required size, connecting cable with necessary cable glands, lugs etc, independent chamber to accomodate the MCCBs MCBs,measuring instruments,Bus bar and cable gallary chember ,proper arrangements for ventilation complete with provn for connecting earthing at both sides of panel board and comprises as following:- (MAIN PANEL)
21BUSBAR 800A Rated copper bus bar with color coded shrinkable sleeve INCOMER Air circuit breaker 4 pole 630A, 415V, 50 Hz, 50KA - 01 No OUTGOING MCCB 4P 400A, 415V, 35KA -01 No (AMF panel through Utlity) MCCB 4P, 125A, 415V, 25KA -3 Nos. (For FLP Bldg panel) MCCB 4P, 250A, 145V, 25KA - 1 Nos. (For APFC pannel) MCCB SPN, 10 Amp, - 02 Nos. (Sub stn lighting) METERING & INDICATION Ammeter, Digital type, with suitable CTs - 01 set voltmeter, Digital type -01 set, R-Y-Bphase indicating lamp - 01 set, Multifunction meter -01
22Supply, install, test and commission, Indoor type ,LT panel box ,cubicle type, factory fabricated,CPRI approved ( any company from list of make), panel board made with 2 mm thick CRCA Sheet, weather and vermin proof, floor mounted, 7 tank process ,powder coated in siemens gray colour inside and outside, 3 phase, 4 wire system copper bus bar mounted on hygroscopic insulator housed in separate bus bar chamber covered with R-Y-B and black PVC heat shrinkable sleeve, with 50mmx50mmx6mm angle iron frame with and including PCC 1:3:6 type C2 foundation and covering front and back opening hinged door along with suitable locking arrengement including necessry bus bar tappings, copper control wiring of required size, connecting cable with necessary cable glands, lugs etc, independent chamber to accomodate the MCCBs MCBs,measuring instruments,Bus bar and cable galley chamber, proper arrangements for ventilation complete with provn for connecting earthing at both sides of panel board and comprises as following :- (UTILITY PANEL )
23BUSBAR 100 Amps copper bus bar with color coded heat shrinkable sleeve INCOMER MCCB 63 Amp 4 pole 415V 25KA (I/C) OUTGOING MCB TPN 63 Amps - 03 Nos(02-pump +01 spare) FASD starter for 5 HP pump set with protection single phase over load and under voltage, 415V, 50HZ suitable for electric driven pump set - 02 Nos MCB SPN 16 Amps -01 Nos (pump house lighting) METERING & INDICATION Ammeter, Digital type, with suitable CTS - 03 set, voltmeter Digital type - 03 set , R-Y-B phase indicating lamp - 03 Nos
24Supply,install, test and commission, Indoor type ,LT panel box ,cubicle type, factory fabricated,CPRI approved ( any company from list of make), panel board made with 2 mm thick CRCA Sheet , weather and vermin proof ,floor mounted ,Class 7 tank process ,powder coated in siemens gray colour inside and outside, 3 phase, 4 wire system copper bus bar mounted on hygroscopic insulator housed in separate bus bar chamber covered with R-Y-B and black PVC heat shrinkable sleeve, with 50mmx50mmx6mm angle iron frame with and including PCC 1:3:6 type C2 foundation and covering front and back opening hinged door along with suitable locking arrengement including necessry bus bar tappings, copper control wiring of required size, connecting cable with necessary cable glands, lugs etc, independent chamber to accomodate the MCCBs MCBs,measuring instruments,Bus bar and cable gallary chember ,proper arrangements for ventilation complete with provn for connecting earthing at both sides of panel board and comprises as following:- (WATER SUPPLY PUMP PANEL)
25BUSBAR 100 Amps copper bus bar with color coded heat shrinkable sleeve INCOMER MCCB 63 Amp 4 pole 415V 25KA (I/C) OUTGOING MCB TPN 63 Amps - 03 Nos(02-pump +01 spare) FASD starter for 5 HP pump set with protection single phase over load and under voltage, 415V, 50HZ suitable for electric driven pump set - 02 Nos MCB SPN 16 Amps -01 Nos (pump house lighting) METERING & INDICATION Ammeter, Digital type, with suitable CTS - 03 set, voltmeter Digital type - 03 set , R-Y-B phase indicating lamp - 03 Nos
26M&L for 3 Core 1.5 Sq mm size multistranded copper conductor PVC unsheathed 650 / 1100 Volt Grade drawn in through steel tubular poles, for interconnection of cable looping box to Street Light Fitting
27Supply, installation, testing and commissioning of factory made,CPRI approved Flamproof/ explosion proof indoor cubical compartmental type indoor building panel(TTA),with provision & arrangement of glass window for MFM meter panel,AI die cast LM6, ingress protection:-IP66, Gas Group:-IIB,certified by CIMFR Dhanbad & PESO Nagpur should be Ex-d standards IS/IEC 60079-1 panel should be design for hazardious classification area zone-1. suitable size for short circuit , temprature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1&2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP66 protection made out of 2.0mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, inclunding earthing stud, labelling , painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process ), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6mm thick mild steel vitreous enameled (white) with letters , figures and conventional skull and bones in signal red colour suitable for 3-phase , four wire system , 500V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete (Flame Proof Bldg Panel).
28The INDOOR BUILDING LT PANEL shall comprise of the following:[A]BUSBAR CHAMBER[1] 01 set (3L+N) of copper busbar of rated capacity 200 A, covered with PVC insulated sleeves including insulator, nuts,bolts, etc. with complete connection[B] INCOMING[1] 125A, 415V, lcs=100% lcs=25kA, 50Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7-1*ln), adjustable short-circuit setting (5-10*lr) adjustable neutral protection (N,N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)-01Nos.[2] Cl 1.0 multi -function meter capable of measuring V,A,F, PF,W/VA , Wh /Vah , Runhrs. Onhrs & interupts -01 Nos.[3] LED phase indicators (Red, Yellow,Blue)-01 Set[C] OUTGOING32A,415V,lcs =100% lcu =16 kA, 50Hz 4P MCCB, conforming to IEC 60947-2, having m trip unit, adjustable overload setting (0.7-1*ln), adjustable circuit setting (5-10*lr) adjustable neutral protection (N,N/2, OFF), front indication LEDs (ready, overload and pre- alarm & overload)- 03 Nos. [ for DB-1, DB-2, DB-3].Ammeter, Digital type, with suitable CTs-03 setVoltmeter, Digital type-03setR-Y-B phase indicating lamp- 03Nos.
29Supply and fix octogoanal HT GI poles type 410 SP-31 (9 meter long) complete with MCB SP 6 Amp arrangments Gl base plate and finial including foundation and coping complete all as specified and directed.
30Supply and fix obstruction (aviation) light LED type, comprising of high aluminium alloy housing, AC 220V, Flash frequency 15-16 per min, colour Red, IP65, LED rating 30-50 W, polycarbonate enclosure complete fixed on roof with GI tubing as suitable size, upto length 1.2m, incuding fixing arrangments complete all as specified and directed.
31Supply and fix cable PVC insulated 1100volts grade with stranded copper conductor of size 3 core 2.5 sqmm cable in and including PVC conduit fixed on wall/roof wall/roof with suitable saddles, spacer, screws etc complete all as specified and as directed. (for Aviation light)
32Supply and fixing Factory made sheet metal encloser MCB DB SPN 230 Volts 4 way, double door complete with neutral link including MCB C curve 10 KA, SPN 6-32 16 AMP - 2 Nos fixig with surface/ wall complete all as directed.
33Supply & Fix HT Cable route indicator made out of cast iron 10 cm dia duly engraved with letters 'HT CABLE 11000 Volts\\" fixed in 20mm X 20 mm equal angle 0.5 mtr long icluding provision of PCC foundation/ block 1:2:4 of 20 cm X 20 Cm X 20 cm complete all as specified and directed.
34Supply, install, testing and commissioning of indoor 11 KV HT switch gear, extendible type, vertical isolation and horizontal draw out, vacuum circuit breaker (VCB), rupturing capacity 350 MVA, 630 Amps, with DC tripping arrangement mounted on structural steel frame outdoor type with separate indoor control panel with over current and earth fault relays of suitable rating and each fitted with following :- (a) 3 Nos vacuum interrupters of rating 11 KV, 3 phase, 50 Hz, 350 MVA, 630 Amps mounted on common base segregated epoxy body for higher e!ectrical insulation and to maintain pole discrepancy as per IEC 56 and self aligned type isolating contacts, manual and motor operating (230 volt AC ), spring charged mechanism, manual closing and tripping push buttons, mechanical operation counter 8 N0+8NC breaker operating auxiliary switch, spring charge /discharged indication, circuit breaker service /test position indication all as directed - 1 No. (b) Self powered microprocessor controlled numeric relay comprising of two over current, one earth fault protection relay with high set for both phase and earth with fault memory, universal auxiliary supply. All as per IS:3231' 88686. The setting for over+B19 current shall be 50-200% of SA (in the step of 10%) and for earth fault element from 20- 80% of SA (in the step of 10%). (c) 1 No. 96 Sqmm flush pattern digital ammeter (0 - 1 OOA) suitable to CT ratio. Make: AE / MECO / L&T / Secure / C&S(d) 1 No. 3 way and OFF ammeter selector switch for reading the current in any phase on the above ammeter. (e) 1 No. 96 sqmm flush pattern digital voltmeter (0-12 KV) suitable to the CT ratio. Make - AE / MECO / L&T / Secure / C&S batteries complete suitable for protection I operation of relays-01 No.(f) 1 No. 3 way and OFF voltmeter selector switch for reading the voltage between two phases on the voltmeter
35(g) 1 No. AC static, HT, Tri vector meter. Meter should be upplied with Backlit LCD/LED display of measured value shall be displayed on seven segment, seven digit liquid crystal display (LCD/LED) Display unit / register. (h) Cast resin current transformer 11 KV dual ratio 1 00- 50/5/Amp, 15 VA I 5P 10 for protection- 3 Nos. 0 Cost resine potential transformer dry type having minimum 200 VA burden ratio 11 KV /110 V with HT and L T fuses -set of three-01 No (j) Power pack equipment with backup for 15 minutes including maintenance free. (k) Set of LED indicating lamp operating at 110 V single phase as below:- (i) RED /GREEN- VCB ON-OFF indication,(ii) Amber:- Trip indication,(iii) White:- Trip circuit healthy indication with push button,(iv) BLUE:- VCB mechanism spring charged indication (l) One set of heat shrinkable PVC sleeved, 400 amps copper busbar-1 set(m) 1 No. strip heater-1 00 watt(cotinuosly rated) with thermostate with manual ON-OFF switch-1 set(n) Structural steel frame including PCC fdnan<;l earth work as per manufacturer specification.(o) 1 No 3 way breaker control switch with positions TRIP- NEUTRAL -CLOSE(p) Manual charging/ operaing arrangment.(q) Fuses for metering and protection system(r) (i) Auto trip(ii) Motor /manual charged spring operating /closing mechanism.(iii) Fault alarm (iv) Manua tripping(s) Complete control panel wiring with suitable size copper e(t) Test Terminal Block (TTB) to test meters and relays with sealing arrangement.
36Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, indoor type, APFC capacitor bank Panel Board of size as recommended by manufacturer 150 KVAR with 5 steps (50+50+25+12.5+12.5), Suitable for Auto and manual operation with MD-XL Capacitor and MCCB as inccomer. Automatic Power Factor Correction panel , made out of 2 mm thick CRCA Sheet Dust and Vermin Proof, single door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, The enclosure shall be re-treated as per 11 tanks process and finished with powder coating of shade RAL 7032. , including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 300 mm above the Normal Ground Level and 300 mm below ground complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Testing after Installation complete all as specified. The panel shall be factory fabricated comprising of following. INCOMER MCCB 400 A 35 KA, 4 POLE, thermal magnetic release, lcs=100% leu - 1 no (Thermal Magnetic Release) OUTGOING CAPACITOR FEEDERS :- Capacitor feeder comprising of 50 KVAr x 02 Nos + 25 KVAr x 01 No + 12.5 x 02 Nos. Suitable rating MCCB/MCB TP of D curve for capacitors, 7% Detuned Aluminium Reactors 440V, Ultra heavy duty capacior L TXL, BOX type oil Filled Capacitor banks, Push Buttons ON/OFF, Indicating lamps lncomer Metering APFC relay 6 stage Digital Voltmeters (3Ph, Class 1 )-01 No, Digital Ammeter (3Ph, Class 1, 5A) -1 NO Metering CT --/5A, Class-1- 3 NOS Auto Manual selector switch -1 NO
37EXTERNAL WATER SUPPLY
38Cutting existing Cl pipe size upto 150mm dia for branch connection of 80 mm dia Gl pipe incl cutting extg Cl 80 mm dia pipe and insertion of tee 150x150x80 mm dia and connecting complete incl cutting extg pipe threading and inserting TEE and Nipple and Union of 80 MM dia incl all required excavation and earth work complete all as specified and directed.
39Supply and fix foot valve conforming to IS:4038 50 mm dia.
40Supply and fix Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Cast Iron Water supply mains of size 50 mm dia
41Supply and fix 4 Sqmm 3 Core round copper conductor Cable PVC insulated using starter panel to pumps and motors complete all as directed.
42M&L for Construction of brick masonary valve chamber of size 0.9m x 0.9m x 0.9 mtr (internal dimension) above ground level 30 cm suitable for 100 mm dia sluice valve, 15 cm thick foundation using PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate ) over 15 cm thick hardcore, 23 cm thick brick wall , built in cement and sand mortor 1:4, 15 cm thick internal and external plaster including top of floor in cement and sand mortor 1:3, finished even and smooth, without using extra cement, 10 mm thick mild steel plate cover on 50 mm x 50mmx6 mm MS angle iron frame embeded in PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) coping , having rectangular hinged opening of size with locking arrangement & handle made out of 25 cm dia MS round bar , hold fasts etc, applying one coats od red oxide primer and two coats of synthetic enamel paint to all steel surfaces and earth work in any type of soil including disposal of surplus soil to a distance not exc. 50 mtr or as directed by Engr-in-charge complete.
43M&L for Construction of brick masonary valve chamber of size 0.9m x 0.9m x 0.9 mtr (internal dimension) above ground level 30 cm suitable for 100 mm dia sluice valve, 15 cm thick foundation using PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate ) over 15 cm thick hardcore, 23 cm thick brick wall , built in cement and sand mortor 1:4, 15 cm thick internal and external plaster including top of floor in cement and sand mortor 1:3, finished even and smooth, without using extra cement, 10 mm thick mild steel plate cover on 50 mm x 50mmx6 mm MS angle iron frame embeded in PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) coping , having rectangular hinged opening of size with locking arrangement & handle made out of 25 cm dia MS round bar , hold fasts etc, applying one coats od red oxide primer and two coats of synthetic enamel paint to all steel surfaces and earth work in any type of soil including disposal of surplus soil to a distance not exc. 50 mtr or as directed by Engr-in-charge complete.
44STAND BY DG SET
45Supply,lnstallation,Testing and Commissioning of Silent DG Set complete, 415V, 50Hz AC of capacity 250KVA conforming to IS : 10002- 981complete with Diesel Engine of suitable BHP & AC Brushless SPDP alternator, conforming to IS: 13364-1992, mounted on a common base frame & coupled through a flexible coupling or close coupled complete with platform,control panel having meters, sound-proof canopy with acoustic enclosure,automatic starting on main failure (AMF} as per CPCB-IV Norms directly coupled to alternator brushless type, Electronic AVR and Governer,Voltage regulation ±1% complete with Std control panel having all type of meters, fuel tank, fuel line system,suitable foundation, etc of capacity upto 250KVA all as per the specif ications given below, all as specified and directed by Engineer-in-charge.
46(A) DIESEL ENGINE: Diesel engine having minimum output 303.4HP/ 223KW with prime rated power as per ISO 8528/1, speed 1500 RPM, six cylinders with turbocharged and air to aircooled,closed circuit radiator cooled cooling system, electric starting system with 12 volt DC electric starting motor,electronic governor,full automatic electronic fuel injuction system with electronic governing having ECM system for perfect control of fuel and air ratio having protections LLOP, HWT, Iow coolant level, high canopy temperature, engine over speed, engine overload, etc with following items like in built fueltank of approx capacity 385 ltrs, Lube Oil Consumption : +or- 0.06% of SFC, AH Capacity : 180 AHtropical radiator with cooling fan, after cooler, lub oil cooler, turbocharger, fresh water pump, electronic fuel injucting pump, 12 volt DC electric Starting motor, dry type air filter, double bowl fuel filter, spin-on-type lube oil filter all as per the recommendations of manufacturer.(B) ALTERNATOR: Alternator of rating 250KVA/200KW, 415 volt AC, 3 phase, 4 wire system on 50Hz frequency and speed 1500 RPM at power factor 0.8 (Lag) having class \\"H\\" insulation for both rotor and stator with IP23 screen protected, drip proof and conforms to BS SOOO, IS 4722 and IEC34 standards and brush less, self excited, self regulated excitation and suitable for a permissible over load of 10% for one hour in 12 hrs test run and all as per there commendations of the manufacturer and all as specified and as directed by Engr-in-charge. (C) ACOUSTIC ENCLOSURE : M & L for acoustic for the above 250 KVA DG set to reduce noise level to 75 dB measured at 1.0 distance for audible frequencies as per guidelines of Central p[ollution Control Board as manufacturer's specification and commissioning of follwing from authorised OEMs of Gen Set Manufactures Specified:- (i) Sound insulation : 100 mm thick Rock wool (density 64 KG/Cum)(ii) Outer body : 1.6 mm thick CRCA(iii) Door : 1.6 m thick CRCA(iv) Innar asaurface : 1.0 mm thick CRCA/ GI sheet(v) Base Frame :ISMC 300(vi) inside illumination : 1 no - 1 x 18 wat FTL fitting
47(D) Automatic Main Failure (AMF) control panel:- Indoor type, factory fabricated cubical type, free standing, floor mounted, AMF control panel with all necessary connections complete, provided with removable rear door & hinged front door for easy accessibility, fabricated out of not less than 2.0 mm thick CRCA Sheet powder coated CPRI approved comprising of following :-(i) AMF control circuit with 4 pole, MCCB 320 Amps cu of 35/36 kA at 415 volts - 02 Nos micro processor based with thermal and magnetic release setting 70% to 100%. each one for Main supply and DG set supply incoming supply with HRC back up fuse complete with all DC control relays/line voltage monitor (LVM) as per OEM specifications incorporating engine start and stop complete as specified and directed.(ii) Digital ammeter (0-500 amps) and voltmeter (0-500 Volts) with selector switch(iii) Digital frequency meter.(iv) Digital power factor meter (-1.0 to +1.0)(v) Indicating lamps for supply \\"ON\\" and Load \\"ON \\"(vi) Instrument fuses (HRC type)(vii) Push button 01 No each for start, stop & reset (Viii) Copper busbar of capacity 200 amps. for phases and neutral (ix) Bottom gland plate including glands for incoming and outgoing LT cables(x) Circuit diagram plate (xi) Automatic battery charging unit including facility for over charging stop /trickle charging /boost charging 12 volt complete with DC ammeter, DC voltmeter, Charging set selector switch, (xii) Facility for remote / auto start, auto/manual synchronizing ,audio-visual annunciation and indication lamps for engine fault (E) Civil Work :-All civil work related to foundation for DG set and installation of panel and equipment and depth of foundation shall be minimum 300 mm with antivibration pads, or as recommended by the manufacturers. Cables from DG set to AMF panel to main panel will be measured under relevant schedule.Note:- The fuel for final testing of 12 hours shall be supplied by the contractor and cost deemed to be included in the above offer. All other necessary equipments like resistance load strip heater of suitable capacity/rating and any other items required for final testing shall be provided by the contractor without any extra cost to department.
48Comprehensive maintenance and repair of fully automatic electrically operated 3000 kg Goods Lifts (Total Nos 02) of any make, type installed in the subject project as per schedule given above with single speed motor and AC variable voltage and variable frequency (VVVF) and ARD complete with all standard accessories, automatic and manual dual controlled operation, centre openable doors with door drive (Electric motor driven mechanism), sliding steel doors, complete all as specified and directed.Notes:- (i) Rates quoted under Sch 'A' shall be for both materials and labour complete unless mentioned otherwise.(ii) After expiry of the defects liability period of 24 months from the certified date of completion of work, Government reserves the right to order the contractor to carryout comprehensive maintenance services of the lift (provided by him under Sch A in accordance with terms and conditions detailed in Sch A and specifications enclosed thereof in the event of Govt. exercising the above right, the terms of comprehensive maintenance service contract of the lift shall be three years from the expiry date of the details liability period.(iii) The contractor shall enter in to a MOU with the OEMs for the provision of the lift and further maintenance. The MOU for the post warranty/post defect liability period between the contractor and OEM shall be submitted at least six months prior to the issue of completion certificate of the main contract.(iv) The rate quoted under this Sch A shall be deemed to include for materials and labour required for comprehensive maintenance including repairs.(v) The work covered under Sch A will be ordered on the contractor by the respective Garrison Engineer on every year through a separate works order for the lifts installed in their area at the rate quoted by the contractor till completion of three years comprehensive maintenance.(vi) This contract shall be operative for the period of three years after expiry of defect liability period only for the purpose of comprehensive maintenance.(vii) In case of non function of lift recovery shall be effected after the defect is noticed or notified either in writing or through a social media message by GE or his rep in terms of PS clauses mentioned in the tender.
49One year after expiry of defects liability period
50One year after completion of BoQ Sl. item No. 40.00 here-in-before
51One year after completion of BoQ Sl. item No. 41.00 here-in-before Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56580056
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 20.62 Crore
LAST DATE 25-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Engineering, Procurement & Construction (Epc) For Provision Of Modern Store House For Paints And Chemicals At maintenance of (Mbi), Ghatkopar
Basic Detail
Tender No 87966/E8
Bidding Type Tender
Location
City Mumbai Suburban
State Maharashtra
Key Dates
Publish Date 21 Jul 2026
Submission Date 25 Aug 2026
Open Date 27 Aug 2026
Finance
Tender Value 20.62 Crore
Tender Fee 3000
EMD 13.56 Lakhs
Exemption Available
Document List
06ba60fd-d563-4388-8ad4-a717c25665d9.html
87966Drawings.pdf
87966TenderPages.pdf
BOQ_873481.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Aug 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
html

06ba60fd-d563-4388-8ad4-a717c25665d9.html

pdf

87966Drawings.pdf

pdf

87966TenderPages.pdf

xls

BOQ_873481.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail