Tender For Day To Day Maintenance Work At Shri Haridev Joshi Govt. Hospital,Dungarpur (Raj.)
Tender Value
65.65 Lakhs
Estimated cost
Bid Submission
28 Jul 2026
4 days left
EMD
1.31 Lakhs
Bank guarantee accepted
Document Fee
1500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dungarpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Day To Day Maintenance Work At Shri Haridev Joshi Govt. Hospital,Dungarpur (Raj.)
BOQ
| Sl. No. | Item Description |
| 1 | Civil workEarth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed within a lead of 50 meter. All kinds of soils |
| 2 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering andshuttering - All work up to plinth level.M15 grade Nominal Mix 1: 2: 4 (1cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 3 | M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 gradedstone aggregate 20mm nominal size). |
| 4 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in Cement mortar 1 :6 (1 cement : 6 coarse sand) |
| 5 | Half brick masonry in Superstructure , above plinth level upto floor V level using bricks of designation 75 Cementmortar 1 : 4 (1 cement : 4 coarse sand) |
| 6 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement: 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. Jhunjhunu / Jalore (Red/Choclate/Black/Pink Colour)Above 3601 Cm2 Slabs |
| 7 | Extra for providing edge moulding to 15- 18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite/Kota Stone Work Full Edgemoulding |
| 8 | Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to code IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including thecost of cement mortar bed 1:4). |
| 9 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to code IS : 15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cementplaster on walls and pillar). |
| 10 | P & F 1st quality Heavy Duty Vitrified Double Charged tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. size600 mm X 600mm |
| 11 | Add extra for Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477 , using 5kg. adhesive per sqm of tile area, in average 3mm thicknessinstead of cement mortar. |
| 12 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm thick nominal sizeaggregate. |
| 13 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) Medium shade using approximately 50% white cement and 50% ordinarycement. |
| 14 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish20mm thick. |
| 15 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1cement : 4 coarse sand) |
| 16 | Making holes in stone masonry wall upto 450 mm x 450 mm size andmaking good in CM 1:6. |
| 17 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. 1: 3: 6or richer mix. |
| 18 | Dismantling tile work in floors and roofs laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meter lead For thickness of tiles 10mm to25mm. |
| 19 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50meter lead. |
| 20 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of : Ist course of applying cement slurry @ 4.4 Kg/sum mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.IInd course of 20mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water. proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface..IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg per sqm. of area.IVth course of 400 micron thick PVC sheet .(Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.) |
| 21 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. laying second layer of Fiber glass cloth when the first layer is still green . Overlaps of joints of fiber cloth should not be less than 10 cm . Third layer of 1.5 mm thickness consisting of slurry of cement @1.289 kg/sqm mixed with water proffing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around fourth and final layer of brick tiling ‘with cement mortar or any other approved protective coarse. (which will be paid for separately) For the purpose of measurement the entire treated surface willbe measured |
| 22 | Repair to damaged RCC slabs, beams and columns etc for strengthening with cement mortar 1 : 2 in following steps :-Choping losse and cracked concrete to required depth, cleaning the exposed surface of steel and concrete with wire brush and sand papering , cleaning of concrete surface with water as necessary and getting dried.Applying Epoxy primer on the exposed steel bars.Applying Epoxy hardener and resin mix (as per manufectured's specification) on concrete and steel bars with brush.Speading dry cement mortar 1 : 2 mix over epoxy treated wet surface and allow it to dry for one day.Plastering the surface with cement sand mortar 1 : 3 upto depth of 30mm complete.Cure the plastered surface for 15 days, All work including scaffolding etc. complete in all respect. |
| 23 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786)Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 24 | 6 mm thick cement plaster to ceiling ofmix 1:3 (1cement : 3-fine sand) |
| 25 | Cement plaster 1:3 under old stone slabs with admixture (gur,nails,binding wire to mesh and scraping scales & dressing joints of slabs complete.Proofing upto 25 mmthickness. |
| 26 | Supply of Mistry |
| 27 | Supply of Portland Cement |
| 28 | Supply of White Cement |
| 29 | Supply of Bajri |
| 30 | Supply of Stone Aggregate (Single size): 10 mm nominal size |
| 31 | Supply of Stone Aggregate (Single size): 20 mm nominal size |
| 32 | Carriage of Building Rubbish Stone metal (Grit and ballast etc.) including loading andunloading with lead of 20km. |
| 33 | Sanitary WorkP & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS:2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor Size580x440mm. |
| 34 | P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall andfloor |
| 35 | P & F water closet Seat Covers with brass hinges complete Solid PVC (IS2548 marked) grade-I White. |
| 36 | Labour charges for removing W.C. pan(any type) of all sizes with care including all necessary fittings P or S trap. |
| 37 | Add extra if C.I.P trap is used in place ofVitreous china P trap for W.C. |
| 38 | P & F W.V.C. Half-Round Channel of approved make in C.M. 1:3, joints finished in white cement of Size100mm dia. |
| 39 | P & F W.V.C. (IS: 2556 Mark) Squatting Urinal of standard make complete. Including cutting & making good thefloor Size 450x350mm |
| 40 | P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittingsC.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall PVC with PVC bend and superiorinternal fittings as per IS : 7231 . |
| 41 | P & F Flush Pipe of approved make with complete fittings for high level flushing cistern G.I. `B` class (Concealed) 32mm. |
| 42 | P & F WVC (10 litres) low-level flushingcistern cover only |
| 43 | P & F WVC syphon with plunger plateonly. |
| 44 | P & F C.P. brass Urinal Spreader forstall urinal of approved make. |
| 45 | P & F C.P. brass Doom Waste Coupling32 mm dia. |
| 46 | P & F C.P. brass Doom Waste Coupling40 mm dia. |
| 47 | P & F Plastic Syphon of approved makefor automatic flush tank. |
| 48 | Removing and re-fixing of wash handbasin including all necessary fittings. |
| 49 | P & F metal brackets duly painted including cutting & making good thewall. |
| 50 | P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make withC.I. brackets duly painted 1 No. 15 mmC.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete includingcutting & making good the wall :Size 610 mm x 510 mm |
| 51 | P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor WVC Lab sink (IS:2556mark) size 530 x 430 x 180 mm |
| 52 | P & F Bottle Trap of approved make C.PBrass 40 mm |
| 53 | P& F waste Coulping with fittings ofapproved quality /make:C.P Brass 40 mm dia |
| 54 | C.P. Brass 50 mm dia |
| 55 | P.V.C. with C.P. nut 40 mm dia |
| 56 | G.I(B class) 40 mm |
| 57 | P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed towooden screws & washers. Other sizes |
| 58 | P & F Looking Mirrors with P.V.C. frameof approved make as per direction of Engineer-in-charge Round 500mm dia |
| 59 | P & F Towel Rail or Ring of approvedquality/make:C.P. brass towel rail with brackets 600x 20mm. |
| 60 | C.P. Brass Towel Ring revolving type |
| 61 | P & F Grating of approved quality/makeStainless Steel Sheet size 125mm dia. Heavy Quality of approved make |
| 62 | P & F Liquid Soap Container with brackets complete of approved makeC.P. brass |
| 63 | P & F Soap Dish or Tray of approved quality/make C.P. brass heavy andsuperior quality. |
| 64 | P & F Extension Pipe for bib cocks of approved quality/make. C.P. brass ofHeavy & Superior quality 150 X 15mm. |
| 65 | Labour Charges for removing WVCpan:Indian/Orissa pan |
| 66 | European W.C. |
| 67 | Flushing cistern |
| 68 | P & F Jet spray for water closet withC.P. Copper Tube flange of approved make. |
| 69 | Providing & fixing C.P.flange for 15mmdia taps. |
| 70 | C.P. Pillar cock, Swan-neck with casted spout, 15mm nominal bore. |
| 71 | C.P. Pillar cock Elbow action, 15 mm nominal bore. |
| 72 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall)15 mm nominal size |
| 73 | 20mm nominal size |
| 74 | 25 mm nominal size |
| 75 | 32mm nominal size |
| 76 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.(External work).15 mm nominal size |
| 77 | 20mm nominal size |
| 78 | 25 mm nominal size |
| 79 | 32mm nominal size |
| 80 | P & F Bib Cock (IS : 8931 Mark),Superior quality of approved make:C.P. Brass bib cock,15mm nominalbore. |
| 81 | C.P. Brass Long body, 15mm nominalbore weight not less than 690 gm |
| 82 | C.P. Brass Elbow-action, 15mm nominalbore. |
| 83 | Synthetic Material(PTMT) bib cock of approved quality/ make, Long Body, 175mm long |
| 84 | P & F Stop Cock (IS :8931 Mark),superior quality & of approved make:Brass 400 gm. 15mm nominal bore. |
| 85 | P & F Ball Cock (IS :1703 Mark) withRod & P.V.C. Ball complete :Brass wt.Not less than 600 gm, 25mm. |
| 86 | P & F Inlet Connection (Angle Valves)Superior quality, of approved make, for Wash basin, Gyser etc.C.P. Inlet connection 15mm.Brass (IS :8931 marked) |
| 87 | Synthetic Material (PTMT) Inlet connection of approved quality/make 15mm nominal size. |
| 88 | P & F 15 mm. Dia Connection Pipe of approved quality/make PVC pipe withC.P. Brass nuts upto length, 600mm. |
| 89 | P & F Flush Cock / Flush Valve (IS : 9758 Mark) for WC of approved quality make CP brass 20mm nominalbore. |
| 90 | P & F Full-way Valve (IS:778 Mark) orwheel valve of approved make :Gun-metal 15mm nominal bore. |
| 91 | Gun-metal 25mm nominal bore. |
| 92 | Gun-metal 50mm nominal bore. |
| 93 | P & F Mixing Range (15mm)C.P. One hole/close hole basin mixerwith swinging spout casted. |
| 94 | C.P. sink mixer With casted spout. |
| 95 | C.P. wall mixer without crutch &telephonic shower. |
| 96 | P & F PVC Storage Tank ISI Marked (IS: 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design:1000 litres capacity. |
| 97 | Hoisting Charges for each floor :500 Above Litt. |
| 98 | 1000 below Litt. |
| 99 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good thewalls etc.,)15 mm nominal size |
| 100 | 25 mm nominal size |
| 101 | Providing and fixing superior quality PVC Tank Cover complete as perapproved by Engineer In Charge500 Lt. capacity |
| 102 | Above 500 Lt. capacity |
| 103 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality/make including joining the pipe with solvent cement rubber ring andlubricant.110 mm dia |
| 104 | 160 mm dia |
| 105 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solventcement rubber ring and lubricant:Coupler (socket) 110mm dia |
| 106 | Coupler (socket) 160 mm dia |
| 107 | Bend 87 .5 110mm dia |
| 108 | Bend 87 .5 160 mm dia |
| 109 | Door Cap 110mm dia |
| 110 | Pipe Clip 110mm dia |
| 111 | Raising manhole cover and frames slab to required level including dismantling existing slab and making good the damage as required (raising depth of manhole masonry to be paidseparately).Rectangular manhole 90x60 cm |
| 112 | Rectangular manhole 150x120 cm |
| 113 | Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m,10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplusearth within a lead of 50 mtr.Inside size 450 x 450mm depth upto0.5 M Cement cover with frame |
| 114 | Supplying and fixing C.I. Cover with frame, C.I. gratings for chambers & manholes. |
| 115 | Supplying and fixing Ferro- cement cover with C.I. frame for chambers& man holes of size.500mm dia 22 Kg.-do-22 MT centrepoint load (Heavy duty). |
| 116 | Construction of Cement Concrete Chamber 125mm dia. C.P. Brassgrating |
| 117 | Construction of Cement Concrete Chamber 125mm dia on depressed floor upto 45cm height from floor with C.P.Brass grating |
| 118 | Cleaning of C.I. Pipe Line of various sizse as per requirement at site of different sizes including 100mm,150mm & 225mm dia of C.I.Pipes as perdirection of Engineer-in-Charge. |
| 119 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50meter lead. |
| 120 | Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50metres lead as per direction of Engineer-in-charge bituminous road (average thickness300 mm) |
| 121 | Making of hole (width up to 150 mm) inR.C.C. slab/wall/beams by power driven drilling machine complete as perdirection of EI upto 150mm thick |
| 122 | Filling of sunk portion of roof with earthen pots of required height including filling voids with 1:3:6 light concrete, using brick bats complete levelling and dressing the surface by 50mm thick cement concrete 1:2:4 as perspecification. |
| 123 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cementcompound consisting of applying :first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @0.253 kg//sqm .This layer will be allowed to air cure for 4 hours. |
| 124 | Finishing with neat cement (punning). |
| 125 | Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete finefinish 20mm thick . |
| 126 | Providing Laying & jointing glazed S.W. pipes grade `A` (IS;651 marked) of approved make with spun yarn & stiff mixture of cement mortar 1:1, excavation & refilling of earth in all types of soil upto 1.2m depth, S.W. fittings, including testing of joints etc, complete.300mm dia |
| 127 | Supply of Plumber |
| 128 | Carriage of Building Rubbish Stone metal (Grit and ballast etc.) including loading and unloading with lead of20km. |
| 129 | Joinery workProviding and fixing aluminum work for doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and the directions of Engineer- in – charge .(Glazing and paneling to be paid for separately).For fixed portion Powder coating aluminum ( minimum thickness of powder coating 50micron) For fixed portion Powder coating aluminum ( minimum thickness of powder coating 50 micron) |
| 130 | For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges/ rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). Powder coating aluminum ( minimum thickness of powdercoating 50 micron) |
| 131 | Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, TypeII conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on otherside. |
| 132 | Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item.) With float glass panes of 5.0 mm thickness ( weight notless than 13.50 kg/sqm) |
| 133 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S.With stainless steel cover plate |
| 134 | Filling the gap upto 5 mm depth and 5 mm width in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction ofEngineer-in-charge complete. |
| 135 | Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc.complete. |
| 136 | Providing and fixing aluminium U shape handle of size 100mm with SS screws etc. Complete as per direction of Engineer-in-charge Powdercoated minimum thickness 50 micron aluminium |
| 137 | Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. |
| 138 | Providing and fixing expanded grill made of aluminum as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminum window/vent with required screws, Y and H aluminium section (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge. Powder coating aluminum ( minimum thickness of powdercoating 50 micron) |
| 139 | Labour Charges for removing and refixing Aluminium Partitions door including minorrepair on alteration in the same. |
| 140 | Providing and Fixing powder coated aluminium angle corners of size 75 x 75 x 6mm over extruded/exposed corners of walls/colom etc. fixed with glazing tape on all four sides including filling of all inside edges of 6mm thickness with weather silicone sealant by backer rod of approved quality to make it completely air tight and water tight over the surface as per dirction of Engineer-in-charge. |
| 141 | Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure 'A' 35 mm thick . CommercialVeneer both side |
| 142 | Extra for providing external lipping with 2nd class teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over itemno. 8.13. |
| 143 | Providing & Fixing mica of approved make for inner/outer side of shutters with fevicol & nails complete as per approved by engineerin charge.0.8mm thick mica |
| 144 | Providing and fixing IS : 3564 marked aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessaryaccessories and screws etc. complete. |
| 145 | Renewing glass panes,with putty and nails wherever necessary Float glass panes ofthickness 4 mm |
| 146 | Repair of door, window shutters including cost of material and labour for change ofdamaged :Panel by Wire Gauge 14 mesh x 24 gauge |
| 147 | Aldrop of mild Steel 12\\" long x12mm dia |
| 148 | Stopper of Aluminium with Double RubberGutka |
| 149 | Door Springs of mild Steel |
| 150 | Steel Hinges For Wooden Chowkhat 4\\" size |
| 151 | Mild Steel Tower Bolt 6\\" long |
| 152 | Removing aluminium/Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed byEngineer-in-charge. |
| 153 | Dismantling doors, windows and clearstory windows steel or wood shutter including chowkhats and holdfasts etc. complete and stacking within 50 meters lead Of areaexceeding 3 square meter. |
| 154 | Providing & Fixing decorative veneer of approved make for inner/outer side of shutters with fevicol & nails complete as per approved by engineer in charge. 6.0mmthick veneer |
| 155 | Repair of door, window shutters includingcost of material and labour for change of damaged :Style / rail of teak wood 30mm thick/Aluminium Section 4\\"wide |
| 156 | Style / rail of teak wood 30mm thick/Aluminium Section 6\\" wide |
| 157 | Labour charges for repair to door / window without using any material such as applying randha (finishing) tighteningof bolts & screw etc. |
| 158 | Repair of existing steel glazed doors, windows and ventilator, MS sheet door, garge doors, compound wall gates etc. by welding drilling complete include. Cost of welding rods and hire charge ofwelding meachine and TP etc complete |
| 159 | Taking out doors, windows and clearstory windows shutters (steel or wood) including stacking within 50 meters lead Of area exceeding 3 squaremeter. |
| 160 | Supply of Carpenter 2nd class |
| 161 | Painting workRemoving dry or oil bound distemper by scrapping sand papering and preparing surface smooth including necessary repairs to scratches by sandla/loi and all scaffolding(for colour changing only) |
| 162 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding Oldwork (One or more coats ) |
| 163 | Providing and applying white cement based putty over plastered surface to prepare thesurface even and smooth completeNew Plastered Surface (three or more coats) |
| 164 | Old Plastered Surface (two or more coats) |
| 165 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding Two or more coats on new work including prepartion of base with primer, putty, lippy etc completein all respect. |
| 166 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on newworkTwo or more coats on new work |
| 167 | One or more coats on old work. |
| 168 | Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty, etc complete in all respect including scaffoldingand safety provision New Work Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysJul 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender