Tender For Construction Of Intake Well, 20 Mld Wtp With Raw Water And Clear Water Rising Main With 24X7 Water Supply To Ward No.4 Naharkanta To Phulnakhara Area Of Bmc Including O&M Period Of 5 Years
Tender Value
52.18 Crore
Estimated cost
Bid Submission
10 Aug 2026
13 days left
EMD
52.19 Lakhs
Bank guarantee accepted
Document Fee
11800
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Cuttack → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Intake Well, 20 Mld Wtp With Raw Water And Clear Water Rising Main With 24X7 Water Supply To Ward No.4 Naharkanta To Phulnakhara Area Of Bmc Including O&M Period Of 5 Years
BOQ
| Sl. No. | Item Description |
| 1 | Design, Drawing, Construction, Testing, Commissioning of Intake well of 8 m dia upto 20 m. depth |
| 2 | Intake Well (upto 20 M depth) including dewatering ,cofferdam, pump house on the well,crane arrangements, 3.5 m wide RCC/ MS walk way - 50 mtr with piling/Column as per requirement of the foundation for walkway to intake pump house but excluding external electrification, raw water pump, approach to site, spur & cutoff wall etc. Including Disposing of excavated material from Intake to the proposed WTP plot.At 8 RM Dia (3.5 m Walk way + 8 Ton EOT) (Transverse and longitudinal Direction) |
| 3 | Elevated substation Platform for transformer,Pannel room (18 Nos. RCC Column 300 mm x 300 mm with 4.85 Mtr. Height) |
| 4 | Earth work in All Type of soil within 50mtr initial lead and 1.5mtr initial lift including rough dressing and breaking of clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3mtr in depth as per direction of Engineer-in-charge. |
| 5 | Excavation of foundation in laterite rock or any hard rock(other than granite or disintegrated rock)removed by chiselling including dressing and leveling the bed not exceeding 1.5mtr depth and depositing the soil within 50mtr initial lead as per specification approved by the Deptt. |
| 6 | Cement Concrete (1:2:4) with 12mm.size crusher broken Granite chips for R.C.C.work (Minor Repair Work)(Depth 1.5m to 3m level) |
| 7 | R.C.C work in ground floor of M-25 grade with 20mm & down grade crusher broken hard Granite chips including hoisting & laying with cost of all labour, materials with all taxes, lead ,T & P etc all complete . |
| 8 | R.C.C work in ground floor of M-25 grade with 20mm & down grade crusher broken hard Granite chips including hoisting & laying with cost of all labour, materials with all taxes, lead ,T & P etc all complete . 1.5 mt to 4.5 m |
| 9 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 10 | Rigid smooth centring and shuttering for R.C.C. works including false work and dismantling then after casting including cost of materials all complete. Foundation and plinth-band,footing,bases of column , mass concrete etc. Shuttering for Depth 1.5m to 3m |
| 11 | Supply & application of EPIDEC Epoxy Painting two coats with any approved paint over a coat of Epoxy primer including cost of all labour, materials T & P with taxes, transportation etc all complete after chipping & cleaning the surface properly. |
| 12 | Proposed Approach BT Road 70m Length @5.50 m Wide |
| 13 | Earth work in all Kind of soil within 50m, initial lead and 1.5m, initial lift including rought dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-charge |
| 14 | Construction of granular sub base by providing closed gradded granular sub base Gradding -IV materials as per table 400-1 spreading in uniform layers with mortor grader on prepared surface, mixing by in place method with rovator at OMC and campacting with vibratory roller to achieve the desired density complete as per clause 401 of MoSRT&H specification for road & bridge work etc complete. |
| 15 | Providing and laying spreding and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the materials with watered at OMC in Mechanical mix plant, carriage of mixed materials by tipper to site, laying inuniform layer with paver in subbase /base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per clause 406 of MoSRT&H specification for road and bridge work (latest revision) |
| 16 | providing tack coat on preppared surface with bitumen emulsion as per technical specification and as per Clause - 503 of MoSRT&H specification for Road & bridge work (latest Revision) |
| 17 | Providing 50 mm thick Bitumen Macadam using crushed stone Gradding II materials & 60/70 penetration grade of bitumen as per approved drawing & technical Specification and as per Clause - 504 of MoSRT&H specification for Road & bridge work (latest Rivision) |
| 18 | Providing 25mm Thick semi Dence Bituminous concrete using crushed stone Gr-II materials & 60/70 penitration grade of bitumen as per approved Drawings & technical Specification and as per Clause 506 of MoSRT&H Specification for Roads and Bridge works (Latest Revision) |
| 19 | Meter Room (5x5) with vitrified floor tile |
| 20 | MS Angle framed Wiremesh Fencing using 50 x50 x 5 mm ,40 x40 x 5 mm MS angle , 25 x 5 mm MS flat & hexagonal wiremesh . |
| 21 | Raw Water Pumping Machinery at Intake Well |
| 22 | Raw Water Pumps -Supplying VT Pump sets with motor suitable for Raw Water application with standard MOC and given duty points as below with motor in Pumset Including Accessories 15m each cable Pumpset Price with cable including LT PMU, Autocoupling with Integral Bend (With Autocoupling PIN)+ Foundation bolt; (Each) CI Body with SS Impeller including column pipe (Kirloskar/Wilo/Grundfos/Equivalent make with approval of the authority)Flow - 145 to 150 LPSHead 18 to 22 Mtrs(2W+2S) |
| 23 | Supplying all materials, labour, t&p and fixing of PLC Compatable ATV 930-VFD 45 KW approx./as required, HEAVY DUTY 16 AMP, WITH BREAKING UNIT VFD floor mounted Control Panel made out of 2MM C.R Powder coated sheet & alluminium BusBar interconnected with copper wire and lugsh having 50KA-125A MCCB including spreader link and extended ROM-1No, RYB indicator -1set, digital ammeter- 1 No, digital volt meter- 1No, 4A control. For Intake |
| 24 | Cables: Supply, Laying, testing and commissioning of following cable with in UG/trenches / trays along with fixing of cable clamps, identification tags and excluding excavation and backfilling also includes loading, unloading & transportation and providing tagging ( Make of wire -Finolex/Lauritz Knudsen /Anchor/ Havells /V Guard/Equivalent make with approval of the authority) |
| 25 | LT1.1KV 3.5x120 XLPE-Al Cables |
| 26 | LT 1.1KV 3.5x70 XLPE-Al Cables |
| 27 | LT 1.1KV 4x10 XLPE-Al Cables |
| 28 | LT 1.1KV 4x6 XLPE-AL Cables |
| 29 | Cable Tray: Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, with G.I. supporters including G.I. bolts & nuts, etc. as required for Substation Building, DG Shede, Approch bridge & Pump House. |
| 30 | 450 mm width X 50 mm depth X 2.0 mm thickness |
| 31 | 600 mm width X 50 mm depth X 2.0 mm thickness |
| 32 | Providing, installation, testing and commissioning of Diaphragm Type Pressure Gauges Dial size 150 mm glycerin filled shatterproof glass, Over range protection: 125% of maximum pressure, Material of sensor and other wetted parts: SS type 316, Housing material: Die cast aluminum with linear scale |
| 33 | Supplying all materials Labour & T & P for Fixing ductile iron Non Rising Spindle type Sluice Valve confirming to IS 14846 PN-1.6 with double flanged ends for water works purposes for the following nominal diameters as per specification complete including cost of Sluice valve .(VAG/ Talis/ AVK/IVC/ Kirloskar/Equivalent make with approval of the authority)250 mm dia PN 1.6 |
| 34 | Supply,fitting &fixing (VAG/ Talis/ AVK/IVC/ Kirloskar/Equivalent make with approval of the authority) Ductile Iron, Double flanged swing type non return valves IS: 5312, Part -I, Flanged ends. Providing and errecting of . 250 mm dia PN 1.6 |
| 35 | Electric Valve Actuator flanged end non rising spindle type sluice valve, PN 1.6 rating body-DI,Disc-SGI,Seat-EPDM,Shaft-SS410 with Qtork Gear box and (Make -AUMA/Rotork/Equivalent make with approval of the authority) 250 mm dia |
| 36 | Supply of electric powered electromagnetic full bore type IP 68 Fully welded Flanged type water flow meter of Pulse DC type of Flow tube SS304,coilhousing & electrodes SS316,SS RING TYPE grounding etc with IP 68 signal coverter remote mounting,input power supply 24V DC 4 - 20 mA,programable LCD display to show Actual flow rate,totalised flow, flow direction, flow velocity,conductivity with + or - 0.5% accuracy etc & provision to diagnostics empty pipe detection, coil tempreture, coil resitance etc & comptable to data communication modules with masibus & communicaton the data to remote SCADA station for live monitoning where ever required including providing data cable & power cable required as per site condition. The standard callbratation certificate & guaantee certificate for flow meter & electromagnetic signal coverter to be given for minumum one year from the date of installation. (Make- KROHNE MARSHALL/E&H/ABB/SIEMENS/Equivalent make with approval of authority) including cost material with all taxes transportation to Site/Storage with insurance.). All complete as per direction of Engineer in charge.700mm dia |
| 37 | Supplying all labour and T&P for providing and laying MS pipe and specials confirming to IS 3589/99 of quality grade FE 410/ GI Pipe (Medium ) confirming to specification of following nominal dia and including transportation of pipes and fitting to site etc all complete as per the direction of E.I.C. |
| 38 | 250 mm dia 6.3mm thick Delivery pipe |
| 39 | 500 mm dia 8 mm thick Header pipe |
| 40 | 250mm dia x 0.30m M.S Flanged shortpiece |
| 41 | 250 mm 450 Bends |
| 42 | 250 mm 900 Bends |
| 43 | 500 mm 450 Bends |
| 44 | 500 mm 900 Bends |
| 45 | 500 X 250 mm Reducer |
| 46 | Supplying all labour and T&P for following dia. dismantling joint etc all complete as per the direction of E.I.C. |
| 47 | 250 mm dismantling joint |
| 48 | 500 mm dismantling joint |
| 49 | Iron work wrought and put up in bolts less than 15 cm in length (labour only) |
| 50 | Providing and erecting DI Tamper proof Kinetic Air Valve (Make -VAG/ Talis/ AVK/IVC/ Kirloskar/Equivalent make with approval of the authority) 80 mm |
| 51 | Electrical Work for Intake well |
| 52 | 33 kV Substation Equipment |
| 53 | GI Pole -13 Meter Height (Approx. Weight - 31.1kg/mtr) |
| 54 | Cross arms channel size - 100 x 50 x 6 mm Length 3 mtr with nut and bolts |
| 55 | LA 10kA |
| 56 | Disc Insulator |
| 57 | DOG Conductor |
| 58 | LBS suitable for Trafo |
| 59 | DO Fuse - 63A |
| 60 | Stay with earthing |
| 61 | Misc item (fencing, barbed wire, danger board etc) |
| 62 | Design, engineering, procurement of materials and bought out components, manufacturing, assembly at shop, inspection, testing and painting at manufactures works, packing, supply, unloading/ transportation/ handling/ storage at site, assembly at site, installation including touch-up painting, hook-up, pre-commissioning, commissioning, inspection and testing of the complete of the following capacity (prime power) DG sets along with AMF panels. Acoustic enclosure, supply of all erection & commissioning spares, special tools and tackles (as required), instrumentation, all auxiliaries, Exhaust system & silencer, Fuel tank, Fuel piping etc all complete including RCC foundation,sheet Shed with column pipe,Chemical earthing 4 nos,Al power cable of required length,trial run with required amount of diesel as per directrion of EIC in complience with CPCB IV norms.400 KVA, 0.4 kV (415 V) (Make:- Mahindra Power/ Kirloskar/Ashok Leyland/Sterling/Jackson/ Cumin Powers/ Greaves Cotton/ Greaves/TMTL/Captiva/Equivalent make with approval of the authority) 400 KVA |
| 63 | POWER and LIGHTING DISTRIBUTION BOARDS 33kV HT Panel (1 Incomer + 2 Outgoing for 2 transformers + 1 Bus coupler)(630A VCB) |
| 64 | 33kV indoor, metal-clad, draw-out type HT switchgear panel structure |
| 65 | 630A VCB ( Incomer, 2 Outgoing, Bus Coupler) |
| 66 | Protection Relays (Numerical, Feeder & Transformer Protection) |
| 67 | CTs/PTs |
| 68 | Busbar (Copper/Aluminium with insulation) |
| 69 | Control & Relay Panel Wiring, Terminals, Aux. Components |
| 70 | Metering Instruments (Multifunction meters, energy meters) |
| 71 | Interlocking & Safety Features (Mechanical & Electrical) |
| 72 | Fabrication, Assembly & Internal Wiring |
| 73 | Testing & Factory Acceptance Test (FAT) |
| 74 | Installation, Testing & Commissioning |
| 75 | 0.4 kV Panels |
| 76 | PMCC Panel 415 V, 1250A ACB Incomer, 1 O/G for LED status indicator, 3 O/G for MCC panels, 1 O/G for APFC panel, 1 spare, TPN, 1250A Cu Busbar, 50Hz, floor mounted, with 3 phase and neutral system complete with front operated, outgoing MCCBs/MPCBs, cable alleys, necessary meters, internal control wiring, complete with all accessories and conforming to relevant standards, Design/ Manufacturing standards and as per technical specification. |
| 77 | MOTOR CONTROL CENTRE - 1 (MCC - 1) 415 V, 100A MCCB Incomer, 1 O/G for LED status indicator, 1 O/G (63 A MCCB) for Local Control Panel, 1 O/G (25 A MCB) for Lighting Distribution Board, 1 spare, TPN, 100A Cu Busbar, 50Hz, floor mounted, with 3 phase and neutral system complete with front operated, outgoing MCCBs/MPCBs, cable alleys, necessary meters, internal control wiring, complete with all accessories and conforming to relevant standards, Design/ Manufacturing standards and as per technical specification. |
| 78 | LIGHTING DISTRIBUTION BOARD (LDB - 2) 415 V, 32 A MCB Incomer, 1 O/G for LED status indicator, 2 O/G (MCBs) for indoor and outdoor lighting loads, 1 O/G for Exhaust fans, 1 for power socket, 3 spare, TPN, 32A Cu Busbar, 50Hz, wall mounted, with 3 phase and neutral system complete with front operated, outgoing MCCBs/MCBs, cable alleys, necessary meters, internal control wiring, complete with all accessories and conforming to relevant standards, Design/ Manufacturing standards and as per technical specification. |
| 79 | LIGHTING DISTRIBUTION BOARD (LDB - 3) 415 V, 32 A MCB Incomer, 1 O/G for LED status indicator, 2 O/G (MCBs) for indoor and outdoor lighting loads, 1 O/G for Exhaust fans, 1 for power socket, 3 spare, TPN, 32A Cu Busbar, 50Hz, wall mounted, with 3 phase and neutral system complete with front operated, outgoing MCCBs/MCBs, cable alleys, necessary meters, internal control wiring, complete with all accessories and conforming to relevant standards, Design/ Manufacturing standards and as per technical specification. |
| 80 | AUTOMATIC POWER FACTOR CORRECTION (APFC) PANEL 45 kVAR, 415V, 3 phase, 50Hz, Floor Mounted APFC panel with step control as per manufacturer, with enclosure as per tenchnical specification and conforming to relevant IS:13340/IEC specification and scope of work |
| 81 | WELDING RECEPTACLE (WR) Supply Erection, Testing and Commissioning of Industrial type, wall/structure mount, Ultra violet resistant, IP55, Switch receptacles having 63A, 5 pin socket / receptacles with plug top, 63A 4P MCB plastic body with loop in loop out facility. Each socket shall be provided with 4 way Junction box with suitable entries, metallic plugs, glands and all other accessories as required at site for Electrical room. |
| 82 | OUTDOOR LIGHTING Supply, installation, testing (SAT/FAT), commissioning, Loading/Unloading, Storage at warehouse (Hired by bidder), transporting from storage to site location of lighting fixtures complete with mounting bracket, flame proof/non flame proof, control gear box as per the type of fixture, lamps, 4 way junction boxes etc. including civil work with pipe inserts for cables and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Work to be completed in all respects. |
| 83 | Street lighting pole 7 mtr high GI -Hot dip galvanised octagonal pole, Dual arm complete with bracket, GI clamps, to mount Street Lighting Fixture |
| 84 | Lighting pole 3mtr high GI-Hot dip galvanised ( Bajaj make or equivalent) complete with bracket, GI clamps, to install platform handrail mounted streets lighting fixture. |
| 85 | Non flame proof Integral flood lighting fixture (for 45W LED) on building/ structure/pole |
| 86 | Street lighting Non flame proof luminaire (45W LED) |
| 87 | TUBULAR POLE 6 METER LONG WITH BRACKET |
| 88 | Other light points, power points, fans, ex. Fans etc with point wiring |
| 89 | LED Light Fixtures (20–24W, batten/industrial type) |
| 90 | LED Bulkhead / Utility Lights |
| 91 | Light Point Wiring (FRLS copper, DB to point) |
| 92 | Circuit Wiring (FRLS Copper 1.5 sqmm) |
| 93 | Ceiling fan with electronic regulator,Energy efficent, 60W, 1200 mm sweep,including regulator & point wiring |
| 94 | 120 W (CG make or equivalent) (including point wiring) |
| 95 | Switches & Modular Plates (including sockets) |
| 96 | Junction Boxes / AccessoriesB95:B96 |
| 97 | EARTHING AND LIGHTNING PROTECTION SYSTEM Supply, installation, testing, commissioning, Loading/Unloading, Storage at warehouse (Hired by bidder), transporting from storage to site location of the complete earthing and lightning protection system, earth electrodes/ pit, earth main ring, earthing of electrical equipments, instrument panels, field instruments, process equipments and pipes/ flanges including all associated civil work with all material and labour as per specification and drawings approved by the company. |
| 98 | Earth Pits- Copper plate Electrode with 6 mm thick chequered plate cover (Chemical Earthing) |
| 99 | Earth Pits- GI PIPE Electrode with 6 mm thick chequered plate cover |
| 100 | GI lightning rod 25 mm dia. 1800 mm long including supply of all hardware bare/insulated copper rope labour etc. complete as per approved drawings, specifications and directions of Engineer-In-Charge. |
| 101 | GI Strip (50 X 8) mm with Weld Connection (Stright / T connections) |
| 102 | GI Strip (25X3) mm with Weld Connection (Stright / T connections) |
| 103 | Copper Strip (25X3) mm with Weld Connection (Stright / T connections) |
| 104 | No. 8 SWG Solid GI Wire |
| 105 | Cabling System |
| 106 | 3C x 150 sq mm, 33kV HT Cable ( Make of wire -Finolex/Lauritz Knudsen /Anchor/ Havells /V Guard/Equivalent make with approval of the authority) |
| 107 | 3.5C X 150 SQ.MM, 1.1KV AL. XLPE AR. CABLE ( Make of wire -Finolex/Lauritz Knudsen /Anchor/ Havells /V Guard/Equivalent make with approval of the authority) |
| 108 | 3.5C X 25 SQ.MM, 1.1KV AL. XLPE AR. CABLE ( Make of wire -Finolex/Lauritz Knudsen /Anchor/ Havells /V Guard/Equivalent make with approval of the authority) |
| 109 | 4CX 2.5 SQ.MM, 1.1KV CU. XLPE AR. Wire ( Make of wire -Finolex/Lauritz Knudsen /Anchor/ Havells /V Guard/Equivalent make with approval of the authority) |
| 110 | 4CX 16 SQ.MM, 1.1KV CU. XLPE AR. Wire ( Make of wire -Finolex/Lauritz Knudsen /Anchor/ Havells /V Guard/Equivalent make with approval of the authority) |
| 111 | 33kV HT Termination Kit (OD) |
| 112 | 33kV HT Termination Kit (ID) |
| 113 | LT Termination Kit (OD) |
| 114 | LT Termination Kit (ID) |
| 115 | GLAND & CRIMPING TYPE COPPER AND ALUMINIUM LUGS FOR CABLE VARIOUS SIZE |
| 116 | Cable Tray with angles, nut-bolts, supports and associated accessories as per relevant standards, technical specifications and scope of works |
| 117 | LADDER CABLE TRAY 600 MM |
| 118 | PERFORATED CABLE TRAY 300 MM |
| 119 | PERFORATED CABLE TRAY 100 MM |
| 120 | STRUCTURAL STEEL |
| 121 | Main Supports (vertical posts, wall/floor mounted structures) |
| 122 | Cross Members / Cantilever Arms (tray supporting arms) |
| 123 | Hanging Supports (rods, suspenders for ceiling mounting) |
| 124 | Bracing & Stiffeners (for stability & load distribution |
| 125 | Base plates, Tray joint plates, Anchor Plates |
| 126 | Clamp, Cleats, Fasteners, Nut Bolt & Small fabrication |
| 127 | GI Pipe Supply and laying of following sizes of class 'B' G.I.Pipe in required length fixed on steel, concrete or similar sructure, laid in trenches, ready to be buried in concrete including cutting, threading, bending and similar works, supply of clamps, small iron structures, spacers and installation of seats, plugs, bushings etc. small civil works, including all labour and materials complete as per approved drawings and directions of Engineer-In-Charge. |
| 128 | 150 mm NB |
| 129 | 100 mm NB |
| 130 | 50 mm NB |
| 131 | Conduits and accessories |
| 132 | 25 mm PVC Conduit |
| 133 | 65 mm deep junction boxes |
| 134 | SCADA and Automation at Intake Fully Automated from WTP Control |
| 135 | SUPPLY, INSTALLATION, TESTING & COMMISSIONING FOR THE CONTROL AND INSTRUMENTATION WORK FOR INTAKE WITH 4 PUMPS |
| 136 | PLC Panel with HMI:PLC Compitable to VFD, Made out of 2MM C.R sheet, Duely Powder coated, Floor mounted, Front operated, complete with Rated Alluminium BusBar and interconnection with copper wire and lugs along with Annunciator, HMI Screen, Push Buttons etc. comprising 2 Digital Input Modules (16 DI), 2 Digital Output Modules (16 DO), 1 Analog Input Module (8 AI, 4–20 mA), and 1 Analog Output Module (8 AO, 4–20 mA)(Make-ABB/Siemens/Lauritz Knudsen/Equivalent make with approval of the authority) |
| 137 | Supply,Installation & Commissioning of SCADA software (Make-Schiender/Simens/Rockwell/Equivalent make with approval of authority) and cost for development of 24x7 distribution management system software, with Graphical processor visualisation Advanced alarm management, historical and Real time trending, Built-in-reporting, Stastical process control, Multithreaded citect VBA and Cicode programming language including installations of Desk top PC, Modem for receiving data etc all complete. |
| 138 | Internet Modem with static IP for data communication |
| 139 | Ultrasonic Level Indicators with following specification:Range= 0 to 8 mtr, Type =Ultrasonic / Radar, Power Supply- Loop Powered 24V DC, Out Put=4-20mA (Make-E & H/ABB/VEGA/WIKA/Equivalent make with approval of authority) |
| 140 | Pressure Transmitter :Designing, Supplying, Installing, commissioning & testing of pressure transmitter CE markd with following technical parameters at Raw Water Pump House and Interfacing with PLC panel including mounting arrangement along with snubber and needle valve, 1.0 sq.mm 2 core copper braided screen cable Wire, screw, grip & clamp for DI / MS pipe fitting.Output 4-20 mA / HART (With Display )(Make-E & H/ABB/VEGA/WIKA/Equivalent make with approval of authority) |
| 141 | RTU:-The RTU must be IP 20 rated of Industrial grade and must have following features:-1- Power Supply- 19.2 V DC... 30 V DC 2- Provision for surge voltage protection with Input protective diode, pulse load up to 1500 W and polarity parallel diode. reversal with 3- Ambient temperature Operation- 0 °C ... +55 °C. 4-32-bit processor with a minimum clock frequency of 64 MHz and with Program Memory - 256 kB, Data Memory 256 kB. Retentive Data Memory - 8 kB. 4 MB integrated, minimum 5 PIID Flash Memory loops 5-Online Integrated Ethernet port for Program Download/Upload and monitoring. 6- Integrated RS 485 port for connecting Modbus Slaves with data transmission speed of 9.6... 250 kbps 7- The RTU must be capable of working as a Modbus TCP as well as Modbus RTU Master or Slave configuration, simultaneously. It must be capable to open 8 Ethernet connections simultaneously with one Ethernet Port. 8- Immediate data sending to NIC server. 9- In case of Mobile network failure, the RTU must have the capacity to log 50 different parameters at 1 (Make-Schneider/Siemens/ABB/Mitsubishi/Equivalent make with approval of the authority) |
| 142 | Supply, Installation and commissioning of single phase 1KVA online UPS with pure sine wave & float cum boost charging with battery rack and maintenance free battery system including cables power plug, switch having application in 24V lot DC Battery (drytype) charging to output continuous 3 hrs power backup all Complete Works. |
| 143 | Chemical Earthing :chemical earthing with crystalline conducting material for Back Fill Compound & installation of Maintenance Free Earthing Electrode with ISI mark G.I. Pipe dia 50mm as Secondary electrode with wall thickness of 2.6mm and the primary earthing electrode will be 25mm x 6mm hot dipped galvanized strip filled with a highly conductive & non-corrosive compound in between the primary earthing & the secondary earthing. A solid G.I. Base plate of 300 x 300 mm seals the unit at the bottom. Ground filling compound will be provided in 25kg per bag - 2nos. Excavation of earth pit refilling, Precast RCC chamber with lid etc. all complete as per the site requirement. |
| 144 | OFC: Supply and Laying of 12core unarmoured Optical fibre cable (OFC :fiber glass with F-G 62.5/125micron, 2.6DB/KM F600) to various sites through HDPE pipe, prelaying testing of each cable drum for each fibre and taking the OTDR traces, submission of OTDR traces (in hard as well as soft copy) to Engineer-in-charge/ Site Engineer, blowing of OFC through previously laid HDPE, jointing / splicing of OFC, post installation testing of OFC for each fibre for each drum laid & taking OTDR traces, submission of OTDR traces (in hard as well as soft copy) to Engineer-in-charge/ SiteEngineer as per the scope, specifications and directions of Engineer-in-charge/ Site Engineer. |
| 145 | GRP Joint Box for OFC loop and termination along with OFC connection switch with Modem complete as per requirement. |
| 146 | supply, install, test and commission 1.5 TR capacity Split Type Inverter Air Conditioners of approved make complete with all standard accessories such as indoor & outdoor units, cordless remote, copper interconnecting tubing, drain pipe, power cable, outdoor stand/brackets, insulation, refrigerant gas charging, stabilizer (if required), earthing and all other accessories required for satisfactory operation of the system.The AC units shall be minimum 5-Star rated, inverter technology based, suitable for operation under Indian tropical climatic conditions and conforming to the latest relevant BIS/BEE standards. (Make:- Daikin/LG/Carrier/Hitachi/Equivalent make with approval of the authority) |
| 147 | Providing and Laying of Raw Water Rising Main Of 700mm Dia M.S. Pipe and Length- 350M |
| 148 | Earthwork Excavation-all kind of soil Earth work in All Type of soil within 50mtr initial lead and 1.5mtr initial lift including rough dressing and breaking of clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3mtr in depth as per direction of Engineer-in-charge. |
| 149 | 0-1.5 m |
| 150 | Earth Work Excavation-Hard soil Excavation of foundation in laterite rock or any hard rock(other than granite or disintegrated rock)removed by chiselling including dressing and leveling the bed not exceeding 1.5mtr depth and depositing the soil within 50mtr initial lead as per specification approved by the Deptt. |
| 151 | 0-1.5 m |
| 152 | 1.5 to 3.0 m |
| 153 | Supplying all labour, material, tools & plants for dismantling of bituminous courses of flexible pavements and disposal of dismantled materials upto a lead of 5 Km, stacking serviceable and unserviceable materials separately, all complete as per specification and direction of Engineer-in-charge. |
| 154 | Supplying all materials labour & T&P and providing (1:3:6) for C.C works with 40mm size hard granite metal including cost of all materials conveyance rovality etc. all complete. |
| 155 | Laying and Jointing of Pipe Material |
| 156 | Supplying all labour and T&P for providing and laying MS pipe and specials confirming to IS 3589/99 of quality grade FE 410/ GI Pipe (Medium ) confirming to specification of following nominal dia and including transportation of pipes and fitting to site etc all complete as per the direction of E.I.C.(excluding earth work in excavation, back filling, jointing and disposal of surplus earth). |
| 157 | 711 mm OD MS pipe 10 mm thick |
| 158 | 114.30 mm OD MS pipe 4.50mm thick |
| 159 | 700 mm dia MS Flange 25 mm thick |
| 160 | 100 mm dia MS Flange |
| 161 | 700 mm dia MS 900 bend |
| 162 | 700 mm dia MS 450 bend |
| 163 | Supplying all labour and T&P for cutting of following dia MS pipe of following thick in treanches by gas cutter set of pocket etc all complete |
| 164 | Supplying all labour and T&P for cutting of following dia MS pipe of following thick in treanches by gas cutter set of pocket etc all complete |
| 165 | Supplying all materials, labour and T&P for Providing flanged joints conforming to IS:3114 pipes and fittings of the following nominal diameter including testing of joints, cost of bolts nuts and rubber insertion, etc all complete as per specification and direction of Engineer In-Charge including supplying of all labour, material, tools & plants required to perform the work. |
| 166 | 700 mm |
| 167 | Providing and fixing DI Tamper proof Kinetic Air Valves of approved quality with bolts, nuts, rubber insertions etc. complete ( including the tail piece, tapers etc. complete). Heavy Duty 50mm dia suitable for working pressure up to 10kg/Cm2(Make -VAG/ Talis/ AVK/IVC/ Kirloskar/quivalent make with approval of the authority)Tamperproof Kinetic Air Valve (Without Isolating SLB, IS 14845) |
| 168 | 150 mm |
| 169 | Supplying all ,materials, labour, T & P for refilling the trenches with excavated materials within 50M initial lead and 1.5M initial lift etc. all complete. |
| 170 | Disposal of debris/surplus excavated earth to the site about 10 km away from the work siteetc., complete as per standard detailed technical specifications and approved design and drawings and any other incidental charges, hire charges of machinaries, loading and unloading charges with all lead and lift and as directed by the Engineer-in-charge. |
| 171 | RCC Valve Chamber Supplying all materials,labour and T&P for Construction of RCC valve chamber in (1:1.5:3 ) mix with foundation concrete, R.C.C. cover slab with SFRC SD-20 cover , inside plaster 12mm. thick with cement mortar (1:3) finished with neat cement punning, 12mm. thick out side plaster (1:3) including earth work excavation in foundation and refilling the cavity with excavated earth etc all complete as per direction of Engineer in charge |
| 172 | Size ( 1.20 X1.20 X1.20)M |
| 173 | Providing & Constructing RCC Thrust blocks 700 mm Dia (4 Nos.) |
| 174 | Earth work in all Kind of soil within 50m, initial lead and 1.5m, initial lift including rought dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-charge |
| 175 | Supplying all materials labour & T&P and providing (1:3:6) for C.C works with 40mm size hard granite metal including cost of all materials conveyance rovality etc. all complete. |
| 176 | R.C.C work in ground floor of M-25 grade with 20mm & down grade crusher broken hard Granite chips including hoisting & laying with cost of all labour, materials with all taxes, lead ,T & P etc all complete .including cost of binding wire, centering & strutting, including labour charges, backfilling, carting of extra earth etc complete for finished item of work and as directed by the Engineer-in-charge |
| 177 | Rigid smooth centring and shutteringR.C.C. Foundation, Plinth Band, Footings, Column Base, Mass Concrete & Precast Slabs |
| 178 | Supply and fabrication mild steel or tor steel bars of all size for reinforcement of RCC works including conveying steel to workspot with all lead including cleaning straighteing, bending, fabricating, placing in position, being as per designs including cost of binding wire hoisting all lift (Steel shall be procured from SAIL/TATA/Vizag STEEL TMT-EQR 500/IS 1786 Fe 500 D and test certificate shall be furnished)with all lead and lift etc., complete |
| 179 | Water Treatment Plant (20 MLD) |
| 180 | Design, Drawing ,Construction , Commissioning &Testing of conventional WTP with Cascade aerator, Raw water channel, Chemical house, Chemical store, Dosing arrangements, /Chlorinator, Flash Mixer, Rapidmix, HBCF, RGF /Clariflocculator, bye pass channel, filter house & back wash arrangement with pump, CWR, Clear water pump house, Lab, Administrative Block, internal road & lighting, internal drainage arrangement, internal electrification /Arboriculture etc, but excluding clear water pumps , External Electrification, Automation & instrumentation & sludge Treatment. |
| 181 | Filling in foundation/plinth/low-lying areas (0.5 to 4 Mtr. depth as per the contour sheet )at WTP Site with sand, well-watered and compacted in layers not exceeding 300 mm thickness, including all labour, machinery, T&P, leads and lifts, initial & final level to be recorded in the level book and to be cerified by the field Engineer etc. complete as per the direction of the Engineer-in-Charge. |
| 182 | Design, Drawing ,Construction , Commissioning &Testing of Zero westage plant and SCADA Autometion of plant |
| 183 | Wash water recirculation Sump(Capacity 590Cum) |
| 184 | Supplying all labour, T&P and earth work in excavation in all kinds of soil in pipe trenchs etc including dressing and levelling the bed and depositing the soil within 50M initial lead and 1.5M initial lift, as per the direction of the Engineer-in-charge. |
| 185 | 0 to 1.5 mt depth |
| 186 | 1.50 to 4.5 mt depth |
| 187 | Providing cement concrete (1:3:6) with 40mm size HG metal including cost of all materials, labour T & P etc. all complete as per specification & direction of Engineer-in-charge. |
| 188 | Rigid smooth centring and shuttering for R.C.C. works and dismantling then after casting including cost of materials,labour & T & P etc. all complete. |
| 189 | R.C.C. Foundation, Plinth Band, Footings, Bases of Columns, Mass Concrete & Precast Slabs etc. in Ground Floor. |
| 190 | R.C.C. Walls |
| 191 | R.C.C. roof slab |
| 192 | Cement concrete (M-25) with 12mm.size crusher broken hard Granite chips for R.C.C.work including hoisting & laying with cost of all labour, materials with all taxes, lead ,T & P etc all complete . |
| 193 | M.S. Reinforcement for R.C.C. works including cutting,bending, binding and tying grills and placing in position including cost of M.S.Rods,binding wire 18 to 20 gauge. |
| 194 | 6mm thick C.P. (1:4) to RCC surface finished smooth including closed deep chipping and slurry treatment including all materials labour & T & P etc. complete as per direction of Engineer in charge. |
| 195 | Filling foundation and plinth with excavated materials including watering and ramming as per specification & direction of Engineer-in-charge. |
| 196 | Supplying fitting & fixing of S.F.R. poly popylene foot step iron |
| 197 | Cost towards HD 20 factory made precast RCC cover slab of outer size 765 mm x 765mm of 90mm thick with factory made precast RCC frame of outer size 1065mm x 1065mm of 150mm thick with groove cutting suitable to hold 90mm thick cover slab. |
| 198 | Supplying all labour and T&P for railing 50mm MS pipe work around the top of chamber with arc welding etc all complete |
| 199 | Flame cutting and facing of MS plate or pipes upto 8mm thick including supply of all labor, material, tools & plants for all complete as per specification and direction of Engineer-in-Charge. |
| 200 | Supplying all labour and T&P for Welding with two welding beads/pass, conforming to IS:816-1998 (Fillet weld) to MS pipes and fittings at site. |
| 201 | Filter Pess Or centrifuse Building |
| 202 | Design, Drawing and Construction of RCC frame structure with brick work wall double stored building for filter press or Centrefuse Building complete as per the direction of Engineer-in-charge |
| 203 | Supply of all material, labour, T&P for Electrification Work and chair table, almera,etc of SCADA control room, complete as per the direction of Engineer-in-charge.Procesees /surface wiring to light point /fan point e fan point /call bell point with 1.50 sqmm FR PVC insulated single core multi starand copper consuctor of ISI marked with 20mm dia non -m MS box with 1.5 sqmm FR PVC insulated single core multistrand copper consuctor as earth wire including al laceessories and conenectin ( Make of wire -Finolex/Lauritz Knudsen /Anchor/ Havells /V Guard/Equivalent make with approval of the authority) Light Points |
| 204 | Group -A |
| 205 | Group -B |
| 206 | 5 A Plug point |
| 207 | Fan point ( Group - A) |
| 208 | Supplying all materials labour & T & P for fitting & fixing of following electrical installations including testing & commissioning etc. complete as per direction of Engineer in Charge. |
| 209 | Step up modular regulator for Fan |
| 210 | 15watt LED Bulb. |
| 211 | 1200mm Ceiling Fan (Havells/ Bajaj/Usha/ Equivalent make with approval of the authority) |
| 212 | Electric 200mm Exhaust Fan (Havells/ Bajaj/Usha/ Equivalent make with approval of the authority) |
| 213 | Electric 150mm Exhaust Fan (Havells/ Bajaj/Usha/ Equivalent make with approval of the authority) |
| 214 | Titanio Pro LED Tube Light -18W (Double side connection) |
| 215 | 32A Double Pole MCB. |
| 216 | 5 Amp switch |
| 217 | 5 Amp socket |
| 218 | Ceiling Rose - |
| 219 | Angle Holder |
| 220 | Supplying, fitting and fixing of 15 Amp plug point with line connection and testing charges.. |
| 221 | Supply, Installation, Testing Wiring & Commissioning of Lighting Distribution Panel Made out of 2MM C.R sheet, Duely Powder coated, Floor mounted, Front operated, complete with Rated Alluminium BusBar and interconnection with copper wire and lugs. Having 63A 4P MCB-1 Nos,32A FP MCB-2 Nos, 32A DP MCB-1 Nos, 16A DP MCB- 3Nos, 10A DP MCB-1Nos, All switchgear and controlgear make- Siemens,schneider,ABB,Lauritz Knudsen,LEGRAND/Equivalent make with approval of the authority. All completed as per electrical specification and as per direction of EIC. |
| 222 | Cable junction boxes IP66/69 weather proof for outdoor installation of size 104mm x 104mm x 70 mm (with knockouts for cable entry - Black colour) |
| 223 | Connector suitable for 4sqmm For yard lighting |
| 224 | 2.50 Sqmm 4 core copper armoured Cable including laying |
| 225 | Supply of each Filter Press WEFH-4848 HydraulicMotorized Type Tightening arrangement & FiltrateCollection PIPE. With complete errection as per Ingineering-In-Charge. |
| 226 | Supply of Screw Pump (20m3/hr) With Motor (7.5 HP & 144 RPM) With complete errection as per Ingineering-In-Charge |
| 227 | Supply 702cc diesel engine, 16HP, 750kg payload, 4-speed manual, 30L fuel tank, 1550kg GVW, leaf spring suspension, BS6 compliant mini truck for disposal of cake |
| 228 | Sludge Handling Pumps & Equipment |
| 229 | Sludge Thickner |
| 230 | Supplying all labour, T&P and earth work in excavation in all kinds of soil in pipe trenchs etc including dressing and levelling the bed and depositing the soil within 50M initial lead and 1.5M initial lift, as per the direction of the Engineer-in-charge. |
| 231 | 0 to 1.5 mt depth |
| 232 | 1.50 to 4.5 mt depth |
| 233 | Filling foundation and plinth with excavated materials including watering and ramming as per specification & direction of Engineer-in-charge. |
| 234 | Providing cement concrete (1:3:6) with 40mm size HG metal including cost of all materials, labour T & P etc. all complete as per specification & direction of Engineer-in-charge. |
| 235 | Rigid smooth centring and shuttering for R.C.C. works and dismantling then after casting including cost of materials,labour & T & P etc. all complete. |
| 236 | R.C.C. Foundation, Plinth Band, Footings, Bases of Columns, Mass Concrete & Precast Slabs etc. in Ground Floor. |
| 237 | R.C.C. Walls |
| 238 | R.C.C. roof slab |
| 239 | Cement concrete (M-25) with 12mm.size crusher broken hard Granite chips for R.C.C.work including hoisting & laying with cost of all labour, materials with all taxes, lead ,T & P etc all complete . |
| 240 | M.S. Reinforcement for R.C.C. works including cutting,bending, binding and tying grills and placing in position including cost of M.S.Rods,binding wire 18 to 20 gauge. |
| 241 | 12mm thick cement plaster (1:4) to inside surface including all materials labour & T & P etc. complete as per direction of Engineer in charge. |
| 242 | Supplying all labour and material of drive unit, Rake Mechanise, Scraper Mechanism, Scum Skimmer, Torque Limiter ect work for Sludge Thickener as per specification and direction of Enginer - in - charge. |
| 243 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32 mm x 32 mm x 2 mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour, T&P etc. required for the complete in all respect.C/C and stainless square pipe bracing of size case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour, T&P etc. required for the complete in all respect. |
| 244 | Sludge Chamber |
| 245 | Supplying all labour, T&P and earth work in excavation in all kinds of soil in pipe trenchs etc including dressing and levelling the bed and depositing the soil within 50M initial lead and 1.5M initial lift, as per the direction of the Engineer-in-charge. |
| 246 | 0 to 1.5 mt depth |
| 247 | 1.50 to 4.5 mt depth |
| 248 | Filling F&P with sand welwatered rammed etc complete |
| 249 | Providing cement concrete (1:3:6) with 40mm size HG metal including cost of all materials, labour T & P etc. all complete as per specification & direction of Engineer-in-charge. |
| 250 | Rigid smooth centring and shuttering for R.C.C. works and dismantling then after casting including cost of materials,labour & T & P etc. all complete. |
| 251 | R.C.C. Foundation, Plinth Band, Footings, Bases of Columns, Mass Concrete & Precast Slabs etc. in Ground Floor. |
| 252 | R.C.C. Walls |
| 253 | R.C.C. roof slab |
| 254 | Cement concrete (M-25) with 12mm.size crusher broken hard Granite chips for R.C.C.work including hoisting & laying with cost of all labour, materials with all taxes, lead ,T & P etc all complete . |
| 255 | M.S. Reinforcement for R.C.C. works including cutting,bending, binding and tying grills and placing in position including cost of M.S.Rods,binding wire 18 to 20 gauge. |
| 256 | 12mm thick cement plaster (1:4) to inside surface including all materials labour & T & P etc. complete as per direction of Engineer in charge. |
| 257 | Filling foundation and plinth with excavated materials including watering and ramming as per specification & direction of Engineer-in-charge. |
| 258 | Supplying fitting & fixing of S.F.R. poly popylene foot step iron |
| 259 | Supplying all materials, labour and T&P for Transportation of excavated material & disposing upto 5KM from work site including loading, unloading & stacking, supplying of all labours, tools & plants etc. all complete as per specification and direction of Engineer-in-charge. |
| 260 | Providing cement concrete (1:2:4) with 12mm size HG chips including cost of all materials, labour T & P etc. all complete as per specification & direction of Engineer-in-charge. |
| 261 | Cost towards HD 20 factory made precast RCC cover slab of outer size 765 mm x 765mm of 90mm thick with factory made precast RCC frame of outer size 1065mm x 1065mm of 150mm thick with groove cutting suitable to hold 90mm thick cover slab. |
| 262 | Cost for Construction of a RCC MHC of size 1.20 mtr dia x 1.67 mtr depth including cost of SFRC Man Hole Cover with frame base slab, Chanel & Benching, but excluding earth work excavation , refilling & removal of surplus earth etc. |
| 263 | SITC FOR THE CONTROL AND INSTRUMENTATION WORK FOR 20MLD WTP+CWPH |
| 264 | Open channel Electronic Flowmeter with FI and FT at Parshall Flume |
| 265 | Supply and installation testing with technical specification PH Sensor (DPC1R1A) Accuracy: Less than 0.1 pH under reference conditions Body Material: PPS, Electrode Material: General Purpose Glass pH Electrode, Flow: 0 2 m/s (0 - 6.6ft ./s) non-abrasive Operating temperature range: 0 - 105 deg * C Pressure Range: 0-6.9 bar at 100 deg * C (0-100 psig at 212 deg * F ) Range: Combination pH Sensors 0-14 PH, Sensor Cable: Integral coaxial cable (plus two conductors for temperature compensator option); 4.5 m (15 ft.) long Sensor Thread: 0.75 ^ prime prime Temperature Compensation: Pt 1000 ohm RTD Includes: sensor with 15 ft cable, digital gateway, 3 ft digital extension cable and manual(ABB/E&H/Forbes Marshall/Equivalent make with approval of the authority) at Aerator Channel & CWPH |
| 266 | Supply & installation of Turbidity at filter house for online monitoring of turbidity in clear water with following technical specification i.e sensor type Optical nephelometer turbidity and suspended solids sensor, sensor rating IP68, Range-0 to 4000 NTU, Accuracy 2% measured valyue, Display resolution -0.001 NTU, operating pressure up to 10 bar (145psi), power 100 mA@24V DC (ABB/E&H/Forbes Marshall/Equivalent make with approval of the authority)at Aerator Channel & at CWPH |
| 267 | Supply, Installation, testing & commissioning of WATER Quality Moniterfor Residual Chlorine in DistributinNetwork, the Input Power Supply should be internal battery (2 of LSH 20 3.6V High Discharge Lithium Battery withCommunication and Data Logging through GPRS Modem, Website, RS232 link to PC, RS232 link to Bluetooth dongle to mobile Device, Storageof upto 55000 data points in the device and having Electrical Connections 1X 9Way Fischer Socket Yellow (102) Style for RS 232/Bluetooth dongle, 1X 5Way Fischer Socket (103) Style for Chlorine Sensor, 1X 9Way Fischer Socket red (102) Style for External Device, 1X 7Way Fischer Socket Grey (102) Style for External Device having Environmental protection 1P68 to 1m the analyser is designed to fit within Standard Hydrant Chamber with Minimum of 300mm between the Hydrant outlet to the underside of the Chamber lid-150mm(w) x 164mm(h) Weight including laying of connecting uPVC pipe Sch-80 & power supply arrangements etc. complete as per requirement & direction of Engineer Charge. (ABB/E&H/Forbes Marshall/Equivalent make with approval of the authority) with wireless communication to PLC for monitoring and operation of the Clariflocculator, including flocculation control and its operational parameters at clear water section |
| 268 | Pressure Indicator at common header of Air blowers-1 No., Wash water tank filling pumps-2 Nos.,common header of Wash water tank filling pumps-3 Nos., Alum dosing pumps- 2 Nos.& PE dosing pumps-2 Nos. |
| 269 | Mechanical Flowmeter with FI and FT (200NB) at common header of Wash water tank filling pumps |
| 270 | Level switch at wash water tank & Conductive Type Level switch at Alum/PAC Tank & at PE Tank |
| 271 | Level Indicator at PE Tank & Alum/PAC Tank |
| 272 | Ultrasonic Level Transmitter 0-5 mtr (LOH) & Ultrasonic Level Transmitter 0-5 mtr (ROF) at Filter bed |
| 273 | Pressure Transmitter 0 to 10 kg/cm3 at Air blowers |
| 274 | PLC SCADA AUTOMATION |
| 275 | Main WTP PLC System, 12\\" HMIDI: 224, DO: 128, AI:24, AO:8 |
| 276 | PLC System, 12\\" HMI for Filter Bed ConsoleDI: 64, DO: 32, AI:16, AO:8 |
| 277 | Electric Valve Actuator flanged end non rising spindle type sluice valve, MOV with inch type PN 1.6 rating body-CI,Disc-SGI,Seat-EPDM,Shaft-SS410 with Gear box and Actuator (Make -AUMA/Rotork/Equivalent make with approval of the authority) 200 mm dia |
| 278 | Supply, Installation & Commissioning of SCADA software (Make-Schiender/Simens/Rockwell/Equivalent make with approval of authority) and cost for development of 24x7 distribution management system software, with Graphical processor visualisation Advanced alarm management, historical and Real time trending, Built-in-reporting, Stastical process control, Multithreaded citect VBA and Cicode programming language including installations of Desk top PC, Modem for receiving data etc all complete. |
| 279 | IT Hardware (Workstations x 4, A3 Printer x 1,) |
| 280 | 24 port Managed Ethernet Switch (Industrial Grade) |
| 281 | Supplying,Installation & testing of network gateway, often including firewall, VPN, and traffic management features of (Firewall throughput 7000Mbps, Firewall IMIX - 2900Mbps, IPS throughput - 1355Mbps, Threat protection throughput - 330Mbps, Concurrent Connection - 1600000, New connection/sec - 44400, Xstream SSL/TLS Inspection - 420Mbps, Xstream SSL/TLS Concurrent connections - 81924G and comlpeted as per specification and Ingineering_In-Chargeas. |
| 282 | Static Internet Connection (Subscription for 5 years) |
| 283 | Supply, Installation and commissioning of single phase 1KVA online UPS with pure sine wave & float cum boost charging with battery rack and maintenance free battery system including cables power plug, switch having application in 24V lot DC Battery (drytype) charging to output continuous 3 hrs power backup all Complete Works. |
| 284 | Type 2-1 P+N 15KVA Surge protection device |
| 285 | MCC Room |
| 286 | Windows based PC with latest configuration & OS complete with necessory office & antivirus softwares.PC configuration shall not be less than Intel i5 10th Gen CPU, 16 GB Ram, 128 GB SDD, 500 GB HDD, DVD RW, Rs232 &Rs485 port, 2 RJ45 ports, Keyboard, Optical Mouse, 32 inch color TFT Monitor, Latest Windows Pro OS, Microsoft Office & Antivirus & Internet Sequrity software for 3 years license. |
| 287 | Supply, Installation and commissioning of LT surge arrester having 5KA capacity with spike and all accessories including cost of all materials, labour, T & P etc all complete. |
| 288 | 1 TB SSD (Solid State Device) for RAM |
| 289 | Supply, Installation & Commissioning of43\\" LED TV for SCADA PC Extension for operator station |
| 290 | Laserjet black & white Printer |
| 291 | Gigabit SFP to RJ45 Fibre multi Media Converter I fibte to Ethernet ConverterI 10/100/1000 Mbps RJ45 Port to 1000Base-LX Dual-Mode Fibre |
| 292 | 24 Port fibreoptic panel or light interface unit (LIU) draw out Type |
| 293 | OFC Splicing with pigtails |
| 294 | Fibre Pigtail/patch cord 1 mtr |
| 295 | Optical fibre 8-port managed L3 gigabit fibre switch and media converter for non-blocking throughput switching, high performance and low latency, Gigabit Ethernet SFP and RJ45 ports. |
| 296 | Fibre SFP Multi mode transceiver 100 base LC type module |
| 297 | CAT-6 Cable |
| 298 | Laying of CAT-6 Cable either in HDPE duct underground or GI wire support |
| 299 | Internet Modem with static IP for data communication |
| 300 | Design, Drawing ,Construction , Commissioning &Testing of CCTV IR water proof camera suitable for upto 100ft. With IR Dome camera, control key board, DVR, Hard Disk, cables, UPT transreceivers etc. complete. Make-Hikvision/CP Plus/Evision/Honeywell/Equivalent make with approval of the authorityu) with 8 nos. camera |
| 301 | Instrument Cable and Cable Tray |
| 302 | Power Cable 3C x 1.5 sqmm armoured ( Make of wire -Finolex/Lauritz Knudsen /Anchor/ Havells /V Guard/Equivalent make with approval of the authority) |
| 303 | Control Cable 1 pair x 1.5 sqmm armoured ( Make of wire -Finolex/Lauritz Knudsen /Anchor/ Havells /V Guard/Equivalent make with approval of the authority) |
| 304 | Control Cable 6 pair x 1.5 sqmm armoured ( Make of wire -Finolex/Lauritz Knudsen /Anchor/ Havells /V Guard/Equivalent make with approval of the authority) |
| 305 | Control Cable 12C x 1.5 sqmm armoured ( Make of wire -Finolex/Lauritz Knudsen /Anchor/ Havells /V Guard/Equivalent make with approval of the authority) |
| 306 | Control Cable 24C x 1.5 sqmm armoured ( Make of wire -Finolex/Lauritz Knudsen /Anchor/ Havells /V Guard/Equivalent make with approval of the authority) |
| 307 | Cable Tray 50 mm |
| 308 | Cable Tray 100 mm |
| 309 | Cable Tray 200 mm |
| 310 | Cable Tray 300 mm |
| 311 | Instrument Earthing 40Mm Dia. MS Rod Electrode 3 Mtr Long For IEP |
| 312 | Earth Pit RCC Cover With Lifting Handle For Pit |
| 313 | Instrument Earthing Strip 25X3 Mm GI Flat Earth Conductor |
| 314 | HDPE Pipe: Supply and laying of 40 mm dia HDPE in cable trench or buried as per specification and directions of Site Engineer / Engineer - in -charge. |
| 315 | Clear water Pumping station |
| 316 | Supply of Level Transmitter to be installed at wash water tank & CWR (Clear Water Reservoir) with following specification: Range= 0 to 8 mtr, Type Ultrasonic / Radar, Power Supply- Loop Powered 24V DC, Out Put=4-20mA (Make-E & H/ABB/VEGA/WIKA/Equivalent make with approval of authority) |
| 317 | Pressure Transmitter Designing, Supplying, Installing, commissioning & testing of pressure transmitter CE markd with following technical parameters at Raw Water Pump House and Interfacing with PLC panel including mounting arrangement along with snubber and needle valve, 1.0 sq.mm 2 core copper braided screen cable Wire, screw, grip & clamp for DI/MS pipe fitting. (Make-E & H/ABB/VEGA/WIKA/Equivalent make with approval of authority) Output 4-20 mA / HARTPower supply - 24V DC ext.Display - 4\\" LEDAccuracy +/- 0.1% of full scaleor betterEnclosure- IP 68 |
| 318 | Provision of Glycerine filled Pressure Gauge with fittings & isolation ball valve with socket including cost of all materials, Transportation to site etc all complete all labours, T&P etc. all complete as per the direction of Engineer-in-charge. |
| 319 | Design Engineering Procurement Supply Installation and commissioning of complete with all associated accessories & anti syphon ejectors,instruments,pipes valves,fittings including chlorine leak neutralization system with caustic tank tower,packing,pumps,blowers,detectors,sensors.Chlorine safety scrubbing system including other safety equipments with all automation system including PLC, required software so that all the instruments of scrubing system will run automatically during any leakage etc all complete as per the specification. |
| 320 | Instrument Cable and Cable Tray |
| 321 | Pumping Station ( CWPH ) |
| 322 | Power Cable 3C x 1.5 sqmm armoured ( Make of wire -Finolex/Lauritz Knudsen /Anchor/ Havells /V Guard/Equivalent make with approval of the authority) |
| 323 | Control Cable 1 pair x 1.5 sqmm armoured ( Make of wire -Finolex/Lauritz Knudsen /Anchor/ Havells /V Guard/Equivalent make with approval of the authority) |
| 324 | Control Cable 12C x 1.5 sqmm armoured ( Make of wire -Finolex/Lauritz Knudsen /Anchor/ Havells /V Guard/Equivalent make with approval of the authority) |
| 325 | 1.5 Sqmm 4C Cu AR Shielded cable ( Make of wire -Finolex/Lauritz Knudsen /Anchor/ Havells /V Guard/Equivalent make with approval of the authority) |
| 326 | 1.5 Sqmm 2C Cu AR Shielded cable ( Make of wire -Finolex/Lauritz Knudsen /Anchor/ Havells /V Guard/Equivalent make with approval of the authority) |
| 327 | Instrument cable - 2 Pair, 1.5 Sqmm Cable ( Make of wire -Finolex/Lauritz Knudsen /Anchor/ Havells /V Guard/Equivalent make with approval of the authority) |
| 328 | Cable Tray 50 mm |
| 329 | Cable Tray 100 mm |
| 330 | Cable Tray 300 mm |
| 331 | Earthing: Providing Electrical system system's earthing as per latest IS 3043, and the work shall include the following: Earthing electrodes comprising of GI pipe 40mm dia 2.9 mm thick 2.5 mtrs long with mesh covered funnel. Digging 300mm dia earthing pits to suitable depth for buring the main electrodes in the pit. The pit shall be filled with alternate layers of salt and charcoal 150mm thick around the pipe to the entire depth. An inspection chamber of 300x300x300mm size shall be constructed with CC 1:3:6 prop. The chamber shall be provided with CI/MS cover hinged to the frame. The Electrical Metering & switching , encloser electrical equipment shall be connected to the earth pit through 4 Sqmm Cu (green) for equipment/PLC earthiing |
| 332 | Instrument Earthing Strip 25X3 Mm GI Flat Earth Conductor |
| 333 | Installation and supplying Pumping Machinery at WTP Clear Water Pump House Mechnical Work. |
| 334 | Clear Water Pumps -Supplying centrifugal Pump suitable for Clear Water application with standard MOC and given duty points as below with motor (as per required capacity drive the pump) in Pumset Including Accessories 15m each cable Pumpset Price with cable including LT PMU, Autocoupling with Integral Bend (With Autocoupling PIN)+ Foundation bolt; (Each) CI Body with SS ImpellerRPM1480 |
| 335 | Flow -135 to 145 LPS H- 60 to 65 Mtr(2W+2S) |
| 336 | Supplying all materials, labour, t&p and fixing of PLC Compatable ATV 930-VFD 110 KW, HEAVY DUTY 16 AMP, WITH BREAKING UNIT VFD floor mounted Control Panel made out of 2MM C.R Powder coated sheet & alluminium BusBar interconnected with copper wire and lugsh having 50KA-125A MCCB including spreader link and extended ROM-1No, RYB indicator -1set, digital ammeter- 1 No, digital volt meter- 1No, 4A control for WTP |
| 337 | LT Switchgear Panel with APFCR : Design, fabrication, supply, erection, installation, testing and commissioning of floor mounted LT Panel primer coated with powder coated paint & provided with required gasket for dust / vermin proof with degree of protection IP42 suitable for 415V 3 phase, 50 Hz,4 wire system fabricated out of CRCA sheet up to 2 mm thick (1.6 mm for doors) duly compartmentalized for incomer, bus section, outgoings, cable alleys & CT, PT Ampere Meter, Volt Meter, selector switches, Frequency Meter, phase indicating lamps, MFM complete including cost of busbar supports, detachable cable gland plates, 2 earthing terminals, internal wiring & fixing of MCBs, MCCBs , etc. as required and mentined in the attached SLD inluding cost of bus bar strips, Ampere Meter, Volt Meter, Selector switch as per approved design & specification.( MBR) |
| 338 | Supply of 33kV 1250A 31.5kA (AL) Single Indoor VCB PANEL with CT ,PT ,Meter and Relays as per specification and direction of Enginer - in - charge |
| 339 | Cables: Supply, Laying, testing and commissioning of following cable with in UG/trenches / trays along with fixing of cable clamps, identification tags and excluding excavation and backfilling also includes loading, unloading & transportation and providing tagging ( Make of wire -Finolex/Lauritz Knudsen /Anchor/ Havells /V Guard/Equivalent make with approval of the authority) |
| 340 | LT1.1 KV 3.5x120 XLPE-Al Cables |
| 341 | LT 1.1KV 3.5x70 XLPE-Al Cables |
| 342 | LT 1.1KV 4x10 XLPE-Al Cables |
| 343 | LT 1.1KV 4x6 XLPE-AL Cables |
| 344 | Cable Tray: Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, with G.I. supporters including G.I. bolts & nuts, etc. as required for Substation Building, DG Shede, Approch bridge & Pump House. |
| 345 | 450 mm width X 50 mm depth X 2.0 mm thickness |
| 346 | 600 mm width X 50 mm depth X 2.0 mm thickness |
| 347 | Providing, errecting Glyscerine filled Pressure gauge of required range complete with syphon tube.150 mm dia |
| 348 | Supplying all materials Labour & T & P for Fixing ductile iron Non Rising Spindle type Sluice Valve confirming to IS 14846 PN-1.6 with double flanged ends for water works purposes for the following nominal diameters as per specification complete including cost of Sluice valve . (Make-VAG/ Talis/ AVK/IVC/ Kirloskar/Equivalent make with approval of the authority) |
| 349 | 300 mm DF Sluice valves PN 1.6 |
| 350 | 400 mm DF Sluice valves PN 1.6 |
| 351 | 450 mm DF Sluice valves PN 1.6 |
| 352 | Supply, fitting and fixing of Ductile Iron double-flanged swing type Non-Return Valve with damper kit conforming to IS: 5312 (Part-I) with flanged ends, including providing and erecting complete. Make- (VAG/ Talis/ AVK/IVC/ Kirloskar/Equivalent make with approval of the authority) |
| 353 | 300 mm CI DF NR Valves PN 1.6 rating |
| 354 | Electric Valve Actuator flanged end non rising spindle type sluice valve, MOV with inch type PN 1.6 rating body-CI,Disc-SGI,Seat-EPDM,Shaft-SS410 with Gear box and Actuator (Make -AUMA/Rotork/Equivalent make with approval of the authority) |
| 355 | 300 mm dia |
| 356 | Supplying all labour and T&P for providing and laying MS pipe and specials confirming to IS 3589/99 of quality grade FE 410/ GI Pipe (Medium ) confirming to specification of following nominal dia and including transportation of pipes and fitting to site etc all complete as per the direction of E.I.C. |
| 357 | 300 mm 7.1 mm thick Suction Pipe |
| 358 | 300 mm 7.1 mm thick Delivery Pipe |
| 359 | 800mm 8 mm thick Common Header Pipe |
| 360 | 400 mm 8 mm thick Outlet Pipe 01 |
| 361 | 450 mm 8 mm thick Outlet Pipe 01 |
| 362 | 200mm dia x 0.30m M.S Flanged shortpiece |
| 363 | 400 mm dia 900 Bends |
| 364 | 300 mm dia 900 Bends |
| 365 | 300mm dia dismantaling joint |
| 366 | 400mm dia dismantaling joint |
| 367 | 450mm dia dismantaling joint |
| 368 | Providing and erecting DI Tamper proof Kinetic Air Valve (Make -VAG/ Talis/ AVK/IVC/ Kirloskar/Equivalent make with approval of the authority) 80 mm |
| 369 | Supplying, erecting and commissioning single girder Electrically Operated Rectangular Over head Travelling Crane with 6 m lift complete with wire rope hoist, class II duty, all three motions electrically operated by suitable rating motor IP 54, control panel and down pendant control block including supplying all materials,labour and T&P for fitting and fixing of ISMB 300mmx 200mm x 6mm thick on two side walls of the pump house so as to accommodate the gantry rail including fitting, fixing , hoisting and placing in position all complete as per the direction of Engineer in charge..5 Tonne CapacityAbove 8 m upto 10 m span |
| 370 | Design, engineering, procurement of materials and bought out components, manufacturing, assembly at shop, inspection, testing and painting at manufactures works, packing, supply, unloading/ transportation/ handling/ storage at site, assembly at site, installation including touch-up painting, hook-up, pre-commissioning, commissioning, inspection and testing of the complete of the following capacity (prime power) DG sets along with AMF panels. Acoustic enclosure, supply of all erection & commissioning spares, special tools and tackles (as required), instrumentation, all auxiliaries, Exhaust system & silencer, Fuel tank, Fuel piping etc all complete including RCC foundation,sheet Shed with column pipe,Chemical earthing 4 nos,Al power cable of required length,trial run with required amount of diesel as per directrion of EIC in complience with CPCB IV norms.400 KVA, 0.4 kV (415 V) (Make:- Mahindra Power/ Kirloskar/Ashok Leyland/Sterling/Jackson/ Cumin Powers/ Greaves Cotton/ Greaves/TMTL/Captiva/Equivalent make with approval of the authority) 1250 KVA |
| 371 | Providing and Laying of Clear Water Rising Main Of Dia 200mm to 450mm DI K-9 and Length- 12703m |
| 372 | Earthwork Excavation-Ord soilEarth work in all kinds of soil (Oridinary + Hard + Stony+ Slushy) |
| 373 | 0-1.5 m |
| 374 | Earth Work Excavation-Hard soilExcavation of founation in laterite rock or any hard rock (other than granite) |
| 375 | 0-1.5 m |
| 376 | 1.5 to 3.0 m |
| 377 | Supplying all labour, material, tools & plants for dismantling of bituminous courses of flexible pavements and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials separately, all complete as per specification and direction of Engineer-in-charge. |
| 378 | Supplying all materials labour & T&P and providing (1:3:6) for C.C works with 40mm size hard granite metal including cost of all materials conveyance rovality etc. all complete. |
| 379 | Laying and Jointing of Pipe Material |
| 380 | Supplying & laying of DI pipes in trench : Supplying pipes, all other material,labour, T & P and laying of centrifugally cast(spun) Ductile Iron (DI) pressure pipes with socket and spigot ends in trenches for transportation of sewage conforming to IS - 8329 in standard lengths of class-K9 suitable for tyton joints(rubber gasket jointing) including cutting the pipes to required length, lowering and aligning the pipes inside trench, testing the pipe lines with required water pressure and commissioning including taxes & duties etc all complete as per specification and direction of the Engineer(excluding earth work in excavation, back filling, jointing and disposal of surplus earth).DI K-9 Pipe |
| 381 | 200 mm |
| 382 | 250 mm |
| 383 | 350 mm |
| 384 | 400 mm |
| 385 | 450 mm |
| 386 | Supplying and laying of DI fittings : Supplying fittings and all other material, labour, T & P and laying in trenches DI fittings for following pipes conforming to IS : 9523 and fixing with the pipes after cutting the pipes to required length, shape and size including wastages etc with pressure rating PN-1 of following nominal diameter, testing the joints with required water pressure including taxes & duties etc all complete as per specification and direction of the Engineer. |
| 387 | for 100 mm to 300 mm dia |
| 388 | for 350 mm & Above |
| 389 | Supplying all materials, labour and T&P for Providing Push-on-joints confirming to IS:3114 to centrifugally (Spun) Ductile Iron pipes using rubber gasket conforming to IS:5382 of Styrene Butadiene Rubber (S.B.R) quality , testing of joints, etc. all complete as per specification and direction of Engineer-in-Charge including supplying of all labour, material, tools & plants required to perform the work. |
| 390 | 200 mm |
| 391 | 250 mm |
| 392 | 350 mm |
| 393 | 400 mm |
| 394 | 450 mm |
| 395 | Providing and fixing of DI mechanical joint socket conforming to IS 13382/92 to flanged ends of DI Pipes including supply of all material, labour tools & plants and testing of joints, etc. all complete as per specification and direction of Engineer-in-Charge including supplying of all labour, material, tools & plants required to perform the work |
| 396 | 150 mm |
| 397 | 200 mm |
| 398 | 250 mm |
| 399 | 350 mm |
| 400 | 400 mm |
| 401 | 450 mm |
| 402 | Supplying all materials Labour & T & P for Fixing ductile iron Non Rising Spindle type metal seated Sluice Valve confirming to IS 14846 PN-1.6 with double flanged ends for water works purposes for the following nominal diameters as per specification complete including cost of Sluice valve .(Make- VAG/ Talis/ AVK/IVC/ Kirloskar/Equivalent make with approval of the authority) |
| 403 | 200 mm |
| 404 | 250 mm |
| 405 | 350 mm |
| 406 | 400 mm |
| 407 | 450 mm |
| 408 | Supplying, Fitting,Commissioning,Fixing double chamber control valve solenoied control,hydraulic operated for operating pressure 1.0-2.0 Kg/cm2 Body A216 WCB integrated with PLC pannel for operation (local/remort and web enabled with command and control) of (Make-VAG/ Talis/ AVK/IVC/ Kirloskar/Equivalent make with approval of the authority) to control water supply including the cost of valve cutting the pipeline & making good to the damages including cost of all labours, T&P etc. all complete as per the direction of Engineer-in-charge. |
| 409 | 200 mm Dia |
| 410 | 250 mm Dia |
| 411 | Supply of electric powered electromagnetic full bore type IP 68 Fully welded Flanged type water flow meter of Pulse DC type of Flow tube SS304,coilhousing & electrodes SS316,SS RING TYPE grounding etc with IP 68 signal coverter remote mounting,input power supply 24V DC 4 - 20 mA,programable LCD display to show Actual flow rate,totalised flow, flow direction, flow velocity,conductivity with + or - 0.5% accuracy etc & provision to diagnostics empty pipe detection, coil tempreture, coil resitance etc & comptable to data communication modules with masibus & communicaton the data to remote SCADA station for live monitoning where ever required including providing data cable & power cable required as per site condition. The standard callbratation certificate & guaantee certificate for flow meter & electromagnetic signal coverter to be given for minumum one year from the date of installation. (Make- KROHNE MARSHALL/E&H/ABB/SIEMENS/Equivalent make with approval of authority) including cost material with all taxes transportation to Site/Storage with insurance.). All complete as per direction of Engineer in charge. |
| 412 | 200mm dia |
| 413 | 250mm dia |
| 414 | 400mm dia (At Header) |
| 415 | 450mm dia (At Header) |
| 416 | Providing and fixing DI Tamper proof Kinetic Air Valve of approved quality with bolts, nuts, rubber insertions etc. complete ( including the tail piece, tapers etc. complete). Heavy Duty suitable for working pressure up to 10kg/Cm2 with isolating valve conforming to IS 14845 (Make-VAG/ Talis/ AVK/IVC/ Kirloskar/Equivalent make with approval of the authority) |
| 417 | 50 mm |
| 418 | 100 mm |
| 419 | 150 mm |
| 420 | Pressure Transmitter :Designing, Supplying, Installing, commissioning & testing of pressure transmitter CE markd with following technical parameters at Raw Water Pump House and Interfacing with PLC panel including mounting arrangement along with snubber and needle valve, 1.0 sq.mm 2 core copper braided screen cable Wire, screw, grip & clamp for DI / MS pipe fitting.Output 4-20 mA / HART (With Display )(Make-E & H/ABB/VEGA/WIKA/Equivalent make with approval of authority) |
| 421 | Supply, Fitting, Fixing & Commisssioning of DI Dismantling Joint including cost of all labours, T&P etc all complete as per direction of Engineer-in-Charge. |
| 422 | 200mm dia |
| 423 | 250mm dia |
| 424 | 400mm dia |
| 425 | 450mm dia |
| 426 | 700mm dia (at Intake) |
| 427 | Supplying all ,materials, labour, T & P for refilling the trenches with excavated materials within 50M initial lead and 1.5M initial lift etc. all complete. |
| 428 | Disposal of debris/surplus excavated earth to the site about 10 km away from the work siteetc., complete as per standard detailed technical specifications and approved design and drawings and any other incidental charges, hire charges of machinaries, loading and unloading charges with all lead and lift and as directed by the Engineer-in-charge. |
| 429 | RCC Valve Chamber |
| 430 | Supplying all materials,labour and T&P for Construction of RCC valve chamber in (1:1.5:3 ) mix with foundation concrete, R.C.C. cover slab with SFRC SD-20 cover , inside plaster 12mm. thick with cement mortar (1:3) finished with neat cement punning, 12mm. thick out side plaster (1:3) including earth work excavation in foundation and refilling the cavity with excavated earth etc all complete as per direction of Engineer in charge. |
| 431 | Size ( 0.75 X0.75 X1.25)M |
| 432 | Size ( 0.9 X0.9 X1.25)M |
| 433 | Size ( 1.2 X1.2 X1.2)M |
| 434 | Constructing RCC Thrust blocks |
| 435 | Earth work in all Kind of soil within 50m, initial lead and 1.5m, initial lift including rought dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-charge |
| 436 | 200 mm Dia (15 Nos.) |
| 437 | 250 mm Dia (50 Nos.) |
| 438 | 350 mm Dia (38 Nos.) |
| 439 | 400 mm Dia (17 Nos.) |
| 440 | 450 mm Dia (9 Nos.) |
| 441 | Supplying all materials labour & T&P and providing (1:3:6) for C.C works with 40mm size hard granite metal including cost of all materials conveyance rovality etc. all complete. |
| 442 | 200 mm Dia (15 Nos.) |
| 443 | 250 mm Dia (50 Nos.) |
| 444 | 350 mm Dia (38 Nos.) |
| 445 | 400 mm Dia (17 Nos.) |
| 446 | 450 mm Dia (9 Nos.) |
| 447 | R.C.C work in ground floor of M-25 grade with 20mm & down grade crusher broken hard Granite chips including hoisting & laying with cost of all labour, materials with all taxes, lead ,T & P etc all complete .including cost of binding wire, centering & strutting, including labour charges, backfilling, carting of extra earth etc complete for finished item of work and as directed by the Engineer-in-charge |
| 448 | 200 mm Dia (15 Nos.) |
| 449 | 250 mm Dia (50 Nos.) |
| 450 | 350 mm Dia (38 Nos.) |
| 451 | 400 mm Dia (17 Nos.) |
| 452 | 450 mm Dia (9 Nos.) |
| 453 | Rigid smooth centring and shutteringR.C.C. Foundation, Plinth Band, Footings, Column Base, Mass Concrete & Precast Slabs |
| 454 | 200 mm Dia (15 Nos.) |
| 455 | 250 mm Dia (50 Nos.) |
| 456 | 350 mm Dia (38 Nos.) |
| 457 | 400 mm Dia (17 Nos.) |
| 458 | 450 mm Dia (9 Nos.) |
| 459 | Supply and fabrication mild steel or tor steel bars of all size for reinforcement of RCC works including conveying steel to workspot with all lead including cleaning straighteing, bending, fabricating, placing in position, being as per designs including cost of binding wire hoisting all lift (Steel shall be procured from SAIL/TATA/Vizag STEEL TMT-EQR 500/IS 1786 Fe 500 D and test certificate shall be furnished)with all lead and lift etc., complete |
| 460 | 200 mm Dia (15 Nos.) |
| 461 | 250 mm Dia (50 Nos.) |
| 462 | 350 mm Dia (38 Nos.) |
| 463 | 400 mm Dia (17 Nos.) |
| 464 | 450 mm Dia (9 Nos.) |
| 465 | Road Crossing & Canal Crossing |
| 466 | Providing and Laying 250 mm Dia. to 700 mm Dia. MS Pipe By Micro Tunneling Crossing Method for National Highway and State Highway In Clear Water Rising Main. |
| 467 | Installation of product pipe by Micro Tunneling method including making of entry and exit pits, all related civil works like excavation, shoring/strutting, etc. and Ground Penetrating Radar Survey, to protect any existing utilities at the pipe installation location and restoration of site after completion.(upto 100 meter of installation length) |
| 468 | Location 01 (SH) 450 mm Dia 8 mm Thik Pipe at 2 places |
| 469 | Location 02 (NH) 600 mm Dia 8 mm Thik Pipe |
| 470 | Location 03 (NH) 700 mm Dia 8 mm Thik Pipe |
| 471 | Manufacturing, providing and supplying spirally welded / ERW / SAW / fabricated and hydraulic testing of M.S. pipes (Commercial Quality) including procurements of plates, gas cutting to required size rolling, track welding assembling in suitable lengths to form pipes, welding on automatic welding machine and forming 'V' edge on both ends of pipes including all taxes (Central & local), railway freight, insurance unloading from railway wagon, loading into truck, transport to stores/ site, unloading, stacking, etc, complete as per IS- 3589 and IS- 5504 as applicable as per specifications (No negative tolerance in thickness is permissible).Excluding painting |
| 472 | Casing Pipe |
| 473 | Location 01 450 mm Dia 8 mm Thik Pipe For Casing at 2 places |
| 474 | Location 02 600 mm Dia 8 mm Thik Pipe For Casing |
| 475 | Location 03 700 mm Dia 8 mm Thik Pipe For Casing |
| 476 | Carrier Pipe |
| 477 | Location 01 250 mm Dia 6.3 mm Thik Pipe as carrier at 2 places |
| 478 | Location 02 400 mm Dia 8 mm Thik Pipe as carrier |
| 479 | Location 03 500 mm Dia 8 mm Thik Pipe as carrier |
| 480 | Supply & application of EPIDEC Epoxy Painting two coats with any approved paintover a coat of Epoxy primer including cost of all labour, materials T & P with taxes, transportation etc all complete in Ground Floor. |
| 481 | Welding with two welding beads/pass, conforming to IS:816-1998 (Single 60° Butt/ fillet weld) to MS pipes and fittings at site |
| 482 | 12 mm Plate Thik |
| 483 | Construction of Structural Steel bridge on Canal crossing (Raft/Pile) |
| 484 | Earthwork Excavation- Earth work in all kinds of soil (Oridinary + Hard + Stony+ Slushy) |
| 485 | 0-1.5 m |
| 486 | 1.5 to 3.0 m |
| 487 | Earth Work Excavation-Excavation of founation in laterite rock or any hard rock (other than granite) |
| 488 | 1.5 to 3.0 m |
| 489 | Providing, constructing coffer dam in river basin / dam storages as per type design includingexcavation, filling themiddleportion with B.C. soil (in gunny bags if required). Providing impervious / semiperviousmaterials onbothsidesof B.C. soil (ingunnybags if required) includingramming,compactingtothe satisfaction of Engineer-in-charge till the completion of work includingdismantling coffer dam after completion of works and disposingoff thematerial asdirectedby the Engineer-in-charge. |
| 490 | Providing cement concrete (1:3:6) with 40mm size C.B.H.G. chips in floor including supplying all labour, materials, T & P and cost, conveyance, royalties, taxes, etc(100mm thickness). All complete as per specification and direction of Engineer-in-charge. |
| 491 | R.C.C work in ground floor of M-25 grade with 20mm & down grade crusher broken Granite chips (M-25) M-25 Raft/Pile foundation ,Column ,Beam ,RCC wall & Slab |
| 492 | 0-1.5 m |
| 493 | 1.5 to 4.5 m |
| 494 | 4.5 to 7.5 m |
| 495 | Supplying, fitting and placing uncoated HYSD bar |
| 496 | 0-1.5 m |
| 497 | 1.5 to 4.5 m |
| 498 | 4.5 to 7.5 m |
| 499 | R.C.C. Raft/Pile Foundation, Plinth Band, Footings, Column Base, Mass Concrete & Precast Slabs |
| 500 | 1.5 to 4.5 m |
| 501 | R.C.C. Beams, Column, Grider and Bressmer |
| 502 | 0-1.5 m |
| 503 | 1.5 to 4.5 m |
| 504 | 4.5 to 7.5 m |
| 505 | Supply & application of EPIDEC Epoxy Painting two coats with any approved paintover a coat of Epoxy primer including cost of all labour, materials T & P with taxes, transportation etc all complete in Ground Floor. |
| 506 | Supplying all materials,labour and T&P for fitting and fixing of ISMB 300,ISMC 300,ISA 100,ISA 50,Gusset Plate 8mm Thick,bolts & nuts etc including cutting,welding & placing in position for nallah crossing bridge all complete as per the direction of Engineer in charge. |
| 507 | Non-rusting paint to structural steel |
| 508 | Single under reamed pile foundation with RCC M20 using 12mm size black hard granite (Crusher broken) stone chips including cost of boring but excluding cost of M.S./Tor steel and labour charges for cutting, bending and binding of steel. 375 mm dia.12 Mtr. depth with soil testing and design etc. as per direction of Engineer-in-charge. |
| 509 | Filling in trenches with approved excavated material from foundation. |
| 510 | Disposing surplus excavated material at the lead of 5 km as directed. |
| 511 | Dewatering the excavated trenches and pools of water in the building trenches /pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour,fuel),etc.complete.(Bd-A-9/261) |
| 512 | Road Restoration |
| 513 | Road Restoration for Raw Water Rising Main. |
| 514 | Road Cutting |
| 515 | Cutting asphalt or bituminous road of flexible pavments and disposal of dismantalled materials up a lead of 1000 mtr stacking servicable and unservicable materials separately including cost of all labour, T & P etc. all complete as per the direction of engineer-in-charge. |
| 516 | Road Restoration |
| 517 | Construction of granular sub base by providing closed gradded granular sub base Gradding -IV materials as per table 400-1 spreading in uniform layers with mortor grader on prepared surface, mixing by in place method with rovator at OMC and campacting with vibratory roller to achieve the desired density complete as per clause 401 of MoSRT&H specification for road & bridge work etc complete. |
| 518 | Providing and laying spreding and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the materials with watered at OMC in Mechanical mix plant, carriage of mixed materials by tipper to site, laying inuniform layer with paver in subbase /base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per clause 406 of MoSRT&H specification for road and bridge work (latest revision) |
| 519 | Providing tack coat on preppared surface with bitumen emulsion as per technical specification and as per Clause - 503 of MoSRT&H specification for Road & bridge work (latest Revision) |
| 520 | Providing 50 mm thick Bitumen Macadam using crushed stone Gradding II materials & 60/70 penetration grade of bitumen as per approved drawing & technical Specification and as per Clause - 504 of MoSRT&H specification for Road & bridge work (latest Rivision) |
| 521 | Providing 25mm Thick semi Dence Bituminous concrete using crushed stone Gr-II materials & 60/70 penitration grade of bitumen as per approved Drawings & technical Specification and as per Clause 506 of MoSRT&H Specification for Roads and Bridge works (Latest Revision) |
| 522 | Road Reinstating of CC Road |
| 523 | Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately |
| 524 | CC(1:3:6) with 4cm.hand broken Granite metal |
| 525 | R.C.C work in ground floor of M-25 grade with 20mm & down grade crusher broken Granite chips (M-25) |
| 526 | Road Restoration for Clear Water Rising Main. |
| 527 | Road Cutting |
| 528 | Cutting asphalt or bituminous road of flexible pavments and disposal of dismantalled materials up a lead of 1000 mtr stacking servicable and unservicable materials separately including cost of all labour, T & P etc. all complete as per the direction of engineer-in-charge. |
| 529 | Road Restoration |
| 530 | Construction of granular sub base by providing closed gradded granular sub base Gradding -IV materials as per table 400-1 spreading in uniform layers with mortor grader on prepared surface, mixing by in place method with rovator at OMC and campacting with vibratory roller to achieve the desired density complete as per clause 401 of MoSRT&H specification for road & bridge work etc complete. |
| 531 | Providing and laying spreding and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the materials with watered at OMC in Mechanical mix plant, carriage of mixed materials by tipper to site, laying inuniform layer with paver in subbase /base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per clause 406 of MoSRT&H specification for road and bridge work (latest revision) |
| 532 | providing tack coat on preppared surface with bitumen emulsion as per technical specification and as per Clause - 503 of MoSRT&H specification for Road & bridge work (latest Revision) |
| 533 | dewatering the excavated trenches and pools of water in the building trenches /pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, la |
| 534 | Providing 25mm Thick semi Dence Bituminous concrete using crushed stone Gr-II materials & 60/70 penitration grade of bitumen as per approved Drawings & technical Specification and as per Clause 506 of MoSRT&H Specification for Roads and Bridge works (Latest Revision) |
| 535 | Road Reinstating of CC Road |
| 536 | Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately |
| 537 | CC(1:3:6) with 4cm.hand broken Granite metal |
| 538 | R.C.C work in ground floor of M-25 grade with 20mm & down grade crusher broken Granite chips (M-25) |
| 539 | Supply, installation, testing and commissioning of a 3-phase, 33/0.415 kV LT power supply system including installation of door-type transformer with On-Load Tap Changer (OLTC), copper wound, along with 33 kV source metering, complete with all associated materials, accessories and fittings, in all respects as per relevant electrical standards and IS specifications including providing and installing 33 kV VCB panels for incoming and outgoing feeders, outdoor type, with a 6-pole substation including 33 kV isolator and metering panel at the source station, complete as per utility norms and requirements,33kV HT Panel (1 Incomer + 2 Outgoing for 2 transformers + 1 Bus coupler)(630A VCB),supplying & laying 33kV, 3C XLPE Aluminium armoured power cable of required size all complete as per standard & estimate prescribed by TPCODL.(For Intake well & WTP) |
| 540 | SITC (Under Ground) of 33kV, 3C x 120 sq.mm XLPE armoured cable (Aluminium) |
| 541 | For Proposed Intake |
| 542 | For Proposed WTP |
| 543 | Providing and installing 33 kV VCB panels for incoming and outgoing feeders, outdoor type, with a 6-pole substation including 33 kV isolator and metering panel at the source station, complete as per utility norms and requirements |
| 544 | c. Supply, installation, testing and commissioning of a 3-phase Transformer (Sub Station), 33/0.415 kV LT power supply system including installation of an indoor-type transformer with On-Load Tap Changer (OLTC), copper wound, along with 33 kV source metering, complete with all associated materials, accessories and fittings, in all respects as per relevant electrical standards and IS specifications |
| 545 | For Proposed Intake Well -including installation with all required material KVA |
| 546 | For Proposed WTP-including installation with all required material KVA |
| 547 | 33kV HT Panel (1 Incomer + 2 Outgoing for 2 transformers + 1 Bus coupler)(630A VCB) |
| 548 | Operation & maintenance for 5 Years excluding Electrical charge |
| 549 | 1st year O & M |
| 550 | 2nd year O & M |
| 551 | 3rd Year O & M |
| 552 | 4th Year O & M |
| 553 | 5th Year O & M Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysAug 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender