Tender For Construction Work Of Hostel/Barrack And Investigation Room With A Capacity Of 32 Personnel In The Premises Of Police Station Kheri Located In Dist. Lakhimpur Kheri
Tender Overview
Project Description
Tender for Construction Work Of Hostel/Barrack And Investigation Room With A Capacity Of 32 Personnel In The Premises Of Police Station Kheri Located In Dist. Lakhimpur Kheri
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 28-Jul-2026 | Date | Date | 04-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in foundation for Structure as per drawing and technical specification including setting out, construction shoring and bracing removal of Stumps and other deleterious and disposal upto lead of 50m dressing of sides and bottam and backfilling in trenches with excavated with excavated suitable material + Vivechna Room |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement 4 coarse sand (zone-III): 8 graded stone aggregate 40 mm (nominal size) |
| 3 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. DSR-2.25a |
| 4 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 5 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement: 2 Coarse sand) to match the existing floor: 4. Treatment of soil along external perimter 7.5 liters/Sqm (5) Treatment of soil along external perimter 5 liters/Sqm |
| 6 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in Footing foundation excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item. |
| 7 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in Ground Beam excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item. |
| 8 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in Plinth Beam excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item. |
| 9 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) (Column)(Ground Floor+First+Second+Third) |
| 10 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in Lintel excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item(Ground Floor+First+Second+Third) |
| 11 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in Projection excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item(Ground Floor+First+Second+Third) |
| 12 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in Beam excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item(Ground Floor+First+Second+Third) |
| 13 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in Slab excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item(Ground Floor+First+Second+Third) |
| 14 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks.(Ground Floor+First+Second+Third) |
| 15 | Class-150 (non moduler) Brick work in 1:6 cement & core sand mortar in foundation & plinth and also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:6 cement & coarse sand) (230mm wall) |
| 16 | Brick work in super-structure above plinth level up to floor two level (up to two storeys) including necessary cutting and moulding of bricks as required and also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:6 cement & coarse sand) (230mm wall)(Ground Floor+First+Second+Third) |
| 17 | Same as iteam no.16 But in 1:4 cemant & Coare sand mortar wall cutting and moulding of bricks as required and also including honey comb brick work thickness of 12 cm & Below brick work (Ground Floor+First+Second+Third) |
| 18 | Mild steel or iron work of small sizes and sections such as hold fast etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. (Ground Floor+First+Second+Third) |
| 19 | Providing and fixing angle iron frame for door & window of mild steel angel section of size 35x35x5 mm, joint & belded by angli iron 35x35x5 mm etc complete. |
| 20 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. |
| 21 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (35mm thick)(Ground Floor+First+Second+Third) |
| 22 | Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer's specification and direction of Engineer- in-Charge. |
| 23 | Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer's specification & drawing |
| 24 | Structural steel work Z-Section in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 25 | Structural steel work Grill in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.(Ground Floor+First+Second+Third) |
| 26 | Providing & Fixing Glass panes with puty and glazing clips in steeldoor, windows ,clerestory window,all complete with 4.00mm thick float glass.(Ground Floor+First+Second+Third) |
| 27 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 28 | Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with approved steel primer all complete. |
| 29 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 35 mm thick shutters Kiln seasoned and chemically treated hollock wood |
| 30 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides |
| 31 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete in Vivechna Room 250x16mm |
| 32 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete in Vivechna Room :250x16mm |
| 33 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :in Vivechna Room 125mm |
| 34 | 12mm thick plaster in inner walls with proportion of 1:6 cement & approved coarse sand of singke coat for interior olaser including internal rounded angles chamfers, and roundded angles exceeding 80mm In girth and finished even and smooth (Interior side)Ground Floor |
| 35 | 12mm thick plaster in inner walls with proportion of 1:6 cement & approved coarse sand of singke coat for interior olaser including internal rounded angles chamfers, and roundded angles exceeding 80mm In girth and finished even and smooth Exterior side) |
| 36 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm) |
| 37 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 38 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 39 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (40mm) |
| 40 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3(1 cement : 3 coarse sand), finished with a floating coat of neat cement. |
| 41 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : |
| 42 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. (Kajaria. Somany or Equivalent) |
| 43 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:3 (1 cement : 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. (Kajaria. Somany or Equivalent) |
| 44 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red |
| 45 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1: 1.5 : 3 (M-20) in foundation and footing excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item. As per SI No.DSR 5.2.2 |
| 46 | Supply & Fixing Murga Jali |
| 47 | Providing & Applying high quality acrylic modified resin based texture of Dholpur/Red sand stone Pattern with anti algae and UV resistance properties to be applied as intermediate finish in desired pattern @ 43.04 kgs/10 sqm to form film of 1- 1.5 mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plaster surface, followed by top coating with Premium Acrylic Smooth exterior paint with Silicone additives of required shade by two or more coats @ 1.43 litres/10 sqm, complete as the direction of Engineer -in-Charge. AS Per DSR 22.24 A |
| 48 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surfaceto prepare the surface even and smooth complete. |
| 49 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 50 | Finishing walls with Primium Acrylic Smooth exterior paint of required shade :New work (Two or more cpat applied @ 1.43 litre/ sqm over and including prime coat of exterior primer aplied @ of 2.20 kg/10 Sqm) Apex Ultima Weather coat All guard Asian, Berger |
| 51 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.13.85.1 With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC contentless than 50 grams/ litre |
| 52 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 53 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone ): 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth |
| 54 | Apron Drain |
| 55 | Centering and shuttering including strutting, propping etc. and removal of form work for : footings, bases for columns |
| 56 | Centering and shuttering including strutting, propping etc. and removal of form work with water proof ply 12mm thick :Plinth Beam/Band, |
| 57 | Centering and shuttering including strutting, propping etc. and removal of form work for :Columns |
| 58 | Centering and shuttering including strutting, propping etc. and removal of form work with water proof ply 12mm thick :Lintel Band |
| 59 | Centering and shuttering including strutting, propping etc. and removal of form work with water proof ply 12mm thick : Projection |
| 60 | Centering and shuttering including strutting, propping etc. and removal of form work with water proof ply 12mm thick :Beam |
| 61 | Centering and shuttering including strutting, propping etc. and removal of form work with water proof ply 12mm thick :Slab |
| 62 | Sanitary Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 63 | W.C Pain with ISI Marked Solid plasatic seat and lid in Vivechna Room |
| 64 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 65 | White Vitreous China wash basin size 630x 450 mm with a pair of 15 mm C.P. brass pillar tap in Vivechna Room |
| 66 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:kitchen sink without Drain board 510x1040 mm bowl depth 250 mm |
| 67 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 68 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 69 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Flexible pipei) 32+40 mm dia |
| 70 | Providing and fixing Soil, wast and vent pipe clips centrifugallu cast (Spun) iron socket & spigot (S&S) pipe as per IS:398975 mm O.D |
| 71 | 110 mm O.D. |
| 72 | Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.75 mm |
| 73 | Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. + Vivachna Room110 mm |
| 74 | Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes :75 mm O.D. |
| 75 | 110 mm O.D. |
| 76 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :75mm |
| 77 | 110 mm |
| 78 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion in Vivechna Room 110 mm Shoe |
| 79 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Shoe (Plain)75 mm Shoe |
| 80 | 110 mm Shoe |
| 81 | Vivachna Room Coupler110 mm Bend |
| 82 | Bend 87.5 Degree 110 mm Bend |
| 83 | Shoe (Plain) 110 mm Shoe |
| 84 | Providing and fixing plain bend of required degree. Sand cast iron S&S as per IS - 398975 mm size |
| 85 | 110 mm size |
| 86 | Providing and fixing heel rest sanitary bend Sand cast iron S&S as per IS - 398975mm Size |
| 87 | 100 mm size |
| 88 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. Sand cast iron S&S as per IS - 398975 mm size |
| 89 | 100 mm size |
| 90 | Providing and fixing terminal guard : Sand cast iron S&S as per IS - 398975 mm size |
| 91 | 100 mm size |
| 92 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : |
| 93 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall 15 mm nominal outer dia pipes |
| 94 | 20 mm nominal outer dia pipes |
| 95 | 25 mm nominal outer dia pipes |
| 96 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall20 mm nominal outer dia Pipes |
| 97 | 25 mm nominal outer dia Pipes |
| 98 | 32mm nominal outer dia Pipes |
| 99 | Vivechna Room15 mm nominal outer dia Pipes |
| 100 | 20 mm nominal outer dia Pipes |
| 101 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge Concealed work including cutting chase & making good the wall etc.15 mm nominal outer dia Pipes |
| 102 | 20 mm nominal outer dia Pipes |
| 103 | Vivechna Room20 mm nominal outer dia Pipes |
| 104 | Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends)25mm dia, nominal bore |
| 105 | Vivechna Room20mm dia, nominal bore |
| 106 | 25mm dia, nominal bore |
| 107 | Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm Long15 mm nominal bore |
| 108 | Providing and fixing G.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work)20 mm nominal bore |
| 109 | 25 mm nominal bore |
| 110 | Providing and fixing C.P. brass bib cock of approved quality confirming to IS:893115 mm nominal bore |
| 111 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore |
| 112 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. |
| 113 | Providing and fixing brass stop cock of approved quality. 20 mm Norminal Bore vivechna room |
| 114 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 115 | Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming, watering etc. stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50m pipes cable etc exceeding 80 mm dia but not exceeding 300 mm |
| 116 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150mm O.D |
| 117 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 160/150 mm diameter pipe |
| 118 | Vivachna Room 100 mm diameter pipe |
| 119 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 180x150 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 120 | Vivechna Room |
| 121 | Providing, laying and jointing glazed stoneware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 110 mm diameter Vivchna Room |
| 122 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Fisnihed with a floating coat of neat cement complete as per standard design :Inside size 90x80 cm and 45 cm deep including C.I. coverwith frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5(a) Size 900 x 800 mmWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 123 | Extra over Item No. 24.27 for every additional 2023 depth of 0.10 metre or part there of main hole.Size 900 x 800 mmWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 124 | rain water pipe 100 mm dia pvc |
| 125 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in Vivchna Room |
| 126 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : with a floating coat of neat cement complete as per standard design With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 in Vivechna room |
| 127 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar in Vivechna Room |
| 128 | Providing and fixing in floor and wall face Ringfit UPVC ASTRAL/EQUIVALENT ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring. (i) Double socketed pipes.110 mm dia P.V.C Pipe in Vivechna Room |
| 129 | 90 mm dia P.V.C Pipe |
| 130 | Providing & fixing UPVC Floor trap of self cleansing design with CP Jali complete in all respects. (Make : Supreme / Finolex / Prince) in Vivechna Room P trape type floor Trap 110x90 mm |
| 131 | SepticTank Earth work in excavation (2.1.1 ) |
| 132 | P.C.C. in 1 : 4: 8 with cement, c.sand & 40 mm gauge stone ballast (4.1.8) |
| 133 | Brick work in foundation in 1 : 4cement & coarse sand(6.1.1) |
| 134 | R. C. C. in 1 : 1.5 : 3 in Slab (5.3) |
| 135 | Reinforcement Work (5.22.6) |
| 136 | Brick work in 1 : 4 cement & coarse Sand (4.1.8) |
| 137 | 40mm thick c.c. flooring (11.3.1) |
| 138 | 18 mm thick plaster in 1:4 cement & Course sand (DSR-11.6.1) |
| 139 | Supply & Febrication of M. S. Steps (DSR-10.2) |
| 140 | 500 mm diameter C.I. cover (medium duty) the cover to be not less than 58 kg (DSR 19.18.2) |
| 141 | C.I. Cowel (DSR 17.56.1.2) |
| 142 | C.I. Plain bend (DSR 17.39.1.2) |
| 143 | C.I. Single equal plaing junction (DSR 17.44.1.2) |
| 144 | ELECTRICAL WORKSPOINT WIRINGWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C |
| 145 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular type switch, modular plate, suitable G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 146 | Wiring for circuit/sub-main wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2X1.5 sqmm + 1x1.5 sqmm earth wire |
| 147 | 2X2.5 sqmm + 1x 2.5 sqmm earth wire |
| 148 | 2X4.0 sqmm + 1x 4.0 sqmm earth wire |
| 149 | 4X6 sqmm + 2x 6.0 sqmm earth wire |
| 150 | Supply and fixing of stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 151 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 152 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch,connection etc. as required. |
| 153 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,connection etc. as required. |
| 154 | Supplying and fixing 3 pin 5 A ceiling rose on the existing junction box/woodedn block including connectionetc. as required. |
| 155 | Supplying and fixing brass batten/angle holder including connectionetc. as required. |
| 156 | Instalation,testing & commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLSCFL/LED lamps per fitting, complete with all accessories including connection etc. as required. |
| 157 | Installation, testing and commissioning of prewired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. PVC insulated, copper conductor, single core cable etc. as required. |
| 158 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. Including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 159 | Installation of exhaust fan in the existing opening, including making good the damage, connections, testing, commissioning etc. as required. Upto 450 mm sweep |
| 160 | Extra for fixing the louvers / shutters complete with frame fro exhaust fans of all sizes. |
| 161 | Providing and fixing circular/Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screwed, one loc at the conrners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 162 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Disect Current(BLDC) motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value(CM/M/W) minimum 6, Air delivery minimum 210 Cum/Min, 350 RPM(tolerance as per IS: 374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75 degree C(max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 163 | Supplying and fixing following way, Horizontal type three pole and neutral MCB distribution board, 415 volts on surface /recess complete with , tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). in 4 way (4 + 12), Double door |
| 164 | Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C' series, miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. single pole |
| 165 | Supplying and fixing single pole, blanking plate in the existing MCB DB complete etc. as required.in Vivechna room |
| 166 | Supply and fixing following rateing four pole, 415 V, isolator in the existing existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 167 | Providing and fixing M.V. danger notice plate of 200 mmx150 mm, made of mild steelm at least 2 mm thick, and viterous enameled whithe on bothe sides, and with incription in single red colour on front side as required. |
| 168 | Suplying and fixing cable end box(Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution borad, 415 Volts, on surface/recess, complete with testing and commissoning ect. As required. For 4 way, Double Door TPNMCBDB |
| 169 | Earthing with GI earth pipe, 600 mm X 600 mm X 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc, with charcoal/cock and salt as required. |
| 170 | Supplying and Laying of 25 mm X 3 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required.( jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 171 | Supplying and Laying of 6 SWG G.I wire at 0.50 metre below ground level for conductor earth electrode, including connection / terminating with G.I. thimble etc. as required. |
| 172 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.in Upto 35 sq. mm |
| 173 | Supplying & making end termination with brass compression gland and aluminium lugs for the following size of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5x25 Sqmm (28mm) |
| 174 | Vivechna Room4x10 Sqmm(25mm) |
| 175 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required 80 mm Dia(Rate taken From Civil DSR 2023-18.12) |
| 176 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required in Vivechna room80 mm Dia(Rate taken From Civil DSR 2023-18.12) |
| 177 | Supplying and drawing following pair 0.5 sqmm FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. 2 Pair in vivechna room |
| 178 | Supply and fixing of following size of PVC conduit alongwith the accessories in recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: 25 mm in vivechna room |
| 179 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. Telephone socket outlet in Vivechna room |
| 180 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,connection etc. as required. |
| 181 | Supply of following size of 1.1 KV grade multicore aluminium conductor PVC sheathed armoured cable as per IS 1554. Make-Polycab or Eq 25sqmm 3.5 core |
| 182 | Supply of following size of 1.1 KV grade multicore aluminium conductor PVC sheathed armoured cable as per IS 1554. Make-Polycab or Eq 25sqmm 3.5 core in Vivechna Room10 Sqmm 4 core |
| 183 | Supply of 1X17 W mirror light complete in all respects. Make-Philips or Eq |
| 184 | Supply of 12 W LED BULB complete in all respect. Make-Philips or Eq |
| 185 | Supply of LED Tube Light with batten suitable for up to 1X20 watt LED tube light complete including tube etc. on surface/Pendent complete in all respect.Make-Philips or Eq |
| 186 | Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB’s (Four Pole 36 KA with thermal magnatic release) Switches complete and instrument chamber etc. complete in transformer with deteachable side covers and shall be suitable for extension on the sides. The MCCB’s shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. |
| 187 | Supply of AC 230/250 Volts, 50 Hz 55w 1400 rpm exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required.Make: Havells-STANDARD -Refresh Air-SPS |
| 188 | FIRE FIGHTING SYSTEM Supply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 189 | Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 190 | Boundary WallConstruction of Boundry Wall For Campus |
| 191 | Construction of Gate For Boundry Wall |
| 192 | Construction of Soakpit |
| 193 | Providing and Instalation of Submersible Pump etc complete. |
| 194 | Construction of Strom Water drain |
| 195 | Construction of Interlocking For Campus Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender