Tender For Detailed Design Consultancy For Design Of 25 Kv Overhead Equipment (Ohe) System For The Elevated Lines, Power Supply & Scada For Both Underground And Elevated Lines Including Checking Of Design Of Receiving Substations And Design Validatio
Tender Overview
Project Description
Tender for Detailed Design Consultancy For Design Of 25 Kv Overhead Equipment (Ohe) System For The Elevated Lines, Power Supply & Scada For Both Underground And Elevated Lines Including Checking Of Design Of Receiving Substations And Design Validation Of 2 Corridors Of Dmrc Phase-Iv Project And Jaipur Metro Phase-2 Project
BOQ
| Sl. No. | Item Description |
| 1 | Grand Total of Schedule-A of Contract D2EDD-02 Contract D2EDD-02:- Detailed Design Consultancy for Design of 25 kV Overhead Equipment (OHE) system for the elevated lines, Power Supply & SCADA for both Underground and Elevated lines including checking of Design of Receiving Substations and Design Validation of 2 corridors of DMRC Phase-IV Project and Jaipur Metro Phase-2 Project Schedule-A Schedule Corridor Unit Quantity Unit rate(INR)(Without Taxes) Total Amount(INR)(Without Taxes) Total Tax(INR)(GST @18%) Total Amount(INR)(With Taxes i.e. GST@18%) (A) (B) (C = A * B) (D = C * 18%) (E = C + D) Schedule-I CORRIDOR- Lajpat Nagar to Saket G Block (DMRC Phase-IV) Lot 1.0 7914192.0 7914192.0 1424554.56 9338746.56 Schedule-II CORRIDOR- Rithala-Narela-Kundli(DMRC Phase-IV) Lot 1.0 24961794.0 24961794.0 4493122.92 29454916.92 Schedule-III CORRIDOR- Prahladpura to Todi Mod (Jaipur Metro Phase-2 Project) Lot 1.0 40952340.0 40952340.0 7371421.2 48323761.2 Total (Schedule-A = Schedule-I + Schedule-II + Schedule-III) 73828326.0 13289098.68 87117424.68 Contract D2EDD-02:- Detailed Design Consultancy for Design of 25 kV Overhead Equipment (OHE) system for the elevated lines, Power Supply & SCADA for both Underground and Elevated lines including checking of Design of Receiving Substations and Design Validation of 2 corridors of DMRC Phase-IV Project and Jaipur Metro Phase-2 Project Schedule-I: CORRIDOR- Lajpat Nagar to Saket G Block (DMRC Phase-IV) Activity: I Activity No. Description Unit Quantity Unit rate(INR)(Without Taxes) Total Amount(INR)(Without Taxes) Total Tax(INR)(GST @18%) Total Amount(INR)(With Taxes i.e. GST@18%) (A) (B) (C = A * B) (D = C * 18%) (E = C + D) Activity: I-A Design of 25 kV Overhead Equipment (OHE) system for elevated line and Power Supply & SCADA for both Underground and Elevated lines and Design Validation. kM 8.38 429000.0 3595020.0 647103.6 4242123.6 Activity: I-B Checking the Design of Receiving Sub-Stations (RSS) and 220/132/110/66 kV Cabling including Design Validation. Per RSS 0.0 686400.0 0.0 0.0 0.0 Activity: I-C Simulation and EMI / EMC study for determination of traction equipment sizing, power requirement, voltage drop, current, rail voltage, contact wire temperature etc. kM 8.38 471900.0 3954522.0 711813.96 4666335.96 Sub-Total (Activity: I) 7549542.0 1358917.56 8908459.56 Activity: II Activity: II For attendance during construction (excluding attendance required for design review /clarifications etc.) Activity: II(A) Chief Project Manager Mandays 5.0 42900.0 214500.0 38610.0 253110.0 Activity: II(B) Design Engineers Mandays 5.0 30030.0 150150.0 27027.0 177177.0 Sub-Total (Activity: II) 364650.0 65637.0 430287.0 Total (Schedule-I = Activity: I + Activity: II) 7914192.0 1424554.56 9338746.56 Contract D2EDD-02:- Detailed Design Consultancy for Design of 25 kV Overhead Equipment (OHE) system for the elevated lines, Power Supply & SCADA for both Underground and Elevated lines including checking of Design of Receiving Substations and Design Validation of 2 corridors of DMRC Phase-IV Project and Jaipur Metro Phase-2 Project Schedule-II: CORRIDOR- Rithala-Narela-Kundli(DMRC Phase-IV) Activity: I Activity No. Description Unit Quantity Unit rate(INR)(Without Taxes) Total Amount(INR)(Without Taxes) Total Tax(INR)(GST @18%) Total Amount(INR)(With Taxes i.e. GST@18%) (A) (B) (C = A * B) (D = C * 18%) (E = C + D) Activity: I-A Design of 25 kV Overhead Equipment (OHE) system for elevated line and Power Supply & SCADA for both Underground and Elevated lines and Design Validation. kM 26.46 429000.0 11351340.0 2043241.2 13394581.2 Activity: I-B Checking the Design of Receiving Sub-Stations (RSS) and 220/132/110/66 kV Cabling including Design Validation. Per RSS 1.0 686400.0 686400.0 123552.0 809952.0 Activity: I-C Simulation and EMI / EMC study for determination of traction equipment sizing, power requirement, voltage drop, current, rail voltage, contact wire temperature etc. kM 26.46 471900.0 12486474.0 2247565.32 14734039.32 Sub-Total (Activity: I) 24524214.0 4414358.52 28938572.52 Activity: II Activity: II For attendance during construction (excluding attendance required for design review /clarifications etc.) Activity: II(A) Chief Project Manager Mandays 6.0 42900.0 257400.0 46332.0 303732.0 Activity: II(B) Design Engineers Mandays 6.0 30030.0 180180.0 32432.4 212612.4 Sub-Total (Activity: II) 437580.0 78764.4 516344.4 Total (Schedule-II = Activity: I + Activity: II) 24961794.0 4493122.92 29454916.92 Contract D2EDD-02:- Detailed Design Consultancy for Design of 25 kV Overhead Equipment (OHE) system for the elevated lines, Power Supply & SCADA for both Underground and Elevated lines including checking of Design of Receiving Substations and Design Validation of 2 corridors of DMRC Phase-IV Project and Jaipur Metro Phase-2 Project Schedule-III: CORRIDOR- Prahladpura to Todi Mod (Jaipur Metro Phase-2 Project) Activity: I Activity No. Description Unit Quantity Unit rate(INR)(Without Taxes) Total Amount(INR)(Without Taxes) Total Tax(INR)(GST @18%) Total Amount(INR)(With Taxes i.e. GST@18%) (A) (B) (C = A * B) (D = C * 18%) (E = C + D) Activity: I-A Design of 25 kV Overhead Equipment (OHE) system for elevated line and Power Supply & SCADA for both Underground and Elevated lines and Design Validation. kM 42.8 429000.0 18361200.0 3305016.0 21666216.0 Activity: I-B Checking the Design of Receiving Sub-Stations (RSS) and 220/132/110/66 kV Cabling including Design Validation. Per RSS 2.0 686400.0 1372800.0 247104.0 1619904.0 Activity: I-C Simulation and EMI / EMC study for determination of traction equipment sizing, power requirement, voltage drop, current, rail voltage, contact wire temperature etc. kM 42.8 471900.0 20197320.0 3635517.6 23832837.6 Sub-Total (Activity: I) 39931320.0 7187637.6 47118957.6 Activity: II Activity: II For attendance during construction (excluding attendance required for design review /clarifications etc.) Activity: II(A) Chief Project Manager Mandays 14.0 42900.0 600600.0 108108.0 708708.0 Activity: II(B) Design Engineers Mandays 14.0 30030.0 420420.0 75675.6 496095.6 Sub-Total (Activity: II) 1021020.0 183783.6 1204803.6 Total (Schedule-III = Activity: I + Activity: II) 40952340.0 7371421.2 48323761.2 Contract D2EDD-02:- Detailed Design Consultancy for Design of 25 kV Overhead Equipment (OHE) system for the elevated lines, Power Supply & SCADA for both Underground and Elevated lines including checking of Design of Receiving Substations and Design Validation of 2 corridors of DMRC Phase-IV Project and Jaipur Metro Phase-2 Project ANNEXURE 13APROFORMA FOR STATEMENT OF MINOR DEVIATIONS(Refer Clause C 2.2, C15.1 and C26.1 of ITT) The following are the particulars of minor deviations from the requirements of the Tender Document: Sr. No Clause Deviations Price adjustment for each deviation/s Note:1. The Tenderer shall indicate price adjustment against each deviation in Annexure 13A of BOQ. This price is the price which the tenderer shall reduce from this tender price if deviation(s) is/are accepted by the Employer.2. Where there is no deviation, please indicate ‘No Deviations’. In case, Performa of deviations is left as blank, it will be construed that the tenderer has not proposed any deviations from tender documents.3. If the tenderer proposes deviations in tender documents, and/or any other terms and conditions of the tender, other than in this Annexure, it will have no effect.4. All deviations have been listed and priced in the financial proposal and deviations not priced will be treated as null and void and stand withdrawn. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender