Tender For Proposed Mini Sports Arena In Plot Bearing Survey No.99/2 Belonging To Village Panchayat Of Reis Magos At Verem Reis Magos Saligao Constituency Bardez Goa
Tender Value
Ref. Documents
Estimated cost
Bid Submission
08 Aug 2026
17 days left
EMD
7.98 Lakhs
Bank guarantee accepted
Document Fee
15000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Proposed Mini Sports Arena In Plot Bearing Survey No.99/2 Belonging To Village Panchayat Of Reis Magos At Verem Reis Magos Saligao Constituency Bardez Goa
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL WORKS |
| 2 | Earthwork in excavation by mechanical means (hydraulic excavator)/ manual means in foundation/pipeline trenches drains (not exceeding 1.5 m in width or 10 sq.m. on plan) for all leads & lifts in all types of strata comprising of any type of material either in full or part as the case may be adapting any method/methods as may be convenient as permitted (excluding blasting) in all conditions such as dry, moist, foul etc. including dressing of sides, planking and strutting, timbering, ramming of bottom, pumping and bailing out water, barricading, danger lighting, guarding and carting away excess excavated earth at the site identified by the contractor and obtaining all statutory approvals, as directed by engineer for 50m lead and all lifts etc complete. |
| 3 | Earthwork in excavation over areas by mechanical/manual means in all type of strata upto a depth of 3 meters comprising any of the materials such as soil, silt, sand, clay, gravels, moorum of all varieties, shingles, pebbles, all types of conglomerates, all types of laterite rock, soft rock, disintegrated rock, fissured/ shattered/ decomposed rock or weathered rock and all such other materials as described under appendix to these specifications whether in full or in parts as the case may be adopting any approved method or methods as may be convenient or permitted inclusive of chiselling, wedging etc. in all conditions such as dry, moist, saturated, submerged, foul conditions etc.blasting prohibited including pumping or bailing out water including segregating the excavated earth/rock and disposal of surplus excavated earth at contractors identified site(at risk and cost of the contractor)for all leads and lifts and as directed by Engineer . |
| 4 | Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth outside the premises in the dumping ground aproved by the Corporation and as directed by Engineer in Charge. |
| 5 | Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete. |
| 6 | Pre-cast cement concrete solid block masonry of compressive strength 70 kg / cm2 in cement mortar 1:4 (1 cement : 4 coarse sand ) in foundation and plinth size of blocks (30 x 23 x 15) |
| 7 | Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size) excluding cost of centering, shuttering and finishing : All works upto plinth level |
| 8 | Providing and laying in position ready mixed concrete (RMC) with usage of Ordinary Portland Cement manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead upto 10kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C., from the transit mixer to the site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including the cost of admixtures in recommended porportions as per IS : 9103 to accelerate/retard setting of concrete, improve workability without imparing strength and durability as per the directions of the engineer-in-charge. All works upto floor V level (vi) M-25 grade of concrete |
| 9 | Centering & shuttering including Strutting, Propping & removal of forms for : (i) Foundations, Footings, Bases for columns |
| 10 | Centering & shuttering including Strutting, Propping & removal of forms for : (ii) Vertical surfaces such as retaing walls, return walls, Partitions, walls (any thickness) including attached Pilasters, Buttresses, Plinth and string courses, Fillets and the like |
| 11 | Providing TMT steel reinforcement bars of (SAIL, TATA. VIZAG, JSW Steel Ltd.) ) (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member. |
| 12 | 12mm cement plaster 1:3 (1 cement : 3 fine sand) |
| 13 | 12mm cement plaster 1:4 (1 cement : 4 fine sand) with 10 mm grove in plaster along the skirting, dado & door frames (Groove to be paid separately) |
| 14 | 6mm cement plaster to ceiling 1: 3 (1 cement : 3 fine sand) |
| 15 | 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge. |
| 16 | Kotah stone slab flooring over 25 mm thick in risers of steps, skirtings, dado & pillars laid on 12mm (average) thick cement mortor 1:3 (1 cement : 3 coarse sand) & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete. |
| 17 | Providing and fixing Kota stone tread tiles 35mm thick in single piece with rounded of nosing antiskid groove laid on and including 20mm (average ) thk bed of cement slurry including pointing with pigmented cement slurry to match the shade of the slab, cleaning etc. complete. |
| 18 | Providing and and laying vitrified full body profile decorative floor tiles in different sizes of Johnson, Somany, Kajaria (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make in colours and shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including grouting the joints with white cement and matching pigment etc., complete : d) 900 x 900 mm light Shades |
| 19 | Providing and laying factory made Shot blasted cement concrete interlocking paver block of minimum M35/M40 grade made by heavy duty block making machine with strong vibratory compaction and of aprpoved size and design / shape laid in 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand, etc. all complete as per the direction of Engineer.- in I, Wave, Rectangular, Square etc. shapes. The products should comply to IS 15658:2006 and manfucatured by ISO9001: 2008 certified plant. The shot blasting should be done using 0.4-0.5mm dia steel shots with a speed of 3200 rpm. (c) 80 mm thick in all colours except grey (M40 grade) |
| 20 | Painting three or more coats with acrylic exterior paint of approved brand and manufacture (Such as Dulex/ Asian Paints/ Sherwin Willians) including applying one coat of cement primer and one coat of surface treatment etc. complete. |
| 21 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc. With hairline finish, including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer, ( Including fixing accessories such as nuts, bolts, fasteners etc.). |
| 22 | Carraigeway and disposal of unserviceable building material, laterite stone, demolished concrete, excavated earth upto a lead of 20kms from site of execution by means of tipper truck including loading, unloading and dumping/ stacking as directed by Engineer -in- charge |
| 23 | Supplying and fixing of Precast RCC slabs(factory made,the factory should be ISO certified and registered under Dirctorate of Industries, Govt. of India) at site in concrete Grade of M-25 with 20 mm nominal size Granitic or basaltic aggregate, consolidated by means of mechanical platform, vibration etc. with lifting hooks of M.s. 10mm bars and PVC cups including cost of reincforcement, Certificate from manufacturer shall be produced indicating grade of concret and minimum content of steel in the product along with 5 year free replacement warranty in case of breakage complete and as directed by Engineer -in -charge. (a) Size 900 x 400 x 150 mm with steel reinforcement not less than 7 kg per unit -30 T capacity. |
| 24 | Supplying and fixing Pre-cast cement concrete kerb-stones(factory made, the factory should be ISO certified and registered under Directorate of Industries, Govt. of India) of M-20 with 20 mm nominal size granitic/basaltic aggregate properly consolidated by mechanical plat-form and vibrators with smooth finish including fixing at site complete as per specification : (a) Size 30 cm L x 50 cm H x 15 cm T |
| 25 | Granular Sub-base with Close Graded Material (Table:- 400-1) : By Mix in Place Method (Construction of granular subbase by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401) : for grading-III Material |
| 26 | Applying crusher stone dust (10mm thick) to areas over GSB compacted surface |
| 27 | Construction of subsurface drain with perforated pipe of 100 mm internal diameter of metal/ asbestos cement/ cement concrete/PVC, closely jointed, perforations ranging from 3 mm to 6 mm depending upon size of material surrounding the pipe, with 150 mm bedding below the pipe and 250 mm cushion above the pipe, cross section of excavation 400 x 550 mm. Excavated material to be utilised in roadway at site. |
| 28 | Gabian Structure for Retaining Earth (Providing and construction of a gabion structure for retaining earth with segments of wire crates of size 7 m x 3 m x 0.6 m each divided into 1.5 m compartments by cross netting or crate sizes as approved by the Engineer-In-Charge, made from 4 mm galvanized steel wire @ 32 kg per 10 sqm having minimum tensile strength of 300 Mpa conforming to IS:280 and galvanizing coating conforming to IS:4826, woven into mesh with double twist, mesh size not exceeding 100 x 100 mm, filled with boulders with least dimension of 200 mm, all loose ends to be tied with 4 mm galvanized steel wire) |
| 29 | Supply and Installation of Non-woven needle – punched geotextile fabric (PET or PP)1) Type: Non-woven needle-punched geotextile (Polyester (PET) or Polypropylene (PP)).2) Weight/Mass per Unit Area: minimum 270 g/m²3) Thickness: Minimum 2.3 mm or greater.4) Apparent Opening Size (AOS): Designed to retain soil particles (O95 value).5) Permeability: High cross-plane permeability, ensuring water passes freely to avoid hydrostatic pressure build-up.6) Mechanical Properties:a. Tensile Strength: > 10 – 20 KN/M (varies based on manufacturer, e.g., Tech Geo PR20/PR30: Needle-punched non-woven geotextiles manufactured by TechFab India Industries Ltd.b. Elongation at Break: Fairly high ( 40 % - 80%) to accommodate soil movementc. CBR Puncture Strength: High, to withstand damage during backfilling. CBR puncture strength shall be 2800 N or higher for high-survivability applications.d. Durability: Resistant to oxidation, UV radiation, and environmental biodegradation |
| 30 | Providing, mixing and placing of cementitious, non-shrink, free flow grout of Masterflow 718 (BASF) / CONBEXTRA GP2 or equivalent in base plate and bolt sleeves of all steel columns, with 28 days compressive strength not less than 60MPa including all formwork, curing etc. complete |
| 31 | Construction of artificial turf for futsal court with 5 years warranty with line marking as directed by Engineer Incharge having following Specifications:Production Process : Tufted cut pilePile Material : 100% PE + PP monofilamentYarn Dtex : 12.400Dtex / 16 plyQuality : 100% European product, free of heavy metals and toxicsPrimary Backing : 100% PP, UV stabilised , approx 160 gr./m2 : +/-10%Coating : SBR Latex, approx 800 gr./m2 : +/-10%Water Permeability : >300 ml per minute per 100 cm2Pile Height : Approx. 26mm : +/-10%Total Height of construction : Approx. 28mm : +/-10%Pile Weight : Approx. 1365 gr./m2 : +/-10%Total Weight of construction : Approx. 2325 gr./m2 : +/-10%Tuftgauge : 3/8' gaugeStitches per square metre : 160 : +/-10%Stitches per square metre : 16.800 : +/-10%Filaments per square metre : 537.6 : +/-10%UV Stability : 8 years of warranty Light Fastness : Blue scale 1-8 > 7 (according DIN 54004) Colourfastness : Gray scale 1-5 > 4 ( according DIN standards) Installation Method : Loose laid on bound or unbound sub base Infill : Silica sand, gradation 0.5- 1.0mm Sand type : Min. 80% round of shape Recommendation : Approx. 5kg per m2 for stabilisation Roll Width : 2 meters or 4 meters : +/-1%Roll Length : Target length approx. 25 linear meters. All data above are subject to modification based upon technical improvements or company internal developments. All figures are average values and can vary slightly. |
| 32 | Supplying and fixing HDPE / Polypropylene net in twisted, braided & knotless types soccer net conforming to British Standards BSEN748-2013 and BSEN8462-2005. Soccer nets in the standard colors of white, green and orange (single colored, bicolor or checkered) of Garwale make or equivalent HDPE UV treated Net twisted, 3 mm twin size & mesh of 50 mm X 50 mm on all four sides of court as per the directions of Engineer Incharge. |
| 33 | 8-layer Synthetic Acrylic Professional Sports Flooring System for an outdoor badminton court: Providing and laying 8-layer Synthetic Acrylic Professional Sports Flooring System for an outdoor badminton court, specifically designed for shock absorption and player safety, over a prepared M25 grade reinforced cement concrete (RCC) substrate. The system shall include the following successive layers applied in strict accordance with the manufacturer's technical specifications: Substrate Preparation & Primer: Cleaning the existing M25 concrete surface of all dust and debris, followed by the application of one coat of high-quality Acrylic Primer (1st layer) to ensure a high-strength bond between the concrete and synthetic layers.Resurfacer Coats: Application of two coats of Acrylic Resurfacer (2nd & 3rd layers) blended with fine silica sand to fill surface voids, smooth out the concrete subfloor, and provide a uniform foundation.Cushion System: Application of three layers of Rubberized Acrylic Cushion (4th, 5th, & 6th layers) composed of high-performance rubber granules/particles to provide dynamic shock absorption and reduce joint stress during high-intensity play.UV-Resistant Topcoats: Application of two coats of 100% pure Acrylic UV-Resistant Color Topcoat (7th & 8th layers) featuring anti-skid properties and high-pigment concentration to resist fading, weathering, and wear under harsh outdoor conditions.Line Marking: Precise marking of court lines as per Badminton World Federation (BWF) standard dimensions using specialized non-skid, high-contrast white acrylic paint |
| 34 | Providing and fixing 7 m height fencing with 2 m clearance behind the baseline and 1.5 m clearance from sidelines having technical specifications as given below:1.Structural Framework: Vertical posts (MS Pipes) 76mm OD (3 inch), 2mm thick, height 7m above ground level, powder-coated green/blue, with base plate connected to the pedestal of size (400x400x600mm) with hot dipped galvanized bolts of specified diameter complete as per drawings and specification. Yield Stress 240MPa (min) Fe 410W B (Hot Dip Galvanized To 75 Micron Zinc Coating), pedestal at 4m C/C. Horizontal runner pipes (MS Pipes) 60mm OD, 2mm thick, at top and bottom of the fence, powder-coated.Diagonal cross members ( MS pipes) 32 mm OD at the corner panelsAll steel components shall be factory-finished with PU paint or powder coating to prevent corrosion and covered with safety gaurd upto the height of 2.4m from the ground level 2.Fencing Mesh/Netting:Providing and fixing 2.5mm thick PE-coated galvanized steel chain-link fencing mesh (50mm x 50mm) or heavy-duty HDPE nylon net (high impact resistance).3.Fixtures & Installation:Providing 3mm thick extruded aluminum flats for fastening chain link mesh to MS frame with powder-coated finish and self-tapping screws.4) Fabrication of hinged gate for court entry (approx. 1m x 2m) using matching MS pipes and chain-link mesh. |
| 35 | Supply and installation of professional-grade outdoor badminton posts and net.Professional-grade outdoor badminton postsSupply and installation of professional-grade outdoor badminton posts 6.1 m apart. Posts to be made of 50mm diameter Class B, GI pipe with 200 mm x200 mm x 8 mm thick base plate with provision for heavy duty 4 nos of M16 or M20 foundation bolts , industrail grade UV resistant powder-coated, 1.55m clear height above ground ( concrete to be paid separately), post to include an integrated a brass or heavy-duty steel ratchet or pulley system to strain the net properly using a counterweight (minimum 50kg to 125kg per post) to ensure they remain vertical and taut when the net is strained. Posts should be fixed securely in the ground with weatherproof grout using HILTI or FISCHER Anchor bolts ( Badminton Post Approved make: Metco Sports, Vinex Enterprises, Royal Play Equipments, Edel International, Nagpal Engineering & Sports, Singhson Engineers) |
| 36 | Supply and installation of professional-grade outdoor badminton posts and net.UV treated Badminton Net ( Court width - Doubles)Supply and installation of UV-treated Nylon (dark color) Net with a mesh size between 15mm and 20mm and with 75mm wide white cloth top tape doubled over a cord or cable, conforming to BWF standards. Installation must ensure zero gap between net ends and posts, with a center height of 1.524m. ( Badminton Net Approved Make Vinex Enterprises (Meerut), G.N. Enterprises (Delhi), Ashok Hardware (Chennai), and Supreme Fishnet Industries. ) |
| 37 | Supply, fabrication, tensioning, and flawless installation of a high-performance overhead ceiling containment net over a futsal ground (minimum clear height of 7.5 to 12 meters). The scope includes premium UV-stabilized, high-density polyethylene (HDPE) or high-tenacity polypropylene (HTPP) knotted/knotless netting, heavy-duty perimeter and cross-tensioned galvanized steel wire ropes, turnbuckles, D-shackles, eye-bolts, drop-forged wire rope clips, and all necessary structural anchoring accessories. The work must be executed at all heights using proper scaffolding or boom lifts, including specialized labor, tools, tension adjustments, and safety compliance, complete as per the approved engineering designs and direction of the Engineer-in-Charge Netting Technical Specificationsa) Material options: High-Density Polyethylene (HDPE) or High-Tenacity Polypropylene (HTPP).b) Construction type: Knotted (high impact resistance) or Knotless (interwoven, reduces sagging).c) Mesh size: 40mm x 40mm to 50mm x 50mm (prevents futsal ball escape).d) Twine diameter: 2.5mm to 4.0mm braided construction.e) Breaking strength: Minimum 110 kg to 150 kg per single twine.f) UV stabilization: 3% to 5% Carbon Black or chemical UV inhibitors (UV-A & UV-B protection).g) Weathering resistance: Chemically inert, rot-proof, zero moisture absorption (for HDPE).h) Perimeter binding: 6mm to 8mm overlocked reinforcing border rope. Tensioning & Hardware Specificationsa) Wire ropes: 6mm to 8mm diameter, 7x19 strand construction, Hot-Dipped Galvanized Steel (Grade 1570/1770 N/mm²).b) Turnbuckles: M12 to M16 eye-and-eye or hook-and-eye type, drop-forged galvanized steel (DIN 1480).c) D-shackles: 8mm to 12mm pin diameter, high-tensile steel, screw pin type (unthreaded pins forbidden).d) Eye-bolts: M12 to M16 heavy-duty collared eye-bolts, anchored using chemical grout or mechanical expansion anchors.e) Wire rope clips: Drop-forged steel U-bolt grips (EN 13411-5), minimum 3 clips per dead-end termination.f) Carabiners / Rings: 6mm galvanized steel spring hooks spaced every 300mm to 500mm along perimeter cables |
| 38 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) with modular switch, modular plates, suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (f) Group C -- with Cat B Modular Accessories |
| 39 | Wiring for group controlled light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 40 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required. (b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm Conduit) |
| 41 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required. (c) 2 x 4 sq.mm + 1 x 4 sq.mm earthwire (20mm Conduit) |
| 42 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required. (j) 4 x 6 sq.mm + 2 x 6 sq.mm earthwire (32mm Conduit) |
| 43 | Supplying and fixing suitable size modular GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/ 6 A modular switch connection painting etc. as required. (b) Cat B |
| 44 | Supplying and fixing suitable size modular GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 15/16 A and 5/6 A modular socket outlet modular socket outlet and 15/16 A modular switch connection painting etc. as required. (b) Cat B |
| 45 | Supplying and fixing following way TPN sheet steel, double door, Horizontal type MCB distribution board 415 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator) (d) 8 way (8+24), double door, Horizontal type Cat A |
| 46 | Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. (j) TPN, Cat B |
| 47 | Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. (f) SP, Cat B |
| 48 | Supplying and fixing following rating double pole (single pole and neutral) 240 V RCCB having a sensitivity current upto 300mA in the existing MCB DB complete with connections testing and commissioning etc as required (e) 40 A, Cat B |
| 49 | Earthing with GI earth pipe 2 mts long 40 mm dia medium class with ISI mark,of approved brands, including accessories and providing masonry enclosure with CI/RCC cover having locking /lifting arrangement and watering pipe etc. with charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size 1.0x1.0x 2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe, 40mm diameter as per specifications. c) Charcoal/salt as per specs ( paid seperately). d) Refilling the pit of size 1.0x1.0x 2.0 mtrs(min) with soft black soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe. g)watering arrangement(plumbing will be paid seperately). (b) In rocky strata |
| 50 | Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosure with CI/RCC cover having locking/Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size 1.0x1.0x 3.0 mtrs(min) and disposal of excavated soil. c)Watering GI pipe, 20mm, Class B, with funnel as per specs. d) Charcoal/salt as per specs ( paid seperately). e) Refilling the pit of size 1.0x1.0x 3.0 mtrs(min) with soft black agriculture soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe.g)watering arrangement(plumbing will be paid seperately). (b) In rocky strata |
| 51 | Extra for using salt and charcoal for pipe earth electrode as required( 65 Kgs of Charcoal and 5 Kgs of Salt). |
| 52 | Supplying and laying 6 SWG GI wire at 0.5 m below ground level for conductor earth electrode including soldering etc. as required |
| 53 | Providing and fixing 6 SWG dia GI wire on surface or in recess for loop arthing . as required |
| 54 | Supplying and laying 25 mm x 5 mm GI strip at 0.5 m below ground as strip earth electrode including soldering etc. as required |
| 55 | Supply of 3 core unarmoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 3 Core 2.5 sq.mm |
| 56 | Supply of 4 core armoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 4 Core 6 sq.mm |
| 57 | Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. (3) 4 x 6 Sq. mm. |
| 58 | Supply of 4 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 4 Core 25 sq.mm |
| 59 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. (6) 4 x 25 Sq. mm. |
| 60 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required.(b) In rocky strata |
| 61 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm in the existing RCC/HUME/STONEWARE Metal pipe, etc. complete as required |
| 62 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface, etc. complete as required |
| 63 | Providing and laying non-pressure NP2 class (light duty) RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand ) including testing of joints, etc. complete. A) 100 mm dia RCC pipe |
| 64 | Supplying and fixing of following sizes of rigid PVC conduit alongwith accessories in surface(medium)/recess(heavy) including cutting the wall and making good the same in case of recessed conduit as required. (c) 32 mm |
| 65 | Supply and erecting of 48 inch (1200mm sweep) ceiling fan, double ball bearing type, , complete with all accessories. (b) Cat B |
| 66 | Supply and erecting fan hook box ( 100 mm diameter or equivalent square size, 75mm deep) fabricated out of 16 SWG sheet steel with 10 m round bar hook bounded to RCC steel upto 50 mm length protruding on each side of the box, including painting with 2 coats of red oxide, complete as required. |
| 67 | Supply and erecting of 12 inch (300 mm sweep) exhaust fan with double ball bearings, 1400 rpm, complete with all accessories. (a) Cat A |
| 68 | Supplying and erecting LED Linear Batten fitting (4 feet) Max. 20W with high transitivity diffuser with system lumens output of Min.2000 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<20%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs at L70B50 including driver with end caps. Make:-Wipro / Crompton / Nice / Havells / Reytek / Leksa / La Luminite as required and directed by engineer incharge. |
| 69 | Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete. Make:- Wipro / Crompton / Nice / Havells / Reytek / Leksa / La Luminite as required and directed by engineer incharge. |
| 70 | Supplying and erecting integrated LED flood light fitting Max. 200W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 20000 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs at L70B50 including driver with U shaped bracket. Make:- Wipro / Crompton / Nice / Havells / Reytek / Leksa / La Luminite as required and directed by engineer incharge. |
| 71 | Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation. Make:- Hakke / Transrail / RSR Ispat / Mechanize Engineering as required and directed by engineer incharge. |
| 72 | Providing & erecting 8 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 135 mm A/F, top 70 mm A/F on provided foundation. Make:- Hakke / Transrail / RSR Ispat / Mechanize Engineering as required and directed by engineer incharge. |
| 73 | Supplying and erecting Street light bracket made from 40 mm. dia ‘B’ class G.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads. Make:- Hakke / Transrail / RSR Ispat / Mechanize Engineering as required and directed by engineer incharge. |
| 74 | Supplying and erecting customised street light bracket for mounting of 2 Nos. flood lights on pole, fabricated from 40 mm dia ‘B’ Grade G.I. pipe of required length and shape, suitable for side entry type fittings, complete with necessary bends, clamps, base plate, nuts, bolts, welding, and anti-corrosive treatment. The bracket shall be specially designed to accommodate and support two floodlights with proper alignment and spacing for effective illumination. Make:- Hakke / Transrail / RSR Ispat / Mechanize Engineering as required and directed by engineer incharge. |
| 75 | Supplying and fixing 0.5 A to 5 A rating, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required\\" (f) SP, Cat B |
| 76 | Supply of 3 core unarmoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 3 Core 1.5 sq.mm |
| 77 | Supplying & erecting three phase, 415V, street light control panel upto the max load of 6kW, TPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54, IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation. Panel manufacturer having CPRI approval for similar panels as required and directed by engineer incharge. |
| 78 | Supply and erecting meter box suitable for three phase energy meter and incoming SP/DP MCB, fabricated out of 16 SWG sheet steel, powder coated, complete as required and conforming to the requirements of Goa Electricity Department. |
| 79 | Supply, installation, testing and commissioning of electronic type three phase energy meter (KWh), 4 wire, ISI marked, in polycarbonate or sgheet steel body ( base mounting type) with counter display/LCD display, with ELT, in Class 1.0, 50 Hz, 240 V. AC duly tested by MRT along with Test Certificates, complete as required of following capacity of make L & T only. (b) 10 to 40 A |
| 80 | Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50 cycles nominal cooling capacity of 40 litres per hour and storage capacity 80 litres with stainless steel body. Make:- Blue Star / Voltas / Eureka Forbes (Aquaguard) as required and directed by engineer incharge. |
| 81 | Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 11W capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230 V single phase AC supply with UV fail & filter change indication system. Make:- Eureka Forbes (Aquaguard) / Kent / Havells as required and directed by engineer incharge. |
| 82 | Supplying, erecting, testing and commissioning of minimum three & above star rated centrifugal water pump (monoblock), 230 V, single phase, 50 Hz, A.C. supply of 1.125 kW/1.5HP with discharge 198/50 lpm for head of 15/37.5 m & 40 mm suction/32 mm delivery pipe on provided CC foundation Make:- KBL / M&P / Grundfos / Crompton as required and directed by engineer incharge. |
| 83 | Supplying, erecting, testing and commissioning of automatic control panel for single phase, 230 V, A.C. supply centrifugal pump set upto 2 HP consisting of D.O.L. starter of suitable relay range, S.P.P., combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated vibration proof enclosure with IP54 protection, including required nos of sesors and wiring etc. Panel manufacturer having CPRI approval for similar panels as required and directed by engineer incharge. |
| 84 | Supply, installation, testing and commissioning of Main LT Panel, indoor type,wall mounted, fabricated from 14 SWG CRCA sheet steel for main structure and 16 SWG CRCA sheet steel for internal partitions, fully compartmentalised and suitable for 415V, 3 Phase, 4 Wire, 50 Hz AC supply, conforming to IS 8623 / IEC 61439. Panel shall have minimum IP42 protection, complete with hinged lockable doors with neoprene gaskets, removable gland plates for top/bottom cable entry and separate cable alley. Panel shall be provided with tinned Aluminium busbars with heat shrink sleeves supported on SMC/DMC insulators, MCCBs/MCBs, Digital Multifunction Meter (MFM), rotary operating handles with door interlock, CTs, self locking arrangement, FRLS control wiring, terminal blocks and cable termination hardware. Panel shall also include earthing busbar with earthing studs, lifting hooks, ventilation louvers with wire mesh, engraved feeder labels and powder coated finish of minimum 60–80 microns. Panel shall be complete with base frame, foundation bolts, internal wiring, interconnections, testing and commissioning as required. -SPD type 2 tested for Imax 15 kA for three phase and neutral-INCOMER: a) MCCB,4P, 63A, (Main Supply) b) Metering: LT 3-P Meter GED Approved c) MCCB,4P, 63A, (DG Supply) d) Metering: Digtal MFM-RYB Indicator: 3 Nos Main Supply, 3 Nos. DG Supply- ATS, 4P, 100AAccessories for automatic AMF operation of ATS relay/controller, auxiliary relays/contactors, control wiring and associated accessories complete as required for automatic source changeover operation.-BUS-BAR, Aluminium - 500V, 200A-OUT GOING: a) 32A, 4P MCB 10KA - 2No. c) 40A, 4P MCB 10KA - 3Nos. d) 6A, SP MCB 10KA - 27Nos. |
| 85 | Supply, installation, testing & commissioning of Diesel Generator Set 25kva @20 Kwe with Volvo Eicher engine, Canopy made of composite polymer-based material, Glass Reinforced Polymer (GRP) acoustic enclosure which can be recycled when replaced having Canopy Dimension of 2825x1090x1425mm (LxWxH) with total canopy weight not exceeding 900kg. Output continuous rating 3 ph, 415V, 50 hz 0.8 p.f A.C Supply. A totally enclosed water cooled 4-cylinder engine developing 38 BHP at 1500 RPM with 10% overload for 1hour in 12 hours. The Generator canopy shall be of non-metallic, non-rusting i.e. corrosion free, weatherproof, material suitable for coastal and high humidity conditions. The DG Set shall comply with CPCB IV+ noise norm with sound absorbing material to restrict sound level up to 75Db at 1.0m with the silencer positioned inside the canopy. The canopy shall maintain certified sound level for minimum of 15 years. The inbuilt tank fuel capacity at 85 litres & maximum fuel consumption 5.3 ltr / hr @ 75% loading. The Generator & Panel canopy material shall contain fire resistant, additives with self-extinguishing and non-conductive properties. the controller should be fixed in GRP panel box having metal hinges with SS finish should be welded from inside of box size of 650x450x200mm with box having powder coated in RAL9001 mounted at rear side at height of 954mm from ground level. The DG should come with low Vibration as per IS8528 part 9 & should be Aesthetically pleasing in colour combination of white & Anthracite grey for canopy with RAL9001 -RAL 7016 respectively with base frame size of 285mm made up of 2.5mm thickness in RAL 9005 maintaining 2 coat of Primer & 1 coat of Painting Process thickness 80microns. All the painting shall be done by qualified painters. Reference to CAT No- GRP PKGVEF-IV25 Paikane Make Or Equivalent as required and directed by engineer incharge. |
| 86 | Supply, Installation, Testing & Commissioning of 5MP IP IR Fixed Bullet Camera with minimum 5MP resolution, fixed lens, True WDR, IR illumination, H.265/H.264 compression, day/night functionality, PoE support, IP67 weatherproof housing and all required accessories, mounting hardware, interconnections and commissioning complete as required. Make: Honeywell / Bosch / Axis/ Samsung / Sony as required and directed by engineer incharge. |
| 87 | Supply, Installation, Testing & Commissioning of 16 Channel Network Video Recorder (NVR) supporting minimum 16 IP camera inputs, H.265/H.264 video compression, 4K recording and playback, HDMI/VGA output, minimum 4 SATA HDD support, network connectivity, USB ports, remote monitoring facility and all required accessories, cabling connections and commissioning complete as required. Make: Honeywell / Bosch / Axis/ Samsung / Sony as required and directed by engineer incharge. |
| 88 | Supply, Installation, Testing & Commissioning of 8TB Surveillance Hard Disk Drive suitable for continuous 24x7 operation in CCTV/NVR applications, optimized for video surveillance workload, SATA interface, high reliability performance and complete with all required accessories and connections as required. Make: Seagate / Toshiba/ WD-Purple as required and directed by engineer incharge. |
| 89 | Supply, Installation, Testing & Commissioning of 32” LED Monitor with Full HD resolution, HDMI/VGA connectivity, wide viewing angle, suitable for CCTV monitoring applications, complete with power cord, mounting accessories and all required connections as required. Make: Samsung / Sony / LG / Dell / Lenovo / HPas required and directed by engineer incharge. |
| 90 | Supply, Installation, Testing & Commissioning of 1000VA Line Interactive UPS with pure sine wave output, automatic voltage regulation, maintenance free battery, overload and short circuit protection, backup support for CCTV/network equipment and complete with all required accessories and connections as required. Make: Eaton / APC-Schneider / Legrand (Numeric) / Vertiv (Emerson) / Delta as required and directed by engineer incharge. |
| 91 | Supply, Installation, Testing & Commissioning of 6U Wall Mount Network Rack with powder coated enclosure, front glass door, ventilation arrangement, cable entry provisions, mounting hardware and all required accessories complete as required. Make: Valrack / ApwPresident / Rittal / APC / Cisco / Wipro / Vertiv as required and directed by engineer incharge. |
| 92 | Supplying and drawing of Cat - 6 UTP, 4 pair annealed tinned copper conductor PVC insulated, PVC sheathed, unarmoured data cable in existing surface/recessed steel/PVC conduit of appropriate size including connection, etc. complete as required (a) Cat 6 |
| 93 | Supplying and fixing of following sizes of rigid PVC conduit alongwith accessories in surface(medium)/recess(heavy) including cutting the wall and making good the same in case of recessed conduit as required.(b) 25 mm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysAug 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓