Educational and Research Institute Statutory Bodies & Commissions/Committees Closing in 3 days TDR #56574287

Tender For 1- Construction Of 3 Additional Class Room In Rajkiyakrit Upgrade High School Akna (20191403901) 2- Construction Of 4 Additional Claass Room In Rajkiyakrit High School Amba ( 20191400404)3- Construction Of 4 Additional Claass Room In Rajki

Issued by Statutory Bodies & Commissions/Committees · Jamtara, Jharkhand
Tender Value
2.49 Crore
Estimated cost
Bid Submission
27 Jul 2026
3 days left
EMD
4.99 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jamtara → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for 1- Construction Of 3 Additional Class Room In Rajkiyakrit Upgrade High School Akna (20191403901) 2- Construction Of 4 Additional Claass Room In Rajkiyakrit High School Amba ( 20191400404)3- Construction Of 4 Additional Claass Room In Rajkiyakrit Upgrade High School Kusbedia (20191121201) 4- Construction Of 4 Additional Claass Room In Rajkiyakrit Upgrade High School Bodhbandh (20191103901) In Jamtara District Of Santhal Pargana Division Of Jharkhand.

BOQ

Name of Work:- 1- Construction of 3 Additional Class Room in RAJKIYAKRIT UPGRADE HIGH SCHOOL AKNA (20191403901) 2- Construction of 4 Additional Claass Room in RAJKIYAKRIT HIGH SCHOOL AMBA ( 20191400404)3- Construction of 4 Additional Claass Room in RAJKIYAKRIT UPGRADE HIGH SCHOOL KUSBEDIA (20191121201) 4- Construction of 4 Additional Claass Room in RAJKIYAKRIT UPGRADE HIGH SCHOOL BODHBANDH (20191103901) in Jamtara District of Santhal Pargana Division of Jharkhand.
Sl. No. Item Description
11- Construction of 3 Additional Class Room in RAJKIYAKRIT UPGRADE HIGH SCHOOL AKNA (20191403901) 2- Construction of 4 Additional Claass Room in RAJKIYAKRIT HIGH SCHOOL AMBA ( 20191400404)3- Construction of 4 Additional Claass Room in RAJKIYAKRIT UPGRADE HIGH SCHOOL KUSBEDIA (20191121201) 4- Construction of 4 Additional Claass Room in RAJKIYAKRIT UPGRADE HIGH SCHOOL BODHBANDH (20191103901) in Jamtara District of Santhal Pargana Division of Jharkhand.
2Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth a obtained to a distance up to 50M including all lifts with leveling ramming the foundation trenches removing roots of trees shurbs all complete as per approved design and per building specification and direction of E/I.
3Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item - B)
4Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
5Providing coarse clean sand in filling in foundation trenches or plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts includng cost of all materials, Labour, rotalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume).
6Providing designation 75B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening maerials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
7Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:6) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
8Providing designation 112mm thick reinforcement designtion 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:4) in supertructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including cost of screening materials scaffoliding raking out joints to 15mm depth curing taxesand royalty ( but excluding theb cost of reinforcement) all complete as per building specification and direction of E/I.
9Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size)
10Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
11Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size)
12Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
13Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
14Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
15Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size).
16Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
17Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
18Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
19Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
20Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases
21Foundations, footings, bases of columns, etc. for mass concrete Weather shade, Chajjas, corbels etc., including edges
22Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I.
23Providing Toe steel reinforcement of 8mm dia to 32mm dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL & TATA STeel) 8mm
2412mm-25mm
25S/F M.S. grill made of 20 x 6mm M.S. flat as per approved design and drawing, properly fabricated with joints continous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction ofE/I. (Where materials is not supplied by the deptt.)
26Providing and fixing fan hooks of 16mm dia M.S. bar & 1 meter long, bent torequired size and shape, placed in position and fixed in the R.C.C.slab/beam at the time ofcasting all complete as per building specification and direction of E/I.
27Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering texes royalty all complete as per building specification and direction of E/I.
28Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
29Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
30Providing 6mm thick cement plaster (1:4) in ceiling with clean of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
31Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I.
32Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper scaffolding , curing and taxes all complete as per building specification and direction of E/I.
33Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specificatio).
34Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I.
35Providing 19mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
36Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20mm nominal size ) over 75mm bad by dry brick ballast 40mm nominal size well rammend and consolidated and grouted with fine sand including finishing the top smooth.
37Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars atevery third course of half brick masonry.
38Supplying,fitting and fixing M.S. 40X40X4mm IS2062 grade A M.S. angle, hoisting in steps, welded with 6mm dia and 75mm long M.S. rods, anchorage fixed in concrete steps at the time of casting, including taxes all complete as per direction of E/I.
39Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use ofchequered plate wherever required, all complete In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
40Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shadecomplete.
41Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
42Providing 25mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layers 19mm. Thick (1:2:4)with 12mm to 6mm. Size graded stone chips and top layer 6mm. Thicks (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I.
43Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with sea; ring conforming to IS:5382, leaving 10mm gap for thermal expansion, Single socketed pipes
44Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler - 110mm
45Bend - 110mm
46Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete 110 mm
47Supplying, fitting and fixing fully glazed steel door, window or ventilations of standard rolled 'Z' and mullion steel sections and size as per IS-1038 joints met and welded with 100X16X3mm M.S. lugs fixed in cement concrete (1:2:4) block 15X10X10cm, size including cost of oxidised iron fittings, with hinges, handle per steps, catch springs, 3mm thick plain glass panes with Aluminimum beads and inner frame fixed with lugs with 20mm long 6.3mm G.I. counter sunk machine screw and nuts and applying a coat of red lead paint carriage to work site hoisting and placing in position in all storys and taxes all complete as per building specification and direction of E/I.
48Carriage of materials Bricks Lead = 1 k+7 P(8km)
49Fly Ash Brick - 15km
50Sand lead = 10 km
51Stone chips lead = 22 km
52Stone metal lead = 22 km
53Local Sand lead = 3km
54Providing and fixing male ended 15mm dia brass bib cock of approved quality (Wt. not less than 350 gms.) with extra socket all compere as per specification and direction of E/I.
55Providing & fixing 15mm size pillar cock C.I. body brass spindle pillar cock of approved quality as per specification & direction of E/I.
56Providing and fixing brass/C.I. stop cock of approved quality all complete as per specification and direction of E/I. 15 mm dia
57Providing and fixing G.M. non return valve Horizontal/Vertical type of approved quality as per specification and direction of E/I. Horizontal - 25 mm dia
58Horizontal - 32 mm dia
59Making holes in walls for laying G.I. pipe and restoring the same after pipe laying as per specification and direction of E/I. 125 mm thick wall
60250 mm thick wall
61Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I. Mirror (300 x 450mm)
62C.P. brass tower rail
63C.P. brass soap container medium quality with screw and hinges etc.
64Supplying, fitting and fixing viterious white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. 'p' trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair or viterous white glazed earthenware footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less than exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I.580mm long - With 12.5 lit. low level PVC cistern
65Supplying, fitting and fixing 40mm highb viterous white glazed earthen E.W.C. with 'P' trap of parry hindustan or any other approved I.S.S. make including supplying and fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fitting with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stope cock of approved quality weight not less than 450 grams 15mm PVC alkathene pipe 45cm. long with brass coupling at both ends and white/black plastic soild state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming all complete as per specification and direction of E/I.With 'P' trap - 12.5 lit low level PVC Cistern
66Supplying, fitting and fixing flat back or angular, lipped front viterous white glazed earthen ware urinal of 'Hindustan \\"Parry\\" or any other approved I.S.S. make with 5 liters capacity C.I. automatic flushing cistern of reliance for any other I.S.S. approved make with all fittings with C.I. or R.S., brackets, standard size G.I. flush pipe with fitting clamps, 15mm, C.I. body brass spindle stop cock of approved quality weight not less than 400 grams, 15mm P.V.C./Alkthene pipe 450mm long with brass coupling at both ends and doing plumber joints including painting coat of red oxide cutting wall and floor making good the same etc. all complete as per specification and direction of E/I. (a)Flat back or Standing Cornar
67Supplying, fitting and fixing viterous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on pointed C.I. or R.S. brackets 32m C.I. brass waste 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grms. 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I.
68Supplying NP2 R.C.C. hume pipe with colour as work site as per direction of E/I.150mm dia
69Approved basic rates construction materials for preparation of schedule of rates only, (Material should conform to relevent B.I.S. specification). The rates are inclusive of all taxes, royalty, cess and carraige but exclusive of contractor's profit and overhead charges -Special type of C.P. Bath room fitting for V.I.P. buildings (JAL, Jaguar, Marc or equivalent mark)Angular Stopcock /2 way bib cock
70Telephonic shower flexible pipe
71Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 75 mm diameter
72110 mm diameter
73Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single tee without door - 75x75x75 mm
74Single tee without door - 110x110x110 mm
7575 mm bend
76110 mm bend
77Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 25 mm nominal outer dia Pipes
7832 mm nominal outer dia Pipes
79Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 15 mm nominal outer dia Pipes
8020 mm nominal outer dia Pipes
81Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, ISI : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank.
82Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
83Point wiring in PVC conduit, with modular type switch - Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size G.I. box etc. as required.
84Twin Control Point Wiring in PVC Conduit, with Modular type Switch: Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, 2 way modular type switch, modular plate, suitable size of GI box etc as required.
85Circuit/Sub-main wiring in PVC Conduit:- Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required. 2x1.5 Sqmm + 1x1.5 sqmm earth wire
862x2.5 Sqmm + 1x2.5 sqmm earth wire
87S/F Modular type switch socket - Supplying and fixing following modular switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required 5/6 amps, one way switch
883 pin 5/6 amps, socket outlet
89S/F Modular type electronic fan regulator:- Supplying and fixing stepped (two module) type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required.
90S/F light plug point with modular type accessories - Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc. as required . (For light plugs to be used in non residential buildings)
91S/F power plug point with modular type accessories:- Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc as required.
92S/F Ceiling Rose:- Supplying and fixing 2 pin ceiling rose on the existing junction box/ wooden block including connection etc as required.
93S/F Batten / Angle Holder:- Supplying and fixing batten / angle holder including connection etc as required.
94Supplying and fixing following way single pole neutral, sheet, MCB disrtibution board, 240 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 8 way, single door
95Supplying and fixing 6 amps to 32 amps rating, 240 volts, \\"B\\" series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as required. 6/32, single pole, \\"B\\" series
96S/F DP MCB Isolator - Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 amp
9763 amp
98G.I. Earth electrode with salt/charcoal - Earthing with G.I. earth pipe 4.5 mtr. Long, 40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required
99P/F G.I. lightning conductor finial - Providing and fixing of lightning conductor finial, made of 25mm dia 300mm long, G.I. tube, having single prong at top, with 85mm dia 3mm thick G.I. base plate including holes etc. complete as required.
100S/L 8 SWG copper wire in ground - Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth, including soldering etc. as required
101Supplying PVC/XLPE insulated PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor- 3.5 core, 50 sq.mm
102Supplying and fixing of 9/10 Watt LED Bulb
103Supplying and fixing LED Batten (20/22W)
104Supply and installation of Ceiling fan 48\\" (1200mm)
105Supply of 12\\" (300mm) metal exhaust fan
106Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth a obtained to a distance up to 50M including all lifts with leveling ramming the foundation trenches removing roots of trees shurbs all complete as per approved design and per building specification anddirection of E/I.
107Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item - B) 50% of excavated earth
108Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compactedvolume). 65% OF Excavated Qty.
109Providing coarse clean sand in filling in foundation trenches or plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts includng cost of all materials, Labour, rotalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compactedvolume).
110Providing designation 75B brick work inC.M. (1:6) in foundation and plinth with approved quality of clean coarse sand ofF.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening maerials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction ofE/I.
111Providing designation 75 B brick work inC.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
112Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
113Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size)
114Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
115Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
116Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement :1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
117Centering and shuttering including strutting, propping etc. and removal ofform for Foundations, footings, bases of columns,etc. for mass concrete
118Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings,balconies and access platform
119Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams,girders, bressumers and cantilevers
120Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers,Abutments, Posts and Struts
121Foundations, footings, bases of columns, etc. for mass concrete Weather shade, Chajjas, corbels etc., including edges
122Providing Toe steel reinforcement of 8mm dia to 32mm dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (TMT coil Fe 500) {Only Valid for TATA (TISCON) SAIL, JSPL, Electrosteel Steels ltd. Bokraro & Vizag(RINL)} 8 mm to 32 mm dia (TMT coil Fe 500) {Only Valid for TATA (TISCON) SAIL, JSPL, Electrosteel Steels ltd. Bokraro & Vizag(RINL)} 8# dia@ 15%
12310# dia@20%
12412#-25# dia @ 65%
125Providing and fixing fan hooks of 16mm diaM.S. bar & 1 meter long, bent torequired size and shape, placed in position and fixed in the R.C.C.slab/beam at the time ofcasting all complete as per buildingspecification and direction of E/I.
126Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering texes royalty all complete as per building specification and directionof E/I.
127Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and directionof E/I.
128Providing 6mm thick cement plaster (1:4) in ceiling with clean of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
129Providing two coat of oil bound distemper of approved shade and make over a primer coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding, washing floors and taxes all complete as per buildingspecification and direction of E/I.
130Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primerapplied @ 2.20 kg/ 10 sqm)
131Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surfaceto prepare thesurface even and smooth complete.
132S/F M.S. grill made of 20 x 6mm M.S. flat as per approved design and drawing, properly fabricated with joints continous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction ofE/I. (Wherematerials is not supplied by the deptt.)
133Supplying, fitting and fixing M.S. grill gate with M.S. grill made of 20X6mm M.S. flats or 16mm M.S. square bars fitted on 25X25X6mm M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawingspecification and direction of E/I.
134Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement Area shall be multiplied by the co-efficient as indicated in buildingspecificatio).
135Providing two coat of painting with ready mixed paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
136Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawingspecification and direction of E/I.
137Providing 250mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification anddirection of E/I.
138Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20mm nominal size ) over 75mm bad by dry brick ballast 40mm nominal size well rammend and consolidated and grouted with finesand including finishing the top smooth.
139Water proofing for Old and New Roof Slab : Providing and laying water proofing treatment on roof slab by applying two Component, factory designed ready to use, acrylic modified flexible material applied with brush, roller or spray for water proofing coating as per manufacturerspecifications with following steps :- (b)1st Coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application ,45 gsm oI Fibre glass cloth to lay when the first (d) Protection of treated surface with PCC :- The treated surface should be covered with 25mm/50mm PCC of M-20 grade(1:1.5:3) with proper slope (1:120) towards tlre rain outlets in alternate panels of 2 mlx2ml keeping 6mm gap between the panel joint.lntegral water proofing
140Covering of treated surface wrth PCC :- Providing 25 mm thick Cement Concrete M20 (1:1.5:3) maintaining slope in alternate 2 mt x 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and cleaned sand of F M 2.5 io 3 including screening,shuttering,and mixingcement concrete in mixer with admixture
141Providing and filling of 6mm thick Groove between 25mm PCC panels with Polysuplhide sealant (Poring Grade) as per drawing and techinical speicifcation anddirection of E/I.
142Providing and laying vitrified parking/Industrial tiles in different sizes (thickness to be specified by the manufacturer ) with water absorption less than 0.08% and confirming to IS 4457:2007 of approved make in all colours and shades laid on 20mm thick cement mortar 1:4 (1 cement : 4 course sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigment etc,complete.Size of tile300x300x10mm
143Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with sea; ring conforming to IS:5382, leaving 10mm gap for thermalexpansion, Single socketed pipes 110 mm Rain water pipe
144Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gapfor thermal expansion. Coupler - 110mm
145Bend - 110mm
146Shoe - 110
147Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and makinggood the wall etc. complete 110 mm
148Carriage of materials Bricks Lead = 1 k+7 P(8km)
149Sand lead = 10 km
150Stone chips lead = 22 km
151Stone metal lead = 22 km
152Local Sand lead = 3km
153Point wiring in PVC consuit, with piano type switch -Wiring for light point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size PVC/G.I. box etc. as required
154Twin Control Point Wiring in PVC Conduit, with Modular type Switch: Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, 2 way modular type switch, modular plate, suitable size of GI box etc asrequired.
155Circuit/Sub-main wiring in PVC Conduit:- Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required. 2x1.5 Sqmm + 1x1.5 sqmm earth wire
1562x2.5 Sqmm + 1x2.5 sqmm earth wire
1574x6 Sqmm + 2x6 sqmm earth wire (For 32 A IT Socket )
158S/F piano type switch/socket -Supplying and fixing following piano tyep switch/socket on the existing switch box/cover including connections etc. as required. 5/6 amps, one way switch
1593 pin 5/6 amps, socket outlet
160S/F Modular type electronic fan regulator:- Supplying and fixing stepped (two module) type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc asrequired.
161S/F power plug point with modular type accessories:- Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etcas required.
162S/F Ceiling Rose:- Supplying and fixing 2 pin ceiling rose on the existing junction box/ wooden block including connection etc as required.
163S/F Batten / Angle Holder:- Supplying and fixing batten / angle holderincluding connection etc as required.
164Supplying and fixing following way single pole neutral, sheet, MCB disrtibution board, 240 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 8 way, single door
165Supplying and fixing 6 amps to 32 amps rating, 240 volts, \\"B\\" series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections,testing and commossioning etc. as required. 6/32, single pole, \\"B\\" series
166S/F DP MCB Isolator -Supplying and fixing following rating, double pole, 240 volts, isolator inthe existing MCB DB complete with connections, testing and commissioning etc. as required 40 amp
16763 amp
168G.I. Earth electrode with salt/charcoal -Earthing with G.I. earth pipe 4.5 mtr. Long, 40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required
169P/F G.I. lightning conductor finial -Providing and fixing of lightning conductor finial, made of 25mm dia 300mm long, G.I. tube, having single prong at top, with 85mm dia 3mm thick G.I. base plate including holes etc. complete as required.
170S/L 8 SWG copper wire in ground -Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth, including soldering etc. as required
171Cable Laying of 1.1 KV & 11 KV :-MV cable laying upto 95 sq.mm. in ground -Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 35 sq.mm. but not exceeding 95 sq.mm. direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
172Providing and fixing of XLPE, Aluminium Armoured PVC Cableconfirming to IS IS7908 (Part-1) 1988 0f grade 1.1KV. Make:- Havells / Finolex / Polycab Supplying PVC/XLPE insulated PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor- 3.5 core, 50 sq.mm
173Supplying and fixing of 9/10 Watt LED Bulb
174Supplying and fixing LED Batten (20/22W)
175Supply of LED Street light (45/48W)
176Supply and installation of Ceiling fan 48\\" (1200mm)
177labour cess Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56574287
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 2.49 Crore
LAST DATE 27-07-2026
Authority
Authority Name Jharkhand Education Project Council
Work Description Tender for 1- Construction Of 3 Additional Class Room In Rajkiyakrit Upgrade High School Akna (20191403901) 2- Construction Of 4 Additional Claass Room In Rajkiyakrit High School Amba ( 20191400404)3- Construction Of 4 Additional Claass Room In Rajkiyakrit Upgrade High School Kusbedia (20191121201) 4- Construction Of 4 Additional Claass Room In Rajkiyakrit Upgrade High School Bodhbandh (20191103901) In Jamtara District Of Santhal Pargana Division Of Jharkhand.
Basic Detail
Tender No JEPC/CIV/03/2265/2026/2756
Bidding Type Tender
Location
City Jamtara
State Jharkhand
Key Dates
Publish Date 21 Jul 2026
Submission Date 27 Jul 2026
Open Date 28 Jul 2026
Finance
Tender Value 2.49 Crore
Tender Fee 10000
EMD 4.99 Lakhs
Exemption Not Available
Document List
29.pdf
BOQ_157285.xls
f959c459-c339-4340-9cc0-eef2269f55eb.html
Tendernotice_1 (17).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Jul 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.