Housing Urban and Rular Development Government Departments Closing in 18 days TDR #56574049

Tender For Upgradation Of Takarjala Chc To 50 Bedded Sub-Divisional Hospital, Sepahijala ,Tripura /Construction Of Hospital Building (G+3 Storied), Type Iii Quarters (G+2 Storied), Type Ii Quarters (G+2 Storied), Type I Quarters (G+2 Storied) /Sh. Bu

Issued by Government Departments · Sepahijala, Tripura
Tender Value
26.73 Crore
Estimated cost
Bid Submission
10 Aug 2026
18 days left
EMD
53.47 Lakhs
Bank guarantee accepted
Document Fee
20000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sepahijala → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Upgradation Of Takarjala Chc To 50 Bedded Sub-Divisional Hospital, Sepahijala ,Tripura /Construction Of Hospital Building (G+3 Storied), Type Iii Quarters (G+2 Storied), Type Ii Quarters (G+2 Storied), Type I Quarters (G+2 Storied) /Sh. Building Portion Including Internal Water Supply & Sanitary Installation, Sewage & Drainage Works, Internal Road, Boundary Wall, Retaining Wall Etc.

BOQ

Name of Work:- Upgradation of Takarjala CHC to 50 bedded Sub-Divisional Hospital, Sepahijala ,Tripura /Construction of Hospital building (G+3 storied), Type III Quarters (G+2 storied), Type II Quarters (G+2 storied), Type I Quarters (G+2 storied) /SH. Building portion including internal Water supply & Sanitary installation, Sewage & Drainage works, Internal Road, Boundary wall, Retaining wall etc.
Sl. No. Item Description
1SUB-HEAD : EARTH WORK
2Earth work in excavation by mechanical means (Hydraulic excavatorB14:B288) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.
3All kinds of soil
4Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
5All kinds of soil
6Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
7All kinds of soil
8Extra for additional lift of 1.5m or part thereof.
9All kinds of soil
10Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete.
11Supplying chemical emulsion in sealed containers including delivery as specified.
12Chlorpyriphos/Lindane emulsifiable concentrate of 20%
13Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment as per IS: 6313 (Part III)- Latest revision (excluding the cost of chemical emulsion):
14Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.
15With Chlorpyriphos/Lindane E.C. 20% with 1% concentration.
16Treatment of soil under plinth filling using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with sand filling:
17With Chlorpyriphos/Lindane E.C. 20% with 1% concentration.
18SUB-HEAD : CEMENT CONCRETE WORK
19Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level:
201:4:8 ( 1 Cement: 4 fine sand : 8 graded stone aggregate 40 mm nominal size)
211:2:4 ( 1 Cement: 2 fine sand : 4 graded stone aggregate 20 mm nominal size)
221:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size)
23Centering shuttering including struttings, propping etc. and removal of form work for:
24Foundations, footings, bases for columns.
25Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification
26Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 fine sand : 6 graded well burnt brick aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
27SUB-HEAD : RCC WORK
28Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level:
291:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)
30Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement-
311:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)
32Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies,shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-
331:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)
34Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with
351:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)
36Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
37Thermo-Mechanically Treated bars of grade Fe-500D or more
38Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
39Thermo-Mechanically Treated bars of grade Fe-500D or more
40Providing precast cement concrete Jali 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3(1cement : 3 fine sand) etc. complete, excluding the plastering of jambs, sills and soffits
4150 mm thick
42Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size).
43Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in vertical & horizontal fins, individually or forming box louvers, setting in cement mortar 1:2 (1 cement : 2 coarse sand), including the cost of required centering, shuttering but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size).
44Centering shuttering including struttings, propping etc. and removal of form work for:
45Foundations, footings, bases for columns etc. for mass concrete with timber plank
46Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. using shuttering ply
47Suspended floors, roofs, landings, balconies and access platform with 12 mm thick shuttering ply
48Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply
49Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering ply
50Stairs (excluding landings) except spiral-staircases with wooden plank
51Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards.
52Edges of slabs and breaks in floors and walls under 20 cm. wide
53Weather shade, Chajjas, corbels etc., including edges.
54Providing and laying in position design mix cement concrete of specified grade for reinforced cement concrete work including pumping of concrete to site of laying but excluding the cost of centring, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per the direction of Engineer-in-Charge.
55All works upto plinth level - Reinforced cement concrete grade M-25 using 418 kg of cement per cum
56All works upto Floor five level - Reinforced cement concrete grade M-25 using 418 kg of cement per cum
57Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four floors or part thereof.
58Expansion joint
59SUB-HEAD : BRICK WORK
60First class brick work in foundation and plinth including cost of all materials as required complete.
61In cement mortar 1:4 ( 1 cement : 4 fine sand ).
62In cement mortar 1:6 ( 1 cement : 6 fine sand ).
63First class brick work in superstructure above plinth level & upto floor-five level including cost of all materials as required complete.
64In cement mortar 1:6 ( 1 cement : 6 fine sand ).
65Half brick masonry work with first class bricks in foundation and plinth including cost of all materials as required complete.
66In cement mortar 1:4 ( 1 cement : 4 fine sand ).
67Half brick masonry with first class bricks in superstructure upto floor five level including cost of all materials as required complete:-
68In cement mortar 1:4 ( 1 cement : 4 fine sand ).
69Extra for providing & placing in position 2 nos 6mm dia MS bars at every 4th course of half brick masonry work including anchorage in joints of 75mm in each side in superstructure for all level including cost of all materials as required complete:-
70In cement mortar 1:4 ( 1 cement : 4 fine sand ).
71SUB-HEAD : CLADDING WORK
72Providing and fixing gang saw cut of approved thickness mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base of cement mortar 1:4 ( 1 cement : 4 fine sand ) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing , curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels:-
7314 mm thick Rajnagar Plain white marble/ Udaipur green marble/ Zebra black marble or equivalent duly approved:-
74Area of slab upto 0.50 sqm.
7514 mm thick Granite of any colour and shade duly approved:-
76Area of slab upto 0.50 sqm.
7718 mm thick Rajnagar Plain white marble/ Udaipur green marble/ Zebra black marble or equivalent duly approved:-
78Area of slab upto 0.50 sqm.
79Providing edge moulding to approved thickness marble stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete at all levels as required as per design approved by the Engineer-in-charge:-
8014 mm thick Granite work.
8118 mm thick Granite work.
82Providing and fixing stone slab with table rubbed, edges rounded and polished of size 75x50 cm deep and approved thickness fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth including rubbing, curing etc. complete at all levels as required (measurement should be of exposed finished work):-
83White Agaria Marble Stone of approved shade of 14 mm thick (75 x 50 cm).
84SUB-HEAD : WOOD & PVC WORK
85Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position :
86Local Teak wood
87Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for paneled or paneled and glazed shutters 25 to 40 mm thick.
88Local Teak Wood 16mm. Thick
89Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:-
9035 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
91Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.
92Fixed to openings /wooden frames with rawl plugs screws etc.
93Providing 40 × 5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30 × 10 × 15 cm 1:3:6 mix (1 cement : 3 fine sand : 6 graded stone aggregate 20mm nominal size)
94Providing and fixing hard drawn steel wire fabric 75 x 25 mm mesh of weight not less than 7.75 Kg per sqm to window frames etc. including 62 x 19 mm beading of Gamair wood.
95Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
96300 x 16 mm
97250 x 16 mm
98Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :
99300 x 10 mm
100250 x 10 mm
101Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
102125 mm
103100 mm
104Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.
105Single rubber stopper
106Providing and fixing bright finished 100mm mortice lock with 6 levers without pair of handles for aluminium door with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge.
107Providing and fixing factory made door frame (single rebate) made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 60mm width & 30mm thickness and shall be fixed to wall as per instructions of Engineer-In-Charge using 100x8 sheet metal CSK screws.
108Providing and fixing 28 mm thick door shutter made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 71mm width & 28mm thick as vertical & horizontal styles. Joints are made using solvent adhesive and GI ‘C sections (39mm x 19mm x 0.6mm thick) or M S pipe (40mm x 20mm ) stiffener frame insert & telescopic polymeric ‘L’ corners .The panel shall be filled with 3mm thick high - pressure compact laminate as per manufacturer’s specifications and directions of the Engineer-in-charge, cover moulding shall be provided for covering fixing screws and elegant look.( for W.C. bathroom door shutter).
109Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated)handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.
110Two track two panels sliding door made of (big series) frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 5.00 sqm)
111Providing 50 × 50 × 50 mm Gamair wood plugs including cutting brick work and fixing in cement mortar 1:3 (1 cement: 3 fine sand) and making good the walls etc.
112Providing and fixing IS : 3564 marked Aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. complete.
113Providing and fixing in position wall panelling at all heights with integral densified calcium silicate panels/tiles of size 595 x 595mm, having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity <0.043 W/m K as per ASTM 518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceiling channel section of size 50 x 32m fixed to the floor and soffit at 600mm centers using 12mm dia,50mm long wedge type expanded zinc alloy dash fastner with 10mm bolt. This same channel is then to be fixed in horiziontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. Glasswool of 50mm thickness is then to be inserted in the slots and finally calcium silicate non combustible panels/tiles are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate
114based compound and fiber joint tape roll 50mm wide (90 metre )roll and two coats of primer suitable for panelling as per manufacturer's specification as per direction of Engineer-in-Charge all complete.
115SUB-HEAD : STEEL WORK
116Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm at 100 mm centre to centre and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia. steel pulleys & with riveted bolts, nuts, locking arrangement, stoppers, handles, hold fast /anchor bolt including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required.
117Providing and fixing fan clamp type-I of 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs during laying including painting the exposed portion of loop, all as per standard design complete.
118Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. complete as required:-
119In grating, frames, guard bar, railing, brackets, gates and similar works, all complete.Base plate and other plates for purlins
120Providing structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as required.
121Providing and fixing M.S. round holding down bolts with nuts and wahser plates complete as per standard design.Holding down bolts for base plates (20 mm dia)
122Providing and fixing MS bolts including nuts and washers complete as per standard design:-
123Upto 300 mm length for all connections of runner and purlines (16 mm dia)
124Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
125SUB-HEAD : ALUMINIUM WORK & STRUCTURAL GLAZING
126Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up of gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawing and the direction of Engineer­in­charge. (Glazing and paneling and dash fasteners to be paid for separately) :-
127For fixed portion of approved quality:-Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15).
128For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing fittings wherever required including the cost of EPDM rubber / neoprene gasket required ( Fittings shall be paid for separately ):-
129Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15).
130Providing and fixing glazing of approved quality in aluminium doors, windows, ventilator, shutters and partition etc. with EPDM rubber / neoprene gasket etc. complete as per architectural drawing and the direction of Engineer-in-charge (Cost of snap beading shall be paid in basic item) :-
131With float glass panes of 8.0 mm thickness ( weight not less than 20.0 kg / sqm )
132With float glass panes of 4.0 mm thickness ( weight not less than 10.00 kg / sqm )
133With float glass panes of 5.5 mm thickness ( weight not less than 13.50 kg / sqm )
134Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embrossed on the body / plate with double spring mechanism and door weight upto 125 kg. for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece MS sheet outer box with slide plate etc. complete as per direction of the Engineer-in-charge:-
135With stainless steel cover plate minimum 1.25 mm thickness
136Providing and fixing stainless steel ( SS 304 grade ) adjustable friction window stay of approved quality with necessary stainless steel screws etc. to the side hung windows etc. complete as per direction of Engineer-in-charge:-
137255 x 19 mm
138205 x 19 mm
139Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. of approved quality complete as per direction of Engineer-in-charge:-
140Anodised aluminium of grade AC 15.
141Providing and fixing 100 mm brass locks (best make of approved quality) with 6 levers without pair of handles for aluminium doors including necessary cutting and making good etc. complete as per direction of Engineer-in-charge.
142Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of aluminium composite panel material of approved thickness and specification. The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.
143(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.\\"
144Aluminium Composite Panels of 4mm total thickness with Top coil – 0.50mm AA3003 / AA3105 / AA5005 Grade manufactured as per IS-737 1986, FR Grade Class B1 with 3mm Mineral Core with minimum 70-72% Inorganic content (Aluminium Hydroxide and Magnesium Hydroxide) 28-30% Organic content (LDPE) conforming to ASTM E-119-16,18 and EN 13501-1, class B1,and Bottom coil – 0.50mm AA3003 / AA3105 / AA5005 Grade, manufactured as per IS-737 1986 with minimum 25 microns lead free PVDF Coating conforming to AAMA2605 on top coil and Service coating on Back Coil (4 - 6 microns) having minimum panel weight of 7.5 Kg/m2
145Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt. The glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof.
14610 mm thick clear toughened glass
147SUB-HEAD : FLOORING AND SKIRTING WORK
148Providing and laying cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate) flooring finished with a floating coat of neat cement including cement slurry, rounding of edges and strips and cost of glass strips [40mm wide and 4 mm thick] etc. all complete as per direction of Engineer-in-charge.
14940 mm thick
150Providing and laying flamed finish Granite stone flooring with border in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 fine sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc for Granite stone flooring complete in treads of steps and risers using single length upto 2.00 metre. all complete as specified and as directed by the Engineer-in-Charge.
15114mm thick Granite stone Slab
152Extra for pre-finished nosing to treads of steps of Granite stone flooring
153Providing and fixing 1st class quality ceramic glazed wall tiles conforming to IS : 15622 - 2017 (thickness to be specified by the manufacturer) of approved make in all colours, shades of any size as approved by Engineer-in-charge in skirting, risers of steps and dados, laid over 12 mm thick bed of cement mortar 1 : 3 (1 cement : 3 fine sand) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade etc. all complete as per direction of the Engineer in-charge.
154600 mm X 300 mm in all shades and design
155Providing and laying 1st class quality ceramic floor tiles in different sizes (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 - 2017 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid over 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc. all complete as per direction of the Engineer in-charge.
156Anti-Skid TilesSize of tile 300 mm x 300 mm in all shade and designs
157Mat Finish TilesSize of tile 600 mm x 600 mm in all shade and designs 1st class quality ceramic floor Porcelain tiles
158Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 -2017, of approved make,in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etcall complete as per direction of the Engineer-in-charge..
159Double charged Stainfree Vitrified tiles (Glossy)Size of tile 1200 mm x 600 mm
160Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid)Size of tile 1200 mm x 600 mm
161Glazed Vitrified Tiles - Full Body (Glossy / Mat Finish/ Anti-Skid)Size of tile 1200 mm x 600 mm
162Providing and fixing Precast chequered cement concrete tiles 18 mm thick, laid in footpath & courtyard, on 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with neat cement slurry including rubbing and cleaning etc. all complete as per direction of Engineer-in-charge.
163In dark shade using ordinary cement
164Providing and fixing Kota stone in floors over 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with ordinary cement slurry including pointing with ordinary cement mixed with pigment of matching shade, including rubbing and polishing etc. all complete as per direction of Engineer-in-charge.
165Kota stone slab 25mm thick
166Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1 : 3 ( 1 cement : 3 fine sand ) and joined with ordinary cement slurry mixed with pigment to match the shade of slabs, including rubbing and polishing etc. all complete as per direction of Engineer-in-charge.
167Providing and fixing tactiles of standardized designs conforming to RNIB (The Royal National Institute for the Blind, UK), DETR (Department of the Environment, Transport and the Regions, UK) & ADA (Americans with Disabilities Act, USA) of size 300 x 300 mm in floors, (thickness to be specified by the manufacturer) specially designed to assist the visually impaired - “foot braille”, with water absorption less than 0.5%, of approved brand & manufacturer, laid on 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) including grouting of joints etc. all complete as per direction of Engineer-in-charge. (Payment for grouting of joints to be made separately)
168Providing and laying factory made chamfered edge Cement Concrete paver blocks of required strength, thickness & size/ shape, made by table vibratory method to attain superior smoothfinish using PU or equivalent moulds, laid in required grey colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks, lawns, drive ways or light traffic parking etc. all complete as per specifications & approval/ direction of the Engineer -in-Charge:.
16980 mm thick factory made c.c. interlocking paver block of M-35 with approved colour, design and pattern.
170Extra for providing and laying Vitrified tiles (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622 - 2017, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. all complete as per direction of the Engineer-in-charge
171Soluble Salt Stainfree vitrified tiles (Glossy) / Double charged Stainfree vitrified tiles (Glossy) / Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) / Glazed Vitrified Tiles - Full Body (Glossy / Mat Finish/ Anti-Skid)
172Providing and fixing Marble stone in floors over 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with ordinary cement slurry including pointing with white cement mixed with of matching shade, including rubbing and polishing complete.
17314mm thick Marble StoneRajnagar plain marble
174Tile work in skirting, risers of steps and dado up to 2 m height over 12 mm thick bed of cement mortar 1:3 (1 cement :3 fine sand) and jointed with grey cement slurry @ 3.3 kg/sqm, including pointing in white cement mixed with pigment of matching shade complete.
1758mm thick Rajnagar marble tiles (polished)
176SUB-HEAD : ROOFING AND CEILING WORK
177Supply & installation of pre-painted Galvalume sheets for roofing/cladding (size, shape and pitch of corrugation as approved by Engineer-in-charge) in 550mpa steel grade, made out of Cold Rolled Steel coated with Zinc-Aluminium alloy coating of 43.5% Zn, 55% Al and 1.5% Silicon confirming to ASTM A792/A792M and AS1397, Alloy coating AZ150/AZ70, colour coated with high quality Polyester coating, top coated of modified polyester of 20 micron, back side coat of 5 micron, having epoxy primer coat of 5 micron on both side. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required and as per direction of Engineer-in-charge.
1780.50mm thickness
179Supply & installation of pre-painted Galvalume sheets roofing accessories in 550mpa steel steel grade, made out of Cold rolled steel coated with Zinc-Aluminium alloy coating of 43.5% Zn, 55% Al and 1.5% Silicon confirming to AASTM A792/A792M and AS1397, Alloy coating AZ150/AZ70, colour coated with high quality polyester coating, top coated of modified polyester of 20 micron, back side coat of 5 micron, having epoxy primer coat of 5 micron on both side etc. complete as per direction of Engineer-in-charge. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation. The sheet shall be fixed using self drilling /self tapping screws with EPDM washers complete for Ridges/Valley/Gutter/Flashing of width 610mm:
1800.50mm thickness
181PProviding and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm
182and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings etc. complete and as per direction of Engineer-in-charge.
18312.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.
184Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kg/cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:
185Single socketed pipe - 110 mm OD
186Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type-A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:
187Coupler - 110 mm
188(ii) Single equal tee with door - 110 x 110 x 110 mm
189(iii) Single equal tee without door - 110 x 110 x 110 mm
190(iv) Bend 87.5o - 110mm
191(v) Plain shoe - 110 mm
192Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing with cement mortar 1 : 4 (1cement : 4 fine sand) making good the wall etc. complete.
193110mm
194Providing and fixing to the inlet mouth of rain water pipe PTMT grating with thickness of 8mm and weighing not less than 100gm. complete.
195100mm
196SUB-HEAD : FINISHING WORK
19712 mm cement plaster of mix:-
198In cement mortar 1 : 4 ( 1 cement : 4 fine sand )
199In cement mortar 1 : 6 ( 1 cement : 6 fine sand )
20015 mm cement plaster on the rough side of single or half brick wall of mix:-
201In cement mortar 1 : 6 ( 1 cement : 6 fine sand )
2026 mm cement plaster of mix:-
203In cement mortar 1 : 3 ( 1 cement : 3 fine sand )
204Neat cement punning.
205Wall painting with acrylic plastic emulsion paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :
206Two or more coats on new work
207Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade[Pavement shall be made after submission of Test Certificate issued by the manufacture
208New work (Two or more coats) over and including water thinnable priming coat with cement primer.
209Finishing walls with premium acrylic smooth exterior paint with Silicon additives of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :
210New work ( two or more coats applied @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
211Applying priming coat [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :
212With ready mixed Pink or Grey primer of approved brand and manufacture on wood work ( hard & soft wood ).
213With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
214Painting with synthetic enamel paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:
215Two or more coats on new work
216Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
217SUB-HEAD:WATER PROOFING WORK
218Grading roof for water proofing treatment complete as required as per direction of the Engineer-in-charge with :
219Cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate 20 mm nominal size)
220Cement mortar 1:4 (1cement : 4 fine sand)
221Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound, as directed by Engineer-in-Charge and consisting of applying :
222(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.
223(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
224SUB-HEAD : PLUMBING WORKS
225Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :
226White Vitreous china Orrisa pattern W.C. pan of size 580x440 mm with integral type foot rests.
227Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :
228W.C. pan with ISI marked white solid plastic seat and lid
229Providing and Fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
230Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern.
231Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe.
232Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively.
233Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings:
234Flat back wash basin of size 550x400mm.
235Providing and fixing kitchen sink including making all connections excluding cost of fittings.
236White glazed fire clay sink of size 600x450x250mm.
237Providing and fixing white vitreous china laboratory sink including making all connections excluding cost of fittings:
238Size 600x450x200 mm.
239Providing and fixing Stainless steel AISI 304 (18/8) kitchen sink as per IS 13983 with C.I brackets and stainless steel plug 40 mm including painting of fittings and brackets cutting and making good the wall wherever required:
240Kitchen sink without drain board610X460 MM bowl depth 200 mm
241Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
242(i) Semi rigid pipe - 32 mm dia
243(ii) Flexible pipe - 32 mm dia
244Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
245Providing and fixing 600x120x5mm glass shelf with edges round of supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
246Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour.
247450mm long towel rail with total length of 495mm, 78mm wide and effective height of 88mm, weighing not less than 170gms.
248Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colours weighing not less than 105 gms.
249Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements weighing not less than 106 gms.
250Providing and fixing on wall face unplasticised Rigid PVC rain water, soil, waste & vent pipes (working pressure 6 kg / cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:
251Single socketed pipe - 110 mm OD
252Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC soil, waste pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:
253Coupler110mm
254Single pushfit Coupler110 mm
255Single equal tee with door110 x 110 x 110 mm
256Single equal tee without door110 x 110 x 110 mm
257Double equal junction of required degree without door110x110x110 x110 mm
258Double equal junction of required degree with door110x110x110 x110 mm
259Bend 87.5 degree110mm
260Plain shoe110 mm
261Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water, soil, waste & vent pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing with cement mortar 1 : 4 (1cement : 4 fine sand) making good the wall etc. complete.
262110mm
263Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size ) including necessary plaster and pointing in cement mortar 1:4(1cement: 4 coarse sand):
264100 mm dia.
265Providing and fixing SS grabbars set for accessible toilets comprising of 4 No. Grabbars as specified:(1 NO. wing grabbar + 1 NO. Lshaped grabbar + 2 No. straight grabbars= 1 typical set)a) Swing grabbar (1 NO) Providing a S.S.304 SWING HANDICAP GRABBAR-700mm and of DIA:32MM and thickness 1.5 mm of the roved brand and make.b) L shaped grabbar (1 NO) Providing S.S304 LSHAPED DISABLED GRABBAR of SIZE-600MM (H)X600MM(D) and 32MM DIA and thickness 1.5mm of the approved brand and make.c) Straight grabbar (2 NO) Providing S.S.304 GRAB RAIL (600 MM), 32MM DIA and thickness 1.5mm of the approved brand and make.
266SUB-HEAD : WATER SUPPLY
267Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
268Internal work - Exposed on wall
26915 mm nominal outer dia .Pipes.
27020 mm nominal outer dia .Pipes.
27125 mm nominal outer dia .Pipes.
27232 mm nominal outer dia .Pipes.
27340 mm nominal outer dia .Pipes.
27450 mm nominal outer dia .Pipes.
275Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
276Concealed work including cutting chases and making good the walls etc.
27715 mm nominal outer dia .Pipes.
27820 mm nominal outer dia .Pipes.
27925 mm nominal outer dia .Pipes.
28032 mm nominal outer dia .Pipes.
281Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge.
282External work
28315 mm nominal outer dia .Pipes.
28420 mm nominal outer dia .Pipes.
28525 mm nominal outer dia .Pipes.
28632 mm nominal outer dia .Pipes.
28740 mm nominal outer dia .Pipes.
28850 mm nominal outer dia .Pipes.
289Providing and fixing brass bib cock of approved quality :
29015 mm nominal bore
291Providing and fixing brass stop cock of approved quality :
29215 mm dia nominal bore
293Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end):
29425 mm nominal bore
29540 mm nominal bore
296Providing and fixing gun metal non-return valve of approved quality (screwed end):
29725 mm nominal boreVertical
29840 mm nominal boreVertical
299Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
300Constructing masonry Chamber 30x30x50 cm, inside , in brick work in cement mortar 1:4 (1 cement :4 fine sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement :5 fine sand:10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design :
301With Second Class bricks
302Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:
303100 mm diameter
304Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements weighing not less than 106 gms.
305SUB-HEAD : SEWAGE AND DRAINAGE WOPRKS
306Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the of 1:1 (1 cement: 1 fine sand) including testing of joints etc. complete :
307150 mm diameter
308Providing and laying cement concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) alround S.W. pipes including bed concrete as per standard design:
309150 mm diameter S.W, pipe
310Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with well burnt 2nd class bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
311Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 1st class bricks in cement mortar 1:4 (1 cement : 4 fine sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 fine sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 fine sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :
312Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets :
313Inside dimensions 600x850 mm and 45 cm deep for pipe line with one or two inlets :
314Extra for depth beyond 450 mm of brick masonry chamber for underground C.I. inspection chamber with same specification as mentioned in item no 20.330 complete as per standard design :
315For 500x700 mm size
316For 600x850 mm size
317Supplying and installation of 2 H.P Mono block Pump 50x40 mm Suction and delivery pipe complete fabricated to C.0 base of standard size with holding down bolt with panel board, single phase connection motor and starter to main switch, indicator and earthening etc. complete as per direction of the Engineer-In-Charge (No additional cost for electrification upto main switch will be paid seperately) Measurement to be taken after successful operation of the Pump)
318SUB-HEAD : ROAD WORKS
319Providing & laying filter media with jhama brick aggregate as per specification to a thickness of not less than 600 mm with smaller size towards the soil & bigger size towards the wall & providing over the entire surface behind abutment , wing wall, return wall to the full height, compacted to firm to condition complete as per drawing and MoRD technical specification clause 1204.3.8.
320Providing weepholes in brick masonry/stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe or PVC pipe (110 mm OD of 6.0 kg/cm^2 pressure) extending through the full width of the structures with slope of 1 (V):20 (H) towards drawing face complete as per drawing and MoRD technical specification clauses 614,709,1204.3.7.
321Compacting Original Ground Compacting Original Ground supporting subgrade
322Loosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per MoRD Technical Specification Clause 303.5.2.
323GRANULAR SUB-BASES, BASES (NON-BITUMINOUS) AND SHOULDERS
324Granular Sub-base with Well Graded Material (Table 400.1)By Mix in Place Method
325Construction of granular sub-base by providing well graded material spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per MoRD Technical Specification Clause 401.For Grading I Material
326Water Bound Macadam Sub-Base / Base
327WBM Grading - 2
328Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/ binding materials to fill up the interstices of coarse aggregate, watering and compacting to the required density 'Grading 2' as per MoRD Technical Specification Clause 405.By Mechanical Means
329Water Bound Macadam Sub-Base / Base
330WBM Grading 3
331Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill up the interstices of coarse aggregate, watering and compacting to the required density 'Grading 3' as per MoRD Technical Specification Clause 405.By Mechanical Means
332BASES AND SURFACE COURSES (BITUMINOUS)
333Tack coat using hot straight run bitumen of grade VG-30 on W.B.M.
334Providing and applying tack coat using hot straight run bitumen of grade VG-30, including heating the bitumen, spraying the bitumen, cleaning and preparing the existing road surface as per specifications: On W.B.M. @ 0.75 kg/ sqm.
33525 mm thick Open-Graded Premix Carpet using Bituminous (Viscosity grade/ modified bitumen) Binder
336Providing, laying and rolling of open-graded premix carpet of 25 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using Viscosity grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80 - 100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C or Type D as per MoRD Technical Specification Clause 508.
337Case - II By Mechanical MeansBitumen of VG-30
338Seal Coat
339Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A or Type B or Type C or Type D as per MoRD Technical Specification Clause 510.
340A By Manual MeansCase-IV : Type D (premix with fine sand)(i) Bitumen of VG-30
3412425290.0
3423453073.0
343110111190.0
34419396532.0
345412846.0
3465523107.0
3472073872.0
3488636330.0
34922129106.0
350885670.0
3519093116.0
3521037905.0
3531928080.0
3541371126.0
355746925.0
3563320901.0
3574709777.0
358135958282.0
35926327789.0
360553202.0
3618706505.0
3622618923.0
36311401524.0
36426264900.0
3651056330.0
36611920306.0
3671340617.0
3682653349.0
3692337954.0
3701029777.0 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56574049
AUTHORITY Government Departments
TENDER VALUE 26.73 Crore
LAST DATE 10-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for Upgradation Of Takarjala Chc To 50 Bedded Sub-Divisional Hospital, Sepahijala ,Tripura /Construction Of Hospital Building (G+3 Storied), Type Iii Quarters (G+2 Storied), Type Ii Quarters (G+2 Storied), Type I Quarters (G+2 Storied) /Sh. Building Portion Including Internal Water Supply & Sanitary Installation, Sewage & Drainage Works, Internal Road, Boundary Wall, Retaining Wall Etc.
Basic Detail
Tender No 01/EE-BRG/PWD/2026-27
Bidding Type Tender
Location
City Sepahijala
State Tripura
Key Dates
Publish Date 20 Jul 2026
Submission Date 10 Aug 2026
Open Date 10 Aug 2026
Finance
Tender Value 26.73 Crore
Tender Fee 20000
EMD 53.47 Lakhs
Exemption Not Available
Document List
Annexure.pdf
Appendix.pdf
BOQ_76175.xls
DNIet.pdf
eb3366e5-2e66-4d4a-9815-e978f9cb6ee3.html
Tendernotice_1 (17).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Aug 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
pdf

Annexure.pdf

pdf

Appendix.pdf

xls

BOQ_76175.xls

pdf

DNIet.pdf

html

eb3366e5-2e66-4d4a-9815-e978f9cb6ee3.html

pdf

Tendernotice_1 (17).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders