Power Boards / Undertakings / PSU Closing in 16 days TDR #56573759

Tender For Replacement Of Temporary Quarter With Permanent Quarter At Rangit Nagar Colony

Issued by Boards / Undertakings / PSU · West District, Sikkim
Tender Value
3.18 Crore
Estimated cost
Bid Submission
10 Aug 2026
16 days left
EMD
6.40 Lakhs
Bank guarantee accepted
Document Fee
1770
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
West District → Sikkim
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Replacement Of Temporary Quarter With Permanent Quarter At Rangit Nagar Colony

BOQ

Name of Work:- Replacement of temporary quarter with permanent quarter at Rangit Nagar Colony
Sl. No. Item Description
1Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
2Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 50mtrs and earth filling inthe depression/pit.)Girth from 300 mm to 600 mm
3Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 50mtrs and earth filling in the depression/pit.)Girth from 600 mm to 900 mm.
4Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
5Excavation work by mechanical means (Hydraulic Excavator)/ manual means infoundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m. Ordinary rock
6Excavation work by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m. Hard rock (blasting prohibited)
7Extra for every additional lift of 1.5 m or part thereof in (Ordinary or hard rock).
8Filling with available excavated earth in trenches, plinth and side of foundation in building works with layers not exceeding 20cm in depth including consolidation of each layer by ramming, watering etc, all complete.
9Sand filling in building works in layer not exceeding 20cum including watering,ramming etc, all complete.
10Providing and Laying in position cement concrete of specified grade including compacting curing etc all complete.1:2:4 mix. (1 cement, 2 coarse sand, 4 graded stone aggregate of 20mm & down size)
11Providing and Laying in position cement concrete of specified grade including compacting curing etc all complete.1:3:6 mix. (1 cement, 3 coarse sand, 6 stone aggregate of 20mm & down size)
12Providing and laying in position machine batched and machine mixed design mix M‐25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer‐in‐charge.(Note :‐ Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).
13Extra for providing richer mixes at all floor levels.Note:‐ Excess/less cement over the specified cement content used is payable / recoverable separately.Providing M‐30gradeconcreteinsteadofM‐25 grade BMC/ RMC. (Note:‐ Cement content considered in M‐30 is @ 340 kg/cum)
14Supplying, bending and placing in position tor steel reinforcement in allR.C.C works including cost of binding wires, all complete.
15Providing, fixing & removing form work for casting R.C.C items as indicated below: with locally available timber)Beam, lintels, girders, brersumers and c antilevers.
16Providing, fixing & removing form work for casting R.C.C items as indicated below: with locally available timber)Foundation, footings, base of column et c for mass concrete.
17Providing, fixing & removing form work for casting R.C.C items as indicated below: with locally available timber)Floor slab, roof slab, landing, balcony a nd access platform.
18Providing, fixing & removing form work for casting R.C.C items as indicatedbelow: with locally available timber)Square columns
19Providing and Laying damp proof coarse 40 mm thick with cement concrete 1:2:4 ( 1 cement, 2 Clean coarse sand, 4 graded stone aggregate 12.5 mm & nominal size) as per the direction of Engineer in Charge.
20Providing and Laying first class brick masonry in one and half brick thick wall in superstructure with 1:6 cement mortar (1 cement, 6 clean coarse sand) as per the direction of Eng.-in- charge including curing etc. all complete.
21Providing and laying first class brick work in half brick thick in superstructure of standard size bricks with 1:4 cement mortar (1 cement and 4 course sand) including carriage of bricks up towork site, curing etc all complete.
22Providing and Laying 12mm thick cement plaster of specified mix in singlecoat including finishing even and smooth and curing complete.1:4 (1 cement: 4 fine sand).
23Providing and Laying 15mm thick cement plaster of specified mix in single coat including finishing even and smooth and curing etc all complete.External Surface inner side : 1:4 (1 cement: 4 finesand).
24Providing and Laying 20mm thick cement plaster of specified mix in single coat including finishing even and smooth and curing etc all complete. 1:6 (1cement: 6 fine sand).
25Providing and laying plaster of paris putty of 2mm thick over lastered surface to prepare the surface even and smooth all complete:
26Providing and painting with plastic Emulsion paints two or more coats on New surface of required shade to give an even shade including brushing the surface clean of all dirt dust and smoothenedby sand paper etc complete.
27Providing and painting with acrylic exterior paints of quality and make equivalent to EXCEL, WEATHER SHIELD to give an even shade including brushing the surface clean of dirt, dust etc and sand papering andfilling the scratches complete on New surface.
28Providing and painting on G.S. sheet one or more coats with ready mixed paint to give an even shade including cleaning of surfaceof dust etc complete on new surface.
29Providing & applying priming coat with ready mixed Red oxide, Zinc chromate primer on steel/galvanized‐ Iron steel works i/c preparation of thesurface complete.
30Providing fitting fixing Fibre Glass reinforced plastic door frames of cross section 90 x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. . The laminate shall be moulded with fire retardant grade unsaturated polyester resin and chopped Mat. Doorframe laminate shall be 2 mm thick and shall be fitted with suitable wooden blocks in all the three legs. The frame shall be covered with fibre glass from all sides. MS stay shall be provided at the bottom to steady the frame.
31Providing, fitting and fixing of dressed local timber (tooni, katus equivalent) in all types of frames complete. With locally available timber
32Providing fitting fixing Fibre Glass reinforced Polyester (FRP) Windows Shutter of cross section 75 mm x 30 mm. The laminate shall be moulded with fire retardant grade unsaturated polyester resin and chopped Mat. Window shutter laminate shall be 2 mm thick and shall be fitted withsuitable wooden blocks.
33Providing fitting fixing Fibre Glass reinforced polyester (FRP) Window frames of cross section 90 x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. . The laminate shall be moulded with fire retardant grade unsaturated polyester resin and chopped Mat. Door frame laminate shall be 2 mm thick and shall be fitted withsuitable wooden blocks.
34Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
35Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
36Providing and fixing M.S grills in timber frames of windows with M.S flats with nuts, bolts, and smooth finishing of welded joints/surface with Grills weighing 8.00Kg/sqm as per the direction of Engineer ‐ in‐ Charge allcomplete
37Providing fitting and fixing water proof flush doors shutters, solid block hard core construction with frame of 1st class hard timber, with well matched 3mm commercial ply (both faces)including hinges with screws complete.30mm
38Providing and fixing to existing door shutter 30 mm thick Glass Fibre Reinforced Polyester (FRP) paneled door shutter of required colour and approved brand and manufacture, made with fire-retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden blocks of seasoned wood inside at required placed for fixing and fittings, cast monolitically with 5 mm thick FRP laminate for panels confirming to TADS 6: 1993 and / or IS 14856-2000 including fixing to frames.
39Providing and fixing Brass bright finished brass butt hinges withnecessary screws etc. complete.150x31x4mm.
40Providing and fixing Brass bright finished brass butt hinges withnecessary screws etc. complete. 125x31x4mm.
41Providing, fitting and fixing. sliding door bolts with nuts andscrews etc. complete.Size 300x16mm : Brass (bright Finish)
42Providing, fitting and fixing. sliding door bolts with nuts andscrews etc. complete.250x16mm Size : Brass (Bright Finish)
43Providing and fixing tower bolts 300x10mm (Barrel type) withnecessary screws etc complete : Brass (Bright Finish)
44Providing and fixing tower bolts 250x10mm (Barrel type) withnecessary screws etc complete. : Brass (Bright Finish).
45Providing, fitting and fixing. handles 125mm size with necessaryscrews etc complete. : Brass (Bright Finish).
46Providing, fitting and fixing. handles 100mm size with necessaryscrews etc complete. : Brass (Bright Finish).
47Providing and fixing 100mm mortise lock with 6 levers and pair of handleswith necessary screws etc complete. : Brass (B.F)
48Providing and Laying of 18mm thick 30 cm height cement plaster skirting with cement mortar 1:3 (1cement,3coarse sand) finished with a floating coat of neat cement including rounding of junctions and curing complete.
49Providing and Laying 40 mm thick 1:2:4 c.c. (1cement, 2coarse sand,4 of 12.5mm and down stone aggregate) flooring with floating coat of neat cement to give a smooth surface in not exceeding 02 sqm. including cost of glass strips and curing etccomplete in all building floors wherever specified.
50Providing and Laying. 25mm thick kota stone slab flooring over 20mm thick 1:4 cm base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including cutting, rubbing andpolishing complete.
51Providing and Laying kota stone slabs 25mm thick in Risers of steps, skirting dado and walls laid on 12mm thick (average) thick base of c.m. 1:3 (1 cement, 3 coarse sand) and jointed with grey cement slurry mixed with pigments to match the shade of the slab including cutting, rubbing andpolishing complete.
52Providing and fixing hand rail of approved size by welding etc. to steelladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.
53Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.: With 12 mm mild steel U beading
54Providing and fixing Mild steel residential gate fixing with nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.
55Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
56Structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat ofapproved steel primer all complete.
57Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
58Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes.
59Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 530x410 mm with integral type foot rests
60Providing, fitting and fixing. white vitreous white china wash flat back basin with CI brackets, painted, 15mm CP brass pillar taps, CP brass chain with rubber plug, 32mm CP brass waste pipe, lead or PVC connection 32mm dia CP brass cap and unions, complete including cutting and making good the wallswherever required. HINDWAREOne wash basin with one pillar cock. :45 cm x 30 cm
61P/F stain less steel kitchen sink with CI brackets, CP brass chain with rubber plug 40mm CP brass waste, CP brass tap etc complete i/c the fittings, cuttings and making good the wall wherever required. :610 x 450 x 200 mm.
62Providing and fitting chromium plated toilet paper holder including the making holes and fixed to timber cleats with CP screws washer etc. allcomplete:.
63Providing, fitting and fixing Beveled gauge mirror of superior glass with 6mm A.C. sheets ground and fixed to timber cleats with CP screws,washer etc complete.
64Providing, fitting and fixing. of chromium plated soap dish with necessaryscrew etc all complete.
65Providing, fitting and fixing towel rail of chromium plated brass completewith brackets fixed to the timber cleats, CP brass screws complete. : 600 x 20 mm
66Providing, fitting and fixing towel ring of chromium plated brasscomplete with CP brass screw and timber cleats.
67Providing and fixing M.S. or oxidized M.S. Hook and Eyes withcomplete set. : 150mm
68Providing, Fitting and fixing PVC 32mm dia pipe complete with GI fittings and clamps including cuttings and making good the walls etc. on wallfor wash basin connector to main line
69Providing, fitting and fixing soil, waste and vent pipes including testing etc complete.100 mm dia. PRINCE / SUPREME or equivalent soil pipe
70Providing, fitting and fixing. bends of various types plain or a band with access door, insertion rubber washer 3mm thick bolts and nuts complete SCI or centrifugally cost spun sands pipes.100 mm dia. Supreme / Prince
71Providing, fitting and fixing double equal junction of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.100 x 100 x 100 x 100 mm Supreme / Prince
72Providing and fixing 8mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and makeas approved by Engineer-in-charge.
73Providing, Fitting and fixing GI pipe of medium class, (excluding trenching, refilling, compacting and the cost of fittings) allcomplete.15 mm dia G I pipe
74Providing, Fitting and fixing GI pipe of medium class, (excluding trenching, refilling, compacting and the cost of fittings) all complete.20mm dia G I pipe
75Providing, Fitting and fixing GI pipe of medium class, (excluding trenching, refilling, compacting and the cost of fittings) all complete.25mm dia G I pipe
76Providing, Fitting and fixing GI pipe of medium class, (excluding trenching, refilling, compacting and the cost of fittings) all complete.32mm dia G I pipe
77Providing, Fitting and fixing GI pipe of medium class, (excluding trenching, refilling, compacting and the cost of fittings) allcomplete.40 mm dia G I pipe
78Providing, Fitting and fixing GI pipe of medium class, (excluding trenching, refilling, compacting and the cost of fittings) allcomplete.50 mm dia G I pipe
79Providing, Fitting and fixing Chromium plated fittings of approved quality and size complete: (ESCO ORIGINAL)BIB COCK 15 MM DIA
80Providing, Fitting and fixing Chromium plated fittings of approved quality and sizecomplete: (ESCO ORIGINAL)STOP COCK 15 MM DIA (CONCEALED WORKS)
81Providing, Fitting and fixing Chromium plated fittings of approved quality and sizecomplete: (ESCO ORIGINAL)ANGULAR STOP COCK 15 MM DIA
82Providing, Fitting and fixing Chromium plated fittings of approved quality and size complete: (ESCO ORIGINAL)BIBCOCK LONG BODY 15 MM DIA
83Providing, Fitting and fixing Chromium plated fittings of approved quality and size complete: (ESCO ORIGINAL)BIB COCK 15 MM DIA CONNECTING PIPE
84Providing and placing on terrace high density polyethylene water storage tank with man hole lid and suitable locking arrangement including making holes for inlet, out let and ball cock including testing etc. all complete: (Sintex or equivalent)1000 LITERS CAPACITY
85Providing, Fitting and fixing ball valve (Brass) of approved quality completewith high or low pressure with plastic floats:
86Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self‐priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer‐in‐Charge. (Contech/Perma/Zydex/Chryso)
87Providing and fixing brass ferrule with C.I. mouth cover including boring andtapping the main : 20 mm nominal bore.
88Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour: 20mm nominal bore. Weighing not less than40gms.
89Providing and fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) : 25 mm nominal bore.
90Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.
91Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality: L D- 2.5 - Rectangular shape600x450mm internal dimensions
92Providing and fixing square-mouth S.W. gully trap class SP1 complete withC.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 100x100 mm size P type - With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.
93Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement :1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets - With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.
94Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia.R.C.C. pipe.
95Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 100 mm diameter S.W.pipe.
96Loading and unloading of stone boulder/stone/aggregates/sand/ kanker/moorum.
97Loading and Unloading of Cement or Steel by Manual Means and stacking.
98Cost of haulage excluding loading and unloading- Surfaced road:-Non-stock & stock materials
99Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm HR-FRLSH insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc. as required. Group-A
100Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm HR-FRLSH insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc. as required. Group-B
101Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm HR-FRLSH insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc. as required. Group-C
102Wiring for circuit/ submain wiring along with earth wire with the following sizes of HR-FRLSH insulated copper single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
103Wiring for circuit/ submain wiring along with earth wire with the following sizes of HR-FRLSH insulated copper single core cable in surface/ recessed medium class PVC conduit as required 2 X 4.0 sq. mm + 1 X 4.0 sq. mm earth wire
104Wiring for circuit/ submain wiring along with earth wire with the following sizes of HR-FRLSH insulated copper single core cable in surface/ recessed medium class PVC conduit as required2 X 6.0 sq. mm + 1 X 6.0 sq. mm earth wire
105Wiring for circuit/ submain wiring along with earth wire with the following sizes of HR-FRLSH insulated copper single core cable in surface/ recessed medium class PVC conduit as required 2 X 10.0 sq. mm + 1 X 10.0 sq. mm earth wire
106Installation, testing and commissioning of pre-wired, fluorescent fitting of all types, with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm HR-FRLSH insulated, copper conductor, single core cable and earthing etc. as required.
107Supply & Fixing of 250 Volt, 4 Ft. long 2100lm 18 Watt Single LED Tube Light fittings complete with all accessories incl. LED Tube.Flicker free, high efficiency and robust industrial batten family suitable for surface, wall and conduit mounting.
108Power Consumption 9 W, Correlated Color Temperature (Nom) 6500 K, Luminous Flux 1000 lm, Luminous Efficacy (rated) (Nom) 110 lm/W Color rendering index (CRI) >80, Ingress protection code IP20 [Finger-protected], Mech. impact protection code IK02 [0.2 J standard], Surge Protection (Common/Differential) Surge protection level until 2.5 kV, Protection class IEC Safety class I - LED LUMINARIES.
109Power Consumption 10 W, Correlated Color Temperature (Nom) 6500 K, Luminous Flux 1000 lm, Luminous Efficacy (rated) (Nom) 110 lm/W Color rendering index (CRI) >80, Ingress protection code IP20 [Finger-protected], Mech. impact protection code IK02 [0.2 J standard], Surge Protection (Common/Differential) Surge protection level until 2.5 kV, Protection class IEC
110Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30cm) with 1.5 sqmm HR-FRLS insulated copper conductor, single core cable etc.
111Supply of 1200mm sweep ceiling fan suitable for operation on 230V, 50 Hz AC supply, complete with down rod, rubber shackle, blades, condensor, canopies etc. complete as reauired but without regulator.
112Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (Two module)
113Installation, testing and commissioning of Exhaust fan, including wiring with 1.5 sqmm HR-FRLSH insulated copper conductor, single core cable etc.
114Supply of single phase, 250 mm sweep, 1400 rpm exhaust fan suitable for operation on 230V, 50 Hz AC supply, complete with blades, condensor, frame etc. as required.
115Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc.
116Extra for fixing the louvers / shutters complete with frame for exhaust fan.
117Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
118Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
119Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 5/6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
120Supplying, fixing, testing & commissioning of following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required.1/2 Module (75mm X 75mm)
121Supplying, fixing, testing & commissioning of following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mm X 75mm)
122Supplying, fixing, testing & commissioning of following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required.4 Module (125mm X 75mm)
123Supply & earthing with G.I earth pipe 4.5 metre long, 40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coak and salt as required.
124Providing and fixing earth bus of 25 mm X 5 mm GI strip on surface for connections etc. as required.
125Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/ cable as required.
126Supply, fixing, testing and commissioning of integral flood (bracket light) fitting complete with 60 watt LED luminaries along with required Driver.Power Consumption 60 W, Correlated Color Temperature (Nom) 5700 K, Luminous Flux 8400 lm, Luminous Efficacy (rated) (Nom) 140 lm/W Color rendering index (CRI) >70, Luminaire light beam spread 130° x 88°, Optic type outdoor Distribution Symmetric Wide, Mounting device - Spigot for diameter 60 to 76 mm, IP66 [Dust penetration-protected, jet-proof], Mech. impact protection code IK10 [20 J vandal-resistant], Surge Protection (Common/Differential) 4/4 kV, Protection class IEC Safety class I
127Supply, erection, testing & commissioning of 6 mtr long Octagonal Pole, (200X200)x12 mm thick base plate, complete with 1 Mtr long single arm bracket. Pole is comprising with pole box arrangement consisting with 1 no 6A DP MCB 'C' curve of 10kA rated and pole earthing provision in the base plate and complete.
128Supply and connection of (2x1.5+1x1.5) sqmm HR-FRLSH type flexible copper conductor for internal connection of luminaries from Pole box (junction Box inside the pole) to luminaris.
129Supply of 1.1 kV grade, XLPE insulated, armoured, PVC outer sheath aluminium cable of following sizes.4 C X16 sq mm
130Laying of one number XLPE power cable of 1.1 KV grade of following size direct in ground but excluding sand cushioning and protective covering Upto 35 sq mm
131Laying of one number XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required.Upto 35 sq mm
132Providing, laying following outer dia HDPE pipe of PE 100 grade, SDR - 17, PN - 8 in ground as required40 mm dia
133Laying of following size cable in the existing masonary duct as requiredUpto 35 sq mm
134Laying and fixing of one number XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
135Laying and fixing of one number XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
136Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm
137Supply and fixing of the following ways prewired TP&N MCB distribution board of sheet steel for 415 volts, on surface/ recess complete with loose wire box, terminal connectors for all incoming and out going circuits, duly prewired with suitable size HR-FRLSH insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB / RCCB/ Isolator)4 way (4 + 12), Double door
138Supply and fixing of 5A to 32A rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
139Supply and fixing of 5A to 32A rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.: Double pole Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56573759
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 3.18 Crore
LAST DATE 10-08-2026
Authority
Authority Name National Hydroelectric Power Corporation Limited
Work Description Tender for Replacement Of Temporary Quarter With Permanent Quarter At Rangit Nagar Colony
Basic Detail
Tender No NH-RPS-CTS011(11)/4/2024-CIVIL TS/62
Bidding Type Tender
Location
City West District
State Sikkim
Key Dates
Publish Date 20 Jul 2026
Submission Date 10 Aug 2026
Open Date 19 Aug 2026
Finance
Tender Value 3.18 Crore
Tender Fee 1770
EMD 6.40 Lakhs
Exemption Not Available
Document List
BOQ_964836.xls
c8536ffe-9668-4faa-ad7b-83cd17dfdfa8.html
TD.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Aug 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 25 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_964836.xls

html

c8536ffe-9668-4faa-ad7b-83cd17dfdfa8.html

pdf

TD.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders