Tender For Renovation Of Garage Room In Gte Lab In Ced
Tender Value
5.24 Lakhs
Estimated cost
Bid Submission
10 Aug 2026
18 days left
EMD
10500
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kozhikode → Kerala
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Renovation Of Garage Room In Gte Lab In Ced
BOQ
| Sl. No. | Item Description |
| 1 | EARTH WORK |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc.in layers not exceeding 20cm in depth, consolidating each deposited layers by ramming and watering any lead and any lift including conveying the earth anywhere in the campus. |
| 3 | CEMENT CONCRETE (CAST IN SITU) |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 5 | 1:3:6 (1 Cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | 1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 7 | REINFORCED CEMENT CONCRETE |
| 8 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: |
| 9 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 11 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 12 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 13 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 14 | MASONRY WORK |
| 15 | Providing and laying factory made precast cement concrete solid blocks of grade M10 from approved manufacturer |
| 16 | For superstructure above plinth level up to floor two level, including all cost of materials, labour charges etc. |
| 17 | using blocks of 200mm thickness, in cement mortar 1:6 (1 cement : 6 coarse sand) |
| 18 | using blocks of 150mm thickness, in cement mortar 1:6 (1 cement : 6 coarse sand) |
| 19 | STONE WORK |
| 20 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : |
| 21 | Cement mortar 1:6(1 cement :6 coarse sand) |
| 22 | WOOD AND P. V. C. WORK |
| 23 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 24 | Fixed to steel windows by welding |
| 25 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 26 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 27 | 200x10 mm |
| 28 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 29 | Single rubber stopper |
| 30 | Providing and fixing bright finished C P Steel Aldrop with necessary screws etc. complete : |
| 31 | 300x16x5 mm |
| 32 | STEEL WORK |
| 33 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 34 | GI Tubular TATA or equvalent |
| 35 | FLOORING |
| 36 | Providing and laying Vitrified tiles in diferent sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). |
| 37 | Size of Tile 600x600 mm |
| 38 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. |
| 39 | Size of Tile 600x600 mm |
| 40 | Providing and laying Vitrified tiles in floor with diferent sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). |
| 41 | Size of Tile 600x600 mm |
| 42 | ROOFING |
| 43 | Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, difusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 44 | 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) |
| 45 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like difusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. |
| 46 | 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. |
| 47 | FINISHING |
| 48 | 12 mm cement plaster of mix: |
| 49 | 1:4(1 cement: 4 fine sand) |
| 50 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 51 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 52 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. |
| 53 | On steel work |
| 54 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 55 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. |
| 56 | Two coats |
| 57 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 58 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 59 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 60 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 61 | One or more coats on old work |
| 62 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 63 | Old work (Two or more coat applied @ 1.67 Itr/ 10 sqm) on existing cement paint surface |
| 64 | Melamine polishing on wood work (one or more coat). |
| 65 | REPAIRS TO BUILDING |
| 66 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 67 | With cement mortar 1:4 (1 cement : 4 fine sand) |
| 68 | Dismantling and Demolishing |
| 69 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars anywhere in the campus and disposal of unserviceable material outside the campus as per direction of Engineer - in- charge. |
| 70 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 71 | In cement mortar |
| 72 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : |
| 73 | In cement mortar |
| 74 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : |
| 75 | Of area 3 sq. metres and below |
| 76 | Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge. |
| 77 | Dismantling rolling steel shutter manually/ by mechanical means without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge. |
| 78 | SANITARY INSTALLATIONS |
| 79 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : |
| 80 | Size 600x450x200 mm |
| 81 | WATER SUPPLY |
| 82 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. |
| 83 | 15 mm nominal bore |
| 84 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 85 | 15 mm nominal bore |
| 86 | Providing and fixing Unplasticized Polyvinyl Chloride (UPVC) pipes of 10kgf/cm2 pressure rating for domestic water supply, conforming to IS:4985 including all UPVC plain & brass threaded fittings(as per IS:7834/IS:10124), including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with solvent cement and testing of joints complete as per direction of Engineer in Charge. Exposed on wall |
| 87 | 25mm nominal dia pipes |
| 88 | 32mm nominal dia pipes |
| 89 | 63mm nominal dia pipes |
| 90 | Providing and fixing Unplasticized Polyvinyl Chloride (UPVC) pipes of 15kgf/cm2 pressure rating for domestic water supply, conforming to IS:4985 including all UPVC plain & brass threaded fittings(as per IS:7834/IS:10124), including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with solvent cement and testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls, etc. |
| 91 | 25mm nominal dia pipes |
| 92 | Providing and fixing Unplasticized Polyvinyl Chloride (UPVC) pipes of specified pressure rating for domestic water supply, conforming to IS:4985 including all UPVC plain & brass threaded fittings(as per IS:7834/IS:10124). This includes jointing of pipes & fittings with solvent cement, testing of joints, trenching, refilling, complete as per direction of Engineer in Charge. External work |
| 93 | 10kgf/cm2 Pressure rating |
| 94 | 25mm nominal dia pipes |
| 95 | 32mm nominal dia pipes |
| 96 | 63mm nominal dia pipes |
| 97 | 110mm nominal dia pipes |
| 98 | ALUMINIUM WORK |
| 99 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 100 | For fixed portion |
| 101 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 102 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 103 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 104 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 105 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 106 | Providing and fixing 4mm thick Aluminium Partition Panels, in panelling fixed in aluminum door/window shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. |
| 107 | 4 mm thick aluminium partion panels |
| 108 | Providing and fixing sun control film on glass including cost and conveyance of all materials and labour charges etc. complete. |
| 109 | Sun Control film of approved colour/shade |
| 110 | Providing and fixing Aluminium Composite Panel (ACP) of 4mm or nearest thick, both side finished, in panelling fixed in aluminium door/window shutters and partition frames with CP brass/stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. |
| 111 | NEW TECHNOLOGIES AND MATERIALS |
| 112 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge |
| 113 | 25 mm average thickness Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysAug 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender