Housing Urban and Rular Development Government Departments Closing in 9 days TDR #56572988

Tender For Supply Installation Testing and Commissioning of Coventional Lightning Arrester At Isl Ur Sd Hospital,Isl Ur, Uttar Dinajpur.

Issued by Government Departments · Darjeeling, West Bengal
Tender Value
7.77 Lakhs
Estimated cost
Bid Submission
31 Jul 2026
9 days left
EMD
15551
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Darjeeling → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply Installation Testing and Commissioning of Coventional Lightning Arrester At Isl Ur Sd Hospital,Isl Ur, Uttar Dinajpur.

BOQ

Name of Work:- SITC of Coventional Lightning Arrester at Isl ur SD Hospital,Isl ur, Uttar Dinajpur.
Sl. No. Item Description
1Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
2Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) .
3Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
4Providing and fixing testing joint, made of 20 mm X 3mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
5Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
6Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
7Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done byoverlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
8Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
9Toward Charges for pressure testing ,vaccuminzing ,testing & commissioning with repair leak of 6 body mortuary unit.(throughly check 4nos of machines) as per EIC
10Supply & Filling of Refrigerant Gas R-404 for Mortuary Cooler as per EIC
11Replacement of old compressor by a new Compressor of 2.5 Ton Capacity .(Make :Bluestar) as per EIC
12LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K 46 DELHI SCHEDULE OF RATES (E&M)-2025 (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.
13Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
1418- 22 Watt Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56572988
AUTHORITY Government Departments
TENDER VALUE 7.77 Lakhs
LAST DATE 31-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for Supply Installation Testing and Commissioning of Coventional Lightning Arrester At Isl Ur Sd Hospital,Isl Ur, Uttar Dinajpur.
Basic Detail
Tender No WBPWD/EE/DED/e-NIT-34 of 2026-27
Bidding Type Tender
Location
City Darjeeling
State West Bengal
Key Dates
Publish Date 21 Jul 2026
Submission Date 31 Jul 2026
Open Date 03 Aug 2026
Finance
Tender Value 7.77 Lakhs
Tender Fee Ref. Documents
EMD 15551
Exemption Not Available
Document List
BOQ_5087052.xls
f3d909f4-45d0-446b-a09e-9cda3cc1b9f3.html
Tendernotice_1 (16).pdf
WBF2911.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Aug 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_5087052.xls

html

f3d909f4-45d0-446b-a09e-9cda3cc1b9f3.html

pdf

Tendernotice_1 (16).pdf

pdf

WBF2911.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders