Tender For Repair/ Maintenance Of Storm Water Drains, Damaged Broken Roof Sheet, Floor Tiles & Kota Stone, Ac Sheet, Joineries, Roof Treatment, Att, Sunken Floor, Saintary Fittings, Welcome Maintenance Of Various Md Accn, Painting Of External Service
Tender Overview
Project Description
Tender for Repair/ Maintenance Of Storm Water Drains, Damaged Broken Roof Sheet, Floor Tiles & Kota Stone, Ac Sheet, Joineries, Roof Treatment, Att, Sunken Floor, Saintary Fittings, Welcome Maintenance Of Various Md Accn, Painting Of External Services And Repair/ Maintenance Of Damaged Water Supply, Main Pipe Line/ Di Pipe Line, Lt Panel, Motor Pumps, Cleaning Of Tanks At Jamshedpur Under Ge Ranchi
BOQ
| Sl. No. | Item Description |
| 1 | M&L for taking up/ down of GI pipes including all fitting from trenches/walls /floors and connections etc complete all as specified and directed at site. |
| 2 | (a) 15 mm bore dia |
| 3 | (b) 20 mm bore dia |
| 4 | (c) 25 mm bore dia |
| 5 | (d) 40 mm bore dia |
| 6 | (e) 50 mm bore dia |
| 7 | (f) 80 mm bore dia |
| 8 | (g) 100 mm bore dia |
| 9 | Relaying only GI tubes any grade in trenches materials obtained from Item No.1 here-in-before after cleaning or rerunning the old screw threads with replacement of unsv fittings and fixtures for following size of complete as directed. |
| 10 | (a) 15 mm dia |
| 11 | (b) 20 mm dia |
| 12 | (c) 25 mm dia |
| 13 | (d) 40 mm dia |
| 14 | (e) 50 mm dia |
| 15 | S&F in replacement tubes,' medium grade', galvanized, with all fittings; laid in trenches of following sizes: |
| 16 | (a) 15 mm bore dia |
| 17 | (b) 20 mm bore dia |
| 18 | (c) 25 mm bore dia |
| 19 | (d) 40 mm bore dia |
| 20 | (e) 50 mm bore dia |
| 21 | (f) 80 mm bore dia |
| 22 | (g) 100 mm bore dia |
| 23 | S&F in replacement Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, for following bore dia:Make-Shakti/Scud, for the following bore dia : (Note : Gate valve fixed and removed at difrent places.) |
| 24 | (a) 15 mm dia |
| 25 | (b) 20 mm dia |
| 26 | (c ) 25 mm dia |
| 27 | (d) 40 mm dia |
| 28 | (e) 50 mm dia |
| 29 | M&L for Bends (any type, radius and angle) tapers any type,(straight, bend, increasing, decreasing or double socket etc.)Tee pieces single branch. \\"Y\\" junction, double branch, cross (all sockets or socket and spigot) all as specified and as directed , upt 150mm bore dia collars, caps and plugs |
| 30 | M&L for Rubber gasket joint for flange joint all as specified and as directed , upt 150mm bore dia |
| 31 | Description all as per above Ser Item No 6 above but size 80mm bore pipe |
| 32 | M&L for repair existing leakage of GI pipe line 15 to 25 mm bore by welding or cutting and making threading for insertion nipple, socket, union socket, pipe piece up to 01 mtr for any place complete all as specified and directed by Engineer-in-charge. |
| 33 | Attending complaints of BLOCKAGE OF WATER PIPE LINES / NO WATER SUPPLY AT ANY kind of ACCOMODATION (MARRIED / OTM/ single / multi story building), IDENTIFY THE FAULTS including rectification by taking down of existing GI/ PPR tubing up to 80 mm bore, cutting/ threading and making joints and cleaning for any blockages, opening of float valve of service tanks, cleaning and fixing the same in its position, replacement of valve/ packing sheet of gate valve and including replacement of GI unions/ sockets/ nipples etc as required at site to RESTORE WATER SUPPLY complete all as specified and directed.Notes:- (i) The contractor will be allotted complaints at MES complaint cell on requirement basis on all working days including Sundays and holidays.(ii) Contractor is responsible for repair/ replacement of any damages to the existing structures, Under Ground HT/ LT/ OFC Cables etc during the course of execution. (iii) Spares/ GI fittings required to be replaced and shall be measured and paid separately under respective items. |
| 34 | Supply and fixing in replacement of float valve brass, high pressure with polythene float and fly nut complete screwed for iron pipe of following sizes:- |
| 35 | 25 mm dia |
| 36 | 20mm dia |
| 37 | S&F in repais, Brass foot valve ball type heavy duty suitable for 80/100 mm bore pipe line including dismantling of old unserviciable foot valve any type and make from suction pipe of pumpset at any place complete all as specified and directed by Engineer-in-charge.Note (a) The rate quoted for above item are deemed to be included the cost of minor repair/alteration to the pipe or fixing of above foot valve complete. (b) The all complaint should be done within two days of any place/location other wise Rs. 500/- panality recovered from the contractor. |
| 38 | Cutting the existing road of any kind straight by manual, depth and width not less than 30 cm for pipes up to 350 mm dia and 60 cm for pipes from 150 mm to 150 mm dia and 75 cm for pipes and filling back with excavated soil up to 75 % road portion and 25 % shall be made with cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate complete all as specified and directed. |
| 39 | M&L for PCC (1:4:8) type D2 using 40 mm graded stone aggregate in foundation mass concrete and filling including weathering slightly rounded or chamfered complete with necessary use and waste fo form work complete all as specified and directed at site. |
| 40 | M&L mild steel as in cross arms bracing supports clamps and back planes fabricated from structural steel section including nut, bolts washers welding drilling holes for bolts in any shape and size as indicated or directed and inclusive of one proimer coat one under coat one finishing coat of aluminium paint complete. paint complete to support the cables all as specified. |
| 41 | S&F CI / DI specials such as bends (any type, radius or angle) tapers any type (Straight, bend, increase, decrease or double socket etc) tee pieces, single 'Y' branch, double branch cross (all sockets, socket and spigots, collars, cap plugs etc up to 150 mm bore complete all as specified and directed. Please Enable Macros to View BoQ information |
| 42 | S&F CI / DI specials such as bends (any type, radius or angle) tapers any type (Straight, bend, increase, decrease or double socket etc) tee pieces, single 'Y' branch, double branch cross (all sockets, socket and spigots, collars, cap plugs etc up to 150 mm bore complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents