Tender For Repair To Path, Hardstanding, Culvert, Fencing, Jaffery Wall In Mcc Basant Nagar Under Age B/R-Ii At Ge Af Palam, Delhi Cantt-10
Tender Overview
Project Description
Tender for Repair To Path, Hardstanding, Culvert, Fencing, Jaffery Wall In Mcc Basant Nagar Under Age B/R-Ii At Ge Af Palam, Delhi Cantt-10
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 11-Aug-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 18-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of brick work built in cement mortar, including all quoins, arches, pillars etc of any description including removing debrish from site complete all as specified and as directed. |
| 2 | Demolition of concrete in ground floor and pavings n.exc 15 cm thickness below or above ground level complete all as specified and as directed. |
| 3 | Demolition of reinforced concrete roofs, floors (other than ground floors), beams, staircases, landing, chajjas, slabs and similar suspended work complete all as specified and as directed. |
| 4 | Taking down cement plaster or cement lime plaster on brick or stone walls etc including raking out joints, hacking for keys, scrubbing down with water etc complete all as specified and as directed. |
| 5 | M&L for brick work with sub class `B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified and as directed. |
| 6 | Description all as per ser item No. 5 above but except bricks complete all as specified and as directed. Note:- Old brick shall be retrieved from ser item No. 1 here in before. |
| 7 | M & L for brick work with sub class ‘B’ bricks, straight or curved on plan of any radius in half brick thick wall built in cement mortar (1:4) complete all as specified and as directed. |
| 8 | M&L for 15 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:6), surface finished even and smooth without using extra cement complete all as specified and as directed. |
| 9 | M&L for 15 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:4), to be finished even and fair mixed with water proofing compound as per manufacturer's instructions with and including necessary scaffolding up to 4 storey building complete all as specified and as directed. |
| 10 | M&L for washed stone grit plaster (of any colour/ pattern) on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 coloured stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and directed by Engr-in-Charge. (Note :- Payment for providing grooves shall be measured and paid separately). |
| 11 | Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge |
| 12 | M&L for preparation new/ old decorated surfaces of walls and cornices, spoiled by smoke soot, moulds, moss and efflorescent salts and trading oily and greasy spots by scraping and washing with water and applying two coats of cement base paint complete all as specified and as directed by Engineer-in-Charge. |
| 13 | M&L for preparation of new/ old plastered or un plastered old decorated surfaces of walls removal of nails etc & filling cracks/hole by applying cement base wall care putty as required (multipurpose mixer shall be used for uniform and proper mixing of putty) and applying one coat of exterior emulsion paint 100% acrylic of approved white or coloured tint complete all as specified and as directed by Engineer-in-Charge. Note:- The work shall be carried out upto four storey. Necessay scafolding upto four storey bldg shall be deemed to be included in unit rates. |
| 14 | M&L for preparation of new or previously untreated surfaces of steel of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 15 | Material and labour for preparation of old painted surfaces of steel and iron surfaces of any description not otherwise described over 10 cm width & girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 16 | M&L for providing reinforced cement concrete nominal Mix (1:2:4) type B-1 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 17 | Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings, slabs supported on walls, beams and columns in floors and similar work; (Horizontal or sloping) complete all as specified and as directed. |
| 18 | M& L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 19 | M&L for 5 to 10 mm dia TMT bars, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends for strrrups and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed. |
| 20 | M&L for granite(18-20mm thick Z Black coloured) work in walls, beams and columns, counter for cooking platform etc including rounding and grinding of edges and like laid on cement mortar (1:4) including pointing in white cement (1:2) using marble dust and admixture of pigment to match with shade of granite including cutting for hole, rounding of edges and mirror polishing complete all as specified and as directed. Note:- (a) Unit rates includes for necessary raking, circular cutting or notching and waste on granite in this item. (b) This cost of WHB counter top /cooking platfom counter top etc shall be measured and paid seperately. |
| 21 | M&L in repair providing precast cement concrete louvers and jallies 50 mm thick (measured solid) in cement concrete (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) and set in cement mortar (1:4) including all mouldings but excluding frame complete all as specified and as directed. |
| 22 | S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to Fe-410-0 or Fe 310-0 complete all as specified and directed by Engineer-in-charge. |
| 23 | M&L for framed work as in door or gates or other section with gusset plate rail bracing etc complete drilled for fixing of steel sheeting or other covering to doors etc to be prepared for hanging or sliding with and including either hook and hinges or steel hanging door fittings running rail and guides and hanging also fastening and fixing & conforming to grade Fe-310- O complete all as specified and as directed. |
| 24 | S&F 1.6 mm thick plain, black, mild steel sheeting as in door coverings complete all as specified and as directed by Engineer-in-Charge. |
| 25 | S&F collapsible steel gates top hung consisting of channel pickets, pivoted flat bars, box and bottom runners, brass handles etc as specified and erected in position and securing runners with hold fasts and brackets complete all as specified and as directed. |
| 26 | M&L for cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in coping, cills, steps, parapets, railings up to 60cm in height, water troughs and the like rounded or chamfered on edges including necessary use and waste of form work complete all as specified and as directed. |
| 27 | Excavation in trenches exceeding 1.50 metre wide and not exceeding 1.50 metre depth for foundation, manhole etc not exc 10 Sqm on plan and not exc 1.5 metre in depth including getting out in soft/loose soil complete all as specified and as directed. |
| 28 | Returning, filling in including spreading, leveling watering and well ramming in layers not exceeding 25 centimetre in soft/loose soil complete all as specified and as directed. |
| 29 | Removing excavated surplus soil/material not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed. |
| 30 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 31 | S&F mild steel work such as angle iron post , flat iron in fencing including cutting as making doubble swan neck i.e. \\"Y\\" shaped including welding with proper overlapping & welding MS Plate with angle iron bottom as directed, drilling holes notching for wire etc embedded in concrete fixed vertically conforming to Fe 290 grade E-165 complete all as specified and as directed. Note:- Embedded portion of Angle Iron post shall be painted with red oxide primer. |
| 32 | Supply and fixing concertina coil with punched tape of 600 mm dia, centre core wire shall be minimum 2.5 mm dia of mild steel wire conforming to IS 280-2006. Galvanised coating of steel concertina coil shall confirm to the requirements as laid down for medium coated wire in IS 4826 \\"Hot dipped galvainsed coating of round steel wires\\" concetina coil shall be fixed in diamond shape with the help of dovetail two handle and spikes shall be fixed at both end of coil, minimum straight length of the wire 150 RM of 10 RM of work, minimum weight 13.5 Kg for 10 RM of work i.e. 90gm per RM of wire complete all as specifed and directed. |
| 33 | S&F galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins etc with taking down barbed wire of any description in any position complete all as specified and as directed. Note:- Each line of wire shall be measured. |
| 34 | Dismantling post or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground (Post embedded in concrete / brick / stone masonry etc) complete all as specified and as directed. |
| 35 | Dismantling of fencing of any description any thickness complete complete all as specified and as directed and directed by Engineer-in-Charge.. |
| 36 | S&F 4 mm dia chain link MS galvanised fencing of mesh size (75x75)mm size including line wire, fillets, straining bolts etc complete all as specified and as directed. |
| 37 | M&L in repair for chain link fencing 4 mm dia of galvanized steel wire (150 x 100) mm mesh made up into mattresses or cages, lapped wire & laid in position including closing after filling etc including binding with wire complete all as specified and as directed. |
| 38 | M & L for mild steel works(Fe-290 Grade E-165) as in posts and struts etc in fencing of angle or other sections, including cutting tops to shape as directed, drilling holes, notching for wire etc, complete all as specified and directed. |
| 39 | M&L for mild steel plain bar 10 mm dia. and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and as directed. |
| 40 | Demolition of cement concrete of other than ground floors in any position and any description not other wise specially provide for complete included removing the debris outside MD land all as specified and as directed by Engineer-in-Charge. |
| 41 | M & L for machine pressed, glossy finished 25 mm thick coloured cement concrete chequered tiles of size 300mm x 300 mm of pattern as approved set, jointed and pointed in neat cement slurry and pigment in floors with and including over cement screed bed of 15mm thick in cement mortar (1:6) complete all as specified and as directed. |
| 42 | M&L for glossy finished machine pressed precast concrete interlocking paver block 60mm thick any shape and size, with grey cement and pigment to match, conforming to IS 15658-2006 M-35 grade with and including laid over 50 mm thick sand cushioning complete all as specified and as directed. |
| 43 | S&F 25 to 35 mm thick machine cut grinded Dholpur sand stone slab of size not less than 0.30 sqm as in floors /wall etc fixed with and including over 15mm thick cement mortar in (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of stone etc complete all as specified and as directed by Engineer-in-charge |
| 44 | M&L in repair for 14-16 mm thick marble (Udaipur Green) tiles machine cut as in skirting/dado set and jointed with grey cement slurry & pigment to match the tiles including cutting and polishing with and including over 10mm thick rendering in cement mortar (1:4) complete all as specified and as directed by Engineer-in-Charge. |
| 45 | M&L for plain cement concrete (1:2:4), type B-2 (using 40 mm graded crushed stone aggregate) as in surface channel, drain and bedding including necessary use and waste of form work and weathering, slightly rounded or chamfered angles complete all as specified and as directed. |
| 46 | M&L for precast cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) type B-1 as in manhole /drain slab cover set with CM (1:4) complete all as specified and as directed. |
| 47 | M&L for providing precast cement concrete rubber moulded coloured chequered tiles 80 mm thick even finish on top in shape/design with and including laid over 25 mm thick sand cushioning complete all as specified as directed. |
| 48 | M&L for 75mm thick cement concrete (1:3:6) type C2 (using 40 mm graded stone aggregate) as in hard standing/pavings/plinth protections, finished even and smooth without using extra cement complete all as specified and as directed. |
| 49 | M&L for 40mm thick cement concrete (1:2:4) type B-1, (using 20 mm graded stone aggregate) as in floors including finishing surface even and smooth without using extra cement complete all as specified and as directed. |
| 50 | M&L for 75mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base for floor finishes complete all as specified and as directed. |
| 51 | Taking down Chowkats or frames with shutters (without taking off shutters from the frames) area upto 4 Sqm each and credited to the contractor, complete all as specified and directed.Note:- The damaged portion of the tiles / rendering shall be made good with the same material to match with the adjacent surface. |
| 52 | M&L for aluminium anodised powder coated frame work as in partition wall /Doors/ windows/ ventilators/ sliding shutters by using suitable section conforming to IS-733 and IS-1285 and coating grade A-153 conforming to IS-1868 & fixed with rawl plug and screws or with fixing clips with expansion hold fasteners including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap grid beading etc gap of junction at top and bottom and sides filled with PVC Neoprene felt including necessary provision of aluminium grills to windows/ventilators etc compete all as specified and as directed by Engineer-in-Charge. Notes:- (a) Aluminium section shall be of non rusted and bright finish completely (internal & external side). (b) Aluminium section shall be mechanically jointed wherever required. (c) Aluminium section size shall be approved by GE. (d) Aluminium section, snap gird, cleat angle shall be screwed with chromium plates brass screw as directed by Engineer-in-charge. (e) The weight for all necessary fitting such as cleats, glazing clips, rubber packing/ PVC item/raw plug material/bass screw etc which are required for fabrication shall not be incuding in the weight of aluminium for the payment. The weight of aluminium section shall be cosidered no extra payment for fabrication matarial. |
| 53 | M&L for powder coated aluminium grill make DECO Cat No DG-104 or Jindal section complete all as specified and as directed. |
| 54 | S&F 5.5mm thick selected quality tinted sheet glass and glazing in square fixed with PVC /Neoprene gasket in aluminium frame work complete all as specified and as directed. |
| 55 | S&F locks, drawer, grade, size 100 mm 4 lever brass complete all as specified and as directed. |
| 56 | S&F aluminium barrel tower bolts of extruded section and fixed of size 100 mm complete all as specified and as directed. |
| 57 | S&F ISI marked 150mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed. |
| 58 | S&F 100mm long butt hinges extruded aluminum alloy with galvanished mild steel hinges pin, anodized & fixed, type C-21 complete all as specified and as directed. |
| 59 | M&L for aluminium gate and shutter hooks and eyes of size 150mm complete all as specified and as directed. |
| 60 | S&F aluminum anodized handles cast type of 200 mm long complete all as specified and as directed. Note :- All above aluminium mongery / fittings shall be powder coated used in aluminium door /window etc as above item and shade of coating shall be approved by the GE. |
| 61 | S&F factory made 18 mm (+0.7mm thick celuka PVC board of density 600 kg/cum manufactured by an ISO 900-2008 certified company having one side perlaminated and other side plain fixed as in cabinet/ cupborad shutters etc including provding manufactures test report and test certificate is mandatory with each and every supply of material including taking down of exiting shutter or any kind of PL board or plyboard complete all as specified and as directed. |
| 62 | S&F door closer hydraulically regulated designation No 3 universal type suitable for door shutter of 851 to 1000 mm in width of Aluminum body (die cast) weight between 61 to 80 kg complete all as specified and as directed. |
| 63 | S&F double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminum alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other party made of mild steel heavy duty complete all as specified and as directed. |
| 64 | S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 65 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premices complete all as specified and directed. |
| 66 | M&L for joint free non skid coloured ceramic tiles, 7 to 8mm thick (squre or rectangular) area of each tile n.exc. 0.11sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces, laid over & including 15mm thick screed bed in cement mortar (1:6) complete all as specified and as directed. |
| 67 | M&L for joint free anti skid coloured ceramic tiles, 7 to 8mm thick (squre or rectangular) area of each tile exceeding 0.11sqm but n.exc. 0.18sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces, laid over & including 15mm thick screed bed in cement mortar (1:6) complete all as specified and as directed. |
| 68 | M&L for joint free coloured glazed ceramic tiles in vertical surfaces of size (300x200)mmx7mm thick/ (450x300)mm x7mm thick, set and jointed in cement slurry and pointed in white or coloured cement to match laid over & including 15mm thick cement rendering in cement mortar (1:4) complete all as specified and as directed. |
| 69 | M&L for Durastone vitrified tiles coloured, light shade 10 mm thick, area of each tile exc 0 .06 but not exc 0.36 Sqm in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match e surfaces, laid over & including 15mm thick screed bed in cement mortar 1:6 complete all as specified and as directed. |
| 70 | M&L for machine cut Kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab (slab size not less than 55 cm x 55 cm) with and including rubbing and mirror polishing complete with and including laid over 15mm thick screed bed in CM (1:4) wih a coat of cement slurry @ 3kg/sqm complete all as specified and as directed. |
| 71 | M&L for machine cut Kota stone slab flooring 18-20 mm thick as in riser of steps, skirting, dado over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab with and including rubbing and mirror polishing complete with and including laid over 10mm thick rendering in CM (1:4) complete all as specified and as directed. |
| 72 | Dismantling plain or corrugated steel sheeting any gauge, thickness, incuding nainital or similar pattern sheets in roof coverings complete all as specified and as directed. |
| 73 | S&F mild steel work (FE 290 Grade E-165) as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel, hollow section or flat sections) including distance pieces, cleats etc., complete all as specified and as directed. |
| 74 | S&F Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to fix the wall or fixed with self taping screws with rubber washer etc complete all as specified and as directed by Engr-in-Charge. Note:- pattern, design and colour of sheet shall be as approved by GE/ Engr-in-Charge. |
| 75 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws with rabber washer complete all as specified and as directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
| 76 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws with rabber washer complete all as specified and as directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender