Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #56572428

Tender For Repairs To Roof Treatment ,Leakage,Seepage Of Walls Chajjas Facia Balcony And Replacement Of Damaged Drain Pipe And Water Pipelines To Certain Buildings In Residential Area Of Npol Kochi .

Issued by Statutory Bodies & Commissions/Committees · Ernakulam, Kerala
Tender Value
19 Lakhs
Estimated cost
Bid Submission
10 Aug 2026
19 days left
EMD
38000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repairs To Roof Treatment ,Leakage,Seepage Of Walls Chajjas Facia Balcony And Replacement Of Damaged Drain Pipe And Water Pipelines To Certain Buildings In Residential Area Of Npol Kochi .

BOQ

Name of Work:- REPAIRS TO ROOF TREATMENT ,LEAKAGE,SEEPAGE OF WALLS CHAJJAS FACIA BALCONY AND REPLACEMENT OF DAMAGED DRAIN PIPE AND WATER PIPELINES TO CERTAIN BUILDINGS IN RESIDENTIAL AREA OF NPOL KOCHI .
Sl. No. Item Description
1Taking down existing water proofing treatment of any thickness from the roof /parapet including cement mortar bedding , PCC tiles, padding concrete if any, upto the RCC slab, removing debris off the premises and cleaning the roof complete all as specified
2Cutting the V grooves on the terrace slab where ever cracks are observed and fill the grooves with Fosrocs heavy duty non shrink grout Convextra GP2 , coving all the 90 degree angles , slab/wall junctions with Conbextra GP2 all as per manufacturer's instruction.
3M&L providing a levelling course of cement concrete type B-0, 1:2:4, using 12.50 mm stone aggregate, 40 mm thick maintains a slope towards the drain water pipes by adding a water proof admixture @ 250 ml per bag of cement.Note :-Admixture shall be measured and paid separately.
4M&L for rendering with CM 1:3, 10 mm thick mixed with water proofing admixture of Fosroc/Pidilite or equivalent, all as specified and directed. Note :-Admixture shall be measured and paid separately.
5Supply only liquid water proofing admixture.
6M&L for Poly Urethane based water proofing treatment to existing RCC roof slab with the following specifications) Cleaning the existing surface by mechanical means to make it free from any bituminous residue/dirt, oil and grease all as directed by Engineer In Charge.ii)M&L for cracks treatment by cutting open cracks and cleaning it from dirt’s , loose materials etc and filling with Polyurethane based sealant with and including application of PU based primer all as directed by Engineer In Charge. iii)M&L applying water based polyurethane modified dispersion(single component, cold applied , non toxic , VOC compound) in three coats including one coat of primer of same material after dilution of water at 50% or specific primer matching same material as per manufacturer specification and as directed by Engineer In Charge. Note:- Properties of Poly urethane based chemical shall conform to following technical parameters a)Highly elastic b) UV resistance c)Adhesion to concrete > 1N/ Sqmm d)Tensile strength-not less than 2.0 N/Sqmm for free film Elongation not less than 300% e) Solid content by weight not less than 60% f)Air/Water permeability BSEN 12390 at 5 bar -72 hours should be NIL and minimum dry film thickness of water proofing membrane must be 1.00mm g)Accelerated weathering(ASTM 453) Pass 1000 hoursh) Reaction to fire - Non inflammable j) To be applied by the rep of manufacture’s authorised applicator only. Contractor has to be provide manufactures test certificate for the above mentioned Technical parameters and purchase vouchers. k)Removal of existing treatment to be paid separately l)Roof slop to be ensured to avoid water ponding/logging m) 300mm height of vertical surface/parapet wall to be treated with the same specification .Make:- Bostic,Berger,Fosroc, Sika, Asian or any other make approved by E-In -C\\"S branch
7APP modified polymeric membrane minimum weighing 3.5 Kg/Sqm and minimum 3 mm thick reinforced with polyester non woven fabric (not less than 160 gsm/sqm) laid over primed surface including bituminous primer conforming to IS-3384 applied @ 0.3 Ltr/Sqm by forced application all as specified and directed including(i) Applying one coat of bituminous primer conforming to IS-3384 @ 0.3 Ltr per Sqm. (ii) Laying of APP modified membrane as specified thickness and weight as per manufacturer’s instructions (iii) Applying one coat bitumen grade 85/25 @ 1.2 Kg/Sqm conforming to IS - 702(iv) Applying two coat of aluminum paint @ 100 ml/sqm for each coat
8M&L for applying Two or more coats of including preparation of old decorated or unplastered surfaces of walls 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces Complete all as specified and directed.
9Dismantling water tanks Exc 500 and n exc 1000 ltrs and removing to store all as specified and directed.
10S & F Rotational moulded polyethylene water storage tanks 500 ltrs (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed.
11S & F Rotational moulded polyethylene water storage tanks 1000 ltrs (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed.
12Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) 500 but not exceeding 1000 litre
13Dismantling 75/100mm dia CI pipe jointed in cement mortar and taking out of trenches as required.
14S & F PVC (SWR) pipes 110mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors
15S & F PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls 75 mm bore.
16S & F PVC (SWR) bends any radius 110 mm dia all as specified and as directed.
17S & F PVC (SWR) bends any radius 75 mm dia all as specified and as directed.
18Taking up or down steel water tubing 15mm and 20mm bore and connection complete all as specified and directed by Engineer-in-Charge
19Supply and fix Unplasticised PVC pipes of bore 20 mm pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe all as specified and as directed
20Supply and fix Unplasticised PVC pipes of bore 25 mm pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe all as specified and as directed
21S&F in repairs bib taps 15mm bore, cast copper alloy chromium plated with crutch or butterfly handle, fancy type, screwed for iron pipe or for brass ferrule all as specified and as directed
22S&F in repairs stop valves 15mm bore, cast copper alloy chromium plated fancy type, screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions all as specified and directed.
23Taking down old plaster and rendering 10mm thick in CM 1:6 on other than fair faces of brick or concrete surfaces finishing smooth and even and smooth without using extra cement making good match the old surface finish.
24M&L Applying one coat of oil bound distemper over a coat of primer including preparation of old decorated or unplastered surfaces of walls including cornices, pilasters by brooming down or steel wire brushing, scrapping down, smoke soot moulds, moss and efflorescent salts and greasy spots and complete all as specified and directed by Engineer-in-Charge
25Demolition Brickwork or stone/boulder masonry, built in lime mortar including all quoins, arches, pillars ,etc, but excluding ashlar facings, dressed stonework and precast concrete articles
26Providing Pre-cast cement concrete block masonry with solid blocks, exc. 10cm in width and setting in mortar,1:6complete, with Type C1 1:3:6(20 mm graded aggregate)
27Extra for forming fair finished drain or channel 30cm inner girth (inner girth shall only be measured and paid) in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc., complete all as specified and directed.
28Rendering 10mm thick in CM 1:3 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement duly mixed with water proofing compound all as per manufacturer’s instructions, complete all as specified and directed.
29Demolition and breaking up drain pipes 150 mm internal dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar all as specified and directed.
30Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in plain cement concrete 1:3:6 type C1 (20mm graded stone aggregate) for 150mm bore of pipe, complete all as specified and directed
31M&L Reinforced concrete drain pipes, class NP3, 150mm internal dia of pipe, pipes shall be laid level or to falls in trenches or on concrete bed and jointed complete with collars as specified, complete all as specified and directed.
32Dismantling floor, hearth or wall tiling including cement mortar bedding (but no backing), removing serviceable tiles to store and rubbish off the premises
33M&L 25mm thick Cement concrete type B-0,1:2:4 (12.5mm graded aggregate) complete all as specified and directed.
34M&L colored chequered cement concrete tiles glossy finished 30cm x 30cm x 25 mm thick, with grey cement & pigments set, jointed and pointed in neat cement slurry in floors including 15 mm thick screed bed in cement mortar (1:4) and laying floor finishes complete all as specified and directed by Engineer-in-Charge.
35Supply and laying fine aggregate 50mm thick spreading and levelling in layers n exc 25cm thick incl consolidation complete all as specified and directed.
36M&L for Machine pressed precast concrete interlocking paver block (shape as per sample in AGE B/R (P) sample room), with grey cement and pigment and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade complete all as specified as directed by Engr-in- Charge
37PCC 1:3:6 type C-1(20 mm graded aggregate) as in copings including necessary form work, complete all as specified and directed.
38M&L Applying one coat of oil bound distemper over a coat of primer including preparation of old decorated or unplastered surfaces of walls including cornices, pilasters by brooming down or steel wire brushing, scrapping down, smoke soot moulds, moss and efflorescent salts and greasy spots and complete all as specified and directed by Engineer-in-Charge
39Dismantling of wrought iron or mild steel work of any description not otherwise provided for
40S & F structural steel in roof trusses (framed), trussed, purlins, rails and fastenings and heavy bracket framing including distance pieces, cleats etc(F-290 Gd E-165) complete all as specified and directed.
41M&L for Two coat of synthetic enamel paint on new steel surface, including preparation of surface, of any description over 10CM width or girth not otherwise described over one coat of red oxide complete all as specified.
42Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
43S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56572428
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 19 Lakhs
LAST DATE 10-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repairs To Roof Treatment ,Leakage,Seepage Of Walls Chajjas Facia Balcony And Replacement Of Damaged Drain Pipe And Water Pipelines To Certain Buildings In Residential Area Of Npol Kochi .
Basic Detail
Tender No 8422E8AGEIRDK
Bidding Type Tender
Location
City Ernakulam
State Kerala
Key Dates
Publish Date 20 Jul 2026
Submission Date 10 Aug 2026
Open Date 17 Aug 2026
Finance
Tender Value 19 Lakhs
Tender Fee 500
EMD 38000
Exemption Available
Document List
8422TENDERDOCUMENTS.pdf
a046aad5-51b5-4df7-9519-19d047f93d14.html
BOQ_873433.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Aug 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 26 days

Tender Documents

Download All (ZIP) ↓
pdf

8422TENDERDOCUMENTS.pdf

html

a046aad5-51b5-4df7-9519-19d047f93d14.html

xls

BOQ_873433.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders