Tender For Addn/Altn To Drain Near Bldg No Od-14 And Special Repair To Compound Wall/Retaining Wall And Associate Work Behind Command Museum Inside Vijay Durg Under Ge(Vd) Kolkata
Tender Value
39.50 Lakhs
Estimated cost
Bid Submission
10 Aug 2026
18 days left
EMD
79000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Addn/Altn To Drain Near Bldg No Od-14 And Special Repair To Compound Wall/Retaining Wall And Associate Work Behind Command Museum Inside Vijay Durg Under Ge(Vd) Kolkata
BOQ
| Sl. No. | Item Description |
| 1 | (B/R PORTION)Demolition of brick work/stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work and pre-cast concrete articles all as directed. |
| 2 | Dismantling wrought iron or mild steel work of any description not otherwise provided for all as directed. |
| 3 | Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thick above or below ground level all as directed. |
| 4 | Demolition of Reinforced Cement Concrete(reinforcement cut as required to facilitate demolition) of any description or in any position not otherwise specifically provided for all as specified and directed. |
| 5 | Excavation in post holes (or similar holes) each not exceeding 0.50 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50 m and making good surfaces in soft/loose soil all as directed |
| 6 | S &F framed work such as grills, grating etc with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, barried iron doors ladders framed balusters, walk ways, railing framedwork of water tanks and similar work conforming to Fe.290 Gde E-165 complete complete all as specified and directed. |
| 7 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 all as specified. |
| 8 | Material and labour for preparation of new and previously un-treated steel surfaces of any description, not otherwise described over 10cmwidth or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer all as specified and directed. |
| 9 | Material and labour for providing Plain Cement Concrete (1:3:6) type C2 using 40mm graded aggregate as in foundation, filling and mass concrete all as specified and directed. |
| 10 | M&L brick work with Fly ash bricks old size brick straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 complete all as specified and directed. |
| 11 | Material and labour for providing Plain Cement Concrete (1:4:8) type D2 using 40 mm graded aggregate as in foundation, filling and mass concrete all as specified and directed. |
| 12 | Taking down cement plaster, of any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water all as directed.. |
| 13 | M&L rendering 15 mm thick cement plaster in two layer each of 10+5 mm thick on fair face of brick work or concrete surface on external surfaces in CM (1:4) & water proofing compound mixed with second layer @ 250 ml/Bag or as per manufaturer instruction finished fair and even. complete all as specified and directed. ( Note -W.P.C. shall be measured and paid separetly . |
| 14 | Supplying Integral water proofing compound. |
| 15 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on new surfaces complete all as specified and directed |
| 16 | M&L for preparation of new surfaces of walls and soffit of chajja, roof slab etc by cleaning, brooming, rubbing and scrapping as required using broom, emery paper putty blade/scraper as applicable to make the surface free from protrutions, loose particles, dust etc including necessary safety & protective measures such as safety belt headgear etc, finishing the surface with 1mm thick exterior wall putty for smooth finish and finishing with two coats of weather proof exterior emulsion paint over a coat of suitable exterior primer of approved make using airless spray technology capable of operating single spray gun with hose of adequate length and necessary scaffolding for upto 4 storey building height complete all as specified |
| 17 | M&L brick work with Fly ash bricks' old size brick straight or curved on plan to any radius built in cement mortar 1:4 as in half brick thick wall complete all as specified and directed. |
| 18 | M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 finished rendering surfaces even and smooth (without using extra cement) complete as specified and directed. |
| 19 | Material and labour for providing Plain Cement Concrete (1:3:6) type C1 using 20mm graded aggregate as in surface channel and drain all as specified and directed. |
| 20 | M & L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring benching to drain, coping, etc and the like edge slightly rounded or chamfered including necessary use and waste of form work complete all as specified and as directed. |
| 21 | Supply and fix 150 mm internal dia cast iron soil, waste and vent pipes, jointed in cement mortar and taking out of trenches if required all as specified and directed. |
| 22 | Dismantling 150 mm internal dia cast iron soil, waste or reinforced concrete drain pipe and vent pipes, jointed in cement mortar and taking out of trenches if required all as specified and directed. |
| 23 | Supply and fixing in repair 150 mmCI bends any radius complete all as specified and directed. |
| 24 | Supply and fix 100 mm dia cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed. |
| 25 | Supply and fixing in repair 150 mm CI bends (any radius) diminishing pieces or tappers (larger bore measured) any radius with oval access doors complete all as specified and directed. |
| 26 | (E/M PORTION)Supply, install, commissioning and testing of Indoor type LT panel board, cubical type,mounting in PCC base dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 1200mm x 1200mm x 500mm, CPRI approved with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, duly painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer inclusive of four numbers Aluminium bus bar 300 Amps of size 50mm x 6mm (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland),and 02 Nos Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with angle iron frame with base 50 x 50 x 6 mm with legs not more than 300mm long including grouting with PCC (1:2:4) complete including earthing all as directed by the Engr-in-Charge including supply and fixing of the following accessories:- Make : Star Electric & Engg Co/ CPRI approved. |
| 27 | INCOMING |
| 28 | (a) MCCB design with Microprocessor Release of capacity 200A, 4P, 36 KA - 01 Nos (Incoming)+ Both End Spreader Link. Make : Legrand/Schnider/Siemens |
| 29 | OUTGOING |
| 30 | (a) MCCB design with Microprocessor Release of capacity 100 Amps, 4 Pole, 25 KA - 01 Nos (Outgoing). + Both End Spreader Link.Make : Legrand/Schnider/Siemens |
| 31 | (b) MCCB design with Microprocessor Release of capacity 63 Amps, 4 Pole, 25 KA - 03 Nos (Outgoing). Both End Spreader Link.Make : Make :Legrand/Schnider/Siemens |
| 32 | (c) MCCB design with Microprocessor Release of capacity 63 Amps, 4 Pole, 25 KA - 03 Nos (Outgoing). Both End Spreader Link.Make : Make :Legrand/Schnider/Siemens |
| 33 | METERING INSTRUMENT |
| 34 | (a) Digital Ammeter with Selector Switch - 01 Nos. Make : L&T |
| 35 | (b) Digital Voltmeter with Selector Switch - 01 Nos. Make : L&T |
| 36 | (c) MCB SP 6 Amps, 10 KA - 3 Nos. Make : L&T |
| 37 | (d) LED type indication lamp R Y B - 01 set. |
| 38 | (e) Current Transformer Ratio 200/5A - 03 Nos |
| 39 | Note:-(i) All incoming and outgoing cables, duly thimbled along with suitable size of brass cable glands, to be connected with accessories. (ii) All MCCB & Changeover to be connected internally with suitable size of copper strip. (iii) Earthing as per SSR 19472 and incl earth work,PCC pit and RCC cover,watering pipe 20 mm dia light grade,funnel,wire mesh,protection pipe 15 mm dia light grade , charcoal dust and salt etc and connected to earthing test point including taking up of old UNSV earthing complete all as specified and directed by Engr-in-Charge. |
| 40 | Excavation in trenches not exc 1.5 mtr width and not exce 1.5 mtr in depth in soft/loose soil and getting complete all as specified and as directed. |
| 41 | M&L for sand cushioning /sand covering for underground cable protection and consolidated and compacted with clean dry sand complete all as specified and as directed. |
| 42 | M&L bricks with sub class 'B' locally available laid in trenches above sand cushioning for cable protection complete all as specified and as directed. |
| 43 | Laying in Trenches Bricks (Serviceable Bricks obtained from Item No. 9.00 here-in-after), for Cable Protection, complete all as specified and as directed. |
| 44 | Returning, filling in including spreading levelling watering and well ramming in layers n.exc 25 thick for soft/loose soil complete all as specified and as directed. |
| 45 | Removal of excavated material to a disance n.exc 50 mtr and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed. |
| 46 | Excavation/Cutting Road/ Hardstanding in Trenches not exc. 1.00 Meter wide and not exc. 1.00 Meter in depth and getting out, complete all as specified and as directed. |
| 47 | Supply, Laying and testing for replacement of XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall with saddles/Flat iron clamps as per site requirement /passing through pipe/pole complete of the following sizes and cross sectional area :-Note :- Necessary earth work to be measured and paid separately. |
| 48 | 70 Sqmm, 3.5 Core |
| 49 | 35 Sqmm, 3.5 Core |
| 50 | 50 Sqmm, 3.5 Core |
| 51 | S&F of Feeder Pillar Box of size 60x60x45 Cm, made out of CRCA Sheet 3.0mm thick, Outdoor, Pedestal type, Weather Proof, Epoxy based Powder Coated Paint, Self-Closing Door having with Locking Arrangement, mounted on brick work Platform of size 100x100x60 Cm with plastering, comprising with 4 No. Aluminium Bus-bar of current rating 600 Amp with and including 1 no. MCCB 160 Amp 25 kA, 4 Pole, complete all as specified and as directed. |
| 52 | M&L for Galvanised Steel Tubing Pipe 80 mm bore (dia), light grade with Bends, laid in Trenches or under Roads/ Flooring/ Culverts etc., complete all as specified and as directed. |
| 53 | Material & Labour for PCC 1:3:6 type C2 using 40mm graded aggregate as in plinth course, string course etc complete including slightly rounded or chamefered for Galvanised steel tubing post for air termination rod including form work etc complete all as specified and directed. |
| 54 | S&F Heat shrinkable straight through Jointing Kit 185 - 240 sqmm, 3.5 core suitable for 1100 volts grade XLPE insulated stranded aluminium conductor cable including testing on completion complete all as specified and directed by the Engr-in-Charge. |
| 55 | Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized steel earth strip 25 x 4 mm (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Figure 15A of IS 3043 :1987 incl taking out of existing earthing complete all as specified and directed. |
| 56 | Supply and fixing Galvanised iron strip 25 x 4mm for connection of earthing with LT Panel board burried in ground complete all as directed. |
| 57 | Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysAug 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender