Tender For Automation Of Water Supply Distribution Network To Jhelum Building And Left Over Portion Of Chenab Building And Its Connected Pump House At Nofra Area Under Ge(Nw) Navy Nagar, Colaba, Mumbai.
Tender Value
31.17 Lakhs
Estimated cost
Bid Submission
10 Aug 2026
18 days left
EMD
62340
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Automation Of Water Supply Distribution Network To Jhelum Building And Left Over Portion Of Chenab Building And Its Connected Pump House At Nofra Area Under Ge(Nw) Navy Nagar, Colaba, Mumbai.
BOQ
| Sl. No. | Item Description |
| 1 | Supply and fixing, Installation Testing & Commissioning of Indoor type Programmable Logic Controller based Valve Automation and communication Panel suitable for control and/or monitoring of 03 Nos. Pumps, 03 Nos Pressure Transmitter, 03 Nos. Priming Solenoid Valves, 03 Nos. Air release Solenoid Valves, 8 Nos motorized valves (+02 Spare) and 04 Nos. magnetic sensors PrimingTanks-01(2 Levels), energy meters and 01 Nos Ultrasonic level sensor, . The panel should be of suitable size fabricated from 2.0 mm thick CRCA sheet and properly powder coated. PLC with following specifications:-(i) Suitable Digital inputs/ outputs, (ii) 4 serial ports supporting open communication protocol, 01 No. Ethernet port, (iii) Programming software based on IEC to facilitate building of custom built function blocks(iv) Expandable up to 192 DI / DOs. (v) 01 No. SMPS of 5 A rating (Make: SCHNEIDER / NHP)(vi) Suitable no. of interposing relays 24 V D.C. coil rating, 4 pole and 2 A contact rating. (Make: OEN / OMRON / IDEC / ALLEN BRADLEY)(vii) Selector Switches as per requirement (Make: SCHNEIDER / ESBEE).(vii) Selector Switches as per requirement (Make: SCHNEIDER / ESBEE). The control logic shall be as directed by the Engineer In Charge for Automatic Operation of Motor Actuated Valve, Supply: 230V, 50 HzCompatible with OFC based and GPRS communication. Compatible for Wimax Connectivity if required.Mounting: Grouted on floor on angle support /on Wall |
| 2 | To make the system fully functional. all panels shall be consisting of the following :-(a) Rack mountable Web Smart Switch with 28 ports and POE for CPE hardware and following specifications:-(i) Number of Ports 24 10/100Base-TX Ethernet ports 2, 10/100/1000BASE-T 2 Combo 10/100/1000BASE-T/SFP.(ii) Port Standard Supply and fixing functions • IEEE 802.3 10BASE-T Ethernet (twisted-pair copper) • IEEE 802.3ab 1000BASE-T Gigabit Ethernet (twisted-pair copper) • IEEE 802.3x Flow Control • IEEE 802.3u 100BASE-TX Fast Ethernet (twisted-pair copper) • IEEE 802.3z Gigabit Ethernet (fiber) ANSI/IEEE 802.3 • IEEE 802.3z Gigabit Ethernet (fiber) ANSI/IEEE 802.3 Switching Capacity • 12.8 Gbps Make : Siemens, Dlink, Ubiquiti, Cisco(b) Hot pluggable 1310 nm multimode/Single mode SFP (mini-GBIC) transceiver, supporting full duplex, Gigabit speeds on multimode/Single mode fiber for distances of up to 550m/550m/10km on 62.5µm/50µm/9µm respectively in a metal housing to reduce EMI and to increase durabilityMake : Dlink, Ubiquiti, Cisco, Siemens, HP(c) Rack Mountable LIU with the following specifications:-(i) Rack Mountable 12 Port Unloaded LIU (ii) Aluminium Base Material(iii) Slim 1 U mounting height (iv) Metal Shelf Aluminium 1.2 mm thick(v) Splice tray Aluminium 0.6mm (vi) Winding Panel – Plastic |
| 3 | (vii) Cable Plug – Rubber for minimum 2 cable entries (viii) Adaptor Panel Aluminium 1.5 mm thick(ix) 2 fiber spools built in for 900 um tight buffered fibre storing(x) Capable of storing upto 3 mts of 900 um tight buffered fibre per adaptorMake : Dlink, Ubiquiti, Cisco(d) SC-LC Duplex SM Patch Cord 0.9 mm dia of suitable length (i) Size 0.9mm dia (ii) Insertion Loss <=0.2 db, max 0.3 db(iii) Return Loss PC>=45dB, UPC>=50dB, APC>=60dB (iv) Connector Ferrule Ceramic(v) Apex Offset <50um (vi) Fiber Height +-100nm (vii) End Face Radius of Curvature 7mm |
| 4 | Seamless Integration of the above PLC Panels into the Existing SCADA System incorporating (a) Development:(i) SCADA Screens for new Updated Panel configuration(ii) Layout for App new Updated Panel configuration(iii) Report Format new Updated Panel configuration(b) On-site development:(i) Modifications in SCADA Screens (ii) Modifications in reporting format(iii) Modifications in App layout Please Enable Macros to View BoQ information |
| 5 | Seamless Integration of the above PLC Panels into the Existing SCADA System incorporating (a) Development:(i) SCADA Screens for new Updated Panel configuration(ii) Layout for App new Updated Panel configuration(iii) Report Format new Updated Panel configuration(b) On-site development:(i) Modifications in SCADA Screens (ii) Modifications in reporting format(iii) Modifications in App layout Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysAug 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender