Educational and Research Institute Government Departments Closing in 10 days TDR #56568445

Bids are Invited for Repair, Maintenance, and Installation of Plant/ Systems/equipments (version 2) - Research Institute; as per Atc; as per atc -design, Manufacturing, Supply, Installation, Testing and Commissioning of air Handling Unit (ahu) and Associa

Issued by Government Departments · Delhi, Delhi
Tender Value
4.96 Lakhs
Estimated cost
Bid Submission
01 Aug 2026
10 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
1

Project Description

Bids are Invited for Repair, Maintenance, and Installation of Plant/ Systems/equipments (version 2) - Research Institute; as per Atc; as per atc -design, Manufacturing, Supply, Installation, Testing and Commissioning of air Handling Unit (ahu) and Associated Electrical System at Nii, new Delhi

BOQ

Sl. No. Item TitleItem Description
1Dismantling of 3000CFM AHUs with etc accessories completed in all respect as per the site requirementsDismantling of 3000CFM AHUs with etc accessories completed in all respect as per the site requirements
2Dismantling duly insulated pipe upto 100mmDismantling duly insulated pipe upto 100mm
3Dismantling of butterfly valve, stainer, 2-way valve, control panel etcDismantling of butterfly valve, stainer, 2-way valve, control panel etc
4Dismantling of AHUs doors and re-installation it after complete installation of AHUs with required materialsDismantling of AHUs doors and re-installation it after complete installation of AHUs with required materials
5Repairing of AHUs room as per the site requirement and making it suitable for the installation of new AHU with associated itemsRepairing of AHUs room as per the site requirement and making it suitable for the installation of new AHU with associated items
6Dismantling of volume control dampers, grills, and damper etc as per the site requirementDismantling of volume control dampers, grills, and damper etc as per the site requirement
7Providing unskilled manpower with required tools for the shifting of all dismantled materials with the Campus, as directed by the Engg-in-chargeProviding unskilled manpower with required tools for the shifting of all dismantled materials with the Campus, as directed by the Engg-in-charge
8INSULATED CHILLED WATER PIPING (NitrileINSULATED CHILLED WATER PIPING (Nitrile
9Supplying, laying, fixing, testing and commissioning of following thickness closed cell elastrometric nitrileSupplying, laying, fixing, testing and commissioning of following thickness closed cell elastrometric nitrile
10INSULATED VALVES: Supplying, fixing, testing and commissioning ofINSULATED VALVES: Supplying, fixing, testing and commissioning of
11BUTTERFLY VALVE (MANUAL) with C I body SSBUTTERFLY VALVE (MANUAL) with C I body SS
12Y - STRAINER of Ductile CI Body flanged ends withY - STRAINER of Ductile CI Body flanged ends with
13Providing and fixing in position industrial type pressure gauges with gun metal / brass valves complete etc. as required.Providing and fixing in position industrial type pressure gauges with gun metal / brass valves complete etc. as required.
14Providing & fixing in position industrial type mercuryProviding & fixing in position industrial type mercury
15Supplying, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum.Supplying, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum.
16Supplying, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation with IS : 655 and approved drawings andSupplying, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation with IS : 655 and approved drawings and
17Supplying, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc in confirmation to SMACNA/IS and as perSupplying, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc in confirmation to SMACNA/IS and as per
18Supplying, Fixing, installation, testing and commissioning of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers in confirmation to SMACNA/IS and as perSupplying, Fixing, installation, testing and commissioning of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers in confirmation to SMACNA/IS and as per
19Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete in confirmation to SMACNA/IS and as per specifications complete etc.Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete in confirmation to SMACNA/IS and as per specifications complete etc.
20Supplying, Fixing, installation, testing and commissioning of supply air diffusers of powder coated aluminium with aluminium volume controlSupplying, Fixing, installation, testing and commissioning of supply air diffusers of powder coated aluminium with aluminium volume control
21Supplying, Fixing, installation, testing and commissioning of Return air diffusers of powder coated aluminium without volume control dampersSupplying, Fixing, installation, testing and commissioning of Return air diffusers of powder coated aluminium without volume control dampers
22Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications.Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications.
23Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber (Class \\"O\\") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber (Class \\"O\\") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.
24Supplying, Installation, Testing and commissioning of factory built floor mounted chilled water double skin type horizontal/vertical air handling units in confirmation to IS 18794 : 2024 made of 25mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation factorySupplying, Installation, Testing and commissioning of factory built floor mounted chilled water double skin type horizontal/vertical air handling units in confirmation to IS 18794 : 2024 made of 25mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation factory

AI Tender Summary

OUR REF NO 56568445
AUTHORITY Government Departments
TENDER VALUE 4.96 Lakhs
LAST DATE 01-08-2026
Authority
Authority Name National Institute Of Immunology
Work Description Bids are Invited for Repair, Maintenance, and Installation of Plant/ Systems/equipments (version 2) - Research Institute; as per Atc; as per atc -design, Manufacturing, Supply, Installation, Testing and Commissioning of air Handling Unit (ahu) and Associated Electrical System at Nii, new Delhi
Basic Detail
Tender No GEM/2026/B/7812369_1
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 20 Jul 2026
Submission Date 01 Aug 2026
Open Date 01 Aug 2026
Finance
Tender Value 4.96 Lakhs
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Available
Document List
0898a7e2-9540-4c25-bb24-127b11820b41.pdf
1784567077.pdf
1784567080.pdf
1784567084.pdf
1784567087.pdf
1784567586.xlsx
ATCAHU20_4204ee2e-8da4-4ac2-98491784567527604_ELECTRICAL-NII.pdf
ATCAHU20_bd6ae0e9-27ea-4ce1-b3b41784567551646_ELECTRICAL-NII.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Aug 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
pdf

0898a7e2-9540-4c25-bb24-127b11820b41.pdf

pdf

1784567077.pdf

pdf

1784567080.pdf

pdf

1784567084.pdf

pdf

1784567087.pdf

xlsx

1784567586.xlsx

pdf

ATCAHU20_4204ee2e-8da4-4ac2-98491784567527604_ELECTRICAL-NII.pdf

pdf

ATCAHU20_bd6ae0e9-27ea-4ce1-b3b41784567551646_ELECTRICAL-NII.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders