Bids Are invited for Facility Management Services - Lumpsum Based - Commercial; O M Of Electrical Work; Consumables To Be Provided By Service Provider (Inclusive In Contract Cost) - Point Wiring In Concealed Manner With Pvc Conduit (For First Categor
Tender Overview
Project Description
Bids Are invited for Facility Management Services - Lumpsum Based - Commercial; O M Of Electrical Work; Consumables To Be Provided By Service Provider (Inclusive In Contract Cost) - Point Wiring In Concealed Manner With Pvc Conduit (For First Category Material) Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Fr Pvc Insulated Copper Conductor Single Core Cable In Consealed Manner In Heavy Duty Pvc Conduit, With Modular Switch, Modular Plate, Suitable Ms Box, Ceiling Rose And Earthing The Point With 1.5 Sq.Mm. Fr Pvc Insulated Copper Conductor Single Core Cable Etc As Required. (From Switch To First Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point) , Short Points ( From 0-3Mtrs : Distance From Switch / Taping To Point ) , Medium Point (From 3 Mtrs To 6Mtrs : Distance From Switch / Taping To Point ) , Long Points( From 6-10 Mtrs : Distance From Switch / Taping To Point ) , Open Point Wiring With Wires Of Polycab / Fino.Lex/ Kei And Suitable Casing Caping Or Conduit. No. Extra Payment Will No.T Be Made For Switches, Celling Rose Etc., Which Form Part Of Point Wiring. (Light Point / Plug Point). Wires Shall Be Of Mentioned Make , Short Points ( From 0-3Mtrs) (2C / 3C X 1.5 Sqmm ) , Medium Point (From 3 Mtrs To 6Mtrs) (2C / 3C X 1.5 Sqmm ) , Long Points( From 6-10 Mtrs) (2C / 3C X 1.5 Sqmm ) , Supply & Erecting Mains In Provided Concealed / Open Conduit Or Equivalent Or Op With 3C X 4 Sqmm F R Standard/Solid Copper Pvc Insulated Wire Of Polycab / Fino.Lex , Fr Pvc Insulated Copper Conductor, Single Core Cable In The Existing Concealed Pvc Conduit / Open Conduit As Required For The Following , 3 X 1.5 Sq. Mm , Supply Of Pvc Insulated Cu Conductor(Flexible),Industrial Cable Pvc Sheathed Cables ,1100 Volts To Is 694 3 Corex 1.5 Sqmm. Make : Polycab/Fino.Lex , Supply Of Pvc Insulated Cu Condutor(Flexible),Industrial Cable Pvc Sheathed Cables ,1100 Volts To Is 694 3 Corex2.5 Sqmm. Make : Polycab/Fino.Lex / Kei. , Laying Of Pvc / Xlpe Power Cable Alu /Cu Armored/ Unarmored All Core 1.5 Sq Mm-10 Sq Mm On Wall/Provided Trench/On Ground/On Pole With Necessary Hardware. , Supplying & Erecting Modular Type Switch 6A / 10A Isi Mark Approved Make Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying & Erecting Modular Type 3 Pin 6A Socket Isi Mark Approved Make Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supply And Fixing Of 15A Combination Of Anchor/ L &T /Legrand/ Schneider Etc. , Supply, Installation And Commissioning Of 16 A Modular Switch Of Make Hifi / L & T/Havells / Roma / Euro , Supply, Installation And Commissioning Of 16 A Modular Socket / 16-5A Combination Modular Socket Of Make Hifi / L & T/Havells / Roma / Euro , Supply, Installation And Commissioning Of 25 A Modular Switch Of Make Hifi / L & T/Havells / Roma / Euro , Supply, Installation And Commissioning Of 25 A Modular Socket Of Make Hifi / L & T/Havells / Roma , Supply, Installation Of Metalic Industrial Ac Box With Suitable 20A Plug With Metal Clad Plug Top Without Mcb. Make : Anchor / Havells / Reyrole / Havells / Poly Cab / Legrand , Supply And Erection Of 32/40A, 30Ma Rcbo, 2Pole Of Make Legrand / L&T/ Schneider / Hagger , Supply Installation And Commissioning Of Modular Sp Mcb Of Rating Up To 25 A. , Supply, Carriage, Installation And Commissioning Of 28W, 1200 Mm, Double Ball Bearing, Three Blade Bldc Ceiling Fan. Rated Air Delivery Shall Be 280 Mm Or Better. Speed Control - 5 Speed Control With Remote (Shall Be Supplied With The Fan) / With Step Type Regulator. Colour Shall Be Finalized By Site -In - Charge As Per Requirement. Type Test Certificate From Nabl Approved Lab. , Supply & Replacement Of Pvc Board Of 4 X 4 , Supply & Replacement Of Pvc Board Of 4 X 7 , Supply & Replacement Of Pvc Board Of 8 X 10 , Supply & Replacement Of Pvc Board Of 10 X 12 , Supply & Replacement Of Wooden / Other Approved Board 10 X 12 , Supply And Erection Of 8 - 9W Led Bulb Of Make Havells/ Crompton / Polycab , Supply And Erection Of 12 - 15W Led Bulb Of Make Havells/ Crompton / Polycab , Supply And Erection Of Led Tube Light Batten Of 4Ft Of Make Havells / Crompton / Polycab. , Supply Of 12 To 15 W Led Circular Down Lighter / Surface Mount Of Make : Havels / Cg/Polycab/Wipro / Philips , Supply, Installation And Commissioning Of Decorative Wall Mounted Dual-Light Vanity Luminaire In Priyadarshini/Admin. Bldg : Dual-Light Vanity Fitting With Matte Black /Bronze Finish Metal Body And Cylindrical Frosted Glass Shades. To Include All Mounting Hardware And Internal Wiring. Approval Must Be Taken From Site-In-Charge Before The Intallation And Commissioning. , Attending To No.-Light Complaints, Electrical Shock Reports, Earth Leakage Complaints, And General Circuit Failures On A Standalone Basis. The Scope Includes Fault Identification, Isolation Of Defective Segments, And Restoration Of Power. Fault Identification: Systematic Tracing Of Circuits To Identify Short Circuits, Open Circuits, Earth Leakage (Causing Shocks), Or Neutral Failures Using Calibrated Multimeters/Insulation Testers. Identified Faults Shall Be Rectified By Re-Termination Of Loose Connections At Dbs, Switches, Or Fixtures; Cleaning Of Carbonised Contacts; And Bypassing Or Replacing Mino.R Defective Wiring Segments. Provision Of All Mino.R Materials Required For The Fix, Including But No.T Limited To: Pvc Insulation Tape, Wire Ferrules, Rawl Plugs, Screws, Cable Ties, And Short Lengths Of Connecting Wire.
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Point wiring in concealed manner with PVC conduit (For First category material) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in consealed manner in heavy duty PVC conduit, with modular switch, modular plate, suitable MS box, ceiling rose and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. (from Switch to first light point/ fan point/ exhaust fan point/ call bell point) | Point wiring in concealed manner with PVC conduit (For First category material) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in consealed manner in heavy duty PVC conduit, with modular switch, modular plate, suitable MS box, ceiling rose and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. (from Switch to first light point/ fan point/ exhaust fan point/ call bell point) |
| 2 | Short Points ( from 0-3mtrs : Distance from switch / taping to point ) | Short Points ( from 0-3mtrs : Distance from switch / taping to point ) |
| 3 | Medium Point (From 3 mtrs to 6mtrs : Distance from switch / taping to point ) | Medium Point (From 3 mtrs to 6mtrs : Distance from switch / taping to point ) |
| 4 | Long Points( from 6-10 mtrs : Distance from switch / taping to point ) | Long Points( from 6-10 mtrs : Distance from switch / taping to point ) |
| 5 | Open Point Wiring with wires of polycab / fiNo.lex/ KEI and suitable casing caping or conduit. No. extra payment will No.t be made for switches, celling rose etc., which form part of point wiring. (Light point / Plug Point). Wires shall be of mentioned make | Open Point Wiring with wires of polycab / fiNo.lex/ KEI and suitable casing caping or conduit. No. extra payment will No.t be made for switches, celling rose etc., which form part of point wiring. (Light point / Plug Point). Wires shall be of mentioned make |
| 6 | Short Points ( from 0-3mtrs) (2C / 3C X 1.5 Sqmm ) | Short Points ( from 0-3mtrs) (2C / 3C X 1.5 Sqmm ) |
| 7 | Medium point (From 3 mtrs to 6mtrs) (2C / 3C X 1.5 Sqmm ) | Medium point (From 3 mtrs to 6mtrs) (2C / 3C X 1.5 Sqmm ) |
| 8 | Long Points( from 6-10 mtrs) (2C / 3C X 1.5 Sqmm ) | Long Points( from 6-10 mtrs) (2C / 3C X 1.5 Sqmm ) |
| 9 | Supply & erecting mains in provided concealed / open conduit or equivalent or op with 3C X 4 sqmm F R standard/solid copper PVC Insulated wire of POLYCAB / FiNo.lex | Supply & erecting mains in provided concealed / open conduit or equivalent or op with 3C X 4 sqmm F R standard/solid copper PVC Insulated wire of POLYCAB / FiNo.lex |
| 10 | FR PVC insulated copper conductor, single core cable in the existing concealed PVC conduit / open conduit as required for the following | FR PVC insulated copper conductor, single core cable in the existing concealed PVC conduit / open conduit as required for the following |
| 11 | 3 x 1.5 sq. mm | 3 x 1.5 sq. mm |
| 12 | Supply of PVC insulated Cu conductor(flexible),Industrial cable PVC sheathed cables ,1100 volts to IS 694 3 corex 1.5 SQMM. Make : Polycab/FiNo.lex | Supply of PVC insulated Cu conductor(flexible),Industrial cable PVC sheathed cables ,1100 volts to IS 694 3 corex 1.5 SQMM. Make : Polycab/FiNo.lex |
| 13 | Supply of PVC insulated Cu condutor(flexible),Industrial cable PVC sheathed cables ,1100 volts to IS 694 3 corex2.5 SQMM. Make : Polycab/FiNo.lex / KEI. | Supply of PVC insulated Cu condutor(flexible),Industrial cable PVC sheathed cables ,1100 volts to IS 694 3 corex2.5 SQMM. Make : Polycab/FiNo.lex / KEI. |
| 14 | Laying of PVC / XLPE power cable Alu /Cu armored/ unarmored all core 1.5 sq mm-10 sq mm on wall/provided trench/on ground/on pole with necessary hardware. | Laying of PVC / XLPE power cable Alu /Cu armored/ unarmored all core 1.5 sq mm-10 sq mm on wall/provided trench/on ground/on pole with necessary hardware. |
| 15 | Supplying & Erecting modular type switch 6A / 10A ISI mark approved make duly erected on provided plate and box with wiring connections complete. | Supplying & Erecting modular type switch 6A / 10A ISI mark approved make duly erected on provided plate and box with wiring connections complete. |
| 16 | Supplying & Erecting modular type 3 pin 6A socket ISI mark approved make duly erected on provided plate and box with wiring connections complete. | Supplying & Erecting modular type 3 pin 6A socket ISI mark approved make duly erected on provided plate and box with wiring connections complete. |
| 17 | Supply and fixing of 15A Combination of Anchor/ L &T /Legrand/ Schneider etc. | Supply and fixing of 15A Combination of Anchor/ L &T /Legrand/ Schneider etc. |
| 18 | Supply, installation and commissioning of 16 A modular switch of make Hifi / L & T/Havells / Roma / Euro | Supply, installation and commissioning of 16 A modular switch of make Hifi / L & T/Havells / Roma / Euro |
| 19 | Supply, installation and commissioning of 16 A modular socket / 16-5A combination modular socket of make Hifi / L & T/Havells / Roma / Euro | Supply, installation and commissioning of 16 A modular socket / 16-5A combination modular socket of make Hifi / L & T/Havells / Roma / Euro |
| 20 | Supply, installation and commissioning of 25 A modular switch of make Hifi / L & T/Havells / Roma / Euro | Supply, installation and commissioning of 25 A modular switch of make Hifi / L & T/Havells / Roma / Euro |
| 21 | Supply, installation and commissioning of 25 A modular socket of make Hifi / L & T/Havells / Roma | Supply, installation and commissioning of 25 A modular socket of make Hifi / L & T/Havells / Roma |
| 22 | Supply, installation of Metalic industrial AC Box with suitable 20A plug with Metal clad plug top without MCB. Make : Anchor / Havells / Reyrole / Havells / Poly cab / legrand | Supply, installation of Metalic industrial AC Box with suitable 20A plug with Metal clad plug top without MCB. Make : Anchor / Havells / Reyrole / Havells / Poly cab / legrand |
| 23 | Supply and erection of 32/40A, 30mA RCBO, 2pole of make legrand / L&T/ Schneider / Hagger | Supply and erection of 32/40A, 30mA RCBO, 2pole of make legrand / L&T/ Schneider / Hagger |
| 24 | Supply installation and commissioning of Modular SP MCB of rating up to 25 A. | Supply installation and commissioning of Modular SP MCB of rating up to 25 A. |
| 25 | Supply, carriage, installation and commissioning of 28W, 1200 mm, double ball bearing, three blade BLDC ceiling fan. Rated air delivery shall be 280 MM or better. Speed control - 5 speed control with remote (shall be supplied with the fan) / with step type regulator. Colour shall be finalized by site -in - charge as per requirement. Type test certificate from NABL approved lab. | Supply, carriage, installation and commissioning of 28W, 1200 mm, double ball bearing, three blade BLDC ceiling fan. Rated air delivery shall be 280 MM or better. Speed control - 5 speed control with remote (shall be supplied with the fan) / with step type regulator. Colour shall be finalized by site -in - charge as per requirement. Type test certificate from NABL approved lab. |
| 26 | Supply & replacement of PVC Board of 4 x 4\\" | Supply & replacement of PVC Board of 4 x 4\\" |
| 27 | Supply & replacement of PVC Board of 4 x 7\\" | Supply & replacement of PVC Board of 4 x 7\\" |
| 28 | Supply & replacement of PVC Board of 8 x 10\\" | Supply & replacement of PVC Board of 8 x 10\\" |
| 29 | Supply & replacement of PVC Board of 10 x 12\\" | Supply & replacement of PVC Board of 10 x 12\\" |
| 30 | Supply & replacement of wooden / other approved board 10\\" x 12\\" | Supply & replacement of wooden / other approved board 10\\" x 12\\" |
| 31 | Supply and erection of 8 - 9W LED Bulb of make Havells/ Crompton / Polycab | Supply and erection of 8 - 9W LED Bulb of make Havells/ Crompton / Polycab |
| 32 | Supply and erection of 12 - 15W LED Bulb of make Havells/ Crompton / Polycab | Supply and erection of 12 - 15W LED Bulb of make Havells/ Crompton / Polycab |
| 33 | Supply and erection of LED tube light batten of 4ft of make Havells / Crompton / Polycab. | Supply and erection of LED tube light batten of 4ft of make Havells / Crompton / Polycab. |
| 34 | Supply of 12 to 15 W LED circular down lighter / surface mount of make : Havels / CG/Polycab/Wipro / Philips | Supply of 12 to 15 W LED circular down lighter / surface mount of make : Havels / CG/Polycab/Wipro / Philips |
| 35 | Supply, installation and commissioning of decorative Wall mounted Dual-light vanity luminaire in Priyadarshini/Admin. bldg : Dual-light vanity fitting with matte black /bronze finish metal body and cylindrical frosted glass shades. To include all mounting hardware and internal wiring. Approval must be taken from site-in-charge before the intallation and commissioning. | Supply, installation and commissioning of decorative Wall mounted Dual-light vanity luminaire in Priyadarshini/Admin. bldg : Dual-light vanity fitting with matte black /bronze finish metal body and cylindrical frosted glass shades. To include all mounting hardware and internal wiring. Approval must be taken from site-in-charge before the intallation and commissioning. |
| 36 | Attending to No.-light complaints, electrical shock reports, earth leakage complaints, and general circuit failures on a standalone basis. The scope includes fault identification, isolation of defective segments, and restoration of power. Fault identification: Systematic tracing of circuits to identify short circuits, open circuits, earth leakage (causing shocks), or neutral failures using calibrated multimeters/insulation testers. Identified faults shall be rectified by re-termination of loose connections at DBs, switches, or fixtures; cleaning of carbonised contacts; and bypassing or replacing miNo.r defective wiring segments. Provision of all miNo.r materials required for the fix, including but No.t limited to: PVC insulation tape, wire ferrules, rawl plugs, screws, cable ties, and short lengths of connecting wire. | Attending to No.-light complaints, electrical shock reports, earth leakage complaints, and general circuit failures on a standalone basis. The scope includes fault identification, isolation of defective segments, and restoration of power. Fault identification: Systematic tracing of circuits to identify short circuits, open circuits, earth leakage (causing shocks), or neutral failures using calibrated multimeters/insulation testers. Identified faults shall be rectified by re-termination of loose connections at DBs, switches, or fixtures; cleaning of carbonised contacts; and bypassing or replacing miNo.r defective wiring segments. Provision of all miNo.r materials required for the fix, including but No.t limited to: PVC insulation tape, wire ferrules, rawl plugs, screws, cable ties, and short lengths of connecting wire. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
TodayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender